• 5.91 MB
  • 226页

广东现代国际展览中心二期扩建工程环境影响报告书

  • 226页
  • 当前文档由用户上传发布,收益归属用户
  1. 1、本文档共5页,可阅读全部内容。
  2. 2、本文档内容版权归属内容提供方,所产生的收益全部归内容提供方所有。如果您对本文有版权争议,可选择认领,认领后既往收益都归您。
  3. 3、本文档由用户上传,本站不保证质量和数量令人满意,可能有诸多瑕疵,付费之前,请仔细先通过免费阅读内容等途径辨别内容交易风险。如存在严重挂羊头卖狗肉之情形,可联系本站下载客服投诉处理。
  4. 文档侵权举报电话:19940600175。
'目录前言...................................................................................................................................................................1第1章总则................................................................................................................................................31.1编制依据................................................................................................................................................31.1.1法律法规、规划............................................................................................................................31.1.2行业标准、技术规范及有关政策................................................................................................51.1.3项目相关文件................................................................................................................................61.2功能区区划............................................................................................................................................61.2.1地表水环境功能区划....................................................................................................................61.2.2地下水环境功能区划....................................................................................................................61.2.3空气环境功能区划........................................................................................................................61.2.4声环境功能区划............................................................................................................................71.3评价标准................................................................................................................................................71.3.1环境质量标准................................................................................................................................71.3.2污染物排放标准..........................................................................................................................101.3.3其它标准......................................................................................................................................141.4评价工作等级......................................................................................................................................141.4.1地表水环境影响评价工作等级..................................................................................................141.4.2地下水环境影响评价工作等级..................................................................................................141.4.3环境空气影响评价工作等级......................................................................................................151.4.4声环境影响评价工作等级..........................................................................................................151.4.5生态环境影响评价工作等级......................................................................................................151.5评价范围..............................................................................................................................................161.5.1地表水环境评价范围..................................................................................................................161.5.2环境空气评价范围......................................................................................................................161.5.3声环境评价范围..........................................................................................................................161.5.4生态环境影响评价范围..............................................................................................................161.6评价重点和评价因子..........................................................................................................................16I 1.6.1评价重点......................................................................................................................................161.6.2评价因子筛选..............................................................................................................................171.7控制污染与保护环境的目标..............................................................................................................181.7.1污染控制目标..............................................................................................................................181.7.2环境保护目标..............................................................................................................................181.8环评工作程序......................................................................................................................................201.8.1准备阶段......................................................................................................................................201.8.2调查测试及单项评价阶段..........................................................................................................201.8.3报告书编制阶段..........................................................................................................................20第2章建设项目概况..............................................................................................................................222.1项目概况..............................................................................................................................................222.1.1项目名称、性质、建设地点......................................................................................................222.1.2项目建设规模及内容..................................................................................................................222.1.3项目总体规划和总平面布置......................................................................................................232.1.4项目四至情况..............................................................................................................................232.2主要经济技术指标..............................................................................................................................232.3公用工程..............................................................................................................................................252.3.1给排水..........................................................................................................................................252.3.2供电系统......................................................................................................................................282.3.3空调系统......................................................................................................................................322.3.4燃气系统......................................................................................................................................352.3.5通信系统......................................................................................................................................352.3.6景观..............................................................................................................................................352.3.7交通组织......................................................................................................................................352.3.8智能化方案..................................................................................................................................362.4土石方工程..........................................................................................................................................382.5建设周期..............................................................................................................................................382.6一、二期工程回顾..............................................................................................................................382.6.1一、二期工程建设内容回顾......................................................................................................382.6.2一、二期工程投入使用情况及可为本项目依托的内容...........................................................39II 2.6.3一、二期工程环境影响回顾性评价..........................................................................................39第3章工程分析......................................................................................................................................413.1工艺流程分析......................................................................................................................................413.2环境影响识别......................................................................................................................................413.2.1施工期影响识别..........................................................................................................................413.2.2运营期影响识别..........................................................................................................................433.2.3外环境影响因素识别..................................................................................................................433.3污染源分析..........................................................................................................................................443.3.1施工期污染源分析......................................................................................................................443.3.2运营期污染源分析......................................................................................................................493.3.3外环境污染源分析......................................................................................................................58第4章区域环境概况..............................................................................................................................634.1自然环境概况......................................................................................................................................634.1.1地理位置......................................................................................................................................634.1.2地形地貌......................................................................................................................................634.1.3地层岩性......................................................................................................................................644.1.4水文特征......................................................................................................................................664.1.5气象气候......................................................................................................................................674.2社会概况..............................................................................................................................................68第5章环境质量现状调查与评价..........................................................................................................735.1水环境质量现状监测与评价..............................................................................................................735.1.1水环境质量现状调查..................................................................................................................735.1.2水质现状评价..............................................................................................................................745.2环境空气质量现状监测与评价..........................................................................................................775.2.1环境空气质量现状调查..............................................................................................................775.2.2环境空气质量现状评价..............................................................................................................775.3声环境质量现状监测与评价..............................................................................................................845.3.1声环境质量现状调查..................................................................................................................845.3.2声环境质量现状评价..................................................................................................................84第6章施工期间环境影响分析及污染防治措施..................................................................................87III 6.1声环境影响与污染防治措施..............................................................................................................876.1.1声环境影响预测与分析..............................................................................................................876.1.2噪声污染防治措施......................................................................................................................896.2环境空气影响与污染防治措施..........................................................................................................916.2.1施工扬尘环境影响分析..............................................................................................................916.2.2施工废气环境影响分析..............................................................................................................926.2.3施工营地临时食堂油烟废气环境影响分析..............................................................................936.2.4装修废气环境影响分析..............................................................................................................936.2.5环境空气污染防治措施..............................................................................................................946.3水环境影响及污染防治措施..............................................................................................................956.3.1水环境影响分析..........................................................................................................................956.3.2施工期水污染防治措施..............................................................................................................966.4固体废物环境影响分析与污染防治措施..........................................................................................976.4.1固体废物环境影响分析..............................................................................................................976.4.2固体废物处理处置......................................................................................................................98第7章运营期环境影响分析及污染防治措施....................................................................................1007.1水环境影响评价及污染防治措施....................................................................................................1007.1.1项目水污染源分析....................................................................................................................1007.1.2污水正常排放的影响................................................................................................................1007.1.3地表水污染防治措施................................................................................................................1007.1.4地下水环境影响分析................................................................................................................1017.1.5地下水污染防治措施................................................................................................................1017.2环境空气影响分析及污染防治措施................................................................................................1027.2.1环境空气影响分析....................................................................................................................1027.2.2环境空气污染防治措施............................................................................................................1057.3声环境影响分析及污染防治措施....................................................................................................1067.3.1声环境影响分析........................................................................................................................1067.3.2噪声污染控制措施.....................................................................................................................1107.4固体废弃物影响分析及污染防治措施.............................................................................................1127.4.1固体废弃物影响分析.................................................................................................................112IV 7.4.2固体废物污染控制措施.............................................................................................................1127.5高楼风与日照影响分析.....................................................................................................................1127.5.1高楼风影响分析.........................................................................................................................1127.5.2日照影响分析.............................................................................................................................1157.6光污染影响分析.................................................................................................................................1167.6.1光污染及其危害.........................................................................................................................1167.6.2本项目玻璃幕墙材料特性分析.................................................................................................1177.6.3光污染影响分析与评价.............................................................................................................1187.7极限展会条件下对区域交通影响分析及交通改善措施.................................................................1197.7.1影响分析.....................................................................................................................................1197.7.2交通改善措施............................................................................................................................1217.7.3交通改善后评价........................................................................................................................1267.8外环境对本项目的影响及污染防治措施........................................................................................1277.8.1外环境污染影响分析................................................................................................................1287.8.2外环境污染防治对策措施........................................................................................................138第8章生态环境影响评价及恢复措施................................................................................................1398.1生态现状............................................................................................................................................1398.2生态影响评价....................................................................................................................................1398.2.1土地占用影响分析....................................................................................................................1398.2.2对生态系统整体影响分析........................................................................................................1398.2.3植被影响分析............................................................................................................................1408.2.4动物影响分析............................................................................................................................1408.2.5对城市生态的影响分析............................................................................................................1408.2.6水土流失评价............................................................................................................................1418.2.7景观影响分析............................................................................................................................1418.3生态恢复措施....................................................................................................................................1438.3.1绿化措施....................................................................................................................................1438.3.2水土保持措施............................................................................................................................144第9章污染防治措施经济技术经济可行性分析................................................................................1479.1污水防治措施分析............................................................................................................................147V 9.1.1污水的组成................................................................................................................................1479.1.2污水去向和污水处理措施........................................................................................................1479.1.3污水处理方案论证....................................................................................................................1479.22大气防治措施分析.........................................................................................................................1489.2.1废气的组成................................................................................................................................1489.2.2废气治理措施............................................................................................................................1489.3噪声防治对策分析............................................................................................................................1499.4固体废弃物防治措施分析................................................................................................................1519.5光污染预防措施分析........................................................................................................................1519.6高楼风的防治措施与建议................................................................................................................1529.7其他措施与建议................................................................................................................................152第10章总量控制和清洁生产................................................................................................................15410.1污染物总量控制分析.....................................................................................................................15410.1.1总量控制分析的原则、目的与意义......................................................................................15410.1.2项目主要污染物排放总量控制指标建议..............................................................................15510.1.3区域削减分析..........................................................................................................................15510.2清洁生产.........................................................................................................................................15610.2.1建筑及装饰材料的选用..........................................................................................................15610.2.2项目建筑节能评价..................................................................................................................15710.2.3节水措施..................................................................................................................................16010.2.4施工过程清洁生产..................................................................................................................16110.2.5结论..........................................................................................................................................162第11章环境风险分析............................................................................................................................16311.1施工期环境风险分析......................................................................................................................16311.1.1基坑开挖安全风险..................................................................................................................16311.1.2人工挖孔桩施工废气中毒事故..............................................................................................16311.1.3其它市政设施安全风险..........................................................................................................16311.1.4高层建筑施工安全风险..........................................................................................................16411.2运营期环境风险分析......................................................................................................................16411.2.1火灾风险引起的次生灾害分析..............................................................................................164VI 11.2.2其它风险分析..........................................................................................................................16611.3风险防范措施..................................................................................................................................16711.3.1施工期风险防范措施..............................................................................................................16711.3.2营运期风险防范措施..............................................................................................................16811.4风险应急措施..................................................................................................................................170第12章环境管理与环境监控计划........................................................................................................17212.1环境管理.........................................................................................................................................17212.1.1环境管理机构设置的目的......................................................................................................17212.1.2环境管理机构的设置..............................................................................................................17212.1.3环境管理机构的职责..............................................................................................................17212.1.4施工期环境管理计划..............................................................................................................17312.1.5运行期环境管理计划..............................................................................................................17412.2环境监控计划.................................................................................................................................17512.2.1施工期环境监测计划..............................................................................................................17512.2.2运营期监测计划......................................................................................................................17512.3环保措施―三同时‖、生态验收汇总...............................................................................................176第13章环境影响经济损益分析............................................................................................................17813.1环境效益分析.................................................................................................................................17813.1.1项目对环境带来正面影响......................................................................................................17813.1.2项目对环境带来负面影响......................................................................................................17813.2社会效益分析.................................................................................................................................17813.3经济效益分析.................................................................................................................................17813.4环境损益分析.................................................................................................................................17913.4.1环境损失..................................................................................................................................17913.4.2环保投资估算..........................................................................................................................17913.4.3环保投资收益分析..................................................................................................................18013.5结论.................................................................................................................................................180第14章项目建设与选址合理合法性分析............................................................................................18114.1项目建设与选址可行性分析..........................................................................................................18114.1.1与产业政策的相符性分析......................................................................................................181VII 14.1.2场址所在地与周边环境功能的相适性..................................................................................18114.1.3与《珠江三角洲环境保护规划纲要(2004-2020年)》相符性分析..................................18214.1.4城乡规划的相符性分析..........................................................................................................18214.2项目布局合理性分析.....................................................................................................................18314.3关于绿地率的建议.........................................................................................................................18314.4小结.................................................................................................................................................183第15章公众参与....................................................................................................................................18515.1公众参与目的、范围、工作程序..................................................................................................18515.2调查原则和方法.............................................................................................................................18715.3公众意见征询表发放和结果统计..................................................................................................19815.3.1公众意见征询表......................................................................................................................19815.3.2公众参与调查结果..................................................................................................................200第16章结论与建议................................................................................................................................20416.1项目概况.........................................................................................................................................20416.2建设项目周围环境质量现状..........................................................................................................20416.3建设期间的环境影响分析及污染防治措施..................................................................................20516.3.1施工噪声..................................................................................................................................20516.3.2施工扬尘..................................................................................................................................20616.3.3施工废水..................................................................................................................................20716.3.4固体废弃物..............................................................................................................................20716.4项目运营期环境影响分析及污染防治措施..................................................................................20916.4.1水环境影响分析及污染防治措施..........................................................................................20916.4.2环境空气影响分析及污染防治措施......................................................................................20916.4.3声影响源分析及污染防治措施..............................................................................................21016.4.4固体废弃物影响分析及污染防治措施...................................................................................21116.4.5高楼风影响分析及防范措施...................................................................................................21116.4.6光污染影响分析及污染防治措施..........................................................................................21216.4.7对区域交通影响分析及交通改善措施..................................................................................21316.5外环境污染源对本项目的影响分析及污染防治措施..................................................................21316.6规划相符性及选址合理性分析......................................................................................................214VIII 16.7公众参与.........................................................................................................................................21516.8清洁生产水平.................................................................................................................................21516.9总量控制指标.................................................................................................................................21616.10环境经济损益分析.......................................................................................................................21616.11风险评价.......................................................................................................................................21616.12总结论...........................................................................................................................................21616.13建议...............................................................................................................................................217IX 广东现代国际展览中心二期扩建工程环境影响报告书前言东莞,广东历史文化名城,是岭南文明的重要发源地、改革开放的先行地,同时也是著名的侨乡。厚街镇地处粤港经济走廊中段,北连东莞市城区,南邻虎门港,自古商贸繁荣,由传统孕育和发展起来的工、商、贸产业根深叶茂,是现代化企业家投资置业的风水宝地。目前厚街镇拥有家具企业近400家、家具专业市场10多个,从业人数超过10万人。全长5公里的家具大道是珠江三角洲地区家具及机械、材料、配件的大型集散基地。广东现代国际展览中心举办的“名家具展”是中国第一家通过UFI权威认证的家具展,已发展成为亚洲第一、世界第三的规模家具展。广东现代国际展览中心位于256省道与家具大道交界处,地块编号为F04-01、F04-02、F04-03及F03-02。总体占地面积约37.6万平方米,目前共有5个展览馆。二期扩建工程的用地范围为F04-03用地,内容包括外博大厦、A、B区展览馆和C区停车场,项目建筑占地222面积64571m,总建筑面积714839m,其中地上建筑面积522056m,地下建筑面积1927832m。外博大厦建成后高达480米,将成为东莞第一高楼,中国内地第五大高楼,其中地上部分102层,含裙楼4层(功能为外博大厦的对外办公、服务等配套用房),其余各层为不同类型的办公空间;地下部分3层,功能为地下停车库。A、B区展览馆共6层,一至五层为展览馆,B区南端为C区停车场,负二层到四层为立体停车库;展览馆地下一层为五金超市、停车库,地下二层为停车库。项目在建设过程中及建成投入使用后,将向环境排放生活污水、发电机尾气、油烟、噪声和生活垃圾等污染物,这些污染物的排放对项目周围的地表水、环境空气和声环境质量将有一定的影响。根据《中华人民共和国环境保护法》(1989年12月26日)、《中华人民共和国环境影响评价法》(2003年9月1日起执行)、《建设项目环境保护管理条列》(1998年国务院令第253号)、《广东省建设项目环境保护管理条例》(2004年7月29日广东省第十届人民代表大会常务委员会第十二次会议修正)等有关要求,广东现代国际展览中心二期扩建工程需要委托有相关环境影响评价资质的单位进行环境影响评价,编制环境影响报告书,执行环境影响报告审批制度,以保护环境,实现可持续发展。为此,广东现代国际展览中心有限公司委托重庆市环境保护工程设计研究院有限公司对广东现代国际展览中心二期扩建工程进行环境影响评价。1 广东现代国际展览中心二期扩建工程环境影响报告书接受委托后,我司组织有关环评技术人员赴现场进行勘察及收集有关资料,按《环境影响评价技术导则》所规定的原则、方法、内容和要求开展工作。针对本项目特点,本次评价主要内容包括:1、通过资料收集和现场调查,查清拟建项目周围的自然环境、社会经济和环境质量现状。2、通过对本项目的工程分析,掌握建设期和运营期废水、废气、噪声、固体废物的排放情况及污染负荷,预测其对环境的影响;通过现状监测和类比、数学模型预测,分析周围道路的交通噪声、机动车尾气、周边工业区排放的工业废气和噪声等对本项目运营期的影响,并提出相应的防治措施。3、从环境保护角度论证本项目的可行性,并提出污染防治措施和建议,为本项目环境保护计划的实施及管理部门的决策提供依据,实现项目的经济效益、社会效益和环境效益的统一协调发展。4、对项目周边敏感点以及有关部门进行公众调查,解决公众关心的环境问题,弥补环境影响评价中可能遗漏的问题。5、论证本项目的建设是否符合产业政策、城市规划等要求,并从环境保护角度对项目选址及平面布置合理性进行分析。6、对拟建工程的环境保护可行性做出明确结论。经过分析得到以下结论:项目建设符合国家的产业政策,符合城市规划和《东莞市厚街镇会展片区控制性详细规划》的相关规定。项目对周边环境的影响主要来自于施工期的扬尘与施工噪声,以及运营期的冷却塔噪声、厨房油烟等。根据预测结果,本项目建设对周边环境的影响范围和程度较小。本项目的环境影响在严格执行本评价提出的环境保护措施与污染综合防治对策的前提下是可以接受的。综上所述,本项目的选址和建设从环境保护的角度来讲是可行的。2 广东现代国际展览中心二期扩建工程环境影响报告书第1章总则1.1编制依据1.1.1法律法规、规划1、《中华人民共和国环境保护法》(1989年12月26日中华人民共和国主席令第二十二号);2、《中华人民共和城市规划法》(1989年12月26日第七次全国人民代表大会常务委员会第十一次会议通过);3、《城市绿化条例》(1992年6月22日国务院发布);4、《中华人民共和国房地产管理法》(1994年7月5日第八届全国人民代表大会常务委员会通过);5、《中华人民共和国环境影响评价法》(2003年9月1日起执行);6、《中华人民共和国节约能源法》(中华人民共和国主席令第九十号,1998年1月1日施行);7、《中华人民共和国大气污染防治法》(2000年修订);8、《中华人民共和国水污染防治法》(2008.2.28修订,2008年6月1日实行);9、《中华人民共和国环境噪声污染防治法》(1996年10月);10、《中华人民共和国固体废物污染环境防治法》(2005年4月1日);11、《中华人民共和国清洁生产促进法》(2003年1月);12、《中华人民共和国土地管理法》(1988年12月);13、《中华人民共和国水土保持法》(2010.12.25修订,2011年3月1日起执行);14、《环境影响评价公众参与暂行办法》(国家环保总局2006年2月14日,环发[2006]28号);15、《建设项目环境保护管理条例》(1998年11月29日中华人民共和国国务院令第253号;16、《地面交通噪声污染防治技术政策》(环发[2010]7号,2010年1月);17、《广东省环境保护规划纲要》(2006—2020年);3 广东现代国际展览中心二期扩建工程环境影响报告书18、《广东省建设项目环境保护管理条例》(2004年7月29日广东省第十届人民代表大会常务委员会第十二次会议修订);19、《广东省节约能源条例》广东省第十届人民代表大会常务委员会公告(第4号);20、《广东省珠江三角洲水质保护条例》(1998年11月27日);21、《广东省东江水系水质保护条例》(2003年3月27日);22、《广东省碧水工程计划》(粤府办(1997)29号文);23、《广东省蓝天工程计划》(粤府办(2000)7号文);24、《广东省地表水环境功能区划》(粤环[2011]14号);25、《广东省固体废物污染环境防治条例》,2009.5.126、《广东省环境保护条例》,2004.9.2427、《广东省固体废物污染环境防治条例》,2004.5.128、《广东省城市垃圾管理条例》,2002.1.1实施29、《广东省严控废物处理行政许可实施办法》,2009.5.130、《广东省环境保护和生态建设“十二五”规划》,2011.7.2831、《珠江三角洲环境保护一体化规划(2009-2020年)》,2009.1232、《印发广东省珠江三角洲清洁空气行动计划的通知》,粤环发[2010]18号33、《珠江三角洲环境保护一体化规划(2009-2020年)》,2009.1234、《印发广东省珠江三角洲清洁空气行动计划的通知》,粤环发[2010]18号35、《广东省地下水功能区划》,2009.8;36、《饮用水水源保护区污染防治管理规定》(1989年);37、《珠江三角洲环境保护规划纲要》(粤环函[2005]111号);38、《东莞市水环境功能区划》(1999年);39、《关于进一步加强我市环境保护的规定》(东府〔1996〕8号文);40、《广东省建设项目环保管理公众参与实施意见》的通知(粤环[2007]99号文);41、《东莞市城市总体规划》(2000-2015年);42、《东莞市土地利用总体规划》(2006-2020);43、《东莞市环境保护规划》(2005-2020);44、《厚街镇总体规划(2001-2020)》;45、《东莞市东江与水库联网供水水源工程规划》;4 广东现代国际展览中心二期扩建工程环境影响报告书46、《东莞市污水处理工程建设规划(2003-2020年)》东莞市环保局2003年12月;47、《东莞市环境噪声防治规定》(1996年5月24日东莞市第十一届人民代表大会常务委员会第十二次会议通过)。1.1.2行业标准、技术规范及有关政策1、《环境影响评价技术导则总纲》(HJ2.1-2011);2、《环境影响评价技术导则大气环境》(HJ2.2-2008);3、《环境影响评价技术导则地面水环境》(HJ/T2.3-93);4、《环境影响评价技术导则声环境》(HJ2.4-2009);5、《环境影响评价技术导则地下水环境》(HJ610-2011);6、《环境影响评价技术导则生态影响》(HJ19-2011);7、《建设项目环境风险评价技术导则》(HJ/T169-2004);8、《健康住宅建设技术要点(2004年版)》(国家住宅与居住环境工程中心);9、《防治城市扬尘污染技术规范》(HJ/T393-2007);10、《关于发展节能省地型住宅和公共建筑的指导意见》(建科[2005]78号);11、《民用建筑节能管理规定(2005年修订)》(中华人民共和国建设部令第143号发布);14、《产业结构调整指导目录(2011年本)》;15、《广东省产业结构调整指导目录(2007年本)》粤发改产业[2008]334号;16、《关于加强环境管理促进经济结构调整的若干意见》(东府办[2003]37号印发);17、《关于加强饮食娱乐服务企业环境管理的通知》(环监[1995]100号文);18、《关于印发<东莞市产业导向目录(2008年本)>的通知》(东府[2009]6号);19、《饮食业环境保护技术规范》(HJ554-2010);20、《防治城市扬尘污染技术规范》(HJ/T393-2007);21、《东莞市城市规划技术规定》;22、《关于<东莞市城市规划管理技术规定>的更正、补充的通知》(东规发[2008]26号),东莞市城建规划局;23、东莞市厚街镇会展片区控制性详细规划,东莞市厚街镇政府,2011.09。5 广东现代国际展览中心二期扩建工程环境影响报告书1.1.3项目相关文件1、《东莞市城市轨道交通建设及网络规划环境影响报告书(简本)》,中铁二院工程集团有限责任公司,2011年5月2、《穗莞深城际轨道交通工程环境影响报告书(简本)》,中铁第四勘察设计院集团有限公司,2008年11月3、《广东现代国际展览中心设计方案交通影响评价》4、建设项目环保审批手续办理告知书。5、建设项目环评委托书;6、设计方案,;7、广东现代国际展览中心有限公司提供的其它相关资料。1.2功能区区划1.2.1地表水环境功能区划项目所排污水主要是生活污水,生活污水经三级化粪池处理后排入市政下水道管网,汇入厚街沙塘污水处理厂,经处理达标后排入东莞运河。根据《广东省地表水功能区划》(粤环[2011]14号),地表水执行《地表水环境质量标准》(GB3838-2002)III类水质标准。1.2.2地下水环境功能区划根据《广东省地下水功能区划》,项目所在区域属于东江东莞地下水水源涵养区,地下水环境质量执行《地下水质量标准》(GB/T14848-93)Ⅲ类标准。1.2.3空气环境功能区划根据项目所在位置及《东莞市环境保护规划》(2005-2020)和《环境空气质量标准》(GB3095-2012)中的有关要求和规定,建设项目所在区域属于环境空气质量二类功能区,执行《环境空气质量标准》(GB3095-2012)二级标准。6 广东现代国际展览中心二期扩建工程环境影响报告书1.2.4声环境功能区划根据《声环境质量标准》(GB3096-2008)有关规定和项目周围情况,项目声环境质量执行《声环境质量标准》(GB3096-2008)2类标准。该项目所在地区环境功能属性见表1.2-1。表1.2-1建设项目环境功能属性编号项目类别1水环境功能区东莞运河执行(GB3838-2002)中的III类标准2环境空气质量功能区二类区,执行《环境空气质量标准》(GB3095-2012,)二级标准3声功能区2类区,执行《声环境质量标准》(GB3096-2008)2类标准东江东莞地下水水源涵养区4地下水环境功能区执行《地下水质量标准》(GB/T14848-93)Ⅲ类标准5是否污水处理厂集水范围是,东莞市厚街沙塘污水处理厂1.3评价标准1.3.1环境质量标准(1)地表水环境根据《广东省地表水功能区划》(粤环[2011]14号),东莞运河执行《地表水环境质量标准》(GB3838-2002)III类水质标准。见表1.3-1。表1.3-1地表水环境质量标准(单位:mg/L,pH除外)指标(GB3838-2002)III类标准pH值(无量纲)6~9溶解氧≥5化学需氧量≤20五日生化需氧量≤4氨氮≤1.0总磷(以P计)≤0.2石油类≤0.05阴离子表面活性剂0.2(2)地下水环境根据《广东省地下水功能区划》,项目所在区域属于东江东莞地下水水源涵养区,地下水环境质量执行《地下水质量标准》(GB/T14848-93)III类标准。7 广东现代国际展览中心二期扩建工程环境影响报告书表1.3-2地下水环境质量评价执行标准单位:mg/L,pH值除外序号污染因子标准限值序号污染因子标准限值1pH(无量纲)6.5~8.512氯化物≤2502总硬度≤45013氟化物≤1.03高锰酸盐指数≤3.014六价铬≤0.054砷≤0.0515氨氮≤0.25硫酸盐≤25016硝酸盐≤206氰化物≤0.0517亚硝酸盐≤0.027挥发酚≤0.00218镉≤0.018铅≤0.0519汞≤0.0019铁≤0.320锰≤0.110溶解性总固体≤100021锌≤1.011总大肠菌群≤3.0(个/L)(3)环境空气项目所在地属会展用地,其环境空气质量属二类功能区,项目周围SO2、NO2和PM10大气环境质量现状评价执行《环境空气质量标准》(GB3095-2012)中二级标准。项目周边存在化工、制鞋、家具制造企业,排放的大气特征污染物主要为苯、甲苯、二甲苯等有机物,对项目区大气环境产生一定的影响。苯、二甲苯参照《工业企业设计卫生标准》中“居住区大气中有害物质的最高容许浓度”。甲苯参照―前苏联(1974)居住区大气中有害物最大允许浓度‖的规定。详见表1.3-3。8 广东现代国际展览中心二期扩建工程环境影响报告书表1.3-3环境空气质量评价执行标准3项目取值时间浓度限值(mg/m)选用标准年平均0.06二氧化硫24小时平均0.15SO21小时平均0.50年平均0.04二氧化氮24小时平均0.08《环境空气质量标准》NO21小时平均0.20(GB3095-2012)二级标准可吸入颗粒物年平均0.07PM10日平均0.15一氧化碳24小时平均4CO1小时平均10一次2.40苯日平均0.80工业企业设计卫生标准一次0.30(TJ36-79)二甲苯日平均/一次/前苏联(1974)居住区大气中甲苯日平均0.6有害物最大允许浓度(4)声环境项目所在区域声环境质量执行《声环境质量标准》(GB3096-2008)中2类标准。本项目北侧用地红线6.4m外为家具大道,为城市主干道,南侧红线7.5m外为会展南路,为城市次干道。根据《城市区域环境噪声适用区划分技术规范》(GB/T15190-94),道路交通干线两侧区域,若临街建筑以高于三层楼房以上(含三层)的建筑为主,将第一排建筑物划分为4类标准适用区域;若临街建筑以低于三层楼房建筑(含开阔地)为主,将道路红线外一定距离内的区域划分为4类标准适用区域,距离的确定如下:相邻区域为1类标准适用区域,距离为45m±5m,相邻区域为2类标准适用区域,距离为30m±5m,相邻区域为3类标准适用区域,距离为20m±5m。本项目临家具大道一侧的建筑物包括有外博大厦展览馆A,其中外博大厦属于三层以上的建筑,但是展览馆低于三层,而且展览馆为主,因此,项目临家具大道一侧红线内但是距离家具大道30m以外部分应执行4a类标准,距离家具大道30m以内的范围执行2类标准;项目南面临会展南路一侧建筑物为低于三层建筑物,区域为2类标准适用区,因此,南面红线内距离道路30m范围内应执行4a类标准,其余的范围执行2类标准。相关标准值见表1.3-4。9 广东现代国际展览中心二期扩建工程环境影响报告书表1.3-4声环境质量评价执行标准单位:dB(A)声功能区类别昼间夜间选用标准26050《声环境质量标准》(GB3096-2008)4a70551.3.2污染物排放标准(1)水污染物排放标准水污染物排入市政管网执行广东省《水污物排放限值》(DB44/26-2001)第二时段三级标准,同时应满足厚街镇污水处理厂的进水要求,见表1.3-5;经污水处理厂处理后排放,执行《城镇污水处理厂污染物排放标准》(GB18918-2002)一级B标准,见表1.3-6。表1.3-5水污染物排放限值(mg/L,pH除外)污染物指标(DB44/26—2001)第二时段三级标准pH值6-9CODCr500BOD5300SS400动植物油100LAS20氨氮-总磷-表1.3-6城市污水处理厂污染物排放标准单位:mg/L污染物(GB18918-2002)一级B标准pH值6-9CODCr60BOD520SS20动植物油3LAS1总氮20氨氮8(15)*总磷1石油类3*括号外数值为水温>12℃时的控制指标,括号内数值为水温≤12℃时的控制指标。(2)大气污染物排放标准备用发电机的燃油废气:根据《关于柴油发电机排气执行标准的复函》(环函[2005]350号),对烟气黑度排放限值按林格曼黑度1级执行,对二氧化硫、氮氧化物、烟尘等污染物的10 广东现代国际展览中心二期扩建工程环境影响报告书排放应执行《大气污染物综合排放标准》(GB16297-1996)新污染源大气污染物排放限值中33的二级标准。二氧化硫、氮氧化物及烟尘的最高允许浓度限值分别为550mg/m、240mg/m3和120mg/m,展览区排气筒高度为43m,排放高度不能满足“高出周围200米半径范围的建筑5米以上”的要求,排气筒应按其高度对应的表列排放速率标准值严格50%执行。因此,展览区二氧化硫、氮氧化物及烟尘的最高允许速率为14.6kg/h、4.525kg/h、22.65kg/h。施工期临时食堂油烟:项目施工期人员约400人就餐,相当于中型餐饮单位,参照执行《饮食业油烟排放标准(试行)》(GB18483-2001)。表1.3-7饮食业单位的规模划分(GB18483-2001)规模中型基准灶头数≥3,<6对应灶头总功率≥5.00,<102对应排气罩灶面总投影面积(m)≥3.3,<6.6表1.3-8饮食业单位的油烟最高允许排放浓度和油烟净化设施最低去除效率规模中型3最高允许排放浓度(mg/m)2.0净化设施最低去除效率(%)75装修废气:根据《民用建筑工程室内环境污染控制规范》(GB50325-2010),民用建筑工程及室内装修工程完工七日后室内环境质量须遵循限量标准见表1.3-9。表1.3-9民用建筑工程室内环境污染物浓度限值污染物名称取值时间浓度限值3氨1小时平均0.20mg/m3甲醛1小时平均0.10mg/m3氡222Rn1年平均400Bq/m3苯1小时平均0.09mg/m3TVOC8小时平均0.60mg/m垃圾站臭气:执行执行《恶臭污染物排放标准》(GB14554-93)的二级标准,见表1.3-10。3表1.3-10垃圾站恶臭污染物场界排放限值单位:mg/m,臭气浓度除外二级序号控制项目新扩改建1氨1.52三甲胺0.083硫化氢0.0611 广东现代国际展览中心二期扩建工程环境影响报告书二级序号控制项目新扩改建4甲硫醇0.0075甲硫醚0.076二甲二硫0.067二硫化碳3.08苯乙烯5.09臭气浓度20(3)噪声排放标准项目噪声执行《社会生活环境噪声排放标准》(GB22337-2008)中的2类标准,见表1.3-11。噪声通过建筑物结构传播至噪声敏感建筑物室内时,噪声敏感建筑物室内应满足《社会生活环境噪声排放标准》(GB22337-2008)中“结构传播固定设备室内噪声排放标准限值”的2类排放限值,详见表1.3-12和表1.3-13。表1.3-11环境噪声排放标准(单位:dB(A))(GB12348—2008)2类标准昼间夜间6050表1.3-12结构传播固定设备室内噪声排放限值(等效声级)(单位:dB(A))房间类型房间型A类房间B类房间时段噪声敏感建筑昼间夜间昼间夜间声环境所处功能区类别2、3、445355040说明:A类房间—指以睡眠为主要目的,需要保证夜间安静的房间,包括住宅卧室、医院病房、宾馆客房等。B类房间—指主要在昼间使用,需要保证思考与精神集中、正常讲话不被干扰的房间、包括学校教室、会议室、办公室、住宅中卧室以外的其他房间等。表1.3-13结构传播固定设备室内噪声排放限值(倍频带声压级)(单位:dB(A))声环境功能区室内噪声倍频带声压级限值时段倍频带中心频类别31.563125250500A类房间79635244382、3、4昼间B类房间826756494312 广东现代国际展览中心二期扩建工程环境影响报告书声环境功能区室内噪声倍频带声压级限值时段倍频带中心频类别31.563125250500A类房间7255433529夜间B类房间7659483934建设期间的噪声标准执行《建筑施工场界环境噪声排放标准》(GB12523-2011),施工噪声在其施工场界的限值见表1.3-14。表1.3-14建筑施工场界环境噪声排放标准(单位:dB(A))昼间夜间7055(4)固体废弃物本项目排放的固体废弃物应该执行《国家危险废物名录》(2008年8月1日起施行)和《广东省严控废物名录》(粤环[2004]106号)、《广东省严控废物处理行政许可实施办法》的要求,对危险废物和严控废物按照规定进行分类和处置。(5)光污染控制根据《玻璃幕墙工程技术规范》(JGJ102-2002)的规定,玻璃幕墙应采用反射比不大于0.3的玻璃幕墙。(6)建筑日照要求根据《东莞市城市规划技术规定》、《关于<东莞市城市规划管理技术规定>的更正、补充的通知》,非居住建筑(即本项目)与居住建筑的间距,应符合下列规定:非居住建筑位于居住建筑南侧或东西侧的,其间距应满足国家规定的日照条件。《城市居住区规划设计规范(GB50180-93)》的规定:“大城市住宅日照标准为大寒日≥2小时,冬至日≥1小时……”,因此,项目(外博大厦)建成后,对北侧居住建筑的日照影响应确保其满足《城市居住区规划设计规范(GB50180-93)》的要求。(7)水土流失根据《广东省人民政府授权发布全省水土流失重点防治区的通告》,东莞属于重点监督区,本项目应属于建设类项目,水土流失防治应执行《开发建设项目水土流失防治标准》(GB50434-2008)中建设类项目的二级标准,见表1.3-15。表1.3-15建设类项目水土流失防治标准分级二级标准分类时段施工期试运行期扰动土地整治率(%)*95水土流失总治理度(%)*8513 广东现代国际展览中心二期扩建工程环境影响报告书土壤流失控制比0.50.7拦渣率(%)9095林草植被恢复率(%)*95林草覆盖率(%)*201.3.3其它标准1、《室内空气质量标准》(GB/T18883-2002);2、《建筑设计防火规范》(GB50016-2006);3、《饮食业油烟排放标准(试行)》(GB18483-2001);4、《饮食业环境保护技术规范》(HJ554-2010)。1.4评价工作等级按《环境影响评价技术导则》要求,结合项目工程特点和区域环境特征,本评价工作等级确定如下。1.4.1地表水环境影响评价工作等级按照《环境影响评价技术导则地表水环境》(HJ/T2.3-93)中的规定,建设项目地表水影响评价等级依据项目的污水排放量、污水水质的复杂程度、受纳水体的规模及其水质要求确定。3项目的水污染源主要为生活污水,废水排放总量为1447.1m/d,其主要污染物为CODCr、BOD5等非持久性污染物,项目产生的废水经市政污水管网纳入市政污水处理厂处理。根据环评导则,水环境影响评价的工作等级为三级。1.4.2地下水环境影响评价工作等级根据《环境影响评价技术导则地下水环境》(HJ610-2011)及项目所在相关水文、地质勘探资料,项目所在区域的地下水不作为饮用水源,因此,项目所在区域不属于敏感区域;-7另外项目包气带岩土的渗透系数小于10cm/s,且连续分布、稳定;同时项目属于相对清洁的开发项目,所排的污水主要为生活污水,化粪池均进行有效防渗处理,污水均通过封闭的管道输送,基本不下渗地下,同时项目施工过程基本不开采或破坏地下水。因此,项目所排14 广东现代国际展览中心二期扩建工程环境影响报告书污水对地下水环境影响甚微,其地下水环境影响评价等级为三级。本评价将通过定性分析提出相应的减缓地下水环境影响的措施。1.4.3环境空气影响评价工作等级项目周围地势平坦、开阔,大气扩散条件较好,根据拟建项目的工程分析,本项目产生的大气污染物主要为停车场汽车尾气和备用发电机排出的废气等。对于房地产类“特殊项目”的评价等级,新大气导则没有具体涉及。环境保护部环境工程评估中心、环境保护部环境工程评估中心环境质量模拟重点实验室在网络上对此问题的解答如下:对于房地产项目,排放的油烟不用考虑用估算模式的计算,因为只有排放标准,没有环境空气质量标准;关于车库,地上车库和地下车库排放是间断的,一般也不用直接参与评价等级的计算,因为评价等级的计算对象一般为“正常工况下持续排放的污染源”。因此普通房地产项目(不包括自带采暖设施)可以直接按三级评价要求执行。本项目虽然不属于房地产项目,但是其污染与房地产项目基本一致,也以油烟排放和车库大气污染物排放为主,故本项目大气环境影响评价等级定为三级。1.4.4声环境影响评价工作等级按照《环境影响评价技术导则声环境》(HJ2.4-2009)中的规定,声环境影响评价工作等级依据建设项目规模、噪声种类及数量、建设前后声级的变化程度及评价范围内有无敏感目标来确定。项目以会议展览为主要功能,主要噪声源为水泵房、风机、配电房、备用发电机等机电设备噪声,项目位于声环境2类区内,建成后边界噪声值增加小于3dB(A),且受影响人口变化不大,根据《环境影响评价技术导则声环境》(HJ2.4-2009)中内容的规定,本评价噪声等级定为二级。1.4.5生态环境影响评价工作等级按照《环境影响评价技术导则生态影响》(HJ19-2011)中的规定,生态环境影响评价主要依据建设项目对生态影响的程度和范围来确定评价工作等级。15 广东现代国际展览中心二期扩建工程环境影响报告书2项目工程影响区域小于2km,同时项目所在区域不存在珍稀濒危物种消失的情况,属于一般区域,根据《环境影响评价技术导则生态影响》(HJ19-2011)中等级确定原则,项目生态环境影响评价工作等级为三级。1.5评价范围1.5.1地表水环境评价范围项目所在区域属于东莞市厚街沙塘污水处理厂集水范围,项目所排污水由市政污水管网进入东莞市厚街沙塘污水处理厂经生化处理后达标排放至东莞运河。因此本次对地表水环境现状的评价范围为东莞运河厚街沙塘污水处理厂排污口上游500米至下游1000m的范围;对生活污水的影响评价则主要分析项目污水达标排放和纳入城市污水处理厂的可行性。1.5.2环境空气评价范围按《环境影响评价技术导则大气环境》大气环境(HJ2.2-2008)中的规定,评价范围的直径或边长一般不小于5km。该项目环境空气评价范围为建设项目选址所在地为中心,半2径为2.5km、面积约为25km的方形区域。见附图1.5-1。1.5.3声环境评价范围项目场址边界外200m的区域范围。见附图1.5-1。1.5.4生态环境影响评价范围项目对周边生态环境影响不大,项目生态环境评价范围为项目占地范围内。1.6评价重点和评价因子1.6.1评价重点1、施工期以施工噪声、扬尘及建筑垃圾的污染防治措施和生态环境影响评价为重点。2、运营期16 广东现代国际展览中心二期扩建工程环境影响报告书项目产生的生活污水进入东莞市厚街沙塘污水处理厂的可行性;外博大厦建成后为高达480米的超高层建筑物,根据建筑物的特点和所处地理位置的敏感性,运营期主要关注高大建筑环境影响分析、光遮挡、光污染环境影响。项目建成后周边城市道路家具大道、S256、会展南路的交通噪声、汽车尾气对本项目的影响;东面地铁2号线、南面穗莞深城际轨道运行时噪声、振动、电磁辐射对本项目的影响;周边工业污染源对本项目的影响。1.6.2评价因子筛选根据项目的污染物排放特征及所在区域的环境污染特征确定工程环境影响评价因子为:施工期:本项目施工期对环境的主要影响因素是噪声、扬尘,其次为废水和建筑固体废弃物。运营期:1、地表水环境:现状评价——pH、DO、CODCr、BOD5、SS、氨氮、总磷、总氮、LAS;影响分析——CODcr、氨氮。2、环境空气:现状评价——SO2、CO、NO2、PM10、苯、甲苯、二甲苯;影响分析——SO2、NO2。3、声环境:等效连续A声级。4、固体废物:固体废弃物产生量和处置量。5、生态环境:生物量、物种、覆盖率等。17 广东现代国际展览中心二期扩建工程环境影响报告书1.7控制污染与保护环境的目标1.7.1污染控制目标水污染控制目标:尽量减少生活污水的排放,使污水处理厂不因本项目而改变其正常运行。大气污染控制目标:尽量减少项目废气污染物排放,使周围大气环境不因本项目的建设而受到影响。噪声污染控制目标:施工期和运营期采取各种降噪的措施,减少噪声对项目内和外环境的影响。1.7.2环境保护目标本评价的环境保护目标为保护项目所在区域的整体环境质量,确保项目选址周围环境质量不因本项目的建设而发生显著改变。评价范围内的环境保护目标为评价区内的环境敏感点,建设项目选址附近主要环境保护目标见表1.7-1及附图1.5-1。18 广东现代国际展览中心二期扩建工程环境影响报告书表1.7-1主要环境保护目标环境保护与该项目边序号方位规模功能性质功能要求敏感目标界的距离(米)村民5500多人,外来常住人口约1涌口村西北2250居民区18000人2双岗村西北2000常住人口大约7000人居民区常住人口7800人,外来常住人口3桥头村东北1700居民区18000多人《环境空气质4新塘小学北100016个教学班,学生800多人学校量标准》常住人口6000多人,外来人口约2(GB3095-2012)5新塘村北680居民区万人二级标准6南五村西北820户藉人口为1200多人居民区常住户籍人口2054人,外来常住7沙塘村南1100居民区人口约7000人8沙塘小学南140016个教学班,学生800多人学校《环境空气质量标准》(GB3095-2012)第一排村民户籍人口3676人,外来人口约2二级标准、9溪头村东南居民区住宅120m万人《声环境质量标准》(GB3096-2008)中2类标准编制床位近500张,全院编制总人《环境空气质数800人。全院设立临床和医技科量标准》医疗服务10仁康医院西南120m室20余个,其中心血管内科、呼吸(GB3095-2012)设施内科、创伤骨科、泌尿外科、妇科、二级标准、儿科等专科具有明显学科优势。《声环境质量标准》华庭花园11东南120m社会服务(GB3096-200酒店8)中4a类标准19 广东现代国际展览中心二期扩建工程环境影响报告书1.8环评工作程序项目的环境影响评价工作程序将按环境影响评价技术的有关要求进行,主要从以下三个阶段进行。1.8.1准备阶段本阶段主要是在环境现状初步调查和工程初步分析的基础上,进行环境影响识别,筛选重点评价项目,确定各单项环境影响评价工作等级。1.8.2调查测试及单项评价阶段根据确定的各单项环境影响评价工作等级,逐步开展各项工作,包括:进一步对工程地区进行现场查勘;调查、走访现场和有关部门,收集与项目有关的区域环境资料;并向项目所在区域内有关团体和个人发放公众参与调查表;根据环境现状调查结果和工程分析,对项目建设产生的环境影响进行预测评价。1.8.3报告书编制阶段在各单项环境影响分析和预测评价的基础上,针对项目建设对环境产生的不利影响,提出相应的环境保护措施,确定环境监测与环境管理规划,进行环境经济损益分析,论证项目建设的可行性,编制完成环境影响报告书。评价工作程序见图1.8-1。20 广东现代国际展览中心二期扩建工程环境影响报告书环境影响评价委托1、研究国家和地方有关环境保护的法律法规、政策、标准及相关规划等2、依据相关规定确定环境影响评价文件类型第1、研究相关技术文件和其他有关文件一2、进行初步工程分析阶3、开展初步的环境状况调查段环境影响因素识别与评价因子筛选1、明确评价重点和环境保护目标2、确定工作等级、评价范围和评价标准有重大制定工作方案变化公评价范围内的环境现建设项目工程众状调查、监测与评价分析参第与二阶段各环境要素环境影响预测与评价各专题环境影响分析与评价第1、提出环境保护措施,进行技术经济论证三2、给出建设项目环境可行性的评价结论阶段编制环境影响评价文件图1.8-1建设项目环境影响评价工作程序21 广东现代国际展览中心二期扩建工程环境影响报告书第2章建设项目概况2.1项目概况2.1.1项目名称、性质、建设地点项目名称:广东现代国际展览中心二期扩建工程建设性质:扩建建设单位:广东现代国际展览中心有限公司项目投资:199187万元建设地点:项目位于东莞市厚街镇家具大道新塘路段,详见附图2.1-1。用地范围:广东现代国际展览中心地块编号为F04-01、F04-02、F04-03及F03-02。二期扩建工程用地属于F04-03地块的一部分。详见附图2.1-2。2.1.2项目建设规模及内容222项目建筑占地面积64571m,总建筑面积714839m,其中地上建筑面积522056m,2地下建筑面积192783m。项目建设内容包括外博大厦、A、B区展览馆和C区停车场。外博大厦为超高层建筑,建筑物高达480m,其中地上部分102层;含裙楼4层,面积为16434平方米,功能为外博大厦的对外办公、服务等配套用房;其余各层为不同类型的办公空间,面积为245000平方米,每层标准层面积2700平方米;地下部分3层,功能为地下停车库。A、B区展览馆共6层,楼高37.8米,总建筑面积为260550平方米。一至六层为展览馆,展览馆地下一层为五金超市、停车库,地下二层为停车库,面积约为15万平方米,展览馆南北向长约为326米,东西向宽约为180米。C区停车场位于B区南端,负二层到四层为立体停车库。项目各层平面图见附图2.1-3。2此外,项目在二期地面南侧建设垃圾收集站一座,独立占地约72m。本项目不设餐饮,办公人员的就餐均依托附近的餐饮业解决,故项目也不预留餐饮业专用烟道。22 广东现代国际展览中心二期扩建工程环境影响报告书2.1.3项目总体规划和总平面布置总体规划外博大厦以东莞市花“白玉兰”为设计意象,顶部企业会所运用现代建筑的设计语言以花瓣的形态层层叠叠,形成盛开之势绽放于480米高的“莞城”上空,标志性建筑所特有的综合美感和现代感应运而生。A、B区展览馆外部以动感的横向线条呼应,内部通过蜿蜒秀美的连廊将南北两个区有机地组织起来,整体简洁大气,为观展者提供一个宏大而又舒适的展览空间。立面以石材、玻璃、铝合金百叶为主要材料,石材坚实、大气,玻璃简洁明快,再加上金属百叶的有序变化,使建筑立面形态充满时代气息,体现区域未来的发展特征。总平面布置项目主要由外博大厦、A、B区展览馆和C区停车场组成。外博大厦位于地块东北面,A、B区展览馆、C区停车场由北往南分布。项目总平面布置图见附图2.1-4,效果图见附图2.1-5。项目具体商业项目需另行申报进行环境影响评价。2.1.4项目四至情况项目北面为家具大道,南面为会展南路,西面为广东现代国际展览中心三期用地,目前用作二期扩建工程的临时堆土场,东面为广东现代国际展览中心一期及二期用地,分别为展览馆A、B、C、D区。详见附图2.1-6。2.2主要经济技术指标项目属于《东莞市厚街镇会展片区控制性详细规划》F04-03地块的一部分。F04-03地块包含广东现代国际展览中心二期、二期扩建工程。地块控制指标见下表。表2.2-1F04-03地块控制指标22地块编号用地性质用地面积m建筑面积m容积率建筑密度建筑限高m绿地率配建车位(个)F04-03会展用地1698756115503.60.64800.24612二期扩建项目综合技术经济指标见表2.2-2。23 广东现代国际展览中心二期扩建工程环境影响报告书表2.2-2综合技术经济指标一览表二期扩建工程二期工程项目合计单位(拟建部分)(已建部分)*2规划用地面积93780.9762875.33156656.3m建筑占地面积6457120744853152总建筑面积71483941930756769m2计容建筑面积52205641930563986m展览2展览馆部分(A、B区)26055013428m馆B展览2外博大厦裙楼1643414361m其中馆C展览外博大厦塔楼24500014141馆D2垃圾站72m2地下建筑面积(不计容)1927830192783m展览馆部分162908其中外博大厦29877建筑密度703355%容积率5.560.673.6—2绿地面积182580m展览馆部分157380其中外博大厦25200绿地率19.5011.7<20%最大层数1202/层最大高度48024.3/m停车位461204612泊地上4120412泊其中地下420004200泊注:二期工程(已建部分)*参照相关验收资料。对照《东莞市厚街镇会展片区控制性详细规划》F04-03地块控制指标,地块内建设经济技术各参数均能满足要求,仅绿地率低于20%,建议增加绿地面积。此外,项目二期扩建后,原二期已经建设好的展览馆A馆将拆除,改为休闲广场。24 广东现代国际展览中心二期扩建工程环境影响报告书2.3公用工程2.3.1给排水2.3.1.1给水水源:本工程的水源为市政自来水,展览馆分别从南北市政道路上驳接2路DN300进水管,经水表计量后,在用地红线内沿展馆周围连成环状供水管网。外博大厦单独从北面市政道路上驳接1路DN250进水管。供水压力按0.25MPa计,可满足本建筑水质和水量要求。项目的用水量计算见后面工程分析。给水系统:(1)展览馆本建筑12m标高及以下用水点采用市政压力直接供水,12m以上用水点采用水箱加变频恒压供水设备供水。室外给水管在建筑物周围成环状布置,展厅用水就近从环管上接出给水管供给。在地下3室设400m不锈钢生活水箱,生活给水系统设一套变频恒压供水设备(性能参数:Q=120L/s,H=70m,N=180kW)供水,冷却塔补水系统设一套变频恒压供水设备(性能参数:Q=40L/s,H=62.4m,N=60kW)供水。生活给水采用下行上给方式枝状管网供水。展厅设置小型分散式饮水机提供饮用水,茶水间设置电开水器提供开水,办公区设置桶装饮水机提供饮用水。(2)外博大厦本建筑2层及以下用水点采用市政压力直接供水,2层以上采用串联水箱供水方式供水。3在地下室生活水泵房设350m不锈钢生活水箱。生活水泵房内设置生活转输泵3台(性能参数:Q=25L/s,H=160m,N=75kW,两用一备)和冷却塔补水系统设变频恒压供水设备一套(性能参数:Q=25L/s,H=61m,N=30kW)。在25层、50层分别设置容积40立方米的中间水箱和生活转输泵3台(25层转输泵性能参数:Q=18L/s,H=134m,N=37kW,两用一备;50层转输泵性能参数:Q=12.5L/s,H=137m,N=30kW,两用一备),75层设容积80立方米的生活水箱和变频恒压供水设备一套(性能参数:Q=15L/s,H=150m,N=45kW)。3层~71层由水箱重力供水,72层~天面层由设置在75层的变频恒压供水设备供水。办公区茶水间设置电开水器提供开水。25 广东现代国际展览中心二期扩建工程环境影响报告书2.3.1.2排水本工程室外排水采用雨水、污水分流制系统,周围市政管网完善,能接纳本工程排放的雨水、污水,生活污水排入市政污水管,由市政污水厂统一处理后排放。室内雨水和道路雨水在室外用管道汇集,排入市政雨水管。项目的排水量见后面工程分析。污水系统:本工程室内采用污水、废水合流系统。为保证排水通畅,改善卫生条件,公共卫生间设置环型通气管,排水立管设置主通气立管,升顶通气。生活污水经化粪池预处理后排至市政3污水管网。展览馆设置有效容积为100m的钢筋砼化粪池四座,外博大厦设置有效容积为3100m的钢筋砼化粪池三座。地下室污废水采用潜污泵提升排出,消防电梯基坑设置专用排水泵。雨水系统:雨水设计重现期P:展览馆和外博大厦屋面P=20年;室外P=3年。展厅屋面雨水采用压力流虹吸排水系统,并设置满足重现期为50年暴雨的溢流系统。屋面雨水排至室外雨水检查井,道路雨水由雨水箅子收集后排入雨水管道。道路雨水径流时间t=10min,暴雨强度2q=5.67L/(s*100m),室外地面综合径流系数Ψ取0.70,雨水排放量约为4762.8L/s。2.3.1.3消防系统消防用水量见下表。表2.3-1消防用水量计算表用水量标火灾延续消防水量序号系统名称备注3准(L/s)时间(h)(m)由市政给水管网提供,1室外消火栓系统303324不计入消防水池2室内消火栓系统403432大空间智能型主动与自动喷水灭火系统310136喷水灭火系统不同时开启4自动喷水灭火系统27.71100按中危险II级设计5消防水池容积5406展览馆屋顶消防水池容积18本工程设有室内外消火栓系统、自动喷水灭火系统、大空间智能型主动喷水灭火系统、气体灭火系统和手提式灭火器。室外消防用水由市政管网提供,在室外给水管沿消防车道边呈环状布置,共设置12个地上式室外消火栓。展览馆室内消防用水由地下室消防泵房供给,26 广东现代国际展览中心二期扩建工程环境影响报告书33在负二层设置有效容积为540m的消防水池;在屋顶最高处设置有效容积为18m的消防水3箱。外博大厦在天面层设置有效容积为540m的消防水池,25层、50层、75层分别设置有3效容积为30m的消防减压水箱。(1)室内消火栓系统①展览馆室内消防用水由地下室消防水池和消防泵房供给,在负二层设置有效容积为33540m的消防水池;在屋顶最高处设置有效容积为18m的消防水箱。消火栓系统竖向不分区,室内消火栓系统管道成环状布置。在地下二层消防水泵房内设置一套全自动消防稳压设备,含消火栓主泵2台(性能参数:Q=40L/s,H=80kW,N=45kW,一用一备),稳压泵2台(性能参数:Q=4.17L/s,H=84kW,N=11kW,一用一备)和隔膜式气压罐1个。3②外博大厦室内消防用水由天面消防消防水池供给,消防水池有效容积为540m。外博大厦消火栓系统按消火栓栓口的静水压力不大于1.00MPa进行分区。96层~天面层消火栓用水由设于天面消防水泵房内的全自动消防供水设备供给,设备含消火栓主泵2台(性能参数:Q=40L/S,H=40m,N=30kW,一用一备),稳压泵2台(性能参数:Q=4.17L/S,H=45m,N=5.5kW,一用一备)和隔膜式气压罐1个。其余室内消火栓用水由天面消防水池3重力供水,在25层、50层、75层分别设置有效容积30m减压水箱。(2)自动喷水灭火系统2本工程除小于5m的卫生间及不宜用水扑救的场所外,均设置自动喷水灭火系统。22地下车库按中危II级设计,喷水强度8L/min·m,系统作用面积为160m,设计流量227.7L/s,作用时间1小时。其他场所按中危Ⅰ级设计,喷水强度6L/min·m,系统作用面2积为160m,设计流量20.8L/s,作用时间1小时。展览馆在地下二层消防水泵房内设全自动消防供水设备一套,其中喷淋主泵2台(性能参数:Q=30L/s,H=80m,N=37kW,一用一备),稳压泵2台(性能参数:Q=0.667L/s,H=87m,N=2.2kW,一用一备),隔膜式气压罐1个。外博大厦96层~天面层自喷用水由设于天面消防水泵房内的全自动消防供水设备供给,设备含自喷主泵2台(性能参数:Q=20.8L/S,H=40m,N=15kW,一用一备),稳压泵2台(性能参数:Q=0.667L/S,H=45.5m,N=0.75kW,一用一备)和隔膜式气压罐1个。其余室内自喷用水由天面消防水池重力供水。27 广东现代国际展览中心二期扩建工程环境影响报告书展览馆自喷系统报警阀分散设置在各区首层展厅入口附近和地下车库的报警阀室内。从消防水泵房引出两条自喷系统供水主管至各个报警阀室,按控制不超过800个喷头设置一个湿式报警阀。外博大厦报警阀设于地下室、25F、50F、75F报警阀室或消防水泵房内。(3)水泵接合器供水系统100m标高以上楼层消防水泵接合器设转输水箱和转输泵供水。在25F、和75F分别设3置有效容积为45m的转输水箱和转输泵3台。25F消防转输泵性能参数:Q=35L/s,H=245m,N=132kw,二用一备;75F消防转输泵性能参数:Q=35L/s,H=147m,N=75kw,二用一备。(4)大空间智能型主动喷水灭火系统展览馆展厅内的中庭净高大于12m,拟采用大空间智能型主动喷水灭火系统。在中庭上空安装大空间智能型水枪。每具水枪的流量为5L/s,射程为20m,按着火区域同时最多2具水枪喷水考虑,最大用水量10L/s,持续喷水时间按1小时计。在展览馆地下二层消防水泵房内设大空间灭火主泵2台(性能参数:Q=10L/s,H=120m,N=30kw,一用一备)。(5)气体灭火系统设置范围:地下室发电机房、电信机房、网络中心机房、高低压配电房等,采用七氟丙烷洁净气体灭火系统。基本设计参数为:灭火设计浓度为8.5%,灭火浸渍时间大于1min,喷放时间小于等于10s。控制方式:设自动控制、手动控制、机械应急操作三种启动方式。(6)建筑灭火器配置本工程各层均按规范配置手提式磷酸铵盐灭火器,地下汽车库增设推车型泡沫灭火器。2.3.2供电系统电气方案:本工程作为一个现代化建筑群,其电气系统除了为整个建筑提供一个先进、有效的管理平台之外,还应考虑给使用者者提供一个安全、可靠、舒适及融合现代科技信息的工作环境,本工程拟考虑实现以下方案及功能。(1)负荷等级及供电电源①外博大厦属于一级负荷用户。其中设备负荷等级划分如下:28 广东现代国际展览中心二期扩建工程环境影响报告书一级负荷:消防水泵、消防电梯、排烟及正压风机、消防中心、防火卷帘、应急照明等消防用电设备。走道照明、客梯、排污泵、生活水泵、航空障碍照明、安防系统用电、智能化系统设备用电。门厅等场所的备用照明用电,其中,重要的计算机系统和安防系统用电为一级负荷中特别重要负荷(系统设备自备UPS不间断电源装置作应急电源)。二级负荷:办公层照明及小动力、弱电机房机房空调等用电负荷。三级负荷:普通空调、广告及景观照明、泛光照明等其他负荷。②A、B区展览馆属于二级负荷用户,其中设备负荷等级划分如下:一级负荷:消防设备(含消防控制室内消防控制设备、消防泵、消防电梯、防火卷帘、防排烟风机等)、应急照明、通信系统、安防系统、主要通道照明等负荷;二级负荷:生活水泵、客梯电力、普通照明等用电负荷;三级负荷:空调制冷系统、立面泛光、广告及景观照明等用电负荷。供电电源:拟从市政10kV电网不同区域的开关站引来13回路10kV中压电源,其中外博大厦地下一层设一个10kV开关站,五路进线,四用一备;A、B区展览馆地下一层的两个10kV开关站均为三路进线,两用一备;地下二层的一个10kV开关站为两路(空调主机房用电,无备用)。10kV开关站均采用单母线分段方式运行,变电所每二台变压器一组,平时分列运行,低压侧设有联络开关,当其中一台变压器故障时,可通过联络开关保证全部一级和二级负荷供电。此外,项目若无法接上双回路供电系统,则需设置备用发电机,以备紧急停电时使用,设置情况如下:在展览馆东西侧分别设1台功率为1000kVA的备用发电机,均设在独立的设备房,并在发电机房设储油间,储量按照8小时燃油考虑,每个发电机房拟设1立方米的储油间3个。发电机烟气处理后在建筑屋顶层排放。(2)负荷估算根据建筑物功能及相应的建筑面积指标,按负荷密度法计算用电负荷。经估算,工程电气设备设置如下:外博大厦:拟选用28×1600kVA干式变压器。在地下一层K1开关站负责为外博大厦7个变电所共28台变压器的供电。按照安装容量的10%估算发电机容量,拟在地下一层设两台2000kVA发电机组,确保消防用电等一级负荷的运行。A、B区展览馆:拟选用32×1250kVA、4×1600kVA干式变压器。其中地下一层K1开关站负责本建筑东侧B1~B4四个变电所共16台变压器的供电,地下一层K2开关站负责本29 广东现代国际展览中心二期扩建工程环境影响报告书建筑西侧B5~B8四个变电所共16台变压器的供电,地下二层K3开关站负责本建筑制冷机房变电所共4台变压器及10kV制冷设备的供电。按照安装容量的10%估算发电机容量,拟在地下一层每个开关站分别预留两台1000kVA发电机组(共六台)的安装位置,以便在无法取得两路市电时确保消防用电等一级负荷的运行。供配电系统:消防负荷由变电所不同母线段分别引出二路电源(当无法取得两路市电时,其中一段接至发电机应急母线段),并在末端配电箱自动切换;其它一级负荷由变电所不同母线段放射供电(当无法取得两路市电时,由发电机应急母线段引一路电源放射式供电);二级负荷由变电所放射供电,三级负荷采用树干与放射相结合的配电方式。配电系统:(1)动力与照明配电为TN-S系统,电压等级为380/220V。(2)所有导体一律采用铜质。10kV电缆采用低烟无卤耐火交联电力电缆;低压干线采用低烟无卤超A类阻燃辐照交联电力电缆沿电缆桥架敷设;支线采用低烟无卤阻燃导线。消防中心、消防设备配电干线采用矿物绝缘电缆。照明:(1)正常照明:①照明标准根据《建筑照明设计标准》(GB50034-2004)的要求②照明以高效节能型灯具为主,格栅的反射体及表面选用难燃材料,灯具效率不低于65%。荧光灯管或灯盘均须装电子镇流器使功率因数达到0.9以上。光源灯具选择及控制如下:30 广东现代国际展览中心二期扩建工程环境影响报告书表2.3-2光源灯具选择及控制地区光源灯具选择及安装控制方法亮度与时间、智能开关与调光控制相结合办公及公共走廊T5荧光灯或节能灯筒灯(拟采用DALI系统)疏散楼梯吸顶式节能灯红外线感应开关控制(应急时强制亮灯)车库吊式安装的防护式T5单管荧光灯智能控制/手动控制机电设备房挂墙式或吸顶安装的T5荧光灯就地自动控制光敏开关,时间控制器及手动控制,可在变室外见室外照明说明配电值班室内统一控制展览区域由装修定由装修定(2)应急照明①展厅、多功能厅、门厅、走道、楼梯口、变配电房、主要空调机房等的场所设有自带电源的应急照明灯,应急照明最少持续供电时间及最低照度见下表:表2.3-3应急照明最少持续供电时间及最低照度房间或场所对应照度值(lx)应急供电时间(min)一般疏散区域≥0.5≥30竖向疏散区域≥5≥30人员密集流动疏散区域及地下疏散区域≥5≥30消防控制室不低于正常照度≥180变、配电室、发电机房不低于正常照度≥180消防水泵房、消防风机房、消防电梯机房不低于正常照度≥180②本工程拟采用智能疏散指示照明控制系统,智能疏散指示照明控制系统采用集中监控方式,通过自动控制技术对本建筑内的消防安全通道进行实时监控,在获得消防报警火灾联动信息后,对逃生路径进行智能分析,调整疏散方向。消除火灾发生时逃生疏散指示盲区,提高大楼的安全系数。防雷与接地:本工程为大型公共建筑,属于第二类防雷建筑,雷电防护等级定为B级,采取相应的防雷措施。漏电火灾报警系统该系统为独立系统,在低压配电柜内或层间配电箱进线处安装漏电报警探测器,探测漏电电流,发出声光信号报警,准确报出故障线路地址、监视故障点变化。主机安装在消防控制室内,并通过输出端子与火灾自动报警系统连接。电力监控系统及能效管理系统31 广东现代国际展览中心二期扩建工程环境影响报告书本工程电力监控系统设置在负一层的电力监控值班室内。通过本系统对大楼内的高、低压配电系统、直流屏、柴油发电机、变压器温控器等用电设备进行统一监控。实现大楼的电力系统的自动化,提高供配电系统运行可靠性,使物业管理科学化。电力节能措施:(1)根据负荷容量,供电距离及分布,用电设备特点等,合理设计供配电系统和选择供电电压,最大限度的减少线路损耗。变电所及电气竖井位置靠近负荷中心,缩短配电半径,减少线路损耗。同一电压供电系统配电级数不多于三级,并按热稳定要求结合经济电流密度合理选择导线截面。(2)选用低损耗、低噪音的节能高效设备。如变压器选用SCB10型高效节能变压器等。采用无功功率动态补偿及抑制谐波装置,提高功率因数,减少无功损耗。(3)按《建筑照明设计规范》GB50034—2004严格控制照明功率密度值。照明灯具以节能灯及T5型荧光灯及电子镇流器为主,光效高,功率因数高,节约能源消耗。(4)智能照明控制系统分布式智能照明控制系统主要用于对照明灯光系统的控制,通过开关模块、调光模块等可对日光灯、节能灯、石英灯等多种光源开停及调光,对各种场合的灯光进行控制,满足各种环境对照明的要求。(5)配合泛光及LED景观照明,对其实行智能照明控制。(6)配合建筑构思,在允许的情况下采用太阳能光伏发电技术,节约能源。2.3.3空调系统空调方案:空调系统根据建筑物的使用功能及运行管理要求,设2个独立的系统:①A、B区展览馆;②外博大厦。按舒适性空调标准设计,夏季供冷降温除湿,过渡季节视室外气候采用供冷或机械通风方式,冬季不供热,在寒冷时段局部需要供热的房间就地另设热源(如电加热装置)。为建筑物使用人员提供安全、舒适、卫生的环境。项目采用中央空调系统。选用电驱动冷水机组为冷源设备。通过冷水泵、水管网向各层的空调末端设备循环供冷水,由空调末端设备向房间供冷。制冷机房设于地下层。(1)A、B区展览馆建筑物空调冷负荷:52500kW,14950冷吨。32 广东现代国际展览中心二期扩建工程环境影响报告书冷源设备选用水冷离心式冷水机组8台,其中单机制冷量7032kW的6台,单机制冷量4922kW的1台,单机制冷量2813kW的1台,合计制冷量49923kW。冷水进出水温度12℃/7℃。空调送风系统:大面积会展空间采用全空气系统,由柜式空气处理机送风供冷。小面积房间采用风机盘管加新风系统送风供冷。冷水系统采用二管制变流量系统,竖向、水平向采用同程布置,采用一、二次冷冻水泵,二次泵为变频变流量控制。冷却水系统采用机械循环冷却形式,冷却塔设于屋面。冷却水进出水温度37℃/32℃。333冷却塔布置于展览馆A区屋面,冷却塔规格、数量:650m/hx18台,550m/hx2台,400m/hx2台。①新风系统地面以上靠外墙布置的会展区域柜式空气处理机直接从机房外窗吸入室外新风。其他部分每个防火分区设1~2台新风处理机为各个柜式空气处理机、风机盘管提供新风。地面以下每个防火分区设1~2台新风处理机为各个柜式空气处理机、风机盘管提供新风。②排风系统公共卫生间、地下层辅助用房设机械排风系统。地下层汽车库、辅助用房、机电用房:设平时排风系统(与消防排烟系统合用)和补风系统。设空调自控系统对冷水机组、水泵、冷却塔、空气处理机、新风处理机、排风机、排烟风机等设备实现监控,集中对设备的远程监示、测量、控制和运行记录。③消防防排烟系统疏散楼梯间、合用前室设机械加压送风系统。地下层汽车库、机电用房、地下层配套用房、地上无法满足自然排烟条件的房间、走道、中庭设消防排烟系统。(2)外博大厦建筑物空调冷负荷:30200kW,8600冷吨。33 广东现代国际展览中心二期扩建工程环境影响报告书冷源设备选用水冷离心式冷水机组7台,单机制冷量4571kW,6台,单机制冷量2813kW,1台,合计制冷量30239kW。冷水进出水温度12℃/5℃,空调送风系统:大面积空间采用全空气系统,由柜式空气处理机送风供冷。小面积房间采用风机盘管加新风系统送风供冷。冷水系统采用二管制变流量系统,竖向、水平向采用同程布置,采用一、二次冷冻水泵,二次泵为变频变流量控制。水系统竖向分为低、中、高区,分别在避难设备层设板式热交换器转换。冷却水系统采用机械循环冷却形式,冷却塔设于裙楼屋面。冷却水进出水温度37℃/32℃。33冷却塔布置于裙楼屋面,冷却塔规格、数量:600m/hx12台,350m/hx2台。①新风系统裙楼靠外墙布置的会展区域柜式空气处理机直接从机房外窗吸入室外新风。其他部分每个防火分区设1~2台新风处理机为各个柜式空气处理机、风机盘管提供新风。地面以下每个防火分区设1~2台新风处理机为各个柜式空气处理机、风机盘管提供新风。塔楼在设备避难层新风机房(2个)设柜式新风处理机,新风经新风处理机降温除湿处理后,通过竖向管井,直接送至各房间内。②排风系统公共卫生间、地下层辅助用房设机械排风系统。地下层汽车库、辅助用房、机电用房:设平时排风系统(与消防排烟系统合用)和补风系统。塔楼卫生间设天花式排气扇,将排风排入竖向管井内的排风管,集中由设备避难层柜式排风机排至室外。设排风机房2个。设空调自控系统对冷水机组、水泵、冷却塔、空气处理机、新风处理机、排风机、排烟风机等设备实现监控,集中对设备的远程监示、测量、控制和运行记录。③消防防排烟系统疏散楼梯间、合用前室设机械加压送风系统。地下层汽车库、机电用房、地下层配套用房、地上无法满足自然排烟条件的房间、走道、中庭、避难层设消防排烟系统。34 广东现代国际展览中心二期扩建工程环境影响报告书2.3.4燃气系统本项目不设餐饮,办公人员的就餐均依托附近的餐饮业解决。因此本项目无燃气系统,也不预留餐饮业专用烟道。2.3.5通信系统1、电话通信系统(1)给水系统各区范围内设电话配线间。(2)办公及展览区分别设配线架。2、有线电视系统本区接入东莞市有线电视网,接受全部有限电视台节目频道的广播。2.3.6景观考虑到展览中心的建筑特性,景观设计主要以硬质铺地为主,满足大规模人流的疏散要求,在展馆周边设置绿化隔离带,在展馆天面局部设置绿化屋面,形成多层次的绿化环境空间,提升展览馆的空间品质。2.3.7交通组织(1)外部交通组织总体交通流线设计以“区域性人车分流”为原则,各流线互不干扰、便捷通达。轨道交通:在外部流线上,通过地铁R2线往来的人流从东面进入展馆区,先到达广东现代展览中心展览馆,然后再到达各分期展馆;通过轻轨(即穗莞深城际轻轨)往来的人流在会展南路方向进入展览馆。公交车:在二期扩建工程A区展览馆的北面和三期待建展览馆的南面分别设有大型的公交枢纽,满足整个展览中心的公交通行要求。出租车:在二期扩建工程A区北面和在三期待建展览馆南面设置出租车站场,方便观展人流。社会车辆:将地下车库的出入口布置在靠近道路的地方,使其一进入基地就引向北面的地下车库和南面的停车楼,减少对城市交通的影响。35 广东现代国际展览中心二期扩建工程环境影响报告书货运车流:利用会展南路和康乐西路组织货流车辆,减少对家具大道及其他主要干道的影响。展览的性质为常年展,展品更换频率低,展览馆主要利用新建的规划道路作为展品的进场、离场通道,利用分时段进场的方法,在观展开放前或观展结束后进入场区。消防车流:由于新建的展览馆均为高层建筑,且规模较大,在消防设计中均考虑消防车道环通,并在A、B区展览馆之间的一层中部设置可东西向穿行的紧急消防车道,确保整体的安全性。每个展览馆四周均为消防扑救面。停车系统:车辆停放主要考虑观展便利性的提升和对城市交通的干扰尽量降低。设计中提供两种途径,一种是直接进入负一层和负二层地下车库,通过电梯、扶梯进入观展;另一种是停放在B区的停车楼,可以便利地通达各层平面。(2)建筑内部交通分析A、B区展览馆主要通过三条南北向的通廊和各端部的交通核来组织馆内的交通流线。在水平方向上,设置环通走廊,让参观者可以顺着流线浏览全部展位。在竖直方向上,沿着中庭空间设置多部自动扶梯和观光电梯,将各层展览空间联系起来。在安全疏散方面,在每个防火分区内设有至少四个直通室外或准安全区的疏散楼梯间。楼梯间均匀布置,保证疏散的导向性。2.3.8智能化方案(1)火灾自动报警及联动控制系统(FAS)系统通过对火灾产生因素的监控,防止和减少火灾危害,保护建筑内人身和财产安全。本系统按火灾报警系统特级保护对象设计,采用控制中心报警系统。地下一层或首层设消防安防控制室,消防安防控制室内置火灾自动报警控制、消防联动控制装置、彩色图形显示装置、消防专用电话总机、火灾应急广播控制盘、漏电报警控制装置,负责整个建筑内的火灾报警信号、消防设备的集中监控和消防指挥。本工程选用智能型火灾自动报警控制器和联动控制装置,火灾报警控制器的报警/控制回路采用环型总线连接方式。(2)公共/应急广播系统系统为给用户营造一个愉快的气氛,并及时把各种信息、应急事件传达给用户。公共广播兼作应急广播,属于以语言广播为主,播放背景音乐为辅的具有多个业务播点的综合系统,采用集中控制,分区播放的方式。系统把音乐广播、业务性广播、呼叫广播和应急广播有机36 广东现代国际展览中心二期扩建工程环境影响报告书地结合在一起,具有优先控制、分区选择、故障检测与自动功放备份等功能。系统要求有足够的声压级,声音应清晰,声场应均匀。(3)综合布线系统建筑利用综合布线系统作为实现各种语音、图像、数据、控制信号和多媒体信息交换传递的基础。综合布线系统应满足开放性、灵活性、可扩展性、实用性、安全性、可靠性和经济性的要求,综合布线系统呈现二级星拓朴结构,内设BD(建筑物配线架)、FD(楼层配线架)、TO(工作区的信息插座)。各种的通讯运营商从双路由接入管道引入室外单模光纤至BD,从BD到FD光纤主干采用室内50/125微米12芯万兆多模OM4光纤,语音主干采用三类大对数铜缆。从FD到TO采用低烟无卤阻燃型非屏蔽六类双绞线作为传输介质。本工程的通讯网络和计算机网络均纳入综合布线系统,根据用户的需要设置为语音或数据接口。(4)通信系统通信系统是为满足用户对通信容量的需求,为用户提供方便、快捷、高效、可靠的通信服务。通信系统分为固定通信系统、移动通信系统。固定通信的设备放置在电信机房内,电话交换机拟采用数字程控交换机。固定通信网络纳入综合布线系统。移动通信系统是指手机用户的无线网络的覆盖系统,地下层设有电讯机房,分别提供给移动运营商、联通运营商、3G运营商等使用。(5)计算机网络系统计算机网络系统能为管理者及各个使用者提供高速、可靠、安全、有效的信息服务。本建筑网络系统物理功能上分为二个层次,即核心层和接入层组成。核心交换机置于网络中心机房,接入交换机置于各层的弱电间。本工程网络设置根据使用功能和特点划分为3个物理分隔的部分:智能网:供建筑物内的智能化系统使用;办公网:供内部的办公使用;公众网:提供INTERNET网络访问服务使用;(6)安全防范系统系统采用集成式联网型安全防范系统,控制中心设在消防安防控制室内。系统由视频安防监控系统、出入口控制系统、入侵报警系统、电子巡查系统、无线对讲系统、停车场管理系统等子系统和安防信息综合管理系统组成。安防信息综合管理系统通过统一的系统平台将安全防范各个子系统联网,实现控制中心对整体信息的系统集成和自动化管理,及时、准确37 广东现代国际展览中心二期扩建工程环境影响报告书地发现各种不安全因素的存在和判断其发展的趋势,快速、有效地消除不安全因素和控制其发展。(7)避难救灾设施在外博大厦超高层的25、50、75层设避难层、102层屋顶设停机坪等避难救灾设施。2.4土石方工程3根据本项目的水土保持设计方案及批复,项目施工过程中,总挖方103.24万m,总填33方13万m,总弃方90.24万m。东莞市厚街镇汀山社区居民委员会根据木材交易市场工程3建设的需要,需回填土石方180万m,本项目的弃方全部运至厚街镇汀山社区木材交易市场工程回填利用,双方已签订协议,详见附件。弃土点位于汀山区东埔小组(当地地名:横水埔)。目前挖方后供自身回填利用的部分暂时存放在三期地块。2.5建设周期项目A区展览馆于2012年3月动工建设,目前基坑已开挖完毕,整体工程计划于2015年2月竣工,共计36个月。2.6一、二期工程回顾2.6.1一、二期工程建设内容回顾2广东现代国际展览中心一期工程总投资2900万元,建设规模为45000m的展览馆,于2002年1月启动建设,2003年5月建成投入试运行,其环境影响报告表于2002年2月由广东工业大学编制完成,并于2002年3月1日获得东莞市环境保护局厚街分局同意其建设的审批([2002]391号)。项目属于生态影响为主类型的项目,经江西省气象科学研究所进行竣工验收调查后,于2008年5月通过了东莞市环境保护局的竣工验收,取得验收意见(东环建[2008]30590号)。广东现代国际展览中心二期工程总投资15000万元,主要建设A、B、C、D四个展馆,2计容积率建筑面积为60563m,.2007年2月10日开工建设,于2008年4月建成投入试运行,其环境影响报告表于2008年5月由江西省气象科学研究所编制完成,并于2008年738 广东现代国际展览中心二期扩建工程环境影响报告书月获得东莞市环境保护局同意其建设的审批([2008]1583号)。项目属于生态影响为主类型的项目,经广西壮族自治区环境保护科学研究院进行竣工验收调查后,于2008年8月通过了东莞市环境保护局的竣工验收,取得验收意见(东环建[2008]31257号)。2.6.2一、二期工程投入使用情况及可为本项目依托的内容从上面可见,广东现代国际展览中心一、二期工程的主要建设内容均为展览馆,其可为本项目依托的内容如下:由于一、二期已建成,其基础设施已经建成,为本次二期扩建部分奠定了基础,水、电、交通等均比较方便接入;一、二期展馆已形成一定的规模,本次二期扩建部分的展馆,在平时将主要为商贸性质;由于一、二期展馆已经建成,将有利于本次扩建的外博大厦引入相关的参展单位及同行业相关企业入驻。2.6.3一、二期工程环境影响回顾性评价根据一、二期工程的建设内容及环境影响评价、批复及竣工验收调查报告可知,广东现代国际展览中心一、二期工程的主要环境影响是办公人员及参展人员的生活污水、由于展览引起的交通流的增加而导致的汽车尾气的影响、参展人员的社会生活噪声以及办公生活垃圾等。根据一、二期的规模,其环境污染物产生和排放情况如下:表2.6-1一、二期工程运营期污染物产排情况污染物类污染物排放源处理前处理后措施及排放去向型名称一期:食堂油油烟通过净化处3烟、车辆尾CO、一期:油烟12mg/m,3大气污染一期:油烟2mg/m,理后有组织排气;NOx、油0.24t/a;物0.04t/a;放;车辆尾气无二期:车辆尾烟组织排放向大气气一期:污水量1600t/a,一期:污水量1600t/a,COD0.32t/a,,COD0.24t/a,,BODCOD、BOD0.16t/a;0.08t/a;BOD、二期:污水量二期:污水量水污染物生活污水市政管网33SS、氨3680.26m/a,COD3680.26m/a,COD氮0.92t/a,BOD0.552t/a,0.736t/a,BOD0.441SS0.552t/a,氨氮0.092t/a,SS0.441t/a,氨氮t/a。0.0736t/a。39 广东现代国际展览中心二期扩建工程环境影响报告书冷却塔、风采取基础减震、机、水泵等设厂界昼间≤60dB(A),噪声LeqA60-90dB(A)隔声降噪措施后备、车辆、人夜间≤50dB(A)厂界达标员活动生活垃圾由环一期:办公生活垃圾一期:办公生活垃圾卫部门运至垃圾固体废弃办公生活垃25t/a、包装废物30t/a;25t/a;填埋场;包装废物圾、包装废物二期:办公生活垃圾二期:办公生活垃圾物全部外售回收64.5t/a、包装废物50t/a64.5t/a。利用从上表可见,由于一、二期工程的建设内容比较单一,其污染物排放情况比较简单,主要为生活污水,经过化粪池处理后排入市政管网进入污水厂进行处理,对水体的影响较小。大气污染物一期主要为食堂油烟和车辆尾气,而二期仅有车辆尾气,由于食堂仅为办公人员服务,其规模比较小,油烟排放量较小,对大气影响不大;由于展览馆有一定的周期性,在平时车辆较少,影响较小,而在展会期间,会吸引到大量的客户前来,期间车辆尾气影响较大,但是影响时间较短,一般极限展会仅三天左右的时间,必须在该期间对车辆进行适当的疏导,采取一定的管理措施。项目已经聘请相关部门对极限展会情况下的交通影响进行评价,并采取了一定的措施,在后面低7.7章节将详细分析。展览馆的噪声源主要为冷却塔、风机、水泵等设备和人员活动的社会生活噪声,项目一、二期工程对各类设备采取了一定的减震降噪措施,其影响不大,但是在极限展会情况下,由于大量大流的到来,使得区域内社会生活噪声加大,在对相关人员进行适当的疏导和管理后,对外界影响不大。项目一、二期固体废弃物主要是生活垃圾和包装废物,其中生活垃圾通过市政部门清运至当地垃圾填埋场进行处置,而包装废弃物则通过集中收集后由相关回收部门回收利用,影响不大。对照项目的环评批复及验收意见,项目已经落实了相关环保措施,并且项目一、二期工程自从建成运营至今,未受到附近任何投诉,可见,其影响已经得到控制。广东现代国际展览中心一期、二期、二期扩建及三期的分期建设图见附图2.6-1,总平面布置见附图2.1-4。40 广东现代国际展览中心二期扩建工程环境影响报告书第3章工程分析3.1工艺流程分析本项目工艺流程见图3.1-1。场地清理土石方工程基础工程结构施工W1、G1、G5、W1、W2、G1、G5W1、W2、G1、G5W1、W2、G1、D1、N1、S1、S2D1、N1、S1D1、N1、S1G5、D1、N1、S3、ES2、S3、E、J1S2、S3、J1S1S3外界污染源装修工程工程验收运营使用G6、N3、Z1、W1、G2、G5、D1W3、G3、G4、S4、S5、N1、S1、S3J2、R1、R2W:废(污)水(W1施工期生活污水,W2施工期生产废水,W3运营期生活污水);G:废气(G1施工期机械废气,G2施工期装修废气,G3停车场废气,G4备用发电机烟气,G5餐饮油烟、G6外环境废气)D:D1施工期粉尘N:噪声(N1施工期噪声,N2运营期噪声,N3运营期外环境噪声)S:固体废物(S1施工期生活垃圾,S2弃土,S3弃渣,S4运营期生活垃圾,S5运营期商业垃圾)E:水土流失Z:振动(Z1地铁、城市轻轨)J:景观R:R1光污染,R2日照影响图3.1-1本项目工艺流程图3.2环境影响识别项目具有一定规模,其开发和营运过程对城市生态环境可产生一定程度的影响。3.2.1施工期影响识别地表水环境影响因素识别项目施工期水环境影响因素主要包括施工人员产生的生活污水、施工废水。施工人员生活污水主要来自施工营地施工人员生活产生的废水,废水中水污染物主要为CODCr、BOD5和NH3-N;施工废水主要包括开挖和钻孔产生的泥浆水、机械设备运转的冷却水和洗涤水、混凝土搅拌车及输送系统冲洗废水、车辆清洗水、开挖基础时为降低地下水位的排水和地下涌水等,施工废水含有大量的SS,若不进行处理,会对地表水环境产生一定影响。41 广东现代国际展览中心二期扩建工程环境影响报告书地下水环境影响因素识别项目施工期开挖地下室为降低地下水位会抽排地下水,开挖过程中也可能产生一定的地下涌水,可能会造成局部地下水位下降;另外,地下涌水如未及时排出,可能会给污染物(主要为SS和油类等污染物)进入地下水提供通道,从而污染浅层地下水。项目施工期生活污水和施工废水可能渗入地下,造成地下水水质污染。声环境影响因素识别项目施工过程中施工设备、运输车辆噪声将对区域声环境产生一定的影响。大气环境影响因素识别在施工过程中,由于土石方开挖、运输等将产生一定的扬尘;场地地表裸露也将引起风力扬尘;施工机械运行、土石渣料及原材料运输汽车也将产生一定的燃油废气;临时施工营地设有临时食堂,产生油烟废气;在装修过程中也将产生一定的废气。施工扬尘和食堂油烟废气为施工期主要大气环境影响因素。固体废物环境影响识别项目施工期的固体废弃物主要有施工产生的建筑垃圾、弃土方以及施工人员的生活垃圾,若处理不当,可能会造成水土流失、污染环境等环境影响。生态影响因素识别项目用地范围在未施工前主要为空地,工程占地将改变土地利用类型;项目地块内有一定的植被覆盖度,植被类型以野生灌草丛为主,工程施工将破坏用地范围原有生态系统结构,促使生态系统类型由陆域自然生态系统向城市人工生态系统转变;工程施工破坏植被,使生态系统功能状况发生改变,施工期间若不采取相应的水土保持措施,可能会引起大量的水土流失;工程施工将会使项目所在地块与周边环境景观协调一致性降低。项目地块内无珍稀濒危物种和受保护野生动物,可能有一些鼠类、蟾蜍等爬行类动物,工程施工期会扰动地表,破坏项目地块原有生境,另外施工人员进驻也会使爬行动物生活受到干扰,部分会向其它地方迁徙。景观影响识别项目在施工会造成大面积裸露地表,且部分由于结构疏松,空隙度较大,如果不采取有效的美化和拦挡措施,雨天将会产生大量污泥、荒水;晴天运输建材往来的车辆将会产生大量的扬尘,污染空气,对附近的敏感点生活、生产也有较大影响;同时,裸露的施工点形成的大型黄土斑块影响景观,与周围景观协调一致性降低,造成区域景观美感降低。42 广东现代国际展览中心二期扩建工程环境影响报告书3.2.2运营期影响识别地表水环境影响因素识别本项目运营期的办公、展览将产生生活污水,其COD、BOD含量较高,若不达标排放,将会给周边地表水水质带来一定程度的影响。地下水环境影响因素识别本项目运营期污水经过化粪池处理后排入市政污水管网。类比同类型化粪池,化粪池将采用防渗措施,一般情况下化粪池跑冒渗漏的可能性较小;且项目所在地透水性和富水性较弱,地下水主要为基岩裂隙承压水,项目场地包气带污染性能弱,对地下水基本无影响。雨水经过项目区雨水管网收集后进入雨水收集池回收利用,不可利用部分进入市政雨水管网,不会对地下水造成影响。环境空气影响因素识别本项目运营期的环境空气影响源主要为地下车库产生的废气、备用发电机的废气、垃圾站臭气。将会对项目内外局部环境空气造成不同程度的污染。声环境影响因素识别本项目运营期使用的配套设施(水泵、风机、备用发电机、冷却塔等)及展厅运营时产生的噪声不经治理,将会对项目内外声环境造成一定的影响。展览、办公等进出地下停车场的车辆噪声对办公人员造成的影响。固体废物环境影响因素识别运营期固体废弃物主要是生活垃圾、商业垃圾等。生活垃圾日产生量较大,成分复杂,应纳入城市生活垃圾收运体系,妥善处理,及时收运,以免对环境造成不良影响。其它影响因素识别外博大厦建筑楼层较高,外部采用玻璃幕墙装饰,对周边环境带来高楼风、日照、光污染、景观等一系列的影响。3.2.3外环境影响因素识别由于项目建设内容包含展览馆、外博大厦,考虑到建筑物建成后的使用功能,本报告重点关注外环境对外博大厦办公人员的影响。外环境污染源见附图3.2-1。43 广东现代国际展览中心二期扩建工程环境影响报告书周边工业对项目的影响项目建设地点位于东莞市厚街,项目北面、东面多为工业企业,项目东面工业企业类型有制鞋厂、化工厂、石材厂、家具厂等,北面主要有制鞋厂、家具加工厂等,工业企业生产过程中产生的废气将对项目产生一定影响。周边道路对项目的影响项目周边道路情况见下表:表3.2-2项目周边道路信息红线或路幅宽度车道数外博大厦建筑红线与道路项目用地红线与道路名称道路等级(m)(双向)中心线/道路边界距离道路边界距离省道S256省道508东400m/380m东377m家具大道城市主干路486北65m/40m北6.4m会展南路城市次干路214南366m/355m7.5m周边道路车辆行驶过程中产生的交通噪声、汽车尾气将会对项目产生影响。规划中轨道交通对项目的影响穗莞深城际轨道沿东溪路-莞太路从项目地块南侧地下通过,并在仁康医院南侧设厚街站(地下站)。目前该工程已在建,预计2013年底实现通车。轨道交通R2线(即地铁2号线)沿S256从项目东侧地下通过,并在现状的广东现代国际展览中心设置展览中心站,目前该工程已经在建,预计2015年全线通车。表3.2-3项目周边轨道交通信息轨道交通名称道路等级与项目周边地块跨越方式与本项目(外博大厦)的位置关系穗莞深城际轨道城际轨道地下南侧570m轨道交通R2线城市轨道地下东侧380m(即地铁2号线)建成后列车通过时,将对项目产生振动、噪声、废气等方面的影响。地面停车场交通噪声、汽车尾气对项目的影响根据《东莞市厚街镇会展片区控制性详细规划》,项目地块西北面设置为地面停车场,供大巴、出租车上下客。该停车场仅在会展期间使用,与周边城市道路及项目地下车库相比,其带来的交通噪声、汽车尾气影响较小,报告中不作详细分析。3.3污染源分析3.3.1施工期污染源分析3.3.1.1废(污)水污染源44 广东现代国际展览中心二期扩建工程环境影响报告书施工废水施工过程中产生的施工废水主要来自于开挖和钻孔产生的泥浆水、开挖地下室的抽排水和地下涌水等,施工机械设备和运输车辆的定期清洗也产生少量废水。施工生产废水的特点是悬浮物含量高,含有一定的油污,据类比调查,施工污水的悬浮物浓度约为1500~2000mg/L。施工生活废水根据项目施工计划,预计项目施工大约需要工人400人/d,施工人员生活用水以330.1m/d·人计,生活用水量为40m/d,生活污水按用水量的80%计,则生活污水的排放量3为32m/d,项目施工期约36个月,总施工天数1080天计,则施工期生活总用水量为3343200m,生活污水的排放量为34560m。根据类比调查,施工期生活污水中污染物浓度约分别为CODCr约400mg/L、BOD5约200mg/L、SS约220mg/L、氨氮约25mg/L。预测出施工期的生活污水的污染负荷,其结果列于表3.3-1。表3.3-1项目施工期生活污水污染负荷污染因子类别CODCrBOD5SSNH3-N排放浓度(mg/L)40020022025产生量(kg/d)12.86.47.040.8总产生量(t/施工期)13.86.97.60.863.3.1.2大气污染源施工扬尘(1)场地内扬尘施工期场地内扬尘主要由以下因素产生:a)施工场地内地表的挖掘与重整、土方和建材的运输等。b)干燥有风的天气,运输车辆在施工场地内的道路和裸露施工面行使。2.参考其他同类型工程现场的扬尘实地监测结果,TSP产生系数为0.05~0.10mg/ms,根2.2据本项目区域的土质特点,取0.07mg/ms,本项目建筑占地面积约为64571m,日工作12小时,则在不利天气条件下,项目施工场地扬尘的产生量约为198.2kg/d。(2)场地外扬尘对于被带到附近道路上的泥土所产生的扬尘量,与管理情况关系密切,一般难以估计。施工废气45 广东现代国际展览中心二期扩建工程环境影响报告书本项目施工过程用到的机械,主要有挖掘机、装载机、推土机、平地机等,它们以柴油为燃料,都可以产生一定量废气,包括CO、NOx、SO2等,考虑其量不大,影响范围有限,故可以认为其环境影响比较小。在后面的评价中也不再予以考虑。临时食堂油烟废气和燃料废气本项目在施工期会在现场设置临时工地,施工人员在场地内食宿,设置临时食堂,其在炊事过程中的油烟产生量及排放量依据类比调查来确定。调查菜谱主要为大排、鱼、肉沫、豆制品等各种蔬菜,制作工艺分炸、煎、煮、炒等,根据对饮食餐店所作类比调查,每月的物耗情况见表3.3-2,类比调查厨房油烟测试工况及监测结果(类比数据引用原《东莞凤岗(惠东)产业转移园环境影响报告》,广州市环科所,2006年)表3.3-3。表3.3-2饮食餐店每月物耗汇总表单位:kg各类蔬食用油大排鱼肉沫用餐人数(人/d)菜6001000575225300030008001500120040070004000表3.3-3监测工况工况炒菜(15min)煎(20min)炸大排(32min)监测耗油量(g)300020001300采样时间(min)56.722.63排风量(m/Nh)340031703670油烟浓度182.924.699.03(mg/m)油水排放量(g)48.335.134.2油排放量(g)34.219.320油的挥发率(%)3.412.82.3本项目临时食堂就餐人数约为400人,根据表3.3-2的类比数据可知,本项目施工期临时食堂年耗食用油量约为80kg/月,即960kg/a。由表3.3-3可见,不同的烧炸工况,油烟气中烟气浓度及油的挥发量均有所不同,平均而言,油烟和油的挥发量占总耗油量的2~4%之间,取其平均值2.83%,则本项目施工期临时食堂油烟产生量约为27.2kg/a。46 广东现代国际展览中心二期扩建工程环境影响报告书按日最高峰2小时计,则高峰期产生油烟中的油量为0.0375kg/h,油烟气排放量约为336000Nm/h。产生的油烟废气中油烟浓度为6.25mg/Nm,采用静电装置进行处理后,油烟浓3度低于2mg/m以下,排放的油量低于0.012kg/h,即8.64kg/a。项目油烟产生及排放情况见表3.3-4。表3.3-4项目餐饮企业食用油消耗和油烟废气产生及排放情况表年使用天数耗油量油烟挥油烟产生量油烟排放量类型就餐人数(天)(kg/a)发系数(kg/a)(kg/a)临时食堂4003609602.83%27.28.64此外,项目临时食堂采用液化石油气作为燃料,其燃烧过程中也产生一定的烟气,由于液化石油气属于清洁能源,其燃烧过程中产生的烟气污染物量较小,而且施工期临时食堂规模较小,属于临时性质,本评价对其不做定量预测。装修废气本项目的建设内容包括展览馆、办公写字楼、地下室等,装修阶段将使用大量的建筑材料,这些装修材料会产生一定量的废气,主要污染物为挥发性有机化合物(VOC)、甲醛、氨气等。3.3.1.3噪声源强施工期噪声主要有施工运输车辆噪声和建筑施工噪声两类。本项目建筑施工分为4个阶段,即土方阶段、基础阶段、结构阶段和装修阶段等。每一阶段所采用的施工机械不同,对外界环境造成的噪声污染水平也不同。其中,本项目基础不采用桩机基础,而是采用天然基础,大大降低了基础阶段的噪声。各不同阶段使用的常见设备的噪声源强参见表3.3-5。表3.3-5建筑施工机械的噪声源强施工阶段机械名称离声源距离/m噪声级dB(A)东风195翻斗车380.775马力推土机385.5土方阶段德VB挖掘机583.6ZL-20装载机583.716吨汽车起重机1571.5混凝土搅拌车490.6混凝土搅拌泵车883基础和结构阶段TW375浆式搅拌机271.850mm振捣棒287电锯1103柴油发电机29547 广东现代国际展览中心二期扩建工程环境影响报告书施工阶段机械名称离声源距离/m噪声级dB(A)砂轮锯386.5切割机188磨石机182.5卷扬机184装修阶段木工电锯1103.0木工压刨290木工平刨285外用电梯583注:资料引自“马大猷《噪声与振动控制工程手册》(机械工业出版社2002.9)”3.3.1.4固体废弃物建筑垃圾采用建筑面积发展预测,预测模型为:JQCSSS式中:JS—年建筑垃圾产生量(吨),2QS—年建筑面积(m),2CS—平均每平方米建筑面积垃圾产生量(吨/m)。由于CS值与施工水平、建筑类型等因素有关,本建筑主要为多层民用住宅,根据同类项22目经验,CS取值为40~50kg/m,本次评价取CS=50kg/m进行估算,本项目总建筑面积为2714767m,则项目施工期产生建筑垃圾约为3.57万t。项目二期扩建工程完成后,原二期工程建设的展览馆A馆将拆除改建为休闲广场,将产22生一定的拆除垃圾,该馆建筑面积约为18990m,按每1m建筑面积产生0.368吨的建筑垃圾计算,则拆除所产生的垃圾为6988.3t,约为0.7万吨。即建筑垃圾产生量共为4.27万吨。此外,建设期产生的固体废物还包括建筑施工的废料和包装材料等,其中的废弃油漆桶、天那水包装物、废涂料等属于危险废物。生活垃圾本项目施工人数按400人计,施工人员人均生活垃圾产生量为1kg/人·天,则日产生生活垃圾量为0.4t/d。按年施工360天计算,则年生活垃圾产生量144t/a。工程弃土工程弃土一般来自场地平整和基础施工阶段地下空间的开挖。项目开挖土石方约103.24333万m,其中自身回填利用13万m,剩余土石方90.24万m全部外弃。弃土全部运至厚街镇汀山社区木材交易市场工程场平回填利用。48 广东现代国际展览中心二期扩建工程环境影响报告书3.3.2运营期污染源分析本项目的特点人多、流动性大,活动时间不稳定。展览中心的建设功能一般是满足大型展览活动,作为展览使用时间集中,人流比较集中,所以污染物的产生也比较集中。项目建成投入使用后对周围环境可能产生影响的主要因素有:展厅参展人员、办公人员的生活污水;外博大厦办公人员的生活污水;发电机尾气、地下车库汽车尾气;水泵房、机动车、备用发电机、冷却塔等噪声;生活垃圾、办公垃圾等。3.3.2.1水污染源分析项目所排污水主要为展厅参展人员、办公人员的生活污水;地下车库冲洗废水,冷却塔排水。根据《广东省用水定额(试行)》及项目有关的设计文件对项目的用水量进行计算,根据《排水工程》,一般生活用水排污系数按0.8-0.9进行计算,本评价取0.9计,由于地下车库地面冲洗时,损耗较大,本评价对其排污系数取0.7进行计算。项目展览馆和外博大厦用水和污水排放情况分别见表3.3-6和表3.3-7,总的用水和污水排放情况见表3.3-8。49 广东现代国际展览中心二期扩建工程环境影响报告书表3.3-6展览馆用水量计算表序使用时间3333用水部位用水标准用水单位数日最高用水总量(m)年用水天数(d)年用水总量(m)排放系数日最高排水量(m)年排水总量(m)号(h/d)1展厅工作人员50L/d·人310人/d1015.536055800.914.050402展厅参观人员25L/d·人20000人/d105003601800000.94501620002.3L/md(每周139535.83地下车库冲洗水859.8(平均到每天)365217680.741.9152372冲洗一次)m224绿化用水1.3L/m·日15738m820.5250512500035冷却塔补水127m/h101270360457200000不可预见用水(按上述污水总量15%计)279.93651004510.9251.990405.9小计2145.7/770124/757.8272682.9表3.3-7外博大厦用水量计算表序用水单位使用时间日最高用水总量日最高排水量33用水部位用水标准年用水天数(d)年用水总量(m)排放系数年排水总量(m)33号数(h/d)(m)(m)1外博大厦办公人员50L/d·人11433人/d10571.73602058120.9514.518522023L/m.d(每周22地下车库冲洗水29877m812.8(平均到每天)3654673.60.793271.5冲洗一次)223绿化用水1.3L/m·日2520m83.325082500034冷却塔补水80m/h8640360230400000不可预见污水(按上述污水总量15%计)184.2/66256.60.9165.859630.9小计1412/507967.2/689.3248122.450 广东现代国际展览中心二期扩建工程环境影响报告书表3.3-8项目总用水量、总排水量总用水量总排水量排放去向项目3333(m/d)(m/a)(m/d)(m/a)展览馆2145.7770124757.8272682.9外博大纳入市政管网,进入市政污水处理厂1412.0507967.2689.3248122.4厦处理。合计3557.71278091.21447.1520805.333上表可计算出项目最大总用水量约为3557.7m/d,项目外排污水量为1447.1m/d。项目水平衡见图3.3-1。51.5515.5464展厅人员生活用水57.2571.7514.5外博大厦办公生活用水化1396.2粪池46.4市市政给水464.1417.7政不可预见部分污水管21.7网3557.772.650.9地下车库冲洗隔油1447.11910冷却塔补水厚街沙塘污水处理厂23.8绿化东莞运河市政给水图例污水损耗3图3.3-1水平衡图(单位:m/d)建设项目生活污水经三级化粪池预处理达到《水污染物排放限值》(DB44/26-2001)第二时段三级标准后排放入市政管网,接入东莞市厚街沙塘污水处理厂处理达标后排东莞运河。根据东莞市现有同类型项目生活污水的类比监测结果,项目污水的污染物产生和排放情况见表3.3-6所示。51 广东现代国际展览中心二期扩建工程环境影响报告书表3.3-6污水主要污染物产生和排放情况表33项目(污水量1447.1m/d,520805.3m/a)CODcrBOD5SSNH3-N浓度mg/l40020022025预处理前产生量t/a208.3104.2114.613浓度mg/l34018215424.3预处理后排放量t/a177.194.880.212.7浓度mg/l6020208污水处理厂出水*排放量t/a31.210.410.44.2注:(1)本项目以生活污水为主,车库地面冲洗水较少,汇入后对总的污水中污染物浓度影响不大,本报告以总的浓度为中等生活污水进行计算;(2)三级化粪池的去除率,一般是COD15%,BOD9%,SS30%,氨氮3%。*污水处理厂处理后污水浓度按《城镇污水处理厂污染物排放标准》(GB18918-2002)一级B标准执行。3.3.2.2废气污染源分析项目竣工投入使用后,其废气污染源有:地下车库汽车尾气、备用发电机尾气等,废气中主要污染物为油烟、SO2、NO2等。1、备用发电机尾气本项目不一定设置备用发电机,如果设置的话,将考虑在展馆两侧各设置一台1000kVA的备用柴油发电机,均设在专门的设备房。柴油发电机燃料拟采用含硫率小于0.2%的优质轻柴油,为保证发电机处于良好备用状态,每月试机时间按8小时计,全年最多工作96小时,按单位耗油量220g/kW·h计算,则发电机全年耗油量42.24吨,燃油烟气中主要污染物的产生排放情况见表3.3-8。根据《环境统计手册》(方品贤等著),计算燃油发电机排放的主要大气污染物方法如下:燃烧柴油主要污染物排放量:QSO2=20×S×W/ρQNO2=8.57×W/ρQ烟尘=1.8×W/ρ式中:Q—污染物排放量(kg);S—含硫率(%);W—耗油量(t);ρ—燃油密度,0#柴油取0.86。经计算,建设项目的大气污染物产生量可见下表3.3-8。52 广东现代国际展览中心二期扩建工程环境影响报告书表3.3-8建设项目发电机尾气污染物产生一览表排放源污染物产生量(kg/a)产生量(kg/h)排气筒高度(m)SO298.2331.023展览区备用发电机NO2210.4632.192一1000kW烟尘44.2050.460SO298.2331.023展览区备用发电机43m(高出展览馆楼顶NO2210.4632.192二1000kW5m排放)烟尘44.2050.460SO2196.4662.046合计NO2420.9264.384烟尘88.41.0.922、车库机动车尾气C区停车场负二层到四层为立体停车库,其余均为地下车位。机动车尾气由三部分组成,一是汽车排气管排出的含有CO、HC、NOx等污染物的内燃机燃烧废气,约占总排放量的60%;二是曲轴箱排出的含CO、CO2气体,约占20%;三是从油箱、气化器燃烧系统蒸发出来的HC等气体约占20%。机动车尾气所含成分比较复杂,但排放的主要污染物为CO、HC、NOx等。(1)单车排放因子汽车单车排放因子是源强模式中最重要也是最难准确估算的参数。我国有关汽车尾气排放限值,将汽车分为轻型车和重型车两类。其中《轻型汽车污染物排放限值及测量方法》的计量是以汽车发动机单位行驶距离的排污量(g/km)计算,《重型车用汽油发动机与汽车排气污染物排放限值及测量方法(中国III、IV阶段)》(GB14762-2008)的计量是以汽车发动机单位功率的排污量(g/kwh)计算。交通部《公路建设项目环境影响评价规范(试行)》(JTGB03-2006)中有关汽车尾气排放因子将汽车分为大、中、小三类,各类型车排放因子均以汽车发动机单位行驶距离的排污量(g/km)计算。根据《东莞市人民政府办公室关于印发<东莞市机动车排气污染防治实施方案>的通知》(东府办〔2008〕96号),东莞市已在2008年7月1日起对新车登记实行国III排放标准控制。根据国家环保部《关于国家机动车排放标准第四阶段限值实施日期的复函》(环办函[2010]1390号),从2011年7月1日起,凡不满足国Ⅳ标准要求的轻型汽油车、单一气体燃料车及两用燃料车,不得销售和注册登记。53 广东现代国际展览中心二期扩建工程环境影响报告书可以预计,在不久的未来,不满足国III、国IV排放控制标准的机动车辆,将逐步退出东莞市。根据国家经济贸易委员会、国家发展计划委员会、公安部、国家环境保护总局《关于调整汽车报废标准若干规定的通知》(国经贸资源(2000)1202号),我国境内机动车的使用寿命一般为8~15年。本项目预计2015年2月建成,届时,《东莞市机动车排气污染防治实施方案》已实施约7年,则最多有大约有50%在东莞市行驶的车辆其排放标准不能满足国III或国IV排放控制标准。剩余约50%的达标者,又以国IV排放控制标准的车辆为主,按照其实行的年限来考虑,其比例约为国III:国IV=3:3.5,即满足国III排放控制标准车辆约为23%,满足国IV排放控制标准车辆约为27%.对于不满足国III或国IV排放控制标准的车辆,其汽车尾气按照《公路建设项目环境影响评价规范》(JTGB03-2006)中有关汽车尾气排放因子进行计算。06规范、国III、国IV排放标准中的车辆单车排放因子分别见表3.3-9和表3.3-10。表3.3-906规范车辆单车排放因子推荐值(单位:mg/辆·m)平均车速(km/h)车型污染物种50.060.070.080.090.0100.0CO31.3423.6817.9014.7610.247.72小型车NOx1.772.372.963.713.853.99CO30.1826.1924.7625.4728.5534.78中型车NOx5.406.307.208.308.809.30CO5.254.484.104.014.234.77大型车NOx10.4410.4811.1014.7115.6418.38表3.3-10国III、国IV准排放因子单位:g/km.辆小型车中型车大型车污染物国III国IV国III国IV国III国IVCO1.471.1582.491.5053.092.7NOX0.330.210.420.250.90.5(2)NOX与NO2换算系数NOx浓度转化为NO2浓度参照在广东地区较新的研究成果做如下处理:在环境空气中NO2占NOx的比例视所在区域的大气化学反应条件不同可以是50%-80%。根据珠江三角洲太阳辐射较强的特征,考虑机动车废气中NO约占90%及道路两侧区域NOx迅速衰减的特征,其转换系数一般取60%。54 广东现代国际展览中心二期扩建工程环境影响报告书(3)计算公式车辆排放气态污染物源强按下式计算:3LEiijQji1243600式中:Qj-j类气态污染物排放源强度,g/s;Li-i型车车库内行驶距离,m;Eij-汽车专用公路运行工况下i型车j类排放物在预测年的单车排放因子,mg/(m·辆)。(4)大气污染物源强预测结果本报告基于一期工程停车场录入的车型构成比,即大中小型车的比例平均约为,大型车:中型车:小型车=10%:15%:75%。车库机动车停放点离出口平均按200米(双程400米),按每辆车每天进出一次,全年3365天计,车位平均利用率取70%。外博大厦三层地下车库总容积160289m,展览馆地下车33库总容积330241m,C区停车场地下车库总容积约45234m。根据以上计算模式、单车排放系,项目地下车库污染物的产生情况见表3.3-11。表3.3-11项目车库汽车尾气排放源强污染物地下泊位项目NOxNO2CO大型车(mg/s)1.7471.0481.276中型车(mg/s)1.3490.8097.569外博大厦小型车(mg/s)2.3971.43838.439969个合计(mg/s)5.4923.29547.284合计(t/a)0.1730.1041.491大型车(mg/s)4.7422.8453.466展览区中型车(mg/s)3.6632.19820.552A、B小型车(mg/s)6.5073.904104.3682631个合计(mg/s)14.9138.948128.385合计(t/a)0.4700.2824.049大型车(mg/s)1.0820.6490.790C区中型车(mg/s)0.8350.5014.687停车场小型车(mg/s)1.4840.89023.801600个合计(mg/s)3.4012.04129.278合计(t/a)0.1070.0640.923总计年排放量(t/a)0.7510.4506.46355 广东现代国际展览中心二期扩建工程环境影响报告书3、垃圾收集站臭气项目拟设置垃圾收集站,位于项目南侧靠近会展南路。垃圾堆放过程中产生发酵臭气,主要污染物为H2S和NH3,此外还有甲硫醇、甲胺、甲基硫等有机气体。4、废气排放总量项目污染源的排污状况,建设项目废气污染物排放量如表3.3-10:表3.3-10建设项目废气排放总量单位:t/a污染物SO2NOx(NO2)烟尘CO车库汽车尾气--0.751(0.450)--6.463发电机尾气0.1960.4210.088--合计0.1961.1720.0886.4633.3.2.3噪声污染源分析本项目运营期间的噪声主要包括设备噪声、进出车辆产生的噪声以及会展期间商业噪声等。(1)设备噪声运营期项目内噪声污染源有:机动车噪声、水泵、备用发电机、冷却塔和风机等机械噪声,据类比调查分析,各类声源声级值如表3.3-11:表3.3-11声源声级值声源声级范围dB(A)距离声源(m)声源数量水泵70-755地下室水泵房10风机65-755地下室风机房10机动车60-705地下车库配电房低频噪声5专用设备房6电梯机房低频噪声5专用设备房10外博大厦裙楼屋面14冷却塔6015展览馆A区屋面22外博大厦地下设备房7冷水机组80-855展览馆地下设备房8柴油发电机组100-1055展览馆地下设备房2(2)进出车辆噪声汽车进出停车场时将产生汽车噪声,汽车噪声分为汽车喇叭声、发动机辐射的噪声、进气噪声、排气噪声、冷却系统噪声、传动系统噪声、车体震动噪声等。该类噪声源强的特点为瞬时发生、持续时间较短且时段性明显:白天车辆出入较多,特别是上下班时间噪声源强较大,也有较大波动;其它时段源强较小。夜间车辆进出停车场较少,噪声源强较小。(3)会展期间商业噪声56 广东现代国际展览中心二期扩建工程环境影响报告书本项目展览区会展期间,随着区域人流的增加,会产生一定的商业噪声和社会生活噪声,噪声源强约在65dB(A)-75dB(A)。(4)低频噪声本项目设置的变配电房、电梯机房等引起的结构噪声属于低频噪声,对办公会产生一定影响。3.3.2.4固体废物污染源分析本项目运行期间产生的固体废物主要包括:办公垃圾、商业垃圾、废旧电池(属于危险废物)等。(1)办公垃圾本项目办公区域总人数约为11483人,人均办公垃圾产生量取0.5kg/人.d,则日产生办公垃圾量为5.7t/d。(2)商业垃圾商业垃圾的产生量随人口的变化的变化,产生量波动幅度较大。商业垃圾一般属于城市生活垃圾的范畴,其成份与居民生活垃圾成份相似。根据类比调查,商业垃圾按0.5kg/人.d计算,项目展厅参观人员约为20000人,则商业垃圾日产生量为10t/d。(3)废旧电池废旧电池产生量按每月1kg计算,则年产生量为12kg/a。属于危险废物,应定期收集后交由有资质的单位处理。(4)小结综上所述,本项目日产生一般生活垃圾总量约为15.7t,年产生一般生活垃圾总量约为5652t;废旧电池(危险废物)年产生量为12kg/a。3.3.2.5其它污染源(1)光污染外博大厦塔楼外墙装饰拟采用玻璃幕墙,可能会存在光污染问题。外博大厦塔楼夜晚的灯光照明可能存在光污染问题。(2)高楼风与日照影响外博大厦塔楼高度为480米,为超高层建筑;地块周边高楼较少,仅东北面有嘉华大酒店,楼高53层。本项目的建设对附近风场的影响不大,形成高楼风的可能较小。同时,本项目外博大厦超高层建筑的建设,可能对本项目及周边住宅楼的日照产生一定的影响。57 广东现代国际展览中心二期扩建工程环境影响报告书(3)对城市景观的影响本项目为超高层建筑物,有可能对所在区域的景观造成一定的影响。(4)对区域交通的影响本项目建成后将导致本区域人流的大量增加,可能会引发停车困难及交通阻塞问题。3.3.2.6运营期污染源汇总项目运营期污染源汇总详见表3.3-12。污染物SO2NOx(NO2)烟尘CO车库汽车尾气--0.751(0.450)--6.463发电机尾气0.1960.4210.088--合计0.1961.1720.0886.463表3.3-12运营期污染源汇总表外排量产生量去除量项目污染物(预处排放方式(t/a)(t/a)理)(t/a)CODcr202.1171.830.3预处理后经市政管网排BOD5101.091.99.1生活污水入厚街沙塘污水处理SS111.177.833.3水厂,最终排入东莞运河氨氮12.612.20.4污SO20.1960.1570.039通过烟井引至楼顶经水染备用发电机尾NOx0.4210.4210喷淋(添加碱液)处理后源气烟尘0.0880.0350.053由专用排气筒高空排放车库机动车尾NOx0.7510.7510排风口通至地面后无组气CO6.4636.4630织排放生活垃圾5652t/a5652t/a0日产日清固体废物废旧电池等12kg/a12kg/a0危险废物水泵70-75dB(A)10-25dB(A)风机65-75dB(A)5-25dB(A)噪机动车60-70dB(A)昼间≤0-20dB(A)水泵、风机、配电房等声配电房低频噪声60dB(A)-置于地下室内,并采取污噪声电梯机房低频噪声,夜间≤-隔声、消声、吸声及减染冷却塔60dB(A)/15m50dB(A)6-16dB(A)振等措施处理后排放源冷水机组80-85dB(A)20-35dB(A)柴油发电机组100-105dB(A)40-55dB(A)3.3.3外环境污染源分析58 广东现代国际展览中心二期扩建工程环境影响报告书3.3.3.1工业污染源本项目周边的主要工业企业类型、企业名单及主要产品、与项目的位置关系及主要污染物见表3.3-13。表3.3-13项目周边主要工业污染源分布情况序号企业类型企业名称与本项目的位置关系与项目位置主要大气污染物东莞竣城化工有丙烯酸树脂1化工东南偏东620m二甲苯限公司醇酸树脂苯、甲苯、二甲苯、2石材东成石材东南偏东670m大理石、花岗石等甲醛等广东名廷古典红3东南侧610m家具制造木家具厂木质家具、沙发等4帝豪家具北侧330m苯、甲苯、二甲苯、5银升鞋业北侧偏西320mVOCs6制鞋业颖东鞋业北侧偏西200m皮鞋、塑料鞋7瑞丰鞋业东南侧620m1、东莞竣城化工有限公司(1)醇酸树脂催化剂多元酸二甲苯溶剂多元醇醇解酯化稀释过滤成品植物油CO2气体催干剂助剂图3.3-1醇酸树脂生产工艺流程醇酸树脂的工艺流程,要经过醇解反应、酯化反应、稀释、过滤四道工序来完成。生产在反应釜中进行。生产过程中,二甲苯回流过程中,部分不凝气体散逸,散逸气体以二甲苯为主。59 广东现代国际展览中心二期扩建工程环境影响报告书(2)丙烯酸树脂图3.3-2丙烯酸树脂生产工艺流程生产丙烯酸树脂时,原辅材料易挥发产生有机废气。无组织排放点主要为分散工序,其次为研磨工序。另外,反应釜减压阀和液态物料桶口(投加、盛装过程)也存在物料少量的逸散。经对同类型厂家的类比调查分析,在原辅材料生成产品(树脂)的过程中,有机物料总损失量约为总投加量的0.7‰,主要为挥发损失,其中以二甲苯损失比例最高。60 广东现代国际展览中心二期扩建工程环境影响报告书2、东成石材噪声、扬尘、尾气有机气体废水、噪声、粉尘噪声、扬尘、尾气入厂大板切割胶补抛光磨边质检、入库出厂废水、噪声、粉尘废水、噪声、粉尘图3.3-3石材生产工艺流程在板材胶补过程中,会使用到有机粘胶。目前石材化学胶粘剂主要有不饱和树脂类(云石胶、水晶胶、强力胶、水晶云石胶)和环氧树脂类(环氧稀胶、微裂纹修补)两大体系,这两类产品有一个共同的作用就是能增加石材的机械强度表面硬度及修补板材的缺陷。不同之处在于不饱和树脂类主要应用于大理石,而环氧树脂类主要应用于花岗岩。这些胶粘材料有的无毒,但有的则会在施工中和固化后释放出一些有毒有害物质,如:苯、甲苯、二甲苯、甲醛等挥发性有机物。3、家具制造根据《家具制造行业挥发性有机化合物排放标准》(DB44/814-2010),广东省辖区内家具制造行业生产过程中主要大气污染物为苯、甲苯、二甲苯、VOCs。4、制鞋根据《制鞋行业挥发性有机化合物排放标准》(DB44/817-2010),广东省辖区内家具制造行业生产过程中主要大气污染物为苯、甲苯、二甲苯、VOCs。因此,确定周边工业企业排放的大气污染物苯、甲苯、二甲苯为特征污染因子,本报告通过现状监测来评价周边工业废气对项目选址地空气质量的影响程度。3.3.3.2周边交通污染源1、城市道路由于外博大厦高达480m,与周边建筑物高差大,周边建筑物对交通噪声的遮挡作用小,其将受到更远处城市道路交通噪声的影响,因此,本报告主要考虑200m范围内的家具大道、200m范围外的省道S256、会展南路等城市道路交通噪声影响。(1)车流量现状情况--项目周边道路现状情况见表3.2-2。规划情况--车流量根据《广东现代国际展览中心设计方案交通影响评价》成果,引用道路规划设计车流量;车型比参照现状监测结果。统计结果如下:61 广东现代国际展览中心二期扩建工程环境影响报告书表3.3-15周边道路设计车流量昼间(辆/h)夜间(辆/h)规划车流量*设计车速道路名称(pcu/h)(km/h)小型车中型车大型车小型车中型车大型车省道S25680006026733842991235200193会展南路2800501874297192982146129家具大道54005036025543861789268246注:规划车流量*引用《广东现代国际展览中心设计方案交通影响评价》成果。(2)道路相关参数表3.3-16道路相关参数道路名称道路等级红线或路幅宽度(m)现状车道数(双向)规划情况省道S256省道528拓宽到双向10车道家具大道城市主干路606/会展南路城市次干路304城市主干道,双向6车道交通噪声污染源计算车辆行驶平均辐射声级(dB(A)),采用如下公式:小型车LS=12.6+34.73lgVs中型车LM=8.8+40.48lgVm重型车LL=22.0+36.32lgVL式中:V为设计车速(km/h)省道S256设计车速为60km/h,参照东莞市其它城市主干道,城市主干道设计车速一般为50km/h,道路噪声源强为详见表3.3-17。表3.3-17周边道路噪声源强单位:dB(A)昼间平均夜间小时道路名称小车中车大车小车中车大车会展南路71.677.683.771.677.683.7家具大道71.677.683.771.677.683.7省道S25674.480.886.674.480.886.6废气污染源报告采用同类道路监测结果说明汽车尾气的影响程度,见7.8.1节。2、轨道交通本报告引用《东莞市城市快速轨道交通R2线(东莞火车站~东莞虎门站段)环境影响报告书》、《穗莞深城际轨道交通工程环境影响报告书》的成果,分析运营期受城市轨道交通的影响程度,详见报告书7.8节。62 广东现代国际展览中心二期扩建工程环境影响报告书第4章区域环境概况4.1自然环境概况4.1.1地理位置本项目建设地点位于东莞市厚街镇新塘村家具大道南侧地块。东莞市地处广东省中南部、东江下游、珠江三角洲腹地,珠江口东岸,东江下游的珠江oooo三角洲。地处东经11331′–11415′;北纬2239′-2309′。最东是清溪的银瓶嘴山,与惠州接壤;最北是中堂大坦乡,与广州市、惠州市隔江为邻;最西市沙田西大坦北的师姊洋中心航线,与广州市隔海相望;最南是凤岗雁田水库,与深圳市相连,毗邻港澳,处于广州至深圳经济走廊中间。西北距广州59公里,东南距深圳99公里,距香港140公里。东西长约70.45公里,南北宽约46.8公里,全市陆地面积2465平方公里。厚街镇位于珠江三角洲东岸、穗港经济走廊中段,毗邻广州、深圳、香港、澳门,至深圳宝安机场仅30分钟车程,1小时车程可抵达珠江三角洲各主要城市。厚街现有广深高速公路、S256省道、珠三角城际轻轨、东莞轨道交通R2线、规划中的番莞高速和环莞快速路等6大交通骨干网络纵贯全境,穗港客运高速铁路新东莞站等坐落其中。近年来通过不断完善路网建设及道路升级整治,全镇16米宽以上道路总长300多公里。随着《珠三角发展规划纲要》的实施和厚街交通格局的重构,厚街作为东莞交通枢纽中心的地位更加突出。项目在东莞市厚街镇的地理位置见附图2.1-1。4.1.2地形地貌东莞市地貌以平原丘陵为主,有山地、丘陵、冈地、平原等类型。地势是东南高,西北低。自东南向西北倾斜,由海拔800-400米逐渐降到20.01米。地质构造上,位于北东东向罗浮山断裂带南部边缘的北东向博罗大断裂南西部、东莞断凹盆地中。地势东南高、西北低。地形属平原丘陵型,以丘陵台地、冲积平原为主,丘陵台地占44.5%,冲积平原占43.3%,山地占6.25%。东南部多山,尤以东部为最,山体庞大,分割强烈,集中成片,起伏较大,海拔多在200~600米,坡度30℃左右,银瓶嘴山主峰高898.2米,是东莞市最高山峰;中南部低山丘陵成片,为丘陵台地区;东北部接近东江河滨,冈地发育,陆地和河谷平原分布63 广东现代国际展览中心二期扩建工程环境影响报告书其中,海拔30~80米之间,坡度小,地势起伏和缓,为易于积水的埔田区;西北部是东江冲积而成的三角洲平原,是地势低平、水网纵横的围田区;西南部是滨临珠江口的江河冲积平原,地势平坦而低陷,是受潮汐影响较大的沙咸田地区。综观东莞的自然环境,基本上可以分为两大自然地理区:(一)东江平原及三角洲区;(二)中部和东南山丘区。东江平原及三角洲区是东莞市主要平原地区,也是主要农业区域。由于在北回归线以南,属热带区域,故热量比广州还要丰富,对本市发展农业极为有利。该区分布于市区北部东江干流南岸和市区西部东江三角洲地区,故可细分为二个不同小区,即东江泛滥平原和东江三角洲。前者以易受洪水威胁的低洼埔田区为主,排水是首要工程,1958年开挖东莞运河以解决排涝。东江三角洲以石龙为顶点,分南北二支流:北支流经新塘、麻涌入北海河,南支流经东莞厚街入北海河,其间有一级至三级汊河发育,成东江三角洲放射状河网区。三角洲平原是水稻和香蕉生产基地。三角洲外缘地区易受咸害。沙田不断发展,有利于农业耕地的增加。三角洲沿岸更是深水港良好基地。中部和东南部山丘区是以低丘、台地为主的半山区,东南部属低山和中山(800米以上)地区,为寒溪水等暴流性山溪发源地。由于已入热带范围,故地带性土壤已划入赤红壤地区,只有山上才有红壤和黄壤分布。由于山地可截水量,云雾较大,故成为小河源头,但流量不稳定,洪水期可为患,枯水期干涸。除沿河有水稻土外,大部耕地以旱地、坡地为主,以草坡为多。山丘区基本上也可分为两个小区,即东南冈地丘陵区和中南部低丘盆地区。东南冈丘区有898米高的银瓶嘴山地,坡度达35度以上,云雾多,故山顶已有黄壤分布。热带季风雨林残迹仍可见到。中部、南部为低丘陵和切割台地地形,坑、桐田多在此区。4.1.3地层岩性项目选址区经勘探,按地层成因类型和岩土层性质,场区内地层自上而下分为:人工填土层、第四系冲积层、第四系残积土及上第三系砂岩。1、人工填土层素填土:土灰、灰色,稍湿,结构松散。由粘性土组成,局部见砂砾,为近年堆填而成。本次勘察全部钻孔揭露本层,其中,层厚0.6~5.3m,平均厚度2.41m;顶板埋深均为0.00m;顶板标高3.0~3.7m,平均标高3.61m。2、第四系冲积层64 广东现代国际展览中心二期扩建工程环境影响报告书淤泥质土:灰色,饱和,流~软塑。粘性弱,由粉粘粒和少量有机质组成。其中,层厚0.6~3.7m,平均厚度1.72m;顶板埋深0.6~4.5m,平均埋深2.13m;顶板标高-0.9~3.0m,平均标高1.47m。中砂:浅灰色,饱和,松散为主,主要成分为中砂、粗砂、少量粉粘粒、有机质。分选性较好。层厚2.5~4.0m,平均厚度3.08m;顶板埋深2.1~4.0m,平均埋深2.85m;顶板标高-0.3~1.6m,平均标高0.85m。粉质粘土:棕红夹浅黄白色,稍湿,可塑为主,局部软塑。粘性弱,由粉粘粒组成。层厚0.6~7.6m,平均厚度3.08m;顶板埋深1.7~5.4m,平均埋深3.57m;顶板标高-1.8~1.9m,平均标高0.05m。3、第四系残积土粉质粘土:棕红色,稍湿,可塑为主,局部软塑。粘性弱,由粉粘粒组成。岩芯表面平整为主。层厚0.2~6.7m,平均厚度2.92m;顶板埋深3.1~9.5m,平均埋深5.98m;顶板标高-5.9~0.6m,平均标高-2.38m。粉质粘土:棕红色,稍湿,硬塑为主,局部可塑偏硬塑。粘性弱,由粉粘粒组成。岩芯表面平整为主。层厚0.7~5m,平均厚度2.72m;顶板埋深4.5~9.6m,平均埋深6.84m;顶板标高-6~0.8m,平均标高-3.25m。4、上第三系砂岩强风化砂岩:棕红色,主要成分砂粒、粉粒。呈土状强风化为主,遇水易软化、崩解。层厚0.5~5.3m,平均厚度1.96m;顶板埋深5.4~12.2m,平均埋深9.05m;顶板标高-8.6~-1.7m,平均标高-5.42m。中风化砂岩:棕红色,风化程度为中风化岩,不等粒结构,层状构造,主要成分为砂粒,少量粉粒,岩芯较破碎-较完整,呈柱状为主,部分呈块状,质地较致密,敲击声较脆。层厚0.8~15.7m,平均厚度4.84m;顶板埋深6.5~16.5m,平均埋深10.45m;顶板标高-12.9~-2.8m,平均标高-6.85m。微风化砂岩:微风化,棕红色,不等粒结构,层状构造,主要成分为砂粒,少量粉粒,岩芯较完整为主,呈柱状为主,质地致密,敲击声脆。层厚1~15.29m,平均厚度7.2m;顶板埋深9~25m,平均埋深15.07m;顶板标高-21.5~-5.4m,平均标高-11.47m。项目地质勘探总平面布置图见附图4.1-1,剖面图(以1-1’为例)见附图4.1-2,柱状图(以ZK1为例)见附图4.1-3。65 广东现代国际展览中心二期扩建工程环境影响报告书4.1.4水文特征地表水:东莞市主要河流有东江、石马河、寒溪水。市境96%属东江流域,东江干流自西南角博罗县、惠阳市之间入境后,沿北部边境自东向西行至桥头新开河口,有发源于宝安区的北海河流入,至企石有企石河流入。至石龙分出南支流后,北干流续流至石滩,与来自增城的支流汇流,经市境石碣、高埗、中堂、麻涌的大盛注入北海河;南支流斜向西南,在峡口接纳来自市境中部的寒溪水,峡口以下有三支较小的支流牛山水、蛤地水和小沙河,自东向西汇入,流经石碣、莞城、道滘、厚街、沙田于泗盛注入北海河。北干流与南支流之间为东江三角洲的河网区。因地处东江下游、东江三角洲的河网地带,境内河流水道纵横交错,主要水系有:东深供水工程、东引运河、东江、东江干流下游河网。东莞水系水文情势主要受降雨径流、海洋潮汐以及人为作用的影响。境内降雨受季风气候的控制,每年4~9月份雨季(半年)的洪水径流占全年径流的80%以上,枯水期仅占20%,径流变化与降水过程相应。由于洪水径流过于集中,洪水水位较高,不但增加了防洪的困难,而且由于顶托作用,不利于废污水排放,造成内涝与内泻。枯水期河网水系受到潮汐控制,潮区界上移,潮流与咸潮深入河网地区,以部分补偿雨季洪水所填充的河床体积。潮流的深入,使得水体含盐度增高,影响水体的供水功能。目前,东莞水系上修建了许多水闸、取水泵站,对于东莞水系水文情势影响颇大,特别是城镇污水的大量排入,影响水环境质量。项目所在区域主要河流为东莞运河,东莞运河始于桥头镇建塘口,流经13个镇街自长安注入珠江。地下水:项目选址场地所在地透水性和富水性较弱。填土、淤泥质土、粉质粘土、砂岩透水性较差。地下水主要受大气降水及侧向渗入补给。勘察期间测得稳定水位埋深为1.3~1.75m,平均为1.54m,初见水位与稳定水位基本持平。根据本地经验,水位变化随季节性气候变化波动幅度不超1.1m。项目在地质勘探中,对地下水的部分水质进行了监测,结果如下:66 广东现代国际展览中心二期扩建工程环境影响报告书表4.1-1地下水水质分析主要指标表主要腐蚀性指标取样孔号侵蚀性COHCO3-22--pH值SO4(mg/L)Cl(mg/L)(mg/L)(mmol/L)ZK136.3217.34148.25150.541.56ZK1086.2822.40170.10172.041.77III类标准值6.5-8.5—250250—达标情况超标—达标达标—从上表可见,本项目地下水中pH值偏低,有一定的腐蚀性,硫酸盐和氯化物指标能够达标。4.1.5气象气候东莞市属亚热带季风气候,长夏无冬,日照充足,雨量充沛,温差振幅小,季风明显。多年平均气温22~23℃,终年温暖,一月份气温最低,月均气温13.5℃,极端最低气温达0.4℃(1967年1月17日),最高气温是七月份,月均气温28℃,极端最高气温达37.9℃(1963年9月5日)。日照时数充足,年平均日照时数为1978.2小时。一年中2~3月份日照最少,7月份日照最多。雨量集中在4~9月份,其中4~6月为前汛期,以锋面低槽天气降水为多。7~9月为后汛期,台风降水活跃。常受台风、暴雨、春秋干旱、寒露风及冻害的侵袭。东莞市地处北半球低纬度亚热带,珠江出海口东侧,濒临海洋,常受亚热带海洋性气候的影响,四季温暖湿润、阳光充足、雨量充沛。与同纬度内陆地区相比,冬季偏暖,夏季偏凉。降雨量:降雨量丰富,年平均降雨量达1600毫米。4月至9月为雨季,每月雨量在100-200毫米以上。多雨季节与高温季节一致,对下半年各种作物的迅速生长非常有利。气温:气候宜人,年平均气温为22~23℃。这样的气温很适合水稻、甘薯等农作物的生长,并能满足香蕉、荔枝、龙眼、木瓜、芒果等热作物的需要。日照:日照条件很好。年日照百分率达43%,全年实照时数1800小时以上。白昼长短的季节时差不大。光线充足,对于各种作物进行光合作用很有利。风:年平均风速2.0米/秒。风向的季节性明显,冬季以偏北风为主、夏季以偏南风为主。全年主导风向为东风,次主导风向为东北风。寒潮:每年寒露后至次年惊蛰前,经常有冷空气入侵,可能使喜温作物如香蕉、木瓜等受侵害。早春时期,寒潮强度稍有减弱,但仍是时有寒潮南下,引起低温阴雨,会造成早播67 广东现代国际展览中心二期扩建工程环境影响报告书秧苗烂秧。4.2社会概况概况:厚街镇位于珠江三角洲东岸,穗港经济走廊中段,北连东莞市区,南邻虎门港,东倚大岭山,西南毗连沙田,西北与道滘、洪梅等隔河相望。广深高速公路、S256省道及规划中的穗莞深城际轨道、环莞快速路、东莞市域轨道交通R2线、番莞高速等纵贯全镇,广深港客运专线新东莞站坐落其中。全镇总面积126.15平方公里,户籍人口9.7万,外来暂住人口34万。2010年完成国内生产总值198.14亿元,增长14.38%;完成工业总产值462.1亿元,增长31.97%。全镇进出口总额78.44亿美元,增长24.09%,其中出口总额50.72亿美元,增长22.34%;实际利用外资金额1.21亿美元,增长22.21%。完成税收24.55亿元,增长24.87%,其中镇本级可支配财政收入9.35亿元,增长18.28%。全社会固定资产投资37.8亿元,增长13.45%;12月末金融机构各项人民币存款余额293.8亿元;社会消费品零售总额67.8亿元,增长15.28%。农村集体经济进一步增强,全镇23个村中,15个村组两级可支配财政收入总额超3000万元,13个村组两级净资产超2亿元;农村人均收入达15393元,增长5%。2010年,厚街镇获市协调发展单项奖、市维护稳定和社会治安综合治理工作先进镇街、市2010年度食品安全工作先进单位、党管武装先进单位。推进转型升级:2010年,厚街镇深入推进产业结构调整和转型升级,明确外资、民营企业准入―门槛‖,严把用地、合同、招商、审批等7个关,内资引进实现增量增质,引进天虹商场、天铖科技、欧莱溅射材公司等优质内资项目16宗,协议投资2.5亿元。投入科技与经济发展资金1926万元,扶持企业创新发展;组织召开近10次家具业、鞋业等传统产业转型升级研讨会,引导企业自主品牌化、精益化、高端化创新发展。12家企业申报市科技研发资助,申请资金2404万元;3家外资企业成功申报内设研发机构,骅国电子获得市第三批市级企业技术中心认定;家具设计院和金河田入选市首批工业设计示范基地(企业)。2010年,全镇通过省级科技成果鉴定的科研项目9个,通过市级科技成果鉴定7个,共有2家企业获省民营科技企业。巩固和发挥机电、家具、鞋业等三大主导产业聚集优势,积极培育汽车电子产业集群,强化机电制造业品牌化发展,鞋业产业集群顺利通省产业集群升级示范区的年度考核,并被市确立为市传统产业转型升级试点行业。大力推进总部经济建设,烟草物流总部已在项目选址和合作模式上取得突破性进展。68 广东现代国际展览中心二期扩建工程环境影响报告书优化外资结构:2010年,厚街镇加快促进外资企业向新领域、新技术转型发展。推动38家重点耗能企业以及伟易达电子、绿洲鞋业、诠盛电器等12家重点排污企业加快技术和设备更新改造;推动龙记环保公司和高校科研机构联合开发新型节能环保LED路灯,并逐步推广;引导泰科电子、绿洲鞋业、三星电子等7家企业被省认定为―广东省直通车服务重点企业‖。推进外经贸5个―1000‖专项工作,推动50家加工贸易企业提升生产力水平。全年共有18家外资企业引进先进设备,7家外资企业申请内设研发机构,25家企业从OEM向ODM生产模式转变。举办来料加工企业转变形态专题讲座,促进企业发展形态由―生产车间‖向―企业总部‖的战略性转变,引导来料加工企业由―非法人企业‖向―法人企业‖转变,全年共有76家来料加工企业转变形态。发展民营经济:2010年,厚街镇积极发展民营企业,指导企业申请国家、省、市各类专项资金。南兴、金河田、兆生、金叶珠宝等企业申请市专项资金,三友联众、愉丰制衣、永益食品等企业申请新增增值税奖励计划,50多家企业取得市、镇财政科技项目资助4106万元。推动金叶、金龙、慕思、城市之窗、南兴和三友联众等6家企业获评市50强民营工业企业,励骏入选市50强民营服务业企业;金叶、金河田、远梦等3家民营企业被认定为2010-2012年东莞市工业龙头企业。组织银企融资推介会专场,拓展民营企业融资和担保渠道;中小企业和加工贸易企业累计获得融资贷款563宗计67.19亿元,其中民企获得融资贷款524宗计61亿元。先后组织民营企业家到清溪镇和韶关产业转移工业园考察,到阳西县参加商务活动,商汇集团与阳西县签订了1000亩的海田综合开发意向书,盛和伟业签订温泉项目开发意向书;组织重点民营企业参加开罗2010中国商品贸易交流会等国内外展销会或交易会,协助企业及其产品打入国内外市场。2010年,厚街镇拥有个体工商户2.77万户、私营企业4718家,民企税收12.15亿元,占全镇税收总额50%;规模以上民营经济工业产值103.9亿元,增长16.17%。发展服务业:2010年,厚街镇形成投资多元化、旗舰型商贸中心与繁华商业街点线结合的商业新格局,并逐步向专业化、高端化发展。会展业突破发展,全年共举办包括外博会在内的展会17个,展出面积80万平方米。外博会、名家具展、国际模具展、名鞋展、车博会等品牌展会被认定为东莞市重点商贸企业(项目)十大展会;成功协助办好第二届外博会,外博会宣布永久落户厚街。酒店业规范发展,积极筹办厚街酒店管理学院,推动《酒家酒店分等定级规定》的国家标准在餐饮企业日常管理中的应用;全面统筹14家获得―国家级酒家酒店‖的企业年审工作,厚街喜来登酒店获中国十佳城市商务酒店,厚街国际大酒店获评全国69 广东现代国际展览中心二期扩建工程环境影响报告书年度最佳商务酒店。商贸业优质发展,加快建设华南国际电子交易中心、兴业国际家具之都、濠畔三期、南峰二期等重点项目,祥鸿农批专业市场建成营业,成功引进天虹商场,兴业夹板市场和嘉华酒店被认定为2010-2012年东莞市商贸龙头企业。城市建设:2010年,厚街镇针对新的交通格局变化,重新定位城市发展方向,加快推进项目建设和“三旧”改造,掀起第二次城市化浪潮。实施城市总体规划。完善各项控制性详细规划的编制和送审工作,会展、东部、北部、桥头、沙溪、白濠6个片区控规通过市审批;行政体育文化区内体育馆和体育公园方案设计和扩初设计基本完成,市民中心、文化中心进入深化中标方案阶段。推进重点工程建设。2010年共有48个项目纳入镇重点项目建设,其中新动工项目9个,续建项目39个;东环路、祥鸿农批中心、沙塘污水处理厂等15项已完工,占项目总数的31%;已动工建设15项,占项目总数的31%。全年累计完成投资约10.2亿元,带动实现全镇固定资产投资37.81亿元。全面展开―三旧‖(旧城镇、旧厂房、旧村庄)改造。全镇纳入―三旧‖改造项目共86宗、涉用土地面积9679.6亩,已完成征地9宗共737.5亩。落实城市管理工作。投入近7100万元加大城市维护,投入1.26亿元加大城市基础设施建设,投入3700多万元优化环境保护,加强污染治理,推进绿化工程。加强市政设施管理,开展美化家园活动,实施社区、单位、庭院绿化美化工程,共建园林家园;优先发展公交,调整公汽现行线路、站点,优化公交线路网。狠抓环境卫生整治工作,厚街、珊美、汀山、新塘、白濠和竹溪社区6个村(社区)荣获市市容环境优美村(社区)荣誉称号。深入开展总量控制、节能减排工作,全镇每万元生产总值耗电、耗水和每亿元生产总值耗地分别下降23.8%、17.3%和4.67%,每平方公里土地产出生产总值增长4.92%,获市政府节能先进奖。社会治安:2010年,厚街镇围绕―平安亚运,平安厚街‖目标,全面推进社会治安重点整治年,构建大综治格局。一是强化责任。落实镇、村及各单位―一把手‖综治维稳责任,明确镇分管领导主要责任和村治保主任直接责任,实行捆绑式层层责任制。二是强化防治。完善社会治安监控系统,完成三期视频监控工程建设,设置监控点140个。推进派出所电脑报警二级平台建设,打造全镇视频监控联网平台。强化重点地区整治,落实每月开展不少于2次检查行动的工作制度,全年共开展大规模清查整治行动32次,出动警力3万多人次,强力切块整治20个治安重点地区和30个治安问题突出部位,有效改善社会治安环境。深入推进―治摩‖工作,组织开展大规模―治摩‖整治行动25次,共查扣各类非法车辆9797辆,被评为全市―治摩‖工作―三无三巩固‖达标镇。三是强化打击。召开厚街镇社会治安动员暨武装巡游大会,全力开展粤安10、雷霆10、创平安迎亚运、平安亚运十大行动等一系列专项行动,保70 广东现代国际展览中心二期扩建工程环境影响报告书持严打高压态势。全镇共立刑事案件2382宗,破1083宗,破案率为40.9%,破案率同比上升9.8个百分点。四是强化调处。成立镇综治信访维稳中心,大力推进一个中心服务群众、一个平台整合资源、一个流程调解到底、一个机制监督落实的运行机制。2010年,综治信访维稳中心共受理案件581宗,办结551宗,办结率为94.8%。实行诉调对接,率先与市第二人民法院建立司法协作体系,构建常态化、制度化的司法协作体系。安全生产:2010年,厚街镇被确定为省创新社会消防管理试点先行镇和市综合应急救援队伍建设试点镇。借此契机,厚街镇全力推进防火墙工程。在全市率先实施政府领导包片挂点制度,建立消防安全重点单位管理系统,将各村辖区内的―三小‖场所、出租屋、工厂企业消防监管工作落实到人。组建12支专业应急救援队和23支村级应急救援队,实施社会消防工作网格式管理。投资280万元建成全国首个镇级消防教育培训基地,首创参观、体验、学习、教育一站式消防教育培训模式。着力夯实消防基础设施,投入230多万元,增置生命探测仪、等离子切割器等64种救援器材装备;建立指挥调度中心,并引入最新的DS应急救援平台。与此同时,深入开展―安全生产年‖活动,加强对危险性较大工程和危险源的监督管理。全年共检查公共娱乐场所、高层和地下建筑、车站、学校等重点场所342间,发现消防安全隐患385处,当场整改362处。检查各村(社区)―三小‖场所、出租屋950间次,整改火灾隐患1200多处,查封2间。全年未出现重大安全事故,被评为2010年度安全生产先进镇街。民生工程:2010年,厚街镇扎实推进民富民乐工程。一是抓好就业培训工作。落实―创业东莞‖工程、劳动权益保障、新莞人就业服务3大工作。开办全额资助性技能培训班10期,参训户籍人口355人;实行社区公共就业岗位属地安置,有效安置户籍失业人员到企业村民车间、农贸市场、环卫绿化等就业岗位;设立村民车间15个,安置就业600多人;全镇各级公共就业服务机构开展推荐就业服务580人次,实现成功就业174人。二是发展医疗卫生事业。加强社区医疗卫生建设,新增社区卫生服务站2间,改建社区卫生服务站3间,基本实现社区卫生服务全覆盖。完善医疗保障制度,提高医保待遇,对参加社会基本医疗保险满3年以上的年内最高支付限额从10万元提高到15万元,社区门诊基本医疗费用统筹基金支付比例由60%提高到70%。三是抓好文化教育事业。累计投入1.1亿元,改善教育和科研基地环境,完善教育教学设备,调整教育资源配置,提升厚街教育品牌;加快推进厚街职业技术学校新校区、广东创新职业学院建设和厚街中学扩建工程,积极申报酒店职业学院;大力扶持民办教育,新增民办学校3所。积极开展以广场文化、镇村文化为主的群众性文体活动60多项次;方氏宗祠、郡附公祠通过省文物维修验收专家组现场验收。四是抓好社会保障工71 广东现代国际展览中心二期扩建工程环境影响报告书作。全镇农(居)民退休人员的人均养老金从每月231元提高到每月331元。完善民政救助机制,全年用于社会救助、救济及社会福利各项主要支出共2198万元。积极解决困难群众子女读书难问题,向677名低保家庭在读子女发放助学金171.9万元;对全镇现有的50名五保户均实行市、镇统筹供养;投入216.9万元解决困难家庭住房问题,为41户困难边缘户进行危房改造。五是办好民生实事。投入1600万元改造自来水旧管网,新建、改造西元路、永泰路等21项管网工程。加强―菜篮子‖工程建设,推动12个A级农贸市场创建样板市场,引导汀山、珊美、涌口辖区的4个农贸市场按照市食品安全样板市场的标准进行升级改造。加强新莞人服务工作,积极开展新莞人金融服务卡推广试点工作和积分制入户工作,全镇受理积分制入户申请460人,累计接受咨询并意向申请340人。集体经济:2010年,厚街镇按照―重招商、细管理、减支出、保增长‖的总体要求,加大集体经济管理力度,增强经济发展活力。加强村组资产财务管理,完善新增借款管理、土地基金管理、股份分红款管理等制度,制定关于防止村组突击增加股东预分红款、进一步加强农村集体资产转让管理等办法。着力压减村组非生产性开支,加强债务管理,加大应收款追收力度,促进农村集体经济健康稳定发展。2010年,共有三屯村等5个村获市经济单项前50名村(社区)奖,赤岭等15个村获市村组可支配常规性收入总额超3000万奖,溪头村等6个村获村级两委会工作量化评比结果综合总分前50名奖,三屯村等13个村获市村组两级净资产超2亿元奖。实行村组工作人员和治安队员定编管理。率先探索建立政务服务中心,实行公共管理职能分离;22个村已撤销村委会,挂牌成为了社区居委会,陈屋、汀山等村合并组级经济、统筹村级核算工作顺利推进。72 广东现代国际展览中心二期扩建工程环境影响报告书第5章环境质量现状调查与评价5.1水环境质量现状监测与评价水环境现状调查的目的是通过对建设项目所在地附近地表水体的监测,分析项目所在区域水环境质量状况,确定该区域水环境背景值,对项目纳污水体水质现状给予评价,为评价项目外排废水对纳污水体的影响的后续环评工作提供资料。项目所排污水经预处理后由市政污水管网进入东莞市厚街沙塘污水处理厂,处理达标后排入东莞运河,为了解东莞运河的水质现状,本评价委托东莞市环境保护监测站对东莞运河水质进行了实地监测。5.1.1水环境质量现状调查1、监测断面的布设根据《环境影响评价技术(HJ/T2.3-93)》的要求,在本次水环境评价范围内共布设3个水质监测断面,详见附图5.1-1,它们分别是:1#:厚街沙塘污水处理厂排污口处2#:厚街沙塘污水处理厂出水纳污河流——东莞运河下游1000米处断面3#:厚街沙塘污水处理厂排污口东莞运河上游400米与支流A交汇处断面2、监测项目监测项目包括pH、DO、CODCr、BOD5、SS、氨氮、总磷、总氮、LAS。3、分析方法水样的采集与分析按照国家环保局发布的《地表水和污水监测技术规划》(HJ/T91-2002)及《水和废水监测分析方法》(第四版)中的有关规定。4、采样时间与频次2012.6.11~2012.6.12日,连续监测2天,每天监测1次。水样的采集和运输均按国家环境保护总局有关质量保证的规定进行,水样的保存时间及所加入保存剂的纯度符合相关规定,确保水样有足够的代表性和准确性。73 广东现代国际展览中心二期扩建工程环境影响报告书5.1.2水质现状评价5.1.2.1评价方法地表水环境质量现状评价,采用单项标准指数法,其数学模式如下:Sij=Cij/C0式中:Sij—单项水质参数i在第j点的标准指数;Cij—第i种污染物监测结果,mg/L;C0—第i种污染物评价标准,mg/L。pH的标准指数计算式:7.0pHjSpH,j=pHj≤7.07.0pHsdpH7.0jSpH,j=pHj>7.0pH7.0su式中:SPH,j—pH在第j点的标准指数;pHj—j点的pH值;pHsd—地表水水质标准中规定的pH值下限;pHsu—地表水水质标准中规定的pH值上限。DO计算公式:DODOfDODOISDODODOfSDOIDO109DODOSDOSDO468/(31.6T)f当水质参数的标准指数大于1时,表明该水质参数超过了规定的水质标准,水体已经被该水质参数所表征的污染物所污染。5.1.2.2评价标准地表水环境质量执行《地表水环境质量标准》中III类标准,各项评价标准详见表5.1-1。74 广东现代国际展览中心二期扩建工程环境影响报告书表5.1-1地表水环境质量标准(单位:mg/L,pH除外)指标(GB3838-2002)III类标准pH值(无量纲)6~9溶解氧≥5化学需氧量≤20五日生化需氧量≤4氨氮≤1.0总磷(以P计)≤0.2总氮≤1.0石油类≤0.05阴离子表面活性剂≤0.25.1.2.3监测结果分析及评价根据监测结果,采用单项标准指数法进行计算,水质参数评价结果见下表。表5.1-2水环境质量评价结果(1#)(单位:mg/L,pH除外)最大标准监测项目监测日期监测结果超标率(%)超标倍数评价标准指数2012.6.117.09pH000.16~92012.6.127.212012.6.116.5溶解氧000.54≥52012.6.126.32012.6.1124.1化学需氧量1000.21-0.241.24≤202012.6.1224.82012.6.114.1五日生化需氧量500-0.0251.025≤42012.6.123.92012.6.119.4氨氮1008.32-8.49.4≤1.02012.6.129.32总磷2012.6.110.16000.8≤0.2(以P计)2012.6.120.142012.6.1110.93总氮1009.8-9.9310.93≤1.02012.6.1210.802012.6.11<0.05阴离子表面活性剂000≤0.22012.6.12<0.0575 广东现代国际展览中心二期扩建工程环境影响报告书表5.1-3水环境质量评价结果(2#)(单位:mg/L,pH除外)最大标准监测项目监测日期监测结果超标率(%)超标倍数评价标准指数2012.6.117.25pH000.1256~92012.6.127.232012.6.112.9溶解氧1000.465.14≥52012.6.122.72012.6.1134.2化学需氧量1000.71-0.731.73≤202012.6.1234.62012.6.117.9五日生化需氧量1000.85-0.9751.98≤42012.6.127.42012.6.119.58氨氮1008.50-8.589.58≤1.02012.6.129.50总磷2012.6.110.361000.81.8≤0.2(以P计)2012.6.120.362012.6.1111.24总氮10010.12-10.2411.24≤1.02012.6.1211.122012.6.110.28阴离子表面活性剂1000.41.4≤0.22012.6.120.27表5.1-4水环境质量评价结果(3#)(单位:mg/L,pH除外)最大标准监测项目监测日期监测结果超标率(%)超标倍数评价标准指数2012.6.117.20pH000.1156~92012.6.127.232012.6.113.0溶解氧1000.44.6≥52012.6.123.22012.6.1112.6化学需氧量000.63≤202012.6.1212.32012.6.117.6五日生化需氧量1000.825-0.91.9≤42012.6.127.32012.6.118.66氨氮1007.58-7.668.66≤1.02012.6.128.58总磷2012.6.110.311000.5-0.551.55≤0.2(以P计)2012.6.120.302012.6.1110.32总氮1009.11-9.3210.32≤1.02012.6.1210.112012.6.110.20阴离子表面活性剂001≤0.22012.6.120.20结果分析:各监测点位均超标的项目有BOD5、氨氮、总氮,此外,厚街沙塘污水处理厂排污口处(1#)COD超标,水质相对较好;厚街沙塘污水处理厂出水纳污河流——东莞运河下游100076 广东现代国际展览中心二期扩建工程环境影响报告书米处断面(2#)DO、COD、总磷、阴离子表面活性剂等项目均超出《地表水环境质量标准》的III类标准,水质较差;厚街沙塘污水处理厂排污口上游400米东莞运河与支流A交汇处断面(3#)DO、总磷超出《地表水环境质量标准》的III类标准。从超标倍数看,三个监测断面氨氮、总氮超标倍数在7.5-10.2之间,说明东莞运河在沙塘污水处理厂排污口上游400米至下游1000米范围内有机污染严重,水质较差。5.2环境空气质量现状监测与评价5.2.1环境空气质量现状调查0、监测布点根据拟建项目附近的环境情况、项目大气污染物特征和按当地主导风向、次主导风向等情况,设置3个监测点,采样监测点详见附图5.2-1,具体布点为:G1:项目东面850m的南五村;G2:项目所在场址;G3:项目西面偏北1800m的双岗村。2、监测项目G1、G3:监测SO2、NO2、PM10G2:监测SO2、NO2、PM10、苯、甲苯、二甲苯。同步监测气象条件:风向、风速、气温,大气压强,相对湿度(%)。3、分析方法监测及分析方法均按照国家环保局《环境监测技术规范》和《环境空气质量标准(GB3095-2012)》要求的方法进行。4、采样时间与频次无雨日连续监测七天。SO2、NO2、苯、二甲苯、甲苯每天在2:00,8:00,14:00,20:00分别采样监测,测定小时浓度;PM10测定日均浓度。5.2.2环境空气质量现状评价5.2.2.1评价方法评价方法为污染物单项标准指数法,计算公式为:77 广东现代国际展览中心二期扩建工程环境影响报告书CiCPi=oi式中:Pi-标准指数或比标指数;3Ci-某污染物的测值或统计值,mg/m;3Cio-相应污染物、相应的空气环境标准值,mg/m。5.2.2.2评价标准大气常规污染物SO2、NO2和PM10执行《环境空气质量标准》(GB3095—2012)中的二级标准,苯、二甲苯参照《工业企业设计卫生标准》中居住区大气中有害物质的最高容许浓度,甲苯参照―前苏联(1974)居住区大气中有害物最大允许浓度‖的规定。标准值详见5.2-2。表5.2-2大气环境质量现状评价标准污染物名称取值时间评价标准3二氧化氮小时平均0.200mg/m3二氧化硫小时平均0.500mg/m3PM10日平均0.150mg/m3苯2.4mg/m一次最高容许浓度3二甲苯0.30mg/m3甲苯日平均0.6mg/m5.2.2.3监测结果分析与评价监测时段内气象条件见表5.2-3。表5.2-3气象参数表气象参数监测点监测时间气温℃湿度%气压KPa风向风速m/s02:00-03:0028.774.199.9东南1.608:00-09:0031.269.999.9东南1.82012.6.1114:00-15:0032.265.999.8东南1.520:00-21:0029.374.399.5东南1.902:00-03:0026.770.4100.1东南1.808:00-09:0027.967.2100.1东南1.52012.6.1214:00-15:0032.565.2100.1东南1.620:00-21:0029.570.9100.1东南2.0G1南五村02:00-03:0027.374.1100.2南1.508:00-09:0028.465.6100.2南1.72012.6.1314:00-15:0032.564.2100.2南1.620:00-21:0029.376.7100.5南1.402:00-03:0026.774.7100.2南1.708:00-09:0028.963.9100.1南1.82012.6.1414:00-15:0034.261.5100.1南1.620:00-21:0028.173.1100.0南2.02012.6.1502:00-03:0028.774.199.9东南1.678 广东现代国际展览中心二期扩建工程环境影响报告书气象参数监测点监测时间气温℃湿度%气压KPa风向风速m/s08:00-09:0031.269.999.9东南1.814:00-15:0032.265.999.8东南1.520:00-21:0029.374.399.5东南1.902:00-03:0028.471.5100.2东南1.608:00-09:0029.168.8100.5东南1.02012.6.1614:00-15:0032.466.8100.4东南1.220:00-21:0029.870.1100.4东南1.102:00-03:0027.673.5100.4东南1.408:00-09:0028.367.5100.4东南1.22012.6.1714:00-15:0032.762.4100.4东南1.620:00-21:0029.672.4100.4东南1.802:00-03:0026.765.2100.2东南1.208:00-09:0028.961.5100.4东南0.962012.6.1114:00-15:0032.560.8100.2东南1.420:00-21:0029.179.3100.4东南1.002:00-03:0026.164.1100.4东南1.208:00-09:0028.468.5100.5东南0.92012.6.1214:00-15:0032.461.6100.4东南1.320:00-21:0029.870.5100.4东南1.602:00-03:0026.772.5100.4东南1.808:00-09:0028.363.6100.6东南1.22012.6.1314:00-15:0032.762.3100.6东南1.020:00-21:0029.677.1100.6东南1.102:00-03:0028.570.2100.4南2.308:00-09:0029.168.4100.4南1.0G2项目地2012.6.1414:00-15:0034.265.6100.6南1.220:00-21:0030.169.3100.6南2.002:00-03:0028.174.199.9东南1.608:00-09:0031.269.999.9东南1.82012.6.1514:00-15:0032.265.999.8东南1.520:00-21:0029.374.399.5东南1.902:00-03:0026.770.4100.1东南1.808:00-09:0027.967.2100.1东南1.52012.6.1614:00-15:0032.565.2100.1东南1.620:00-21:0029.520.9100.1东南2.002:00-03:0027.374.1100.2南1.508:00-09:0028.465.6100.2南1.72012.6.1714:00-15:0032.564.2100.2南1.620:00-21:0029.376.7100.3南1.4G3双岗村2012.6.1102:00-03:0027.575.2100.2东南1.479 广东现代国际展览中心二期扩建工程环境影响报告书气象参数监测点监测时间气温℃湿度%气压KPa风向风速m/s08:00-09:0028.369.2100.4东南1.214:00-15:0033.161.5100.4东南1.420:00-21:0029.279.3100.4东南1.602:00-03:0028.471.5100.2东南1.608:00-09:0029.168.8100.5东南1.02012.6.1214:00-15:0032.966.8100.4东南1.220:00-21:0029.870.1100.4东南1.102:00-03:0027.673.5100.4东南1.408:00-09:0028.367.5100.4东南1.22012.6.1314:00-15:0032.762.4100.4东南1.620:00-21:0029.672.4100.4东南1.802:00-03:0027.670.6100.5东南1.308:00-09:0029.163.5100.6东南1.02012.6.1414:00-15:0032.660.0100.4东南1.820:00-21:0028.472.4100.5东南2.002:00-03:0026.765.2100.0东南1.208:00-09:0028.961.5100.0东南0.92012.6.1514:00-15:0032.560.8100.0东南1.420:00-21:0029.179.3100.0东南1.002:00-03:0026.164.1100.4东南1.208:00-09:0028.468.5100.5东南0.92012.6.1614:00-15:0032.461.6100.4东南1.320:00-21:0029.870.5100.4东南1.602:00-03:0026.772.5100.4东南1.808:00-09:0028.363.6100.6东南1.22012.6.1714:00-15:0032.762.3100.6东南1.020:00-21:0029.677.1100.6东南1.1环境空气污染物监测结果见表5.2-4。80 广东现代国际展览中心二期扩建工程环境影响报告书表5.2-4环境空气污染物监测结果统计项目指标G1(南五村)G2(项目地)G3(双岗村)3浓度范围(mg/m)0.035~0.0760.069~0.1080.065~0.106超标率(%)000SO2最大值占标率(%)15.221.621.2最大超标倍数0003浓度范围(mg/m)0.033~0.1310.070~0.1180.071~0.116超标率(%)000NO2最大值占标率(%)65.55958最大超标倍数0003浓度范围(mg/m)0.054~0.0850.041~0.0840.070~0.124超标率(%)000PM10最大值占标率(%)56.75682.7最大超标倍数0003浓度范围(mg/m)<0.005超标率(%)0苯最大值占标率(%)/最大超标倍数03浓度范围(mg/m)0.02~0.06超标率(%)0甲苯最大值占标率(%)10%最大超标倍数03浓度范围(mg/m)<0.02二甲超标率(%)0苯最大值占标率(%)/最大超标倍数081 广东现代国际展览中心二期扩建工程环境影响报告书表5.2-5环境空气污染物标准指数标准指数污染物监测点监测日序2:008:0014:0020:002012.6.110.0410.0550.0520.0392012.6.120.0430.0510.0540.0462012.6.130.0350.0730.0760.043SO22012.6.140.0360.0440.0510.0442012.6.150.0350.0490.0420.0362012.6.160.0410.0480.0560.0512012.6.170.0490.0520.0710.052012.6.110.1750.4250.460.232012.6.120.360.4750.5550.412012.6.130.210.620.6550.325NO2G1(南五村)2012.6.140.1450.420.4750.362012.6.150.2650.420.370.1652012.6.160.2450.330.470.4252012.6.170.360.4150.510.3752012.6.110.362012.6.120.392012.6.130.41PM102012.6.140.572012.6.150.482012.6.160.432012.6.170.462012.6.110.1440.1680.190.1462012.6.120.1440.1640.2060.2162012.6.130.1580.1740.1840.168SO22012.6.140.1520.180.2040.192012.6.150.1380.170.1980.1682012.6.160.150.180.1780.1622012.6.170.1440.190.2160.1762012.6.110.350.460.590.4352012.6.120.4750.530.550.555G2(项目地)2012.6.130.510.5350.580.46NO22012.6.140.530.540.540.4952012.6.150.5150.530.540.42012.6.160.5050.570.590.4752012.6.170.4850.560.5450.4552012.6.110.332012.6.120.27PM102012.6.130.382012.6.140.5682 广东现代国际展览中心二期扩建工程环境影响报告书标准指数污染物监测点监测日序2:008:0014:0020:002012.6.150.392012.6.160.482012.6.170.422012.6.11~苯/2012.6.172012.6.11~甲苯/2012.6.172012.6.11~二甲苯/2012.6.172012.6.110.1380.1640.1680.142012.6.120.1440.1780.1860.132012.6.130.1460.1780.190.182SO22012.6.140.1440.2120.2020.1682012.6.150.150.1840.210.1742012.6.160.1520.180.1880.1462012.6.170.1520.1780.2040.1542012.6.110.3550.490.5450.4752012.6.120.3550.4950.5150.5152012.6.130.540.540.510.49NO2G3(双岗村)2012.6.140.5150.540.5650.542012.6.150.410.4550.540.4952012.6.160.4350.5150.5450.492012.6.170.4050.5250.580.412012.6.110.472012.6.120.762012.6.130.56PM102012.6.140.832012.6.150.632012.6.160.622012.6.170.72从表5.2-4和表5.2-5中可以看出,在监测时段内,SO2、NO2、PM10浓度达到《环境空气质量标准》(GB3095—2012)中的二级标准要求,项目区苯、二甲苯浓度能满足《工业企业设计卫生标准》中居住区大气中有害物质的最高容许浓度,甲苯浓度能满足“前苏联(1974)居住区大气中有害物最大允许浓度”;可见,本建设项目所在地周围的环境空气质量能够达到相应的功能区要求。83 广东现代国际展览中心二期扩建工程环境影响报告书5.3声环境质量现状监测与评价5.3.1声环境质量现状调查1、监测布点在本项目场址四周边界和地块内进行,监测点共布设5个,记为N1、N2、N3、N4、N5。具体位置见附图5.2-1。2、监测项目20分钟Leq(A)、Leq10、Leq50、Leq90。测定N1点的同时,同步记录家具大道的小时车流量,分大、中、小型车进行记录;测定N3点的同时,同步记录会展南路的小时车流量,分大、中、小型车进行记录;测定N4点的同时,同步记录省道S256的小时车流量,分大、中、小型车进行记录。3、分析方法按照《声环境质量标准》(GB3096-2008)、《环境监测技术规范》进行。4、采样时间与频次2012年6月11日、12日连续监测两天,昼间(6:00~22:00)和夜间(22:00~6:00)各监测1次。按照《声环境质量标准》(GB3096-2008)中的有关规定,选在无雨、风速小于5.5m/s的天气进行测量,传声器设置项目边界外1米处,高度为1.2~1.5米。5.3.2声环境质量现状评价5.3.2.1评价标准项目所在区域声环境质量执行《声环境质量标准》(GB3096-2008)中的2类声环境功能区环境噪声限值,N1(临近家具大道一侧)、N3(临近会展南路一侧)执行《声环境质量标准》(GB3096-2008)中的4a类声环境功能区环境噪声限值84 广东现代国际展览中心二期扩建工程环境影响报告书5.3.2.2监测结果分析与评价1、车流量表5.3-1监测时段车流量统计昼间(辆/h)夜间(辆/h)道路名称监测时段小型车中型车大型车小型车中型车大型车省道S2562012.6.111728264201809139141(N4)2012.6.121892256204864132120会展南路2012.6.1156280602924539(N3)2012.6.1253193522814036家具大道2012.6.1111231711306019082(N1)2012.6.12121918912156284782、各监测点监测结果分析表5.3-2各监测点位监测结果单位:dB(A)达标情监测点位监测时间监测时段Leq(A)L10L50L90标准值况/超标量昼间68.372.968.760.3702012.6.11N1(地块北面)夜间54.263.157.851.255达标临近家具大道昼间68.871.268.960.8702012.6.12夜间54.162.958.750.955昼间61.262.454.649.2601.22012.6.11夜间52.553.944.838.9502.5N2(地块西面)昼间61.363.353.249.1601.32012.6.12夜间52.152.644.739.9502.1昼间62.765.463.255.4702012.6.11N3(地块南面)夜间53.454.254.146.655达标临近会展南路昼间62.464.363.255.8702012.6.12夜间53.655.453.245.455昼间69.573.469.361.2609.52012.6.11N4(地块东面)夜间54.856.944.838.9504.8临近省道S256昼间68.972.966.760.9608.92012.6.12夜间54.763.259.451.3504.7昼间64.371.768.253.5604.32012.6.11N5夜间53.460.158.643.2503.4(项目地)昼间62.170.868.553.2602.12012.6.12夜间52.961.558.743.6502.9可见,项目地块北面、南面边界能满足《声环境质量标准》(GB3096-2008)中4a类标准,其余各监测点均超出《声环境质量标准》(GB3096-2008)中2类标准,其中地块西面85 广东现代国际展览中心二期扩建工程环境影响报告书边界昼间超标1.2~1.3dB(A)、夜间超标2.1~2.5dB(A),东面边界昼间超标8.9~9.5dB(A)、夜间超标4.7~4.8dB(A)。项目地块内昼间超标2.1~4.3dB(A)、夜间超标2.9~3.4dB(A)。项目地块周边较为开阔,东面省道S256部分道路封闭进行地铁R2线及穗莞深城际轨道施工,施工噪声和道路交通噪声对周边声环境影响较大。随着施工的结束、城市道路的畅通,区域声环境将得到改善。86 广东现代国际展览中心二期扩建工程环境影响报告书第6章施工期间环境影响分析及污染防治措施一般情况下,房地产开发建设在施工过程中产生的污染主要包括:施工废水和施工人员生活污水等废水污染,施工机械和运输车辆运行产生的噪声污染,施工扬尘和施工机械废气等废气污染,余泥渣土、建筑垃圾和施工人员生活垃圾等固体废物,这些都会给周围环境带来不良的影响;另外,项目施工期间扰动地表和破坏植被,造成地表裸露,引发水土流失,对生态产生不良影响。因此,建设单位及施工单位必须高度重视施工期带来的不利环境影响,切实做好防护措施,使其对环境的影响减至最低限度。6.1声环境影响与污染防治措施6.1.1声环境影响预测与分析施工噪声源分析施工期噪声污染源主要来自建筑施工机械噪声。建筑施工可分为:土石方阶段,基础工程阶段,主体工程结构阶段和装修阶段。根据项目工程量,类比房地产开发时的设备数量,本项目拟选用设备数量见表6.1-1。87 广东现代国际展览中心二期扩建工程环境影响报告书表6.1-1项目施工选用设备数量施工阶段设备名称设备数量翻斗车6台推土机2台土石方阶段挖掘机2台装载机2台汽车起重机6台混凝土搅拌车2台基础和结构阶段振捣棒4个电锯4个柴油发电机2台切割锯12台砂轮锯12台磨石机8台装修阶段卷扬机10台电刨15台外用电梯2台根据表6.1-1,建议项目选择低噪声机械设备,并选用静压打桩机。施工噪声标准城市建筑施工期间施工场地产生的噪声应依照《建筑施工场界环境噪声排放标准》(GB12523-2011)中有关规定执行,不同施工阶段作业噪声限值列于表6.1-2。表6.1-2建筑施工场界环境噪声排放标准(单位:dB(A))昼间夜间7055施工场界及敏感点噪声预测无指向性点声源几何发散衰减的基本公式为:L(r)=L(r0)-20lg(r/r0)(6.1-1)式中:L(r)、L(r0)分别为r、r0处的声压级如果已知r0处的A声级,则:LA(r)=LA(r0)-20lg(r/r0)(6.1-2)式(6.1-1)和式(6.1-2)等效如果已知点声源的A声功率级LWA,且声源处于半自由空间,则LA(r)=LWA-20lgr-8(6.1-3)式(6.1-3)与式(6.1-1)等效建筑施工机械作业时,可视为处于半自由空间的点声源,故适用式(6.1-3)。88 广东现代国际展览中心二期扩建工程环境影响报告书本项目占地面积较大,噪声设备分散,大多为不连续性噪声,施工场地内设备位置会不断变化,不能对施工噪声源作出精确细致的定位;本评价选择多台设备同时运行的情况进行预测,根据预测模式,得到各施工阶段不同距离的预测结果及对敏感点的预测见表6.1-3。表6.1-3各施工阶段的噪声预测结果(dB(A))距声源距离r(m)标准值施工阶段(源强)10203040608090100200300600昼夜土石方86.279.275.773.271.767.266.166.259.255.749.7基础和结构88.382.378.876.174.870.369.268.362.358.852.97055装修86.978.975.472.971.466.965.864.958.955.449.4预测结果分析根据表6.1-3中噪声的预测结果,在主要施工机械同时运行且未采取任何降噪措施的情况下白天施工,土石方阶段约在70m以上距离可以达到《建筑施工场界环境噪声排放标准》,基础施工阶段若使用静压打桩机在80m以上距离可以达标,结构阶段在80m以上距离可以达标,装修阶段约在70m以上距离可以达标;结构阶段在夜间300m处仍不能达标,打桩只在昼间施工,夜间可以达标,土石方、装修阶段夜间在300m以上距离才能达标。项目周边距离最近的敏感点距离约120m,项目施工阶段排放的噪声到敏感点约为64~67dB(A),会对敏感点声环境造成不利影响;因此,项目施工期必须采取声环境治理措施,防治施工噪声对场界外声环境的影响。6.1.2噪声污染防治措施施工期间的噪声污染主要来自于施工机械作业产生的噪声和运输车辆产生的交通噪声,应该分别采取相应的控制措施,严格遵照《东莞市控制建筑施工噪声污染管理办法》对施工噪声管理的时限规定,防止噪声影响周围环境和人们的正常生产生活。(1)合理安排施工计划和施工机械设备组合以及施工时间,施工单位夜间施工应当确定合理的作业时间,连续运输、浇灌混凝土的夜间作业,一般一次不得超过2个昼夜,装卸其他建筑材料、土石方和建筑废料不得超过当日24点。施工机械的作业时间严格限制在6时至12时,14时至22时,原则上禁止夜间施工,严禁高噪声设备在休息时间(中午或夜间)作业。如施工期因工艺要求必须连夜作业时应得到有关部门批准,并公告附近居民;否则,不得违反“任何单位和个人不得在午间(北京时间12时到14时)和夜间(北京时间22时至翌日6时)在居民区、文教区、疗养区从事打桩、洗石、搅拌等影响居民休息的强噪声建筑施工89 广东现代国际展览中心二期扩建工程环境影响报告书作业”的规定。在施工过程中,尽量减少运行动力机械设备的数量,尽可能使动力机械设备均匀地使用。(2)对本项目的施工进行合理布局,尽量使高噪声的机械设备远离敏感点。(3)应严格执行《东莞市控制建筑施工噪声污染管理办法》,进行文明施工,建立健全现场噪声管理责任制,加强对施工人员的素质培养,尽量减少人为的大声喧哗,增强全体施工人员防噪声扰民的意识。(4)施工单位应该加强与附近单位和居民的沟通,施工时,应在建筑施工工地显著处悬挂建筑施工工地环保牌,注明工地环保负责人及工地现场电话号码,以便公众监督及沟通。(5)从控制声源和噪声传播以及加强管理等几个不同角度对施工噪声进行控制:控制声源:有意识地选择低噪声的机械设备,对位置相对固定的机械设备,能于棚内操作的尽量进入操作间,不能入棚的可在施工现场的周围设置围挡阻挡噪声的传播,同时避免在同一时间集中使用大量的动力机械设备;对于开挖和运输土石方的机械设备(挖土机、推土机等)以及翻斗车,可以通过排气消声器和隔离发动机震动部分的方法来降低噪声,其他产生噪声的部分还可以采用部分封闭或者完全封闭的办法,尽量减少振动面的振幅;闲置的机械设备等应该予以关闭;一切动力机械设备都应该经常检修,特别是那些会因为部件松动而产生噪声的机械,以及那些降噪部件容易损坏而导致强噪声产生的机械设备。控制噪声传播:将各种噪声比较大的机械设备布置在远离附近环境敏感点的位置,并进行一定的隔离和防护消声处理,并在施工场地周围建立临时性围挡,这样可以减少对周边敏感点的影响。加强管理:对施工车辆造成的噪声影响要加强管理,运输车辆尽量采用较低声级的喇叭,并在所经过的道路禁止鸣笛,以免影响沿途居民的正常生活。(6)选择适当施工工艺本项目施工建议采用预应力混凝土管桩,预应力混凝土管桩由完全具有资质的工厂生产,桩身质量可以有效的得到保证。由于管桩强度高,耐打性好,可以进入强风化岩一定深度,因而比较适合作用摩擦端承桩或端承摩擦桩,再则是工期短,造价低。结构施工是进行现场混凝土浇筑或采用各种类型的起重机械将预制的结构件安装到设计位置的施工过程。外博大厦为10层以上的高层装配式结构,需采用爬升式或附着式自生塔式起重机。建议项目施工选择上述施工工艺,尽可能将施工噪声对周边环境的影响降至最低。90 广东现代国际展览中心二期扩建工程环境影响报告书6.2环境空气影响与污染防治措施6.2.1施工扬尘环境影响分析本项目施工扬尘主要来自于以下几个方面:(1)场地平整和地基处理中,将使用挖土机和推土机进行堆填,在砌块堆砌,沙土搬运、倾倒过程中将有少量土壤从地面、施工机械、土堆中飞扬进入空气;(2)原料堆场和暴露松散土壤的工作面,工作面表面多数为细小沙土,受风吹时,表面侵蚀随风飞扬进入空气;(3)物料运输过程中车辆在裸露地表上行驶时带起的扬尘,以及车上装载的物料碎屑飞扬进入空气。施工扬尘的产生与影响是有时间性的,它随着施工的结束而自行消失。据有关调查显示,施工工地的扬尘主要是由运输车辆行驶产生,与道路路面及车辆行驶速度有关,约占扬尘总量的60%。在完全干燥情况下,可按经验公式计算:0.850.75vWPQ0.12356.80.5式中:Q—汽车行驶的扬尘,kg/km•辆;v—汽车速度,km/h;W—汽车载重量,t;2P—道路表面粉尘量,kg/m。一辆载重5t的卡车,通过一段长度为500m的路面时,不同表面清洁程度,不同行驶速度情况下产生的扬尘量如表6.2-1所示。91 广东现代国际展览中心二期扩建工程环境影响报告书表6.2-1不同车速和地面清洁程度时的汽车扬尘单位:kg/km•辆2P(kg/m)0.10.20.30.40.51.0车速(km/h)50.02830.04760.06460.08010.09470.1593100.05660.09530.12910.16020.18940.3186150.08500.14290.19370.24030.28410.4778200.11330.19050.25830.32040.37880.6371由上表可见,在同样路面清洁情况下,车速越快,扬尘量越大;而在同样车速情况下,路面清洁度越差,则扬尘量越大。根据类比调查,一般情况下,施工场地、施工道路在自然风作用下产生的扬尘所影响的范围在100m以内。抑制扬尘的一个简洁有效的措施是洒水。如果在施工期实施每天洒水4-5次,可有效控制车辆扬尘,将TSP影响范围缩小到20-50m,抑尘试验结果见表6.2-2。3表6.2-2施工场地洒水抑尘试验结果单位:mg/m距离5m20m50m100m不洒水10.142.891.150.86TSP小时平均浓度洒水2.011.400.670.60根据项目的四至情况可知,本项目附近的主要环境敏感点为溪头村和仁康医院,距离本项目最近的距离均大约为120m,根据上面的洒水试验的结果看,在采取洒水措施的情况下,33在距离100m处,TSP的小时平均浓度将由不采取措施的0.86mg/m降低到0.6mg/m,仍然超过TSP的环境质量小时浓度标准值。由于溪头村与本项目之间有一排建筑物的阻挡,本项目的扬尘将主要对前排建筑物(华庭花园酒店)造成影响,对后排溪头村的影响相对较小。而仁康医院位于本项目所在地次主导风向的下风向,与本项目隔路相望,项目在施工中的扬尘如不严格控制,在一定的气象条件下,对仁康医院将造成影响,使得仁康医院面向本项目侧的空气环境质量变差,TSP浓度超标。6.2.2施工废气环境影响分析施工废气主要为施工机械和设备、运输车辆排放燃油废气,主要污染物为柴油燃烧产生的CO、NOx、SO2等,该类大气污染物属于分散的点源排放,排放量由使用的车辆、机械和设备的性能、数量以及作业率决定。总体来说由于其产生量少,排放点分散,其排放时间有限,因此不会对周围环境及敏感点造成显著影响。但施工单位在施工过程中还是应该尽量使用低污染排放的设备,日常注意设备的检修和维护,保证设备在正常工况条件下运转。92 广东现代国际展览中心二期扩建工程环境影响报告书6.2.3施工营地临时食堂油烟废气环境影响分析本项目临时施工营地内设有食堂,其厨房在烹饪过程中会有厨房油烟废气产生,主要为燃料燃烧过程中产生的SO2、NOx、CO、烟尘等污染物和食用油脂受热挥发分解产物。厨房燃料使用液化石油气,产生的污染物含量较低,不会对大气环境造成显著影响。而食用油脂受热分解产生的污染物成分复杂,含有醛、酮、酸、脂等有机化合物,以及苯并芘等有害物质。油烟不仅产生刺激性气味而影响敏感人群,而且对人体健康有一定的危害,特别是有些餐饮业使用反复加热的食用油,或加热变质食品,会产生致癌性物质。可见,厨房油烟如不妥善处理,极易对周边环境造成严重的影响。本项目临时食堂就餐人数约400人,类比同类型餐饮,其灶头数应设三个左右,以中型餐饮考虑,按照国家《饮食业油烟排放标准》(试行)(GB18483-2001)的要求:“中型饮食3业单位油烟最高允许排放浓度为2.0mg/m且净化设施最低去除效率为75%‖。因此,本项目食堂厨房必须设置专用烟道,建议采用运水烟罩+静电油烟净化装置处理系统,该装置的油烟3处理效率可以达到75%以上,排放的油烟浓度可小于2.0mg/m。在采取上述措施的情况下,本项目厨房油烟对周边环境的影响可以接受。6.2.4装修废气环境影响分析按照污染源散发污染物及典型室内空气调查结果归纳出室内主要污染物有:挥发性有机化合物(VOC)、甲醛、氨气、颗粒污染物、CO和CO2、NO2、SO2和O3。本项目的建设内容包括展览馆、商务办公楼、地下室等,装修阶段将使用大量的建筑材料,不同建材产生的污染物见表6.2-3。表6.2-3不同建材排放的污染物室内污染物建材名称甲醛涂料、复合木材、壁纸、壁布、人造地毯、家具、泡沫塑料、胶粘剂等VOC(沸点50~250℃)涂料中的溶剂、稀释剂、胶粘剂、防水材料、壁纸和其它装饰品化合物(使用中缓慢释放)氨高碱混凝土膨胀剂-水泥加快强度剂(含尿素混凝土防冻剂)建筑及装饰材料的选用,直接影响到办公人员的生活环境及身体健康。如不采取必要的室内空气污染物控制措施,使其达到室内空气环境的相关标准,必将对人体健康造成极大的危害。长期生活在这样的室内环境中,会因污染物的不断累积而诱发各种疾病,危害人体健康。因此,应从初期规划阶段即重视室内环境空气的影响,在选择装修材料和涂料的时候应93 广东现代国际展览中心二期扩建工程环境影响报告书选用对环境污染小、有益于人体健康的建筑材料产品,室内装修材料应采用符合国家现行有关标准规定的环保型装修材料,防止装修材料中有毒、有害气体的挥发导致室内空气污染,危害人体健康。建设单位只要采用符合标准的建筑材料,保证建材、有机溶剂和辅助添加剂无毒无害,做到健康设计原则,基本不会对环境产生较大的影响。6.2.5环境空气污染防治措施项目在施工期间对大气环境的影响主要来自施工扬尘的影响,因此,施工期应按照《防治城市扬尘污染技术规范》HJ/T393-2007要求,采取下列措施对扬尘控制:①打围施工。建筑工地周边设置高度不低于1.8m的围挡,施工场地内所有土堆、料堆全部覆盖;采取袋装、密闭、洒水等防尘措施;同时严禁在车行道上堆放施工弃土。②硬化道路。项目施工场地道路硬化,并且种植施工道路旁绿化带,种植能吸附、阻隔尘埃的乔木和灌木和草坪,既能防尘,又美化了环境,从源头控制扬尘的产生。③设置冲洗设备专用设施。对运输车辆进行严格清洗,避免对道路交通道路造成扬尘污染;④湿法作业,施工场地干燥时适当喷水加湿,建筑施工风速四级以上时,拟暂停开挖,随洒水随清运垃圾,渣土要在3天内清运完毕。⑤配齐保洁人员。项目施工场地配备专职的保洁人员负责施工现场卫生管理工作,配备洒水设备。⑥定时清扫现场,选择对周围环境影响较小的运输路线,定时对运输线路进行清扫。⑦项目临时施工营地食堂厨房油烟采取运水烟罩+静电油烟净化装置处理系统进行处理。⑧在室内装修过程中尽量不要使用含有汞类、醛类、卤化物溶剂或者芳香族化合物等一些对人体影响很大、会造成人体健康损害的污染物,不使用铅、铬、镉等金属及其化合物的颜料和添加剂。装修材料的选择必须满足国家有关的放射性安全标准。同时,在室内种植某些植物,利用植物的吸收降低装修等过程产生的有毒有害气体。不得使用含氡的建材。可采用装修后活性炭吸附等方法,去除苯、甲醛等的污染。同时本环评要求:①不准露天搅拌混凝土,使用商品混凝土。②不准车辆带泥出门。对车辆进出进行严格冲洗,避免对城后路造成扬尘污染;③不准运渣车辆超载、冒载。运渣车辆,车箱遮盖严密后方可运出场外、严禁撒落。94 广东现代国际展览中心二期扩建工程环境影响报告书④不准高空抛撒建渣。⑤不准场地积水。若出现场地积水现象,及时抽水排水,并平整路面。⑥施工料具应当按照施工现场平面布置图确定的位置存放。水泥等可能产生尘污染的建筑材料应当在库房内存放或严密遮盖。存放油料必须有防止泄漏和防止污染措施。⑦不准现场焚烧废弃物。项目生活垃圾由市政环卫清运系统清运,建筑垃圾统一运输到东莞市指定的建筑垃圾堆放场地。所有垃圾分类存放,统一清运,不得在现在焚烧。总之,施工期须严格遵守各项规定的要求,对扬尘进行治理,以确保施工扬尘不对周边大气环境质量造成污染影响,达到保护环境,保障身心健康的目的。6.3水环境影响及污染防治措施6.3.1水环境影响分析地表水环境影响评价项目在施工期产生的废水包括施工人员生活污水和施工废水。施工人员不在施工现场食宿,施工期间施工人员生活污水主要来源于如厕和清洗废水,废水若直接排放将对地表水体产生不良影响。本报告建议项目设置化粪池对生活污水进行预处理,将预处理后生活污水接入项目北侧家具大道、南侧会展南路地下污水管道,排入东莞市厚街沙塘污水处理厂,对项目所在区域水环境影响较小。施工废水主要来自于施工机械设备和运输车辆的定期清洗,包括开挖和钻孔产生的泥浆水、机械设备运转的冷却水和洗涤水、混凝土搅拌车及输送系统冲洗废水、车辆清洗水,以及开挖基础时为降低地下水位的抽排水和工程开挖过程中可能产生的地下涌水等,施工废水中主要污染物为石油类和SS,悬浮物浓度达到1500~2000mg/L,如直接排放,会在一定程度上增加地表水污染负荷,项目可设置简易隔油沉淀池等措施对施工废水进行处理,处理后可回用于浇洒路面、车辆冲洗等,回用后余下的排入市政污水管道,对地表水环境影响很小。地下水环境影响评价根据地质勘探情况可知,项目所在区域地下水水位较浅,项目施工期开挖地下室时为降低地下水位抽排地下水,开挖过程中也可能产生一定的地下涌水。项目应合理安排施工时间,基础施工尽量避开地下水的丰水期,尽可能在枯水期进行抽排地下水,这样会大大的减少地下水抽排量,抽排后立即进行封堵;项目在开挖过程中及时进行基坑侧壁止水,涌水产生量较小。因此,项目基础开挖基本不会造成项目所在区域地下水位降低。95 广东现代国际展览中心二期扩建工程环境影响报告书同时,项目在地下室开挖过程中采用适合的基坑支护措施,及时排出地下涌水,不会给污染物进入地下水提供途径和通道,也能有效地阻止污染物的垂直下渗,对地下水水质影响很小。项目对施工营地污水处理设施(隔油沉淀池、生活污水处理设施等)进行防渗处理,再经过包气带的防渗作用,废水中污染物基本不会渗入地下水,不会造成地下水水质污染。6.3.2施工期水污染防治措施地表水污染防治措施(1)使用商品混凝土,且不在现场搅拌,以减轻污染。(2)在施工过程中应加强对机械设备的检修,以防止设备漏油现象的发生;施工机械设备的维修应在专业厂家进行,防止施工现场地表油类污染,以减小初期雨水的油类污染物负荷。(3)采取措施控制地表降尘积累,以减小降水前地表积累的污染负荷。(4)施工场地修建沉淀池,使生产废水沉淀后排放,沉淀池内淤泥定期清理,运往碴场堆放。(5)工程开始绿化的时候需要的生态用水和清洁用水较多。在项目施工时,可考虑采用目前相对较为先进的中水回用技术,收集小区内天然降雨及可循环利用的非污染水,待主体工程施工完成后,满足小区内绿化、清洁设施用水需求。(6)严格加强对施工人员的管理,施工人员不在施工现场食宿,在项目在建筑工人临时生活区内设置流动厕所处理生活污水,处理后方可排放。采取上述处理措施后,各类污水必须经处理达到《水污染物排放限值》(DB44/26-2001)第二时段三级标准后方可排入市政污水管网。地下水污染防治措施施工期对地下水环境的影响主要为施工废水和生活污水未经处理直接漫流排放,以及地下室开挖抽排水带来的影响,采取的措施如下:(1)本项目施工期产生的施工污水,特别是车辆冲洗废水,应收集经沉淀池沉淀后才排放,不得直接排放。96 广东现代国际展览中心二期扩建工程环境影响报告书(2)合理安排基础施工时段,避开地下水丰水期,尽量少抽排地下水;在开挖过程中及时进行基坑侧壁止水,采用适合的基坑支护措施,及时排出地下涌水,建议支护选择具有专业资质、且设计施工经验丰富的公司设计和施工。(3)本项目建设前应对地下空间开发时可能诱发的地质问题进行预测分析;工程建设前开展详尽的地质勘察工作,为设计施工提供需要的参数和指标;施工期间对整个工程进行系统监测,当出现问题时可以及时采取措施,保证施工和环境安全。(4)项目施工前进行必要的抽水实验或计算,以正确估计可能的涌水量,漏斗降深及影响范围,施工过程中注意严密监测地下水变化及时堵漏并修建防渗层、防渗墙或防渗帷幕以防止污染物外泄,施工完成后,应保证地下车库等地下工程的封闭性。(5)项目在施工过程中避免长时间集中抽水、排水,建筑场地周围应设置防渗性好,深度足够,闭合的止水帷幕,并确保施工质量,以免地下水流失过快形成大范围沉降漏斗。(6)为减轻施工中的地下水污染情况,应尽量采用污染小的建筑材料、化学浆液,施工污水、废浆和生活污水不能随意排放,建筑垃圾应及时处理,防止其下渗污染地下水。(7)在项目选址规划阶段要做好充分的地质勘察工作,了解场地的地质结构、地层岩性、地下水的埋藏深度、分布情况及走向、隔水层性质等;在施工阶段要做好充分的防渗设计,确保工程寿命期间满足防渗要求。6.4固体废物环境影响分析与污染防治措施6.4.1固体废物环境影响分析施工期间产生的固体废物主要包括弃土方和建筑垃圾,以及少量施工人员生活垃圾。生活垃圾影响分析施工人员生活垃圾具有以下特点:人均垃圾产生量相对建筑垃圾量而言较小,但其中有机物比例较高,无机物含量低,垃圾中的可燃物含量较高。在施工期间,由于施工人员不在施工现场食宿,由施工单位统一安排食宿,生活垃圾对施工现场及周边环境影响较小。建筑垃圾和弃土弃渣影响分析3项目施工期建筑施工产生的建筑垃圾总量约3.57万t,弃土弃渣约90.24万m,由于本项目建筑垃圾和弃土弃渣的产生量较大,若不得及时的合理处置,会对环境产生不良影响。97 广东现代国际展览中心二期扩建工程环境影响报告书建筑垃圾在不能得到及时清运的情况下,建筑垃圾中的弃土、砖瓦沙石、混凝土碎块等无机成分的影响主要表现为:在旱季,受季风的作用,垃圾中的比重较轻的(例如塑料袋、水泥袋碎片)和粒径稍小的尘埃随风扬起污染附近区域的大气环境和环境卫生。在雨季,随暴雨和地表径流的冲刷,泥沙将堵塞下水管涵、污染附近的水体等。开挖弃土弃渣若无组织堆放、倒弃,遇上暴雨冲刷,则会造成水土流大。项目所在地年降雨量大,暴雨频率高,强度大,极易引起工地水土流失,泥浆水还夹带施工场地上的水泥、油污等污染物进入水体,造成水体污染。另外,在运输过程中,车辆如不注意清洁运输,沿途撒漏泥土,污染街道和公路,影响市容和交通,尘土的撒漏也会给交通环境卫生带来影响。6.4.2固体废物处理处置施工期的固体废弃物有两类,一类是建筑垃圾和弃土,主要为无机类废物,也包括一些装饰材料中的有机成份,如废油漆、涂料等,其产生量虽然较小,但由于废油漆、废涂料中可能含有有毒有害成分,因此需对这些固体废物单独集中处理,另一类是施工人员的生活垃圾。固体废物主要处理措施包括:(1)建设单位或者施工单位对产生的建筑垃圾应当按照有关规定设置围挡,做到施工出入口硬化铺装并配备相应的冲洗设施,及时督促经核准的运输单位及时运输,保持工地和周边环境整洁。(2)建筑垃圾运输车应当按照有关规定设置密封式加盖装置并实施完全密闭式运输;建筑垃圾装载量不得超过车厢挡板;在驶离建筑工地前,车体应在建筑工地围护栏内冲洗干净;建筑垃圾运输车按规定的时间和路线行驶。(3)单位和个人因装饰装修房屋产生的建筑垃圾,应当按照物业管理企业或者街道办事处指定地点临时堆放,并采取措施围挡、苫盖,并在12小时内委托他人或者自行运输。运输应当采用袋装或者密闭的方式,防止途中洒落,在市城管部门指定的地点倾倒。(4)建设单位或者施工单位应当逐步实施建筑垃圾分类收集,最大限度地实现建筑垃圾资源化回收利用。对已经产生的建筑垃圾,应当争取就地处理、就地使用,尽量减少建筑垃圾的排放。对不能就地处理、就地使用的建筑垃圾,应当根据其建筑垃圾的类别运输至市主管部门指定的地点或者向综合利用企业交售。98 广东现代国际展览中心二期扩建工程环境影响报告书(5)建筑垃圾排放、运输、中转、回填、受纳实行联单和统计表制度。(6)对于如废油漆、废涂料及其内包装物等,属于危险废物,必须严格执行危险废物管理规定,由专人、专用容器进行收集,并定期交送有资质的专业部门处置。(7)对于施工工人的驻地,设立垃圾收集装置,并定期清运。对于施工现场施工人员活动产生的分散垃圾,除对施工人员加强环境保护教育外,也应设立一些分散的小型垃圾收集器(如废物箱),并派专人定时打扫清理后交由环卫部门处理,施工期少量的危险废物交有资质的部门处理。(8)施工单位必须严格执行余泥渣土排放管理的有关规定,按规定办理好余泥渣土排放的手续,获得批准后方可在指定的受纳地点弃土。(9)运输车辆必须按照指定的运输路线和时间行驶,运输过程中应装载适量,车厢上部必须覆盖篷布或采取其他有效措施,防治余泥渣土沿途洒漏、飞扬。运输余泥渣土的车辆驶离建设工地时,建设或施工单位应冲洗车体,保持车辆整洁。(10)建设过程中应加强管理,文明施工,使建设期间对周围环境的影响减少到较低限度,做到发展与保护环境相协调。99 广东现代国际展览中心二期扩建工程环境影响报告书第7章运营期环境影响分析及污染防治措施7.1水环境影响评价及污染防治措施7.1.1项目水污染源分析项目所排污水主要为生活污水。废水中主要污染物CODcr、BOD5、SS、NH3-N等。建设项目车库冲洗废水经隔油处理后,与生活污水一起经三级化粪池预处理后达到《水污染物排放限值》(DB44/26-2001)第二时段三级标准后,排入城市污水管网,进入东莞市厚街沙塘污水处理厂处理达到《城镇污水处理厂污染物排放标准》(GB18918-2002)一类B标准后排放。项目属东莞市厚街沙塘污水处理厂纳污范围。项目周边市政管网与厚街沙塘污水处理厂的衔接情况见附图7.1-1。东莞市厚街沙塘污水处理厂出水水质情见7.1-1。表7.1-1东莞市厚街沙塘污水处理厂出水水质项目CODcrBOD5SSNH3-N《城镇污水处理厂污染物排放标6020208准》(GB18918-2002)处理后水质<60<20<20<87.1.2污水正常排放的影响本项目在正常情况下,经过自建的化粪池等预处理后,进入市政污水厂进行处理达到一级B标准后排放,其污染物得到了大大的削减,削减量如下:表7.1-1项目处理设施及经过市政污水厂处理后的削减量单位:t/a污染物名称CODcrBOD5SSNH3-N预处理削减量31.29.434.40.3市政污水厂削减量145.984.469.88.5由于项目生活污水中污染物种类少,浓度较低。经过预处理后,再排入东莞市厚街沙塘污水处理厂,经过二级生化处理后污染物浓度进一步降低,对东莞运河影响较小。7.1.3地表水污染防治措施项目将采取措施,有效控制排水对周边水体的污染。措施如下:100 广东现代国际展览中心二期扩建工程环境影响报告书项目排水系统采用雨污分流制。规划用地内尽量采用透水性的道路广场铺装,建立地表径流过滤系统、绿化过滤带,提高雨水现场渗透量,降低地表径流量。项目所在地属于东莞市厚街沙塘污水处理厂配套管网集水范围,且项目周边污水管网已建成。东莞市厚街沙塘污水处理厂目前已投入使用,因此项目建设规划时只考虑对地下车库冲洗废水分别进行隔油处理后,与生活污水一起进行三级化粪池处理。废水经预处理后由市政管网排入东莞市厚街沙塘污水处理厂处理,最后排入东莞运河。地下水环境影响分析及污染防治措施7.1.4地下水环境影响分析评价区域地勘数据显示,项目评价区的地下水主要属于剥蚀台地谷地孔隙水。水源均由大气降水和地表水直接补给。研究表明,最常见的潜水污染是通过包气带渗入而污染,深层潜水及承压水的污染是通过各类井孔、坑洞和断层等发生的,他们作为一种通道把其所揭露的含水层同地面污染源或已污染的含水层联系起来,造成深层地下水的污染。随着地下水的运动,形成地下水污染扩散带。本项目生活污水化粪池拟进行防渗处理,严格接入市政管网,加强管理。密切关注项目内部的雨水排水,确保雨水能经项目地块内的雨水管网收集后排入市政雨水管网。对于垃圾站,则要求加强管理,收集的垃圾应及时外运,严禁把垃圾房内少量地面冲洗水直接扫出垃圾站以外绿化区,避免对地下水造成污染。如果项目设置备用发电机,则发电机房内的储油间及周边地面应采取防渗措施,储油间内应设置围挡设施,在发生意外泄漏时进行收集,引入事故池中收集,同时加强管理,避免渗漏现象发生。经过以上措施后,项目对地下水的影响较小。7.1.5地下水污染防治措施经分析,本项目的水污染物进入地下水的主要途径有:(1)化粪池、污水输送管道、污水收集池等底部的防渗层破裂、粘接缝不够密封或污水管道破裂等原因造成污染物的渗透,从而造成污染地下水。这种污染途径发生的可能性较小,但一旦发生,不容易发现,造成的污染和影响较大。为杜绝上述情况的发生,本项目建成后对化粪池等设施进行充分的地下防渗处理,本项101 广东现代国际展览中心二期扩建工程环境影响报告书目主要措施包括:一是施工前控制。针对大体积砼结构设计特征及季节特点,制订可行的浇筑方案。二是施工过程控制。减少每次浇筑的蓄热量,减少水化热的积聚,减小温度应力,混凝上采取斜面分层浇筑,同时混凝土中添加防渗腻子。三是严格控制振捣时间。拟采用插入式振动器。混凝土施工中充分振捣可使骨科和水泥浆在模板中得到致密排列,有助于混凝土的密实性和抗裂性的提高。四是控温措施。掺优质粉煤灰,降低水泥用量,减少水化热;加泵送剂,延长凝固时间,促使水化热峰值平滑;混凝土表面进行覆盖,采用麻包片和塑料布覆盖两层,以减少内外温差;尽量降低混凝土浇筑的温度。同时小区内的污水管道安装敷设均进行严格控制,确保工程质量,污水管道投入使用前进行管道闭水试验,确认各类管道不发生污水渗漏。(2)地表初期雨水未做防渗处理的渠道时,通过土壤下渗,造成地下水的污染。由于实施雨污分流,雨水管道设置合理,各类路面形成的初期雨水污染物浓度较低,但通过路旁设置的雨水管道可以进行充分收集,最终进入市政雨水管道,不会对直接渗入地下,造成地下水污染。因此,本项目采取的各类防渗措施得当,并且实施完善的雨污分流,可以确保项目运营期项目各类污水及受污染的初期雨水不会下渗影响地下水质,本项目对地下水环境影响甚微。7.2环境空气影响分析及污染防治措施7.2.1环境空气影响分析项目竣工投入使用后,其废气污染源有:机动车尾气、发电机尾气等,对周围环境造成影响的主要污染物为SO2、NO2及油烟等。根据对该项目的工程分析,通过资料复合法、物料平衡算法等确定该项目主要大气污染因子、排放浓度和源强,定性分析该项目各污染源及其污染物对周围空气环境的影响程度和范围。7.2.1.1备用发电机尾气本项目现在尚未能确定是否设备用发电机,有可能不设,如果设的话,将在展览馆两侧分别设一台1000KVA的备用发电机,设置于独立的备用发电机房内。柴油发电机组燃料拟采用含硫率小于0.2%的优质轻柴油,为保证发电机处于良好备用状态,每月试机时间按8小时计,全年最多工作96小时。102 广东现代国际展览中心二期扩建工程环境影响报告书目前东莞市供电较为正常,因而,该发电机机组使用的频率较为有限。柴油发电机在运行过程中排出的烟气含有SO2、NOx、烟尘等污染物。根据国家《关于执行大气污染物排放标准有关问题的复函》环函[2008]509号,对备用柴油发电机废气排放应控制烟气黑度,烟气黑度应达到林格曼黑度1级。对二氧化硫、氮氧化物、烟尘等污染物的排放应执行《大气污染物综合排放标准》(GB16297-1996)新污染源大气污染物排放限值中的二级标准。本项目规划意向是在展览馆A区的东西两侧设置发电机废气专用烟道,将废气分别引至展览馆楼顶(43m)排放。对照标准值,发电机尾气中各类污染物的排放速率均能满足标准。类比同类发电机可知,发电机废气中SO2等污染物排放浓度一般可以达标,但是烟气黑度一般难以达到一级的要求,因此,建议项目对备用发电机燃油尾气进行适当的处理,一般采用水喷淋的方式进行处理,烟尘浓度可降低约60%,SO2大约可降低20%,对NOX的去除率较低,本项目不考虑其处理效果。通过采取这些措施后,使得烟气黑度也达到相关要求,项目备用发电机对环境的影响可得到控制。表7.2-1发电机尾气污染物达标排放情况统计污染产生量产生速率排放标准排放量排气筒高度排放源是否达标物(t/a)(kg/h)(kg/h)(t/a)(m)展览区备SO20.0981.02314.6是0.0785用发电机NOx0.212.1924.525是0.21一烟尘0.0440.46022.65是0.0181000kW展览区备SO20.0981.02314.6是0.078543m(高出展用发电机NOx0.212.1924.525是0.21览馆楼顶二5m排放)烟尘0.0440.46022.65是0.0181000kWSO20.1962.0460.157合计NOx0.424.3840.42烟尘0.0880.920.035而且本项目备用发电机不是常用设备,仅在停电时应急使用,影响时间较短。项目把备用发电机设置在展览馆A区的东西两侧,每侧各一个排气口,共有两个排气口,其排气口在相应位置的屋顶,距离本项目南边界约为240m,距离南面的仁康医院住院部和溪头村居民楼的最近距离分别约为390m和420m,距离较远,一般来说,排气筒出来的废气经过扩散稀释后,对敏感点的影响不大。7.2.1.2机动车尾气影响103 广东现代国际展览中心二期扩建工程环境影响报告书由于国内外目前对地下车库的空气质量尚无明确质量标准。因此,对车库汽车尾气影响主要参照国内现行有关标准进行评估,其中:CO-执行卫生部《工业企业卫生设计标准》(TJ36-79)车间内最高允许浓度标准3(30mg/m);3NOx-参照GB3095-2012《环境空气质量标准》二级标准(小时浓度0.25mg/m);3NO2-参照GB3095-2012《环境空气质量标准》二级标准(小时浓度0.2mg/m)。根据建设单位提供的设计资料,项目地下层汽车库将设置平时排风系统(每小时换气6次,与消防排烟系统合用)。则项目地下车库内各污染物的浓度预测结果如下:表7.2-2加强换气措施后地下车库尾气排放情况污染物地下泊位项目NOXNO2CO初始浓度0.180.111.5外博大厦换气后浓度0.030.020.3969个标准值0.250.230是否达标是是是初始浓度0.480.294.1展览区换气后浓度0.080.050.7A、B标准值0.250.2302631个是否达标是是是初始浓度0.110.070.9C区换气后浓度0.020.010.2停车场标准值0.250.230600个是否达标是是是由上表可知,项目地下车库内的大气环境质量,与其通风次数密切相关,特别是展览区A、B的地下车库,若不进行强制通风换气,其内的大气环境质量将不能达标。项目所有地下车库的设计均按照《汽车库、修车库、停车场设计防火》规范进行,该规范要求地下车库的换气次数不少于6次/小时。根据本报告预测,当本项目地下车库执行换气次数不少于6次/小时的情况下,本项目地下车库的大气环境质量可以满足标准。机动车进入车库时排放的尾气为无组织排放。项目停车场与项目内车道是汽车尾气排放较集中的地方,建议采用合理设置通道、车位,加强管理等手段来减少塞车,减少汽车低速进出停车场,以降低NOX、CO和CH等污染物的排放,此外,还应加强首层及周边地区绿化,机动车尾气污染物通过自然通风以及绿地的净化,对项目内环境和外环境影响均较轻。104 广东现代国际展览中心二期扩建工程环境影响报告书地下停车场设有抽风排气系统,保证地下车库的换气次数满足要求,并收集车库废气由绿地中间排出,机动车尾气不会在车库累积,不会对周围环境产生明显不良影响。一般来说,无组织排放的影响范围主要在100m以内。本项目两个地下车库和一个地下地上停车场,共设置6个排气口,其中,距离周边敏感点最近的排气口位于本项目的南面的停车场排气口,距离仁康医院住院部和溪头村居民分别约为140m和250m,其余的排气口距离这些敏感点更远,由于距离比较远,而且在敏感点与本项目之间有非敏感建筑物的阻挡,一般来说,经过扩散后对敏感点影响不大。另外,项目区内多设置树木、草坪,扩大绿地面积,增大绿地功能,改善生态,减少机动车尾气的影响。7.2.1.3垃圾站臭气影响为便于垃圾的统一清运,项目设小型垃圾收集站主要收集项目内的生活垃圾,项目拟规2划在靠近会展南路一侧设置垃圾收集站位置,面积约72m。垃圾堆放过程中产生发酵臭气,主要污染物为H2S和NH3,此外还有甲硫醇、甲胺、甲基硫等有机气体。由于项目面向会展南路一侧,临近仁康医院,建议项目在垃圾站附近增加绿化建设,把垃圾站内的臭气引至绿化带内排放,废气口的位置距离溪头村和华庭花园酒店大约140m,距离仁康医院住院部大约280m,由于溪头村和华庭花园酒店位于本项目主导风向的上风向,一般情况下,对其影响不大,而仁康医院住院部位于本项目的下风向,由于本项目的垃圾站规模较小,而且主要收集的是办公垃圾为主,项目本身不设餐饮,无餐厨垃圾,垃圾站产生的恶臭相对较小,而且本项目距离仁康医院较远,如能采取妥当的处理措施和管理措施,对其不会造成明显的影响。项目产生的垃圾应以垃圾袋、垃圾桶集中收集,由垃圾车及时运往该垃圾站集中,再由清洁服务公司送往就近的垃圾填埋场或垃圾焚烧厂进行统一处理。生活垃圾日产日清,及时运至垃圾收集站,及时运出垃圾站,并加强管理,避免臭气对周边环境的影响。通过以上措施,垃圾收集站的环境影响将可得到有效控制。7.2.2环境空气污染防治措施项目采取措施控制废气污染源,其措施如下:105 广东现代国际展览中心二期扩建工程环境影响报告书(1)项目设有地下停车场,地下停车场设有抽风排气系统,保证地下车库的换气次数,并收集车库废气由绿地中间排出。另外,小区内多设置树木、草坪,扩大绿地面积,增大绿地功能,改善生态,减少机动车尾气的影响。(2)项目备用发电机燃油尾气通过内置烟井引至楼顶经水喷淋(添加碱液)处理后由专用排气筒高空排放。同时,应使用含硫率低的轻质柴油,并加入助燃催化剂,以促进燃油的充分燃烧。通过采取这些措施后,项目备用发电机对环境的影响可得到控制。(3)项目应在垃圾站周围加强绿化,把垃圾站内的臭气进行适当处理后引入绿化带排放,产生的垃圾应以垃圾袋、垃圾桶集中收集,由垃圾车及时运往该垃圾站集中,再由清洁服务公司送往就近的垃圾填埋场或垃圾焚烧厂进行统一处理。(4)在项目内加强绿化工作,以防治废气的污染。7.3声环境影响分析及污染防治措施7.3.1声环境影响分析7.3.1.1机房设备噪声影响分析本项目主要噪声源有备用发电机组、冷水机组、水泵、风机等,其噪声源强见下表。表7.3-1声源声级值声源声级范围dB(A)距离声源(m)声源数量水泵70-755地下室水泵房10风机65-755地下室风机房10配电房低频噪声5专用设备房6电梯机房低频噪声5专用设备房10外博大厦地下设备房7冷水机组80-855展览馆地下设备房8(A、B馆各4台)柴油发电机100-1055展览馆地下设备房2组可见,本项目除柴油发电机的工作噪声为100~105dB(A)外,其余设备的噪声级均在85dB(A)以下。(1)地下层设备房噪声影响分析根据类比监测调查,发电机在完全没有噪声防治措施的条件下,距离电机1m处的噪声源强达到100dB(A),在距离电机100m处的噪声值才能达到2类昼间标准60dB(A),106 广东现代国际展览中心二期扩建工程环境影响报告书在距离电机300m处才能达到2类夜间标准50dB(A)。因此,有必要采取噪声防治措施降低发电机噪声的环境影响。本项目备用发电机、加压水泵、风机以及变电所等设备大多安放在地下室内的专用设备用房内。设备用房墙壁对噪声的衰减值大约为25dB(A),再经过地下室墙壁的阻隔(衰减值约为15dB(A))和距离衰减作用(噪声距离衰减约5dB(A)),机械的噪声值达到地面的结果可见表7.3-2。表7.3-2机械设备噪声衰减情况昼间标设备名称原始值(单台)原始值(多台)衰减结果值夜间标准准备用发电机组(2台)105105(不同机房)60冷水机组(7台)8593.548.5冷水机组(4台)8591466050水泵(10台)759550风机(10台)759550从预测结果来看,机房设备噪声经过机房墙壁和地下室墙壁的阻隔以及空间距离的衰减后,到达地面时,冷水机组、水泵、风机等噪声基本可达到夜间2类标准,而备用发电机房噪声将超过夜间2类标准10dB(A)。因此,必须对发电机采用有针对性的噪声防治措施。(2)塔楼设备层噪声影响分析塔楼设备层设置专用的水泵房、风机房、变电房,同样,机械噪声经过设备房墙体阻隔和空间距离衰减后基本可达到相应的环境噪声标准,对周围的声环境没有明显的影响。7.3.1.2冷却塔噪声影响评价本项目拟采用低噪音型冷却塔(矩形),冷却塔共36台,其中展览馆A区屋面集中布置22台,外博大厦裙楼屋面集中布置14台。在未采取措施时,距离声源15米处单台冷却塔的噪声约为60dB(A)。本项目冷却塔布局与周边环境的关系见附图2.1-4,冷却塔的具体布置位置见本项目的总平面布置图。(1)预测模式①等效噪声源预测:采用声源叠加计算公式对多台冷却塔的噪声进行计算,预测等效噪声源强,计算公式如下n0.1LiLan10lg10i1式中:Lan—某点的叠加声级值,dB(A);Li—各噪声点在该点的声级。107 广东现代国际展览中心二期扩建工程环境影响报告书②噪声衰减预测:噪声影响评价中仅考虑声源的几何发散衰减,即当已知参照点(距离声源r0)的声级为L(r0),则预测点(距离声源r)的声级L(r)用下式计算r1L(r)L(r)20lg0r0式中:L(r)——预测点声级,dB;r0——参照点距声源点的距离,m;L(r0)——参照点声级,dB,r——预测距声源点的距离,m。点声源衰减公式:采用点声源衰减公式预测冷却塔到达南面敏感点的噪声;在项目边界处,当r1/r2≥1时,按点声源预测边界噪声,噪声随距离的衰减公式下式中:ΔL(r)——在距离点声源r1处至r2处的衰减值,dB;r——点声源至受声点的距离,m;④对于环境敏感点的噪声预测,首先利用上述公式计算声源在该环境敏感点处的总等效连续A声级,然后叠加该处的背景值,具体计算公式如下式中,Lpt-声场中某一点两个声源不同作用产生的总声级;L1-该点的噪声背景值;L2-另外一个声源到该点的声级值。(2)预测结果根据本项目冷却塔的布置情况及以上预测模型,得到项目在边界处及敏感点处噪声预测结果见表7.3-3。叠加现状噪声后,项目边界处噪声预测结果见表7.3-4。108 广东现代国际展览中心二期扩建工程环境影响报告书表7.3-3冷却塔噪声预测结果在预测点的噪单台噪声源强距噪声源距离噪声源预测点声贡献值[dB备注[dB]/距离(m)(A)]北面边界—54.3南面边界—48.1展览馆A区冷66/15m却塔(22台)西面边界—60.7东面边界—47.6北面边界—57.3南面边界—43.8外博大厦冷却66/15m塔(14台)西面边界—47.9东面边界—56.0仁康医院住院距项目南面边42.9部界122m由于距离外博大厦较远,仅考距项目南面边36台冷却塔敏感点华庭花园酒店43.3虑A馆屋面冷界120m却塔噪声对敏距项目南面边感点影响溪头村居民楼42.9界150m表7.3-4厂界噪声达标情况预测单位:dB(A)昼间夜间项目噪达预测点声贡献背景昼间超出达标背景预测昼间超出标预测值值值标准现状情况值值标准现状情况北面边59.068.5+0.554.2+6界69.060.2南面边49.562.5+0.253.5+1.5界62.755.0超60超标50标西面边60.961.2+2.952.3+9.2界64.161.5东面边56.669.2+0.254.8+4界69.458.83)评价结论109 广东现代国际展览中心二期扩建工程环境影响报告书本项目冷却塔距西边界的最近距离为65米,在西边界冷却塔噪声超过现状值昼间约为3分贝,昼间高达9.2分贝。另外,根据声环境现状监测结果来看,本项目用地区域声环境质量已经超标,因此,建议本项目对冷却塔进一步采取隔声措施,如设置隔声屏等措施,最大限度地降低冷却塔噪声。本项目周边最近的声环境敏感点仁康医院住院部、华庭花园酒店、溪头村居民楼距本项目南面边界的距离约120米,从表7.3-4预测结果看出,本项目冷却塔噪声到达该敏感点时小于43.3分贝,影响较小,而且本项目冷却塔在采取了隔声降噪措施后,进一步降低噪声,因此,本项目冷却塔在采取了有效地隔声降噪措施后,对华庭花园酒店、仁康医院住院部、溪头村居民楼不会产生影响。7.3.1.3停车场交通噪声影响分析项目规划地下停车场车位4000多个。根据对现有大型地下停车场的噪声监测结果表明,在平常时间(非上下班高峰期)),进出车库的车辆很少,一般不会发生交通堵塞,进出车库的路边交通噪声值基本上在65dB(A)以下,车辆噪声对周围环境的影响较小。在上下班高峰期,由于进入车库的车流量大幅增加,会造成车辆局部拥挤堵塞,车辆不停地怠速、加速和减速,进出车库的路边交通噪声值有时达到70dB(A)以上,使局部声环境质量变差。7.3.2噪声污染控制措施(1)将水泵、风机、配电房等置于地下室内,设备均应选用低噪低振机型,并采取隔声、消声、吸声及减振等综合措施。(2)柴油发电机拟采用的措施:①柴油发电机房全封闭处理,采用隔声门,并在建筑上做隔音吸音处理;采用双层隔声通风采光窗,设备基础加减震措施;②机房墙壁为240mm砖墙,双层玻璃隔声窗,隔声门、机房四壁顶棚挂贴吸声材料,护面为镀锌微孔板,以减少发电机房的混响声;③室内强制通风,采用低噪声风机,进、出风口安装消声器。(3)从冷却塔选型、风机排风口等进行控制,加强消声、隔声等降噪效果。根据前面的影响预测,本项目设置在展览馆A区的冷却塔在不采取措施的情况下,其噪声在西边的边界处超标,因此,本项目应对展览馆A区设置的冷却塔应设置隔声屏障,要求隔声效果达到8110 广东现代国际展览中心二期扩建工程环境影响报告书分贝以上,以降低项目噪声在边界处与现状噪声的叠加效果。隔声屏的位置应在冷却塔的外围距离冷却塔的边缘5m以内,高度应比冷却塔高出1m,建议把整个冷却塔区域围合起来进行设计,其周长大约为135m。(4)在区内周围道路两旁植树绿化,设置隔声带,以减少道路交通噪声对区内声环境干扰。通过采取以上措施后,本项目的噪声可以达到《社会生活环境噪声排放标准》(GB22337-2008)中的2类标准排放。111 广东现代国际展览中心二期扩建工程环境影响报告书7.4固体废弃物影响分析及污染防治措施7.4.1固体废弃物影响分析本项目运行期间产生的固体废物主要包括:办公垃圾、商业垃圾、废旧电池(属于危险废物)等。只要采取严格有效的管理措施,本项目运营期的生活垃圾不会对周围环境造成危害。另外,办公和商业垃圾中的废干电池、充电电池、含汞灯具等属于危险废物,如果收集、运送不当会对周围环境造成一定影响,也会影响本区域建成后的生活环境质量和城市景观。7.4.2固体废物污染控制措施项目拟采取的固体废物收集与处置措施如下:(1)对办公垃圾、商业垃圾,由物业管理部配专人清扫。(2)对生活垃圾日产日清,不隔夜堆放。将收集的生活垃圾统一交东莞市厚街镇环卫部门清运至垃圾处理厂,统一集中处置。(3)设立专门的危险废物收集点,让办公人员将危险废物主动交给危险废物管理处,收集后的危险废物应及时交给有资质的单位回收。7.5高楼风与日照影响分析7.5.1高楼风影响分析7.5.1.1高层建筑的局地风场(1)高楼风的形成影响建筑物四周气流形态及速度的因素相当多,它包括有逼近风的特性、风向、风速、建筑物本身的大小、几何外形以及邻近的建筑群等,气流可能因为高楼、高楼群的存在而被改变方向造成下冲、缩流、渠化、涡漩、角流及直尾流、遮蔽、穿堂风等等效应与现象。高层建筑在大风中对环境的影响,主要是会将高空强风引至地面,造成高楼附近局地强风,影响行人的安全和舒适性。(2)高大建筑附近的涡流成因分析112 广东现代国际展览中心二期扩建工程环境影响报告书建筑附近的涡流主要是风压作用引起的。风作用在建筑物上产生风压差。当风吹到建筑物上时,在迎风面上由于空气流动受阻,速度降低,风的部分动能变为静压,使建筑物迎风面上的压力大于大气压,在迎风面上形成正压区。在建筑物的背风面、屋顶和两侧,由于在气流曲绕过程中形成空气稀薄现象,因此该处压力将小于大气压,形成负压区,形成涡流。涡流区的大小与建筑物高度、长度、深度有关。见图7.5-1。图7.5-1建筑物高度、长度、深度的变化对漩涡区范围的影响当房屋的长度与深度不变时,涡流长度随房屋高度的增加而逐渐加大,涡流长度约为房屋高度的4~5倍;当房屋的高度与深度不变时,涡流长度随房屋的长度增加而增加;当房屋的高度与长度不变时,涡流长度随房屋的深度增加而减少。总之,房屋的高度越高,长度越大,深度越小,屋后旋涡区就越大。外博大厦塔楼高420米,裙楼高24米,底部裙楼长约70米的,高度大,但长度和深度小,涡流区相对较小。地下车库排风口若设在涡流区内,不利于污染物扩散,周边污染物浓度有可能超标。当地主导风向为东风、东南风,地下车库排风口应尽量选在东侧,可避开涡流区。气流分布与建筑物形状有关。横长建筑与细高建筑气流状况对比,见图7.5-2。图7.5-2横长建筑与细高建筑周围的气流状况113 广东现代国际展览中心二期扩建工程环境影响报告书高层建筑如建筑呈横长形时风速最大区为建筑上方,当建筑呈细高状时,风速最大区为建筑两侧,项目外博大厦的裙楼为横长形,裙楼顶将成为风速最大区;塔楼为细高状,塔楼两侧将形成风速最大区。(3)高层建筑对噪声的影响分析高层建筑的拔起,周边建筑空间的改变产生城市新的噪声源。首先建筑高度增加,风速加大,形成“高层风”的呼啸声,在建筑上的撞击声也越大,成为高层建筑特有的噪声源。其次,城市交通噪声和社会生活噪声,因有高层建筑阻挡不易迅速消失,而且还会在高层建筑上的玻璃和轻质金属的外装饰面材料,对声音大量反射形成回声而被增强。同时也延长了噪声干扰时间。外博大厦外装饰面主体为非金属和玻璃,减少了对噪声反射的介质。7.5.1.2“高楼风”对环境的危害及预防措施(1)衡量风环境状况的评价标准风环境的主要感受对象是人,如何评价风环境优劣,国内外建筑规范对城市环境的舒适风速和危险风速都没有一个统一标准。国内外研究人员为此作了大量的现场测试、调查统计和风洞试验。在同时考虑平均风速和脉动风速的情况下,提出行人的舒适感与风速之间较为具体的关系。根据文献,对于离地1.75m左右的行人高度高度处,平均时间为10分钟至1小时的平均风速V,行人舒适感与V的关系为:表7.5-1行人舒适感与V的关系平均风速(m/s)行人感觉V<5舒适5≤V<10不舒适,行动受影响10≤V<15很不舒适,行动受严重影响15≤V<20不能忍受V≥20危害调查统计显示:在建筑物周围行人区,若平均风速V>5m/s的出现频率小于10%,行人不会有什么抱怨;频率在10%~20%之间,抱怨将增多;频率大于20%,则应采取补救措施以减小风速。另外,行人在风速分布不均区域活动时,若在小于2m的距离内平均风速变化达70%,即从低风速区突然进入高风速区,人对风的适应能力将大减。所以,人在某位置是否安全、是否舒适,取决于该位置风速的大小及周围风速分布。(2)室外人员活动区域的风速分析:114 广东现代国际展览中心二期扩建工程环境影响报告书外博大厦塔楼高480m,裙楼高24米,长约70米,裙房顶可能形成风速最大区,结合东莞市的风玫瑰图,当地主导风向为东风,次主导风向为东北风,展览中心A、B馆及三期地块附近有可能形成涡流区。东莞多年平均风速为2.0m/s,累年最大风速为20.0米/秒,风向为东北风。东莞台风活动次数多,季节长,台风在每年7~9月出现最为频繁,这一气象条件为高楼风的形成创造了合适的外因。一般情况下即风速为2.0m/s左右时,属于轻风,人的行动无障碍,本项目高楼风对外界环境的影响较小;台风季节时,属狂风,本项目高楼风对人的行为影响表现为“危险”,须引起高度重视。本项目高楼风的影响主要表现:①本项目安装有玻璃幕墙,如果玻璃幕墙安装质量达不到能抗御高楼风的要求,则可能会导致玻璃幕墙中的玻璃坠落事件,也将对周边人群的人身和财产安全构成威胁。②高楼风导致地面风速过大,影响车辆和行人安全。因此,在项目设计时应重点和充分考虑高楼风对周边环境的影响,力争将影响降到最低。项目外博大厦塔楼呈细高状,风速最大区位于建筑物两侧,项目应进行风洞实验确定建筑物的实际风荷载,并在下一步结构设计中进行相应的抗风荷载设计。项目本身受风场的影响主要表现在台风状况下,由于楼体较高,承受的风负荷很大,并由此引起结构和流体的藕合振荡,从而危急建筑物的安全。根据有关记录,部分高楼幕墙受台风影响出现雪崩似的现象,造成了严重事故,因此,建议加强本项目幕墙的结构设计和抗风强度检验,杜绝意外事故发生。7.5.2日照影响分析外博大厦超高层建筑物,高度达480m。由于东莞地处南亚热带地区,位于北回归线以南,从方位来说,一般是南边的建筑物会遮挡北边的阳光;而且从季节来说,冬季影响大于夏季。。根据《东莞市城市规划技术规定》、《关于<东莞市城市规划管理技术规定>的更正、补充的通知》,非居住建筑(即本项目)与居住建筑的间距,应符合下列规定:非居住建筑位于居住建筑南侧或东西侧的,其间距应满足国家规定的日照条件。《城市居住区规划设计规范(GB50180-93)》的规定:“大城市住宅日照标准为大寒日≥2小时,冬至日≥1小时……”。115 广东现代国际展览中心二期扩建工程环境影响报告书项目周边的居住建筑主要分布在北面。根据日照分析图(见附图7.5-1),项目对北面居住建筑的日照没有影响,在大寒日可保证日照时间大于3小时,满足《城市居住区规划设计规范(GB50180-93)》的要求。7.6光污染影响分析7.6.1光污染及其危害国际上一般将光污染分成3类,即白亮污染、人工白昼和彩光污染。白亮污染:阳光照射强烈时,城市里建筑物的玻璃幕墙、釉面砖墙、磨光大理石和各种涂料等装饰反射光线;明晃白亮、眩眼夺目。人工白昼:夜幕降临后,商场、酒店上的广告灯、霓虹灯闪烁夺目,令人眼花缭乱,有些强光束甚至直冲云霄,使得夜晚如同白天一样,即所谓人工白昼。彩光污染:舞厅、夜总会安装的黑光灯、旋转灯、荧光灯以及闪烁的彩色光源构成了彩光污染。对于本项目,可能产生的光污染有白亮污染(主要为玻璃幕墙污染)和人工白昼(主要为灯光污染)两种。(1)白亮污染的危害专家研究发现,长时间在白色光亮污染环境下工作和生活的人,视网膜和虹膜都会受到程度不同的损害,视力急剧下降,白内障的发病率高达45%,还使人头昏心烦,甚至发生失眠、食欲下降、情绪低落、身体乏力等类似神经衰弱的症状。夏天,玻璃幕墙强烈的反射光进入附近居民楼房内,增加了室内温度,影响正常的生活。有些玻璃幕墙是半圆形的,反射光汇聚还容易引起火灾。烈日下驾车行驶的司机会出其不意地遭到玻璃幕墙反射光的突然袭击,眼睛受到强烈刺激,很容易诱发车祸。近年,由于建筑玻璃幕墙的广泛使用,在美化城市建筑景观的同时,一些反射率高的建筑玻璃幕墙也产生了光污染问题,引起了公众的投诉和环境保护主管部门的注意。“光污染”的发生一般应具备如下特定的条件:1)存在过量的光辐射源;2)使用了大面积高反射率镀膜玻璃;3)在特定方向和特定时间下产生;116 广东现代国际展览中心二期扩建工程环境影响报告书4)光污染的程度与玻璃幕墙的方向、位置及高度有密切关系。玻璃幕墙对太阳光的反射强度随镀膜玻璃反射率的不同而不同,同时光照度随距离的平方衰减。实践证明,光照度在100LX之内时,不会对人的视觉产生危害。根据测算,在夏天太阳光照射强度最大的天气情况下(94000LX),假定使用的玻璃幕墙反射率为40%,那么,距玻璃幕墙20m距离时,光照度在100LX之内,不会对人的视觉产生危害。由于行车的马路距玻璃幕墙的大楼都有较远的距离(60m以上),且《玻璃幕墙工程技术规范》(JGJ102-2003)中规定“玻璃幕墙应采用反射比不大于0.3的幕墙玻璃”,再加上汽车玻璃对幕墙反射光的阻挡作用,一般来说玻璃幕墙对行驶的驾驶员无大影响。(2)人工白昼的危害由于强光反射,可把附近的居室照得如同白昼,在这样的“不夜城”里,使人夜晚难以入睡,打乱了正常的生物节律,致使精神不振,白天上班工作效率低下,还时常会出现安全方面的事故。据国外的一项调查显示,有三分之二的人认为人工白昼影响健康,84%的人认为影响睡眠,同时也使昆虫、鸟类的生殖遭受干扰。甚至昆虫和鸟类也可能被强光周围的高温烧死。7.6.2本项目玻璃幕墙材料特性分析本项目玻璃幕墙拟采用Low-E玻璃,这种玻璃又称低辐射玻璃,其镀膜层具有对可见光高透过及对中远红外线高反射的特性,使其与普通玻璃及传统的建筑用镀膜玻璃相比,具有以下明显优势:(1)优异的热性能外门窗玻璃的热损失是建筑物能耗的主要部分,占建筑物能耗的50%以上。有关研究资料表明,玻璃内表面的传热以辐射为主,占58%,这意味着要从改变玻璃的性能来减少热能的损失,最有效的方法是抑制其内表面的辐射。普通浮法玻璃的辐射率高达0.84,当镀上一层以银为基础的低辐射薄膜后,其辐射率可降至0.1以下。因此,用Low-E玻璃制造建筑物门窗,可大大降低因辐射而造成的室内热能向室外的传递,达到理想的节能效果。室内热量损失的降低所带来的另一个显著效益是环保。寒冷季节,因建筑物采暖所造成的CO2、SO2等有害气体的排放是重要的污染源。如果使用Low-E玻璃,由于热损失的降低,可大幅减少因采暖所消耗的燃料,从而减少有害气体的排放。(2)良好的光学性能117 广东现代国际展览中心二期扩建工程环境影响报告书Low-E玻璃对太阳光中可见光有高的透射比,可达80%以上,而反射比则很低,这使其与传统的镀膜玻璃相比,光学性能大为改观。从室外观看,外观更透明、清晰,即保证了建筑物良好的采光,又避免了以往大面积玻璃幕墙、中空玻璃门窗光反射所造成的光污染现象,营造出更为柔和、舒适的光环境。Low-E玻璃的上述特性使得其在发达国家获得了日益广泛的应用。7.6.3光污染影响分析与评价(1)玻璃幕墙光污染分析本项目塔楼外墙以玻璃幕墙为主,适当地辅以具装饰性及功能性的外墙构件;裙房外墙采用石材,无玻璃幕墙。本项目周边有北面的居民楼和办公楼,夏天,如玻璃幕墙强烈光反射光进入居民楼或办公楼内,这些额外的辐射热将提高室内温度,影响居民的正常生活。如果玻璃幕墙是凹形弧面的,反射光一旦汇集还会引起火灾。根据建设方提供的资料,本项目的玻璃幕墙为低辐射镀膜夹层玻璃,不会形成聚集点,但是面对居民楼或办公楼的玻璃幕墙的强烈的反射光会一定程度地升高室内的温度,且强光照也将对楼内居民的正常生活造成一定的影响。《公共建筑节能设计标准》(GB50189-2005)第4.2.4条指出:“某个立面即使采用全玻璃幕墙,扣除各层楼板以及楼板下面梁的面积(楼板和梁与幕墙之间的间隙必须放置保温隔热材料),窗墙比一般不会再超过0.7”。从设计的角度要求,应选用低反射的新型材料、宜选用柔和中性的色彩,并在设计时考虑反射角度尽量减少对周边住户与办公楼以及周边道路的光污染。(2)灯光污染分析本项目如果夜间用灯光展现建筑物的景观,如果设计不当,有可能会对周边的仁康医院住院部、华庭花园酒店、溪头村居民楼造成人工白昼污染,对此本项目必须高度重视。目前我国没有灯光污染的标准和规范的情况,建议参照国际照明委员会(CEI)和发达国家有关规定和标准来防治光的污染。CEI对住宅干扰光照度进行了严格的规定,见表7.6-1。其中宵禁前的照度为住宅周边的垂直照度,宵禁后的照度为住宅窗户上的垂直照度。对于夜间的光污染,有一些量化的测试和评价指标。《绿色奥运建筑实施指南》推荐的“体育场、道路、主要夜景景点的照明在邻近公寓窗户上的垂直照度应小于5lx”,本项目也可参照该实施指南进行建筑物设计,以防止灯光污染的发生。118 广东现代国际展览中心二期扩建工程环境影响报告书表7.6-1CEI对住宅干扰光照度的限定7.7极限展会条件下对区域交通影响分析及交通改善措施7.7.1影响分析本项目的展馆主要为商贸功能,外博大厦主要为办公功能,一般不会因本二期扩建项目而引起极限会展条件,但是由于本项目一期、二期、二期扩建及三期均有会展展馆,其将来在举行会展的时候,将可能导致在短时间内出现大量的人流、物流的涌入,形成极限会展条件,届时,将对周边产生较大的影响,主要体现在交通影响上。2011年7月,广东现代国际展览中心有限公司委托东莞市新兰德城市规划技术服务中心编制完成《广东现代国际展览中心设计方案交通影响评价》,并已取得批复,详见附件。本报告引用《广东现代国际展览中心设计方案交通影响评价》成果,分析广东现代国际展览中心整体建成后对周边区域交通系统可能造成的影响。广东现代国际展览中心产生的交通影响显著,同时内部功能有所欠缺,主要表现如下:(1)对外部交通的影响较大,交通拥挤已经蔓延到博览快速等区域干道并产生显著影响;影响最为显著的莞太路—家具大道路口,因背景交通与项目交通量均较大,在极限会展期间交叉口交通量达到1万以上的流量,且交叉口流量在9:00~16:30期间变化幅度不大,影响时间较长。(2)内部交通功能与规模不足,主要表现在交通功能散漫,对行人集散、出租车临时停靠、公交临时增线、酒店巴士临时停靠等考虑不足,需统筹布局交通集散功能区域。(3)交通组织不完善,使得出入口及内部交通冲突与交织较多,部分地下车库出入口交通压力较大,交通蔓延出项目区域进而影响到周边道路设施。同时项目步行交通较多,欠缺与周边设施的行人通道,并影响道路机动交通效率,特别是与穗莞深城际轨道交通的距离较远、关联性弱,不利于发挥轨道交通对展览中心的服务能力。119 广东现代国际展览中心二期扩建工程环境影响报告书图7.7-1交通影响显著的路段及交叉口示意图图7.7-2项目内部交通问题示意图120 广东现代国际展览中心二期扩建工程环境影响报告书7.7.2交通改善措施根据以上分析,会议展览中心规模大,会展活动的交通需求高、影响范围广,对周边交通设施影响较大,已有规划道路网络无法满足交通运行需求,需采取内外兼治、软硬兼施的交通解决对策。主要为快速、安全、有序等3个方面。快速措施为增加交通设施、减少交通需求;安全措施为减少交通冲突;有序措施为交通流分离、交通组织与引导。评价在交通影响程度分析的基础上,结合临时交通管制手段,提出适宜的交通改善措施,包括外部交通改善和内部交通改善两个层面的建议:外部交通方面,增加外围区域的交通通道,强化项目与区域干线的联系,提高重要节点通行能力、增加公交与巴士、加强临时交通管制与引导、增设轨道交通出入口设置、完善行人设施布局。内部交通方面,完善内部交通功能布局、优化项目出入口方案、改善内部交通组织、提升重要集散通道的步行交通品质,提高其他交通方式的分担比例。7.7.2.1优化行人与公交设施,提升公共交通服务能力加强项目与周边公共交通设施的联系,预留出口及地下通道用地,增设轨道交通R2线、穗莞深城际线站点通往本项目的出站口,并在地下通道中设置行人传送带,创造条件提升轨道交通服务水平。结合周边公交站点,统筹安排行人过街设施,在家具大道与会展西路交汇处、外博大厦以及莞太路东溪路交汇处增设立体行人过街设施。在项目周边轨道交通R2线会展中心站、穗莞深城际轨道厚街站点周边预留公交首末站用地,增设与厚街镇内部联系的公交线路。优化区域常规公交线网,充分利用厚街镇新汽车站,加强项目与常平火车站、火车东站、广深港客运专线虎门白沙站以及周边城市机场、车站、港口的公交联系;在会展期间增开临时线路,以大运量常规公交增强集散能力。121 广东现代国际展览中心二期扩建工程环境影响报告书图7.7-3提升公共交通服务能力措施的示意图行人与公交改善措施说明:R2线站点距离外博大厦约450米,穗莞深城际线站点距离III区展馆约300米,步行时间分别约6.5分钟、4.5分钟。距离较远,轨道交通对本项目的服务能力较弱,有必要增设行人传送带,加强轨道交通的辐射能力。增设地铁出入口地下通道至项目附近并设置传送带后,将有效提高地铁对项目的辐射能力,吸引更多的客流选择地铁出行;增设立体过街设施,提高行人过街安全系数,并且减少机动交通与行人的冲突,提高道路通行能力;公共交通承担的客流比例将有所提高,重大会展期间乘坐地铁的项目客流增加1200人次/小时,极限会展期间增加2400人次/小时。小汽车高峰小时出行将减少,重大会展期间机动交通减少约500pcu/h(即高峰小时机动交通约4250pcu),极限会展期间机动交通减少约1000pcu/h(即高峰小时机动交通约6500pcu),对缓解周边交通拥堵发挥了一定作用。7.7.2.2增强区域交通分流能力,转移区域过境交通区域交通改善重点考虑长途交通、过境交通的快速通过,管理措施与交通设施升级都可以起到很好的作用。管理措施方面需加强交通引导,交通设施升级方面主要考虑区域交通分流与转移。加快推进影响区内交通信息化建设,以智能化交通提高区域交通效率,在区域交通干线122 广东现代国际展览中心二期扩建工程环境影响报告书上提前设置电子显示屏,在会展及其他重大活动举行时(情形二),及时告示车辆绕行并提示绕行推荐方案,引导项目交通准确、快速到达,减少不必要的车辆进入拥挤区域。如在南北向的广深高速公路、沿江高速公路、沿海公路、港口大道、莞太路、博览大道,以及东西向的东莞大道延长线、番莞高速公路、常虎高速公路新联支线等交通干线的出入口及重要交通节点设置交通指引。准快速化改造港口大道、东溪路、厚街大道(或厚街南环路)。与环莞快速路构成高速公路外的第二圈层快速集散系统,增加区域交通分流通道,减轻家具大道、S256交通压力。厚街南环路东延至环莞快速路二期,与环莞快速路二期形成互通立交或进行右进右出交通组织。东溪路升级为准快速道路,主线不少于6车道,与环莞快速路二期、港口大道衔接;与莞太路交叉应建设立交(推荐苜蓿叶型)。同时建议东溪路主要承担货运功能,家具大道主要承担客运交通功能。增设快速通道连接番莞高速公路和沿江高速出入口,快速通道接入会展南路与会展中路交叉口附近。在S256大修完成后,进一步减少、整合厚街镇S256上的出入口,并对有必要留下的出入口做渠化等优化处理,在满足沿线市民出行需要的前提下,尽量减少市民出行对S256交通流的干扰,提高通行能力。区域交通措施说明:以上措施是厚街镇举办大型活动期间所需配备的必要交通条件,将有效引导大型活动区域内交通转移,减少活动区域的过境交通,提高区域路网承受能力。同时构建除高速公路外的第二圈层集散通道,是项目交通在区域层面快速进出的前提条件。大型会展活动期间,东溪路准快速化对分流家具大道的货运交通,使得家具大道对项目的承受能力增加较多,同时使得项目四周有S256、东溪路、会展东路以及西部快速通道(连接沿江高速、番莞高速)等快速通道,使得项目具备良好的区域交通集散条件。7.7.2.3极限会展实施分级管制,完善管制区内交通设施参考广州琶洲交易会期间交通有限供给的策略,综合考虑重大会展与极限会展对周边道路与交叉口的交通需求,划定交通管制区,重点围绕管制区内的交通设施改善提出措施,如增加日常交通供给能力,避免无关交通进入交通繁忙区,缓解交通压力。以项目为中心,以家具大道、莞太路、东溪路、厚岗路为界,划定一个交通管制区域(除123 广东现代国际展览中心二期扩建工程环境影响报告书项目外,用地约50公顷,计容建筑面积约50万。其中规划建筑面积约40万,非规划建筑约10万),提示车辆绕行,减少不必要的交通进入本区。7.7.2.4优化管制区内交通组织,引导项目交通进出有序极限会展期间需采取临时管制措施,对交通拥堵严重的路口、路段进行交通管制,实行专用左转或部分方向限行等措施组织交通,使得进出交通与周边道路设施的通行能力匹配,引导项目交通进出有序。根据有序引导、就近停车、集中地点上下客、实施人车分离减少冲突、统筹管理等交通理念,项目周边组织4个主要到达方向,分别为家具大道西往东、莞太路(S256)北往南、会展南路西往东、会展中路南往北,并完善城市道路标志标示系统。家具大道—莞太路交叉口禁止家具大道的交通在交叉口左转。家具大道—厚岗路交叉口禁止厚岗路的交通在交叉口左转。家具大道路段(莞太路至厚岗路)上的机动车出入口右进右出,同时在会展中路、厚岗路交叉口东侧设置调头匝道。会展南路—会展中路交叉口实行右进右出,限制会展中路直行及左转。会展南路—康乐南路交叉口实行右进右出,限制康乐南路直行及左转。会展南路—会展西路交叉口允许西往北(会展南路左转进入会展西路)左转。管制区交通组织与引导措施说明:区域交通组织根据参展人流以及商务办公人流的来源地,根据广州、深圳以及周边镇街到达本区的重要通道,组织项目交通分散到家具大道、莞太路、东溪路、会展南路(东)进入,避免项目交通过于集中。同时对次要交通方向采取禁限措施、增加绕行,便于主要交通方向进出,并提高路网运行效率。管制区内交通组织优化后,将使得相关道路及交叉口的通行能力进一步提高,提升路网服务水平。7.7.2.5优化项目内部交通布局,确保内部畅通无阻项目内部分成6个到达、离开区,其中2个为专为小汽车进出车库服务,2个为专为临时交通集散服务,2个兼顾小汽车入车库和临时交通集散服务;自行车方式到达的,结合行人广场布设。项目内部设置3个交通集散中心,分别设在项目的北、东、南三个方向。主要为出租车、酒店巴士、公交、大巴等提供上下客服务,以及人流集合、疏散等,使得交通环境提升,交124 广东现代国际展览中心二期扩建工程环境影响报告书通行为有序,提高交通效率。项目内部道路组织3个单向循环,出入口为6进6出。内部交通布局与组织措施说明:项目内部交通功能,根据交通方式特征,在区内不同方向布置临时上下客的交通集散中心,引导交通有序运行。该措施可根据各区交通方式的特征启用。项目内部交通组织流线清晰,机动车入口在上游、出口在下游,便于车辆就近出入;交通组织依靠S256、会展中路构成了3个单向循环(6进6出,每个循环由2条车道构成),减少了机动车的交织与冲突,提高内部道路效率与通行能力。7.7.2.6优化地下车库出入口,提高交通进出能力为应对会展期间停车需求急剧增加,会展期间应统筹展区泊位,实行统一管理,泊位共享,高效周转。同时地下停车场建设完善的、连通穿行道路系统,方便泊位共享,提高地下车位的使用率。采取公交与步行设施优化措施后,项目交通高峰小时单向6133pcu,现有5进5出的车库出入口方案不能满足需求,地下车库出入口应根据内部道路交通组织方案调整进出布局,并增设地下车库入口。项目入口应设置在次干路或支路上,确需在主干路(如家具大道、会展南路)上设置入口的,距离市政道路出入口需预留不少于50米的排队缓冲车道,避免进库车辆对相邻道路的影响。项目地下车库出入口,应考虑极限会展高峰时段交通集散要求高、出入口通行需求大等情况设置。外博大厦设有1045个停车泊位,根据规范要求,出入口数量不少于3个。需增设一个入口,同时根据交通组织将靠近展馆A的出口调整为入口。I展馆高峰期进入车库的交通量约1450pcu,根据交通组织方案,应靠近外博大厦侧设置2个入口,同时北入口需调整为出口。II展馆高峰期进入车库的交通量约1200pcu,根据交通组织方案,在展馆C侧至少2个出口,并将会展中路南附近的入口适当北移。III展馆高峰期进入车库的交通量约2300pcu,其地下车库出入口全部面向会展西路,将导致会展西路交通压力过大;根据交通组织方案,在会展中路方向增加2个入口(靠家具大道)和2个出口(靠会展南路),同时将会展西路上南出口调整为入口,北入口调整为出口。125 广东现代国际展览中心二期扩建工程环境影响报告书车库出入口措施说明:通过出入口组织优化、停车共享等措施,有利的引导车流选择合理的地块出入口和停车库出入口,较好的改善了高峰期部分出入口较长排队的现象。地下车库入口在交通组织流向的上游,出口在交通组织流向的下游,使得中间行人有更多的空间往返于各展馆之间。7.7.2.7落实交通集散功能区,规范临时交通行为在外博大厦、东侧市政广场、展馆III区等3处增设交通集散中心,规范临时上下客交通运行。集散中心设施规模以重大会展交通需求进行配建。交通集散中心A出租车位14个、大巴停车位57个;交通集散中心B出租车位25个、大巴停车位69个;交通集散中心C出租车位4个、大巴停车位40个。集散中心的空间按照极限状态交通需求预留。交通集散中心A要求I区展馆北侧后退用地红线76米,同时外博大厦北侧后退用地红线39米;拆除外博大厦南侧展览馆A建筑,用做广场用地;交通集散中心B需临时使用东侧市政广场,面积约3万平方米;交通集散中心C要求III区展馆建筑南侧退后用地红线85米。交通集散中心说明:交通集散中心集步行、公交、巴士等交通方式于一体,有助于减少临时交通对道路的干扰,使得交通行为有序进行、提高道路使用效率;有助于减少行人在道路上停留的时间,提高参观人员安全系数。集散中心交通功能布局考虑了大巴及公交进出及上下客的场地,,减少区外绕行;另一方面,既满足了出租车的停靠,又提供了出租车排队候客场地,符合实际运行需求。较好的解决了人、车的集散需求,车辆组织流线清晰,功能完善。7.7.3交通改善后评价以上交通改善措施可分为项目内部交通与外部交通两个方面,内部交通改善措施包括项目内部交通单向组织、优化地下车库出入口、增设交通集散中心等;外部交通包括行人设施、公交设施、区域道路、周边道路等方面的改善。本节交通改善后评价主要侧重于外部道路与交叉口评价。7.7.3.1改善后项目交通流量路径分配126 广东现代国际展览中心二期扩建工程环境影响报告书根据到达交通的主要方向,完善主要途径的交通设施,引导交通有序运行,系统提高道路网络的服务水平。同时通过交通组织优化,引导各方向的交通流从6个节点进入,并使得各进口的交通流量基本平衡,避免交通集中带来的拥堵。7.7.3.2改善前后路段饱和度变化改善后道路交通需求变小,重新分配的路网上可以得到改善路网的饱和度情况,如下图所示。通过小汽车使用引导、方式结构优化、微循环等设施改善,研究项目周边的道路饱和度较改善前的饱和度状态有所降低,原过饱和路段饱和度降至0.90之内,处于基本可接受状态。7.7.3.3改善前后仿真对比应用交通仿真计算测试改善前后项目周边主要道路交通运行情况,改善前后对比如下图所示。仿真对比可以看出临近莞太路-家具大道交叉口的路段交通状况有所改善,主要因为出入口引入内部,减少了与外围道路车流的冲突。交通拥堵缓解改善前改善后图7.7-4交通改善前后仿真情况对比7.7.3.4主要路口改善情况改善后道路交通流量降低,项目周边主要交叉口交通压力有所减少,情况如下表所示。改善后,主要交叉口服务水平均有所提升,由最差的F级提升为E级,交叉口处于勉强可以接受状态。小结可见,广东现代国际展览中心原交通组织设计不尽完善,经采取一系列的交通改善措施后,道路交通流量降低,项目周边主要交叉口交通压力有所减少,对周边路网的压力减轻,交通拥堵情况将得到改善。7.8外环境对本项目的影响及污染防治措施127 广东现代国际展览中心二期扩建工程环境影响报告书7.8.1外环境污染影响分析7.8.1.1周边工业废气现状监测时,项目位于下风向,根据现状监测结果,项目区SO2、NO2、PM10浓度达到《环境空气质量标准》(GB3095—2012)中的二级标准要求,苯、二甲苯浓度能满足《工业企业设计卫生标准》中居住区大气中有害物质的最高容许浓度。甲苯参照―前苏联(1974)居住区大气中有害物最大允许浓度‖的规定。可见,周边工业大气污染源对本项目的影响较小。本节重点分析周边道路对外博大厦的影响程度。7.8.1.2城市道路1、交通噪声对项目影响的预测与评价(1)预测模式及相关参数本评价采用《环境影响评价技术导则声环境》(HJ2.4-2009)中推荐的噪声预测模式预测项目拟建道路营运期的交通噪声影响。①基本预测模式a)第i类车等效声级的预测模式:N7.5i12L(h)(L)10lg()10lg()10lg()L16eqiOEiVTri式中:i—车辆类型,i=1,2,3,即分大型车、中型车、小型车共三种类型;L(h)—第i类车的小时等效声级,dB(A);eqi(L)—第i类车速度为Vi,km/h;水平距离为7.5米处的能量平均A声级,dB(A);oEir—从车道中心线到预测点的距离,m;(A12)适用于r>7.5m预测点的噪声预测;Vi—第i类车的平均车速,km/h;T—计算等效声级的时间,1h;Ψ1、Ψ2—预测点到有限长路段两端的张角,弧度,见图7.8-1所示;128 广东现代国际展览中心二期扩建工程环境影响报告书A12P图7.8-1有限路段的修正函数,A—B为路段,P为预测点ΔL—由其他因素引起的修正量,dB(A),可按下式计算:ΔL=ΔL1−ΔL2+ΔL3ΔL1=ΔL坡度+ΔL路面ΔL2=Aatm+Agr+Abar+Amisc式中:ΔL1—线路因素引起的修正量,dB(A);ΔL坡度—公路纵坡修正量,dB(A);ΔL路面—公路路面材料引起的修正量,dB(A);ΔL2—声波传播途径中引起的衰减量,dB(A);ΔL3—由反射等引起的修正量,dB(A);Aatm—空气吸收引起的倍频带衰减dB;Agr—地面效应引起的倍频带衰减dB;Abar—屏障引起的倍频带衰减dB;Amisc—其他多方面效应引起的倍频带衰减。b)总车流等效声级为:0.1Leq(h)大0.1Leq(h)中0.1Leq(h)小L10lg(101010)eqj如某个预测点受多条线路交通噪声影响(如高架桥周边预测点受桥上和桥下多条车道的影响,路边高层建筑预测点受地面多条车道的影响),应分别计算每条车道对该预测点的声级后,经叠加后得到贡献值。②修正量和衰减量的计算A)线路因素引起的修正量(ΔL1)a)纵坡修正量(ΔL坡度)公路纵坡修正量ΔL坡度可按下式计算:大型车:ΔL坡度=98×βdB(A)129 广东现代国际展览中心二期扩建工程环境影响报告书中型车:ΔL坡度=73×βdB(A)小型车:ΔL坡度=50×βdB(A)式中:β—公路纵坡坡度,%。项目周边道路较为平坦,纵坡按0.3%考虑,大、中、小车型的纵坡修正量分别为0.3dB(A)、0.2dB(A)、0.15dB(A)。b)路面修正量(ΔL路面)不同路面的噪声修正量见表7.8-1。表7.8-1常见路面噪声修正量单位:dB(A)不同行驶速度修正量,km/h路面类型3040≥50沥青混凝土000水泥混凝土11.52道路使用沥青混凝土路面,路面噪声修正量为0dB(A)。B)声波传播途径中引起的衰减量(ΔL2)a)障碍物衰减量(Abar)①声屏障衰减量(Abar)计算无限长声屏障可按下式计算:231t40f10lg,(t1)1t3c4arctgLB1t3t2140f10lg,(t1)2ln(tt21)3c式中:f—声波频率,500Hz;δ—声程差,m;c—声速,340m/s。有限长声屏障计算:Abar仍由以上计算。然后根据图7.5-2进行修正。修正后的取决于遮蔽角β/θ。图2(a)中虚线表示:无限长屏障声衰减为8.5dB,若有限长声屏障对应的遮蔽角百分率为92%,则有限长声屏障的声衰减为6.6dB。130 广东现代国际展览中心二期扩建工程环境影响报告书图7.8-2有限长度的声屏障及线声源的修正图②高路堤或低路堑两侧声影区衰减量计算高路堤或低路堑两侧声影区衰减量Abar为预测点在高路堤或低路堑两侧声影区内引起的附加衰减量。当预测点处于声照区时,Abar=0;当预测点处于声影区,Abar决定于声程差δ。由图7.8-3计算δ,δ=a+b-c。再由图7.8-4查出Abar。图7.8-3声程差δ计算示意图131 广东现代国际展览中心二期扩建工程环境影响报告书图7.8-4噪声衰减量Abar与声程差δ关系曲线(f=500Hz)③农村房屋附加衰减量估算值近似计算按表7.8-2取值。132 广东现代国际展览中心二期扩建工程环境影响报告书表7.8-2农村房屋噪声附加衰减量估算量建筑物排序房屋占预测点与路中心面积噪声衰减量dB(A)40~60%3.0第一排70~90%5.0每增加一排增加1.5其余各排继续增加排数最大取值10外博大厦与周边建筑物的高度相差大,本报告不考虑外博大厦周边建筑物的遮挡作用。房屋附加衰减量按0dB(A)考虑。b)Aatm、Agr、Amisc衰减项计算按《环境影响评价技术导则—声环境》(HJ2.4-2009)正文8.3.4—8.3.7相关模式计算。外博大厦与周边道路声波传播途径中引起的衰减量(ΔL2)为0dB(A)。C)由反射等引起的修正量(ΔL3)a)城市道路交叉路口噪声(影响)修正量交叉路口的噪声修正值(附加值)见表7.8-3。表7.8-3交叉路口的噪声附加量受噪声影响点至最近快车道中轴线交叉点的距离(m)交叉路口(dB)≤40340<D≤70270<D≤1001>1000周边道路在本项目路段无交叉路口,交叉口噪声附加量为0dB(A)。b)两侧建筑物的反射声修正量地貌以及声源两侧建筑物反射影响因素的修正。当线路两侧建筑物间距小于总计算高度30%时,其反射声修正量为:两侧建筑物是反射面时:ΔL反射=4Hb/w≤3.2dB两侧建筑物是一般吸收性表面:ΔL反射=2Hb/w≤1.6dB两侧建筑物为全吸收性表面:ΔL反射≈0式中:w—为线路两侧建筑物反射面的间距,m;Hb—为构筑物的平均高度,h,取线路两侧较低一侧高度平均值代入计算,m。本项目建筑物间距小于高度的30%,且建筑物表面为一般吸收表面,取其反射声修正量为1.6dB(A)。133 广东现代国际展览中心二期扩建工程环境影响报告书(2)车流量车流量根据《广东现代国际展览中心设计方案交通影响评价》成果,引用道路规划设计车流量;车型比参照现状监测结果。统计结果如下:表7.8-4周边道路车流量昼间(辆/h)夜间(辆/h)规划车流量*设计车速道路名称(pcu/h)(km/h)小型车中型车大型车小型车中型车大型车省道S25680006026733842991235200193会展南路2800501874297192982146129家具大道54005036025543861789268246注:规划车流量*引用《广东现代国际展览中心设计方案交通影响评价》成果。3)道路相关参数表7.8-5道路相关参数道路道路红线或路幅宽度(m)现状车道数规划情况外博大厦建筑红线名称等级(现状/规划)(双向)与道路边界距离省道S256省道508拓宽到双向10车道东380m城市主/北40m家具大道48/606干路城市次城市主干道,双向6南355m会展南路21/304干路车道4)预测点外博大厦,与周边道路高差极小,因此不考虑高差影响。预测点与周边道路的距离见表7.8-6。预测点位见附图7.8-1。表7.8-6预测点与周边道路的距离距道路边线(m)噪声源敏感点高度省道敏感点会展南路家具大道S2561#外博大厦1层1F,高1.2m2#外博大厦20层20F,高94m3#外博大厦50层50F,高232m380355684#外博大厦80层80F,高370m5#外博大厦102层102F,高480m5)预测结果及评价根据预测模式及道路相关参数,预测周边道路交通噪声对外博大厦的影响见表7.8-7。134 广东现代国际展览中心二期扩建工程环境影响报告书表7.8-7噪声影响预测结果单位:dB(A)现状监测超出现状超出标准预测点预测时段楼层贡献值评价标准值值量1层70.0768.81.270.0720层68.21//昼间平均50层65.34//70达标80层63.29//102层61.89//外博大厦1层67.4254.213.2212.4220层65.59//10.59夜间50层62.78//7.785580层60.76//5.76102层59.37//4.37根据预测结果,在受周边道路交通噪声的影响下,外博大厦夜间超标量较大,最大超标12.42dB(A),昼间最大超标0.07dB(A);但与现状监测结果对比,昼间超出现状仅为1.27dB(A),夜间超出现状值较大,约13.22dB(A)。由于外博大厦每日办公时间集中在白天8:00~18:00,尽管夜间超出现状值较大,但本报告按昼间预测结果提出交通噪声防治措施。根据《广东现代国际展览中心设计方案交通影响评价》,会展期间,上述道路的车流量小于道路规划设计车流量,因此,会展期间周边道路交通噪声影响将小于预测结果。可以看出,随着车流量的显著增加,外博大厦受周边交通噪声的影响增大,需采取一定的隔声措施,保证办公环境对安静的需要。2、汽车尾气影响分析类比一般城市规划主干道汽车尾气排放情况,主干道在达到设计车流量后,汽车行驶过3程中排放的NO2一次浓度最大值为0.26mg/m,占标率为130%;CO一次浓度最大值为2.193mg/m,占标率为21.9%,最大落地出现在距离道路中心线30米的地方,本项目与家具大道最近距离为90米,可以看出,家具大道行驶车辆排放的汽车尾气可能对项目产生一定影响。7.8.1.3城市轨道交通1、东莞市城市快速轨道交通R2线(东莞火车站~东莞虎门站段)本报告引用《东莞市城市快速轨道交通R2线(东莞火车站~东莞虎门站段)环境影响报告书》成果,分析“东莞市城市快速轨道交通R2线(东莞火车站~东莞虎门站段)”地下段振动、地面车站风亭及冷却塔的噪声以及沿线风亭排放的废气可能对外博大厦产生的不良影响。135 广东现代国际展览中心二期扩建工程环境影响报告书R2线是东莞市轨道交通路网中连接东莞西北部与西南部的直径线,途径了石龙、茶山、东城、南城、厚街、虎门等东莞经济最为发达、最具活力地区。R2线起点为拟建的广深铁莞火车站,终点为东莞虎门站。线路走向为:东莞火车站——莞排路——莞龙路——东城中路——东莞大道——省道256线——东莞虎门,工程线路全长37.8km,除经莞龙路段和线路尾段为高架线外,其他均为地下线,地下线长度约为26.7km,占线路总长的70.6%,高架线(含地面线及过渡段)长度约为11.1km,占线路总长的29.4%。工程共设东莞火车站、茶山站、银珠街站、温南路站、东城路站、旗峰公园站、会展中心站、新城中心站、南城水濂公园站、厚街大道站、厚街汽车站、厚街展览中心站、东莞虎门站13个车站,其中银珠街站、东莞虎门站为高架站,其余均为地下车站。在东城区设车辆段1座,在新城中心站设控制中心1座,在旗峰公园站、厚街汽车站各设1座主变电所。目前该工程已经在建,预计2015年全线通车。东莞市城市快速轨道交通R2线(东莞火车站~东莞虎门站段)施工工期与外博大厦施工工期重叠,因此,不考虑R2线施工阶段对外博大厦的影响。离项目地最近的站点为厚街展览中心站,从项目地块东侧(现状省道S256)地下通过,与外博大厦最近距离为380m。除温南路站A号风亭(冷却塔)、东城路站B号风亭(冷却塔)外,其他风亭(冷却塔)对沿线声环境敏感点影响较小;风亭排放的废气影响范围集中在排放口15m范围内;R2线全线使用轨道减振器14430延米(双线)、使用高性能减振型扣件6300延米(双线)、使用浮置板式整体道床500延米(双线,可根据线路调整情况进行设置)确保沿线各敏感点二次结构噪声满足GBJ118-1988《民用建筑隔声设计规范》一级标准40dB限值要求。外博大厦与R2线相距380m,因此,R2线运营阶段,风亭(冷却塔)噪声、振动、风亭废气对外博大厦的影响极小。2、穗莞深城际轨道本报告引用《穗莞深城际轨道交通工程环境影响报告书》成果,分析穗莞深城际轨道运营期可能对项目外博大厦的不良环境影响。穗莞深城际轨道交通工程起点为广州地铁5号线鱼珠站,经广州境内庙头、广州开发区,经东莞境内麻涌、洪梅、沙田、厚街、虎门、长安等镇,经深圳境内经松岗、沙井、福永等街道,终点为深圳机场,线路全长86.62km。其中高架线路59.95km,地下线路24.67km,过度段2km。设车站16座,设车辆段1处,停车场2处。136 广东现代国际展览中心二期扩建工程环境影响报告书线路起自广州地铁5号线鱼珠站,沿港前路、黄埔东路至庙头设庙头站,与广州13号线换乘,出站后出地面高架,在广州开发区内与新沙港专用线并行,跨东江进入东莞市境内;上跨并行规划沿江高速进入麻涌镇南,沿麻涌镇规划东海路高架设麻涌站,与东莞R1线换乘;跨越倒运海水道后进入洪梅,沿洪梅大道高架,设洪梅站与莞惠城际接轨;沿洪梅大道一路向南高架,至沿江高速公路跨东江南支流桥位处与其并行过东江进入沙田;过东江后高架于口岸大道与沿江高速公路并行,在县道237高架至沙田变电站处东转沿路高架,经沙田汽车站,跨淡水湖、南北大道至厚街,沿东莞运河东侧高架,跨明珠路、进港中路后入地,沿256省道地下设虎门火车站,与广深港和东莞R2线换乘;经虎门商贸城后沿捷南路地下前行,过金宁大道后出地面高架,线路拐入振安路高架,经长安乌沙,跨越广深高速公路后设长安步行街站,与东莞R3线换乘;跨东宝河后拐入宝安大道后,沿宝安大道高架,在重庆路路口处开始入地,沿地下进入深圳机场。目前该工程已在建,预计2013年底实现通车。噪声:地下段风亭、冷却塔是地下区段的主要环控设备,其噪声影响范围为周围25m以内区域。为降低其噪声影响,工程设计在选用低噪声的风机和冷却塔的同时,在风亭风道内设置大型片式消声器,风口背向敏感点,并保持风亭、冷却塔与最近敏感点的距离为15m,可以保证其外排噪声满足地方功能区划要求。振动:运营期的振动影响主要由车轮与钢轨之间的撞击、滑动和滚动振动产生,经轨枕、道床传递至桥梁基础或隧道衬砌,再传递至地面,从而引起地面建筑物的振动,对周围环境产生影响。工程进入城市中心为地下线,主要振动源类为列车运行产生的振动,鉴于国内尚无运营的地下铁路城际线,铁路振动传播规律与隧道的结构、地质条件、列车运行速度等都有着密切联系。区间最小埋深10m,平均埋深大于15m。设计按目标速度的90%考虑,最大旅行速度取126km/h,经过车辆轴重修正后,设计振动源强选择为:隧道内运行时列车振动源强VLzmax为88.1dB。按《城市区域环境振动标准》(GB10070-88)之混合区、商业中心区标准:昼间75dB,夜间72dB衡量,铁路振动对位于线路埋深低于10m,水平距离20m以内的敏感点影响较大。随着埋深增大,水平影响范围也将减小,埋深超过20m时,水平影响范围为5m以内。按《城市区域环境振动标准》(GB10070-88)之居民、文教区标准:昼间70dB,夜间67dB衡量,铁路振动对位于线路埋深低于10m,铁路振动对水平距离45m以内的敏感点都有影响。穗莞深城际轨道从项目地块南侧地下通过,并在仁康医院南侧设厚街站(地下站),与外博大厦最近距离为570m。可见,运营期受穗莞深城际轨道噪声、振动影响较小。137 广东现代国际展览中心二期扩建工程环境影响报告书7.8.2外环境污染防治对策措施(一)汽车尾气污染防治对策措施主要有:一是增加绿化,种植吸附能力强的树种;二是与交通管理部门配合,对尾气不能达标排放的车辆给予控制,禁止其进入项目区。(二)为了减小外环境噪声对对本项目的影响,建议建设单位采用以下措施:①在项目地块四周设置组合绿化带以降低外环境废气和噪声的影响。尤其是在临家具大道一侧增加绿化,以减轻交通噪声和汽车尾气的影响。②在面向道路一侧的建筑物外一定距离的地带种植高大茂密的树种作为隔声屏障,在设计绿色隔声屏障时,优先选用高大乔木树种,如桉树、榕树等,为最大限度发挥隔声屏障的作用,可起到较好的空气过滤和隔声的效果。③在进行工程设计时,临近道路的一面应尽量减小暴露空间,对噪声敏感的用房应尽量设计在远离道路的建筑内;面向道路一侧的楼层应采用密闭性好、隔声性能好通风隔声窗以及隔声屏障,以减轻机动车噪声、尾气的影响。④机动车在项目内限速行驶,禁鸣喇叭。138 广东现代国际展览中心二期扩建工程环境影响报告书第8章生态环境影响评价及恢复措施8.1生态现状项目位于一般生态区域,区域和用地范围内无珍惜濒危动植物和野生保护物种,项目用地现状为空地,用地类型为未利用地,用地范围内植被覆盖率约30%,植被以野生灌草丛为主,用地范围内动物种类以鼠类、蟾蜍等爬行类动物为主,生物多样性一般。8.2生态影响评价8.2.1土地占用影响分析2本项目占用土地的最大影响就是直接改变了其用地属性,项目建筑占地64571m,为永久占地,项目建设完成后,项目选址区的土地利用类型由未利用地转变为会展用地。项目所占用地原为空地,地块内植被以野生灌草丛为主,植被覆盖度约30%左右,随着项目的建设,该地块由空地转为会展用地,使用价值将得到大幅度提升;项目建成后,项目绿地率约11.7%左右,虽然较现状有所降低,但项目建成后将在地块内种植乔木、灌木和草地等植物,生物多样性得到增强,另外,项目建成后地面多为硬质地面,下垫面类型的改善,对局部小气候、对降雨的缓冲能力,均产生有利的影响。8.2.2对生态系统整体影响分析项目用地范围原为空地,生态系统类型为陆域自然生态系统,项目施工将使用地范围内原有生态系统遭到破坏,施工期间,地块内生态系统功能降低,若未采取相应水土保持措施,会引发水土流失;但施工期是短暂的,随着项目的建成,项目用地范围内生态系统转变为城市人工生态系统,城市生态系统最基本的功能主要表现在生产功能、生活功能、还原功能和调节功能,这些功能通过城市系统内部与外部的物质流、能量流、信息流、人口流及货币流等得到具体体现。总的来说,项目的建设会使用地范围内生态系统组成和功能发生转变,但项目位于城市建成区,周边均为城市人工生态系统,项目的建设有利于提高区域城市生态系统的整体性。139 广东现代国际展览中心二期扩建工程环境影响报告书8.2.3植被影响分析项目地块内有一定的植被覆盖度,工程施工将破坏场地地表植被,会造成用地范围内一定的生物量损失,但不会降低项目所在区域生态系统整体功能,也不会造成区域生物多样性的降低。据统计,地球上不同生态系统的植物生物量见表8.2-1。表8.2-1地球上部分生态系统的植物生物量22生态系统平均生物量(kg/m)生态系统平均生物量(kg/m)热带雨林44农田1.1热带季雨林36疏林和灌丛6.8温带常绿林36温带草原1.6温带阔叶林30沼泽15北方针叶林20湖泊和河流0.02热带稀树干草原4.02据现场调查,项目地块内原有植被以野生灌草丛为主,面积约为27000m。参考表3.3-32相关数据,按单位面积生物量平均为1.1kg/m考虑,可粗略估计,工程永久占地造成的生物量损失约为29.7吨。项目用地范围内原有植被主要为野生灌草丛,无古树名木等受保护物种;随着项目建设的完成,项目将在地块内进行绿化,绿地率将达到11.7%,绿化植物包括草本植物、观赏花木、阔叶乔木和芳香植物等,使得用地范围内植被得到最大程度的恢复,生物量得到了补偿。8.2.4动物影响分析项目地块内无珍稀濒危物种和受保护野生动物,可能有一些鼠类、蟾蜍等爬行类动物,工程施工期会破坏项目地块原有生境,使爬行动物生活受到干扰,部分会向其它地方迁徙。8.2.5对城市生态的影响分析城市生态系统是人为改变了结构、改变了物质循环和部分改变了能量转化的、长期受人类活动影响的、以人为中心的陆地生态系统。一般而言,城市生态系统包括城市自然生态系统和城市社会生态系统两个子系统,其功能与价值不仅体现在植被、水体等方面,更与城市经济活动、社会活动紧密相联。本项目选址于高度发达的城市建成区,项目建设对城市生态的影响主要体现在居住、就业、商贸、文化、教育、治安等社会经济活动的各个方面。140 广东现代国际展览中心二期扩建工程环境影响报告书本项目的建设一方面将提高区域城市功能,提升该片区的商贸环境,另一方面,也将为广大市民提供一个功能多样、服务优质的会议展览场所,因此,本项目建设有利于优化项目区及其周边区域的城市生态结构,大大提升城市生态的舒适度,促进区域社会经济的协调发展。8.2.6水土流失评价本报告引用惠州市华禹水利水电工程勘测设计有限公司编制的《广东现代国际展览中心二期扩建工程水土保持方案报告书》成果:建设过程中扰动原地貌、损坏土地和植被面积为2225.25hm,损坏水土保持设施面积7.05hm,其中需缴纳水土保持措施补偿费的面积为237.05hm。工程建设完成后产生弃土90.24万m。工程水土流失总量为13381.55t,新增水土流失总量12980.2t。工程在建设过程中扰动地表和破坏植被,若不采取有效的防护措施,将有可能使当地的生态环境恶化,影响附近居民的生产生活,其可能造成的水土流失危害主要有以下几个方面:(1)对土地资源的破坏和影响:工程建设破坏原有地貌和地表覆盖,从而使施工区内裸地面积增加,降低土壤的抗蚀性,增大水土流失量;(2)工程建设引起土壤加速侵蚀及周边市政管网堵塞,对周边土地利用、环境保护将造成不利影响,会给工程区的植被恢复和土地整治增加工作难度。8.2.7景观影响分析8.2.7.1施工期景观影响项目在施工会造成大面积裸露地表,且部分由于结构疏松,空隙度较大,如果不采取有效的美化和拦挡措施,雨天将会产生大量污泥、荒水;晴天运输建材往来的车辆将会产生大量的扬尘,污染空气,对附近的敏感点生活、生产也有较大影响;同时,裸露的施工点形成的大型黄土斑块影响景观,与周围景观协调一致性降低,造成区域景观美感降低。但景观影响也是暂时的,随着施工期的完毕,项目用地范围绿化的完成,将会从整体上提高区域景观效果。8.2.7.2运营期景观影响141 广东现代国际展览中心二期扩建工程环境影响报告书景观可分为自然景观、经营景观和人工景观。人工景观是一种自然界原先不存在的景观,如城市景观、工程景观、旅游地风景园林景观等。本项目建设对厚街乃至东莞的城市景观都有显著的影响,本报告从以下几个方面分析其影响:1、天际轮廓线影响分析城市天际轮廓线是城市与天空相遇合的那一个界面,是城市的形象,是城市个性的浓缩,是城市繁荣的机缘。不断挑战着人类极限高度的超高层建筑构筑起了现代都市的天际轮廓线,城市制高空间成了天际轮廓线中最为显要的那一部分。在东莞厚街的会展商圈,高达230米的嘉华大酒店是目前的地标式高楼,而外博大厦的建设将刷新东莞厚街的建筑高度,成为厚街镇乃至东莞市的新地标。外博大厦建筑本身非常具有现代超高层建筑气息,是珠江三角洲地区家具及机械、材料、配件的大型集散基地,该区域高层建筑较少,东北面有嘉华大酒店高层建筑,高度在200米左右,2个超高层建筑遥相呼应,形成东莞厚街城市景观的新天际轮廓线。对厚街镇原有城市的空间形态、环境格局、景观品质等将产生重大影响。该项目的建设将为选址区域打造成以展览中心为核心的国际商贸区奠定基础。城市的天际轮廓线有实、虚之分,实的天际线即是建筑物的轮廓,虚的天际线是建筑物顶部之间连接的光滑曲线,高层建筑在城市天际线创造中起着重要的作用,因城市的天际轮廓线从很远的地方就可以看见,也是一座城市给人的第一印象。同时,高层建筑对城市局部或部分产生的影响是在市内比较开阔的地方,如广场、干道、开放的水系和绿地所看到的天际线。因此,城市天际轮廓线不仅影响人从城市外围所看到的景观,也直接影响到市内居民的生活与视觉观赏。与其它艺术门类一样,天际线中的组成元素也应遵循基本的美学规律,避免等高、等距的机械排列而造成的轮廓的单调、呆板,理想的韵律感应为“虚—实—虚—实”的变换。“实”指建筑物等实体元素,“虚”指实体元素间的空隙。“实”有高低宽窄的变化,“虚”有广狭长短的区分。“实”“虚”以及二者组合的有序变化赋与城市天际线以韵律和节奏的变化,成为生动的乐章,产生强烈的艺术效果。天际线的节奏有规则和不规则两种,规则的节奏是由相同或相关的间隔和实体重复出现产生。不规则的节奏则是通过重复不同的、多样的符号产生,相比来说,后者更为丰富和生动,同时也给单体创作留有更大的余地,通过韵律和节奏的组合,较为平淡的建筑也能形成特征明确的天际线形象。2、城市景观设计分析142 广东现代国际展览中心二期扩建工程环境影响报告书项目在规划设计中注重景观设计,综合考虑了与周围环境的协调性,广东现代国际展览中心二期扩建工程由展览馆、外博大厦横向伸展的裙房与超高层办公楼组合的手法,跟周边多样性的建筑群相互呼应。本项目的建设使城市空间意象与建筑本身达到协调统一。具体表现在设计上,有以下特点:1)外博大厦的设计力求建筑形象达到“标志性”的效果,以东莞市花“白玉兰”为设计意象,顶部运用现代建筑的设计语言以花瓣的形态层层叠叠,形成盛开之势绽放于480米高的“莞城”上空,标志性建筑所特有的综合美感和现代感应运而生,高耸的塔楼象征着东莞以及作为整体的中国的城市有着无限的发展前景。2)A、B区展览馆外部以动感的横向线条呼应,内部通过蜿蜒秀美的连廊将南北两个区有机地组织起来,整体简洁大气,为观展者提供一个宏大而又舒适的展览空间。3)建筑造型充分考虑与周边建筑的关系,突出未来中心区建成后在楼群中展现的城市环境特征、建筑的各个方向与不同的城市环境对话,因而产生各不相同的表现方案。结果从地块周围不同道路上都可发现大厦呈现有个性、有变化的鲜明形象。4)建筑外立面拟采用包围式结构,采用透明玻璃和太阳能面板相结合的幕墙。经包围的墙面使人们在某个角度能够欣赏到窗外的景色,窗户采用平角设计,太阳光线通过玻璃反射到太阳能面板上,提高了太阳能面板的能效,太阳能面板将可帮助大厦减少超过60%的建筑能源消耗。5)本项目建筑外观色调以银灰为基调,建筑设计简洁、大器,与周围的建筑色调较为协调,不会造成较大的视觉冲击。6)本项目景观设计主要以硬质铺地为主,满足大规模人流的疏散要求,在展馆周边设置绿化隔离带,在展馆天面局部设置绿化屋面,形成多层次的绿化环境空间,提升展览馆的空间品质。因而,从总体上讲,本项目与所在区域的景观要求是相符的,能够有助于突显本区的景观特征。本项目的外观效果见附图2.1-5。从图中可以看出,本项目建筑非常具有现代超高层建筑气息,不仅不会对区域景观造成负面影响,而且会对厚街会展商务区的景观效果具有强化作用。8.3生态恢复措施8.3.1绿化措施143 广东现代国际展览中心二期扩建工程环境影响报告书绿化是项目景观的重要组成部分。项目在绿化景观设计中,体现了以下原则:(1)有效提高绿化量,增强绿化的生态性。在扩大绿地面积、提高绿地覆盖率的同时,提高绿化的生态效率。(2)绿化与环境结合,提倡景观自然化。(3)增加绿化的亲和性,实现场所的人性化。项目建筑物周围空地均布置有绿化,总的看来,项目区内除硬质地面外,均为绿化覆盖;但项目区总体绿地率低于20%,因此,项目区应进一步提高绿地率,确保不低于20%。8.3.2水土保持措施根据惠州市华禹水利水电工程勘测设计有限公司编制的《广东现代国际展览中心二期扩建工程水土保持方案报告书》,对本项目引起的水土流失做出以下防治措施:(1)展览馆水土流失防治措施地下室建设期①基坑施工区临时措施:本项目展览馆A区内基坑已施工结束,展览馆区主体工程已设计在基坑顶部及底部布设Ⅰ型排水沟及沉淀池。本项目设计在展览馆B区及C区的基坑施工区沿排水沟每隔100m布设Ⅱ型沉沙池,在排水沟出口布设Ⅰ型沉沙池,将场区内的排水沉淀后再排入市政雨水管网。②平地区地下室建设期平地区现状均为硬化,无水土流失。临时措施:主体工程在施工出口布设了洗车池1座,对进入车辆车轮进行清洗,避免车轮携带泥沙进入市政道路。③施工生产生活区临时措施:主体工程已布设排水设施,其地面均已硬化。④临时堆土区临时措施:现状已堆置临时堆土。本项目在其西侧及南侧布设土袋拦挡,防治堆土落入现状沟渠,土袋拦挡长560m。在临时堆土区东侧及南侧布设Ⅱ型排水沟,长472m。预备塑2料薄膜10000m。144 广东现代国际展览中心二期扩建工程环境影响报告书地上建筑物建设期①建筑物区本阶段地下室建设工程已经完工,地上建筑物开始施工。本阶段建筑区均已硬化,无明显水土流失。②道路管线及硬地区临时措施:在广场施工区域周围布设515m长的Ⅲ型排水,Ⅰ型沉沙池1座,Ⅱ型沉沙池2座。③绿化景观区临时措施:考虑整个项目处于雨季施工,为了避免边坡为支护前被雨水冲刷造成水土流失,因此在雨天应预备一些塑料薄膜对裸露地面进行临时覆盖。④施工生活生产区本阶段沿用地下室建设期的临时水土保持措施。⑤临时堆土区植物措施:临时堆土区堆置的部分土方用于外博大厦后期回填及覆土,且外博大厦施工2期为4.5年,因此,临时堆土区应进行撒播草籽绿化,面积为7.05hm。(2)展览馆水土流失防治措施地下室建设期①基坑施工区临时措施:主体工程设计了在基坑底部坡脚处及基坑顶部外侧1.5m处布设了Ⅱ型排水沟。本项目设计沿排水沟每隔100m布设Ⅱ型沉沙池,在排水出口布设Ⅰ型沉沙池,将本区的汇水沉淀后再排入市政雨水管网。②平地区地下室建设期平地区现状均为硬化,无水土流失。临时措施:在施工出口布设了洗车池1座,对进入车辆车轮进行清洗,避免车轮携带泥沙进入市政道路。③施工生产生活区临时措施:主体工程已布设排水设施,其地面均已硬化。④临时堆土区临时措施:本阶段沿用展览馆建设期的临时水土保持措施。145 广东现代国际展览中心二期扩建工程环境影响报告书地上建筑物建设期①建筑物区、道路管线及硬地区本阶段地下室建设工程已经完工,地上建筑物开始施工。本阶段建筑区均已硬化,无明显水土流失。②绿化景观区临时措施:考虑整个项目处于雨季施工,为了避免边坡未支护前被雨水冲刷造成水土流失,因此在雨天预备一些塑料薄膜对裸露地面进行临时覆盖。③施工生活生产区、临时堆土区本阶段沿用展览馆建设期的临时水土保持措施。2植物措施:施工结束后平整场地,撒播草籽绿化,面积为7.05hm。(3)临时堆土的水土流失防治措施本项目开挖面积较大,产生的弃土比较多,弃土基本上是边开挖边运走,但是由于项目本身需要一定的回填土,可能在现场会设置一定的临时堆土场,项目应尽量避开雨季进行开挖,并对临时堆土场采取必要的覆盖措施,尤其是在雨季,必须采取专门的覆盖拦挡措施,如采用塑料薄膜对堆土进行覆盖,避免大面积的水土流失。146 广东现代国际展览中心二期扩建工程环境影响报告书第9章污染防治措施经济技术经济可行性分析9.1污水防治措施分析9.1.1污水的组成项目所排污水主要为生活污水,具有城市污水的特征。9.1.2污水去向和污水处理措施项目位于东莞市厚街镇家具大道南侧,属于东莞市厚街沙塘污水处理厂的集水范围,详见附图7.1-1,周边市政管网完善。建设项目生活污水经三级化粪池预处理达到污水处理厂的纳污标准,即广东省地方标准《水污染物排放限值》(DB44/26-2001)第二时段三级标准后排放到市政污水管网,进入东莞市厚街沙塘污水处理厂集中统一处理达标后,排入东莞运河。一般生活污水→三级厌氧化粪池→市政管网3项目外排综合污水约1447.1m/d。9.1.3污水处理方案论证项目属东莞市厚街沙塘污水处理厂纳污范围。东莞市厚街沙塘污水处理厂选址位于厚街沙塘村西南,用地面积269.8亩,由厚街海清污水处理有限公司负责投资建设、营运,主体工程采用BOT模式建设,项目总投资12711万元。总规模为日处理污水25万吨,分三期建3设。其中近期工程为日处理污水10万m/d,投资总额1.14亿元,工程费用9547万,已建33设完成并投入使用;中期规模15万m/d,远期规模25万m/d。采用具备脱氮除磷功能的改良SBR工艺,具有流程短,自动化控制水平高,抗冲击负荷能力强,出水水质好等特点。污水经处理后,达到《城镇污水处理厂污染物排放标准》(GB18918-2002)中的一级B标准后排放。厚街沙塘污水处理厂纳污范围为厚街镇保桥路一桥南路-创业路以南40多平方公里地区。目前项目周边管网已建好,即项目营运后污废水可排入东莞市厚街沙塘污水处理厂处理。根据东莞市现有同类型住宅生活小区生活污水的类比监测结果,及类比调查分析城市污水经东莞市厚街沙塘污水处理厂处理后的出水水质如下表9.1-1。147 广东现代国际展览中心二期扩建工程环境影响报告书表9.1-1东莞市厚街沙塘污水处理厂出水水质项目CODcrBOD5SSNH3-N《城镇污水处理厂污染物排放标6020208准》(GB18918-2002)处理后水质<60<20<20<8由上表可看出,污水经东莞市厚街沙塘污水处理厂处理后的出水水质达到于《城镇污水处理厂污染物排放标准》(GB18918-2002)一级B标准后,排入东莞运河后,不会对纳污水体产生不良影响,其技术是成熟可行的。另外,本项目采取的各类防渗措施得当,各类污水输送管道的密闭性良好,可以确保项目运营期项目各类污水不会下渗影响地下水质,本项目对地下水环境影响甚微。9.22大气防治措施分析9.2.1废气的组成项目竣工投入使用后,其废气污染源主要有:机动车尾气、发电机尾气、垃圾站臭气等。9.2.2废气治理措施◆机动车尾气项目设有地下停车场,地下停车场设有抽风排气系统,保证地下车库的换气次数,并收集车库废气由绿地中间排出,机动车尾气不会在车库累积,减少汽车尾气对区域环境空气的污染。◆备用发电机尾气影响项目备用发电机燃油尾气通过适当的水喷淋(添加碱液)等处理后由专用排气筒高空排放,其排气筒高度高出所在楼顶5m,对本项目内外环境的影响很小。由于发电机仅在应急停电条件下使用,而现今东莞市的供电能力较为充足,发电机的使用机会较小,因此,若对发电机组尾气进行治理后达标排放,该污染源对人员的影响将很小。◆垃圾站臭气影响为防治垃圾收集站臭气污染,本报告提出以下防治对策:(1)垃圾分类收集,办公废纸、水瓶等可回收利用的,应集中收集后出售回收利用,项目垃圾站堆放的主要为不腐烂的生活垃圾、商业垃圾,密闭袋装运至项目垃圾收集站。(2)保证垃圾收集站内及周边环境整洁,每天定时对垃圾收集站地面进行冲洗。148 广东现代国际展览中心二期扩建工程环境影响报告书(3)恶臭气体的净化方法有很多,如物理脱臭法、生物除臭、化学吸收、电离、植物液雾化等等。本项目可选择生物除臭法,即利用微生物的氧化能力使恶臭物质氧化分解,从而达到除臭的目的。(4)垃圾房应设置独立的通风设施,在垃圾房周边增加绿化,排放口应朝向绿地,不得指向仁康医院等环境敏感点。本报告认为项目拟采取的大气污染防治措施在技术上是可行的。9.3噪声防治对策分析项目的主要噪声源有:备用发电机、风机房、水泵房、机动车等。(1)项目内部行驶机动车对于项目内行驶的各类机动车产生的噪声采取以下措施:①在用地范围内尽可能增大绿地面积,搞好植树绿化,利用树木的散射、吸声作用以及地面的吸声,达到降噪的目的.②项目区内设置禁鸣、限速示牌、限制通过区内道路机动车的车速、禁止机动车使用喇叭。(2)配电房建议项目对低频噪声配电房变压器采取以下降噪措施:①将变压器置于专用配电房内,将机房封闭且采取良好的隔声措施;②在配电房变压器机组与基础之间设置减振缓冲装置;③将变电器所有刚性结构连接处改为弹性连接,减少振动和共振。低频噪声配电房变压器在经本环评建议治理后,则不会对项目内部环境造成不良的影响。(3)水泵房、风机水泵及风机安装在地下室的专用机房内,设置减振基础,并对机房密闭处理后,再经墙体的隔声作用,边界噪声达到《社会生活环境噪声排放标准》(GBl2348-2008)2类标准,对周围环境不会产生不良影响。(4)备用发电机应急发电机房(柴油发电机)采取屏蔽、减振、隔音等措施,减少噪声强度。对风机等产生的气流噪声,采用消声器降低噪声。具体措施如下:①隔声:隔声墙、隔声门;149 广东现代国际展览中心二期扩建工程环境影响报告书②吸声:吸声天花、吸声墙体;③在发电机尾气管安装与机组配套的阻抗结合式一次消声器。发电机尾气经不锈钢波纹膨胀节减震后,由排烟管道进入一次消声器,经过一次消声器的尾气进入尾气净化装置。④发电机组进风消声采用自然进风消声道的方式。设置室式排风消声道,排风道与机组利用软接头连接,以防声桥传声降低消声效果。⑤在风机进出口气管道上安装消声器。(5)冷却水塔①按照国家《环境保护产品技术要求低噪声型冷却塔》(HJ/T385-2007)的要求,选用低噪音冷却塔。②在冷却塔的风机排风口安装消音管,并在冷却塔底部安装隔音垫。③根据预测结果可知,本项目展览馆A区设置的冷却塔在西边的边界处的噪声排放量较大,超过标准值,因此,本项目应对展览馆A区设置的冷却塔应设置隔声屏障,要求隔声效果达到8分贝以上,以降低项目噪声在边界处与现状噪声的叠加效果。隔声屏的位置应在冷却塔的外围距离冷却塔的边缘5m以内,高度应比冷却塔高出1m,建议把整个冷却塔区域围合起来进行设计,其周长大约为135m。建议的冷却塔降噪措施见图9.3-1。150 广东现代国际展览中心二期扩建工程环境影响报告书有衬通风口风帽水冷却塔减振垫减振垫裙房图9.3-1冷却塔降噪措施综上可知,该项目的防治噪声措施在技术上是可行的。9.4固体废弃物防治措施分析在项目区域内设置分类垃圾回收箱对生活垃圾进行分类回收,分别对废纸、废电池、玻璃、废旧金属等进行回收,并制定相应的管理措施:①建立完善的管理制度,明确责任,定时清扫,定时收集;②垃圾实现袋装化,采用易降解的垃圾袋;③规划好合理的垃圾收集和运输路线,采取防护措施尽量减少运输途中的垃圾散落;④每天至少定期运送垃圾一次;⑤废电池、废油漆等危险废物要单独收集,交有资质的单位处理。综上所述,该项目的固体废弃物防治措施是合理、有效的,在技术上是可行的。9.5光污染预防措施分析(1)玻璃幕墙光污染预防措施根据《玻璃幕墙工程技术规范》(JGJ102-2003)中规定,为限制玻璃幕墙光污染,本项目外立面玻璃幕墙应采用反射比不大于0.30的玻璃,宜选用柔和中性的色彩。本项目各建筑物20m高度以下的玻璃幕墙应该用反射率小于12%的低反射玻璃。并根据各种玻璃幕墙的使用寿命,定期进行检验,及时返修或更换。不锈钢及铝合金饰面材料选购时,也应注意151 广东现代国际展览中心二期扩建工程环境影响报告书选择反射率低的材料。在设计时考虑反射角度尽量减少对周边住户与办公楼以及周边道路的光污染。在建筑物高度10m~30m以下位置,应根据实际情况不使用玻璃幕墙。(2)灯光污染预防措施①控制本项目环境照明和装饰性灯具光线的出射方向,使之不能直接照射到居民住宅的窗户上。②在设计本项目室外照明时,充分考虑灯具的安装位置,尽量避免将灯具安装在居民住宅一侧。③在满足照明要求的前提下,减小灯具功率。④采取照明控制手段,在不需要照明的时候将照明设备关闭。控制环境照明和景观照明的时间,尽可能的缩短夜间照明时间。⑤使用对周围动植物影响最小的光源。如对昆虫吸引力最大的是荧光高压汞灯,较小的是低压钠灯和高压钠灯。所以在有居民和游客逗留的城市休闲区的照明设计中也应尽量避免使用荧光高压汞灯,以免引来不受人欢迎的昆虫。综上所述,该项目预防光污染的措施是合理、有效的,在技术上是可行的。9.6高楼风的防治措施与建议(1)重视项目裙楼、种植高大乔木以及围墙拱廊等遮挡物对高速气流的剥离作用。户外广告牌、玻璃幕墙和建筑物外装饰等应委托专业的有资质的单位按照国家规范施工建设,确保在台风等强风状态下的安全。(2)地下停车场排风口、备用发电机的废气排放口不要设在超高层建筑的背后涡流区内,以防大气污染物不易扩散而造成大气污染物超标。综上所述,该项目防治高楼风的措施是合理、有效的,在技术上是可行的。9.7其他措施与建议(1)根据项目特点确定合理的绿化方案,综合运用各种绿化方式和风景园林艺术手法,充分利用自然条件,精心组织景观序列。(2)绿化地段应避免物种单一化,选择适合当地环境的树种。建立观赏型、环境保护型、保健型的多种人工植物群落,尽量做到有疏有密、多层次化,同时充分利用有限的绿色空间,增加绿色的厚度和气氛,给人们带来明显的环境效益和社会效益。152 广东现代国际展览中心二期扩建工程环境影响报告书(3)充分利用有限空间。绿化形式应重点考虑立体绿化,增加绿化层次结构。(4)对于项目建设造成的区域交通堵塞问题,需要由市规划管理部门应统筹规划,统一解决。(5)本项目建筑物的高层与底层玻璃幕墙均应安装屏蔽防雷设施。153 广东现代国际展览中心二期扩建工程环境影响报告书第10章总量控制和清洁生产10.1污染物总量控制分析10.1.1总量控制分析的原则、目的与意义总量控制是指以控制一定时段内一定区域中“排污单位”排放污染物的总重量为核心的环境管理方法体系。对于总量控制,国内一般将其分为容量总量控制、目标总量控制和行业总量控制三种类型,具体又可分为国家总量控制计划、省级总量控制计划、城市总量控制计划和企业总量控制计划等。从规划和技术层次上又可分为大气污染物排放总量控制和水污染物排放总量控制。污染物排放总量控制已成为中国环境保护的一项重要举措,实施污染物排放总量控制,将有利于对区域污染综合防治进行总体优化,有利于推动区域污染源合理布局,从而有计划、有目标地控制环境污染。总量控制注重环境质量与排放量之间的科学关系,个别污染源的削减与环境质量的关系,因此总量控制的最终目的是实现项目所在区域的环境保护目标。总量控制分析应以当地环境容量为基础,以新增加的污染物排放量不影响当地环境保护目标的实现、不对周围地区环境造成有害影响为原则。《建设项目环境保护条例》第三条明确规定:建设产生污染的建设项目,必须遵守污染物排放国家标准和地方标准;在实施重点污染物排放总量控制的区域内,还必须符合重点污染物排放总量控制的要求。进行环境影响评价的主要目的是针对影响环境变化的项目,确保环境保护预防性措施的统一性,在影响环境变化的项目实施前,充分调查、描述和评价其对环境的影响。环境影响评价是实现建设项目污染物排放总量控制的有效措施,是贯彻“预防为主”方针和控制新污染的一项重要制度。而将总量控制分析纳入环境影响评价中,将使对单个污染项目的评价和管理转变为对功能区和整个城市或区域环境质量的评价和管理,将使环境管理思想从点源微观管理向区域宏观管理进行转变,从而使环境影响评价制度在环境管理中发挥更大的作用。对建设项目污染物排放实施总量控制,不仅有利于建设单位的污染控制,也有利于当地环境主管部门的监督管理。本环评结合“一控双达标”的原则和要求、建设项目的排污特点以及建设项目所处位置的环境现状,提出本项目主要污染物的总量控制指标。154 广东现代国际展览中心二期扩建工程环境影响报告书10.1.2项目主要污染物排放总量控制指标建议本项目所产生的污染物列入国家、广东总量控制的污染物指标有5项,即:CODcr、氨氮、二氧化硫、NOX、可吸入颗粒物。其中,由于本项目备用发电机属于不常用设备,而且不一定使用,故不把其污染物列入总量控制指标内,本评价大气指标仅考虑车库尾气中NOX的排放量。如工程分析所述,本项目建成后主要污染物排放总量指标如表10.1-1所示。由于本项目各类废水最终均排入东莞市厚街沙塘污水处理厂,因此,本项目废水及CODcr、氨氮无需向环保部门申请排放总量控制指标;由于NOX排放量较小,可由环保审批部门直接审批。表10.1-1项目污染物排放总量主要污染物排放总量(吨/年)废水量520805.3预处理后CODcr177.1预处理后氨氮12.7污水厂处理后CODcr31.2污水厂处理后氨氮4.2NOX0.75110.1.3区域削减分析尽管项目产生的废水已达标排放,但纳污水体水质超过了III类标准,为了更好的保护水环境,通过区域削减等手段解决项目纳污水体水环境污染问题,目前与东莞运河水环境治理有关的措施有如下:进入东莞运河的水污染源部分来自河流两岸镇村、居民排放的生活污水,目前,厚街沙塘污水处理厂已建成运行,沿线生活污水经简单预处理后进入沙塘污水处理厂处理后达标排放至东莞运河,减轻了纳污水体水污染负荷。根据东莞市污水处理工程建设有关规划,东莞市厚街沙塘污水处理厂选址位于厚街沙塘村西南,用地面积269.8亩,由厚街海清污水处理有限公司负责投资建设、营运,主体工程采用BOT模式建设,总投资12711万元。总规模3为日处理污水25万吨,分三期建设。其中近期工程为日处理污水10万m/d,投资总额1.143亿元,工程费用9547万,已建设完成并投入使用;中期规模15万m/d,远期规模25万3m/d。采用具备脱氮除磷功能的改良SBR工艺,具有流程短,自动化控制水平高,抗冲击负荷能力强,出水水质好等特点。污水经处理后,达到《城镇污水处理厂污染物排放标准》(GB18918-2002)中的一级B标准后排放。厚街沙塘污水处理厂纳污范围为厚街镇保桥路155 广东现代国际展览中心二期扩建工程环境影响报告书一桥南路-创业路以南40多平方公里地区。污水处理工程可有效削减进入东莞运河的水污染物,对河道水环境保护起着重要作用。由于本项目与一期、二期工程相对独立,其污染物的产生和排放均各自进行,本次的二期扩建不存在对原有的污染进行削减或者改善的问题,因此,本评价不再对扩建前后的污染进行三本帐分析。10.2清洁生产广东现代国际展览中心二期扩建项目在总体规划中,把环境保护、清洁生产的环境概念引入到设计理念中,强调人与自然的和谐统一。设计中通过采用环保型的建筑及装饰材料,通过采取一系列的节能措施,减少了能源的消耗,降低了污染物的产生和排放量,从而更好的保护了环境。10.2.1建筑及装饰材料的选用项目是由建筑材料和装饰材料所围成的与外环境隔开的微小环境,这些材料的某些成分对室内环境质量有很大影响。例如,有些石材和砖中含有高本底的镭,镭可蜕变成为有放射性的氡,能引发肺癌。很多有机合成材料可向室内空气中释放许多挥发性的有机物。例如,甲醛、苯、甲苯、醛类、酯类等污染室内空气,有关人员已在室内空气中检测出了500多种化学物质,其中有20多种有致癌或致变作用。这些物质的浓度有时虽不是很高,但在它们的长期综合作用下,可使在这些挥发性有机污染环境内的人群出现不良建筑综合症,建筑物相关疾病。尤其是在装有空调系统的建筑物内,由于室内污染物得不到及时清除,就更容易使人出现这些不良反应及疾病。建筑及装饰材料对住宅环境的影响见表10.2-1。表10.2-1建筑及装饰材料对环境影响原材料名称产品可能产生的污染物危害砖、石材、玻璃、水泥等放射性元素诱发癌变等合成板材、人造板材甲醛、氯乙烯、苯、甲苯、醛类同上甲醛、氯乙烯、苯、二甲苯、螨壁纸、地毯同上虫等苯、二甲苯、丙酮、已酮、甲酸引起人眩晕、头痛、恶心等,涂料等对眼、鼻有刺激性作用156 广东现代国际展览中心二期扩建工程环境影响报告书通过以上分析可以看出,建筑及装饰材料的选用,直接影响到住宅环境和住户的身体健康。近年来,材料生产厂家也越来越重视绿色材料的开发,如水性涂料、放射性元素满足标准要求的石材、玻璃等。因此,建设单位应优先选用无污染或轻污染的材料,如环保涂料、绿色建材。10.2.2项目建筑节能评价10.2.2.1节能要求根据节能规范,东莞位于夏热冬暖的地区。故此,建筑的围护结构(屋面的外墙)热工设计必须符合表10.2-2中的设计标准。表10.2-2夏热冬暖地区围护结构限值和遮阳系数限值代表性体型系数≤0.30.3<体型系数≤0.4围护结构部位22城市传热系数W/(m·K)传热系数W/(m·K)福州屋面:普通屋面≤1.0≤0.90莆田钢、木等轻型结构屋面≤0.8≤0.70龙岩外墙:普通外墙≤1.2≤1.1梅州钢、木等轻型结构外墙≤0.90≤0.80兴宁玻璃的遮阳系数SC玻璃的遮阳系数传热系数K传热系数K英德(所有其它方向/北SC(所有其它方向/22W/(m·K)W/(m·K)河池向)北向)柳州窗墙面积比≤10%≤4.7-≤4.7-贺州10%<窗墙面积比≤4.7≤0.60/-≤4.7≤0.60/-泉州≤20%厦门窗20%<窗墙面积比≤3.5≤0.60/-≤3.5≤0.50/-广州≤30%深圳30%<窗墙面积比≤3.5≤0.50/0.60≤3.5≤0.45/0.60湛江≤45%汕头玻璃的遮阳系数SC2幕墙传热系数W/(m·K)海口(所有其它方向/北向)南宁玻璃幕墙≤3.5北海≤0.35/0.45不透明幕墙≤0.7梧州10.2.2.2项目已采取的节能措施项目为非高能耗的建设项目,总体用能数量不大。但建设节约型社会,是缓解我国资源供需矛盾的根本出路,也是贯彻科学发展观、加快增长方式转变的必然要求,―十一五‖规划更是把单位GDP能耗降低20%左右作为约束性指标;东莞市也提出了在此期间节能达50%157 广东现代国际展览中心二期扩建工程环境影响报告书的较高目标(与上世纪八十年代未采取节能措施的建筑相比)。同时面临国际能源价格上涨和环境恶化的压力,节约能耗具有重要的现实意义,该项目节能主要从以下方面考虑:1、建筑单体节能设计(1)围护结构的节能设计围护结构利用新型节能型建筑材料。墙体砌块采用空心砖等隔热材料,屋顶用加气混凝土等方式隔热,日照面墙体外部色彩为浅色。门、窗做好节能材料的选用及设计,施工时严格要求其密闭性合格。(2)电力节能设计①根据负荷容量,供电距离及分布,用电设备特点等,合理设计供配电系统和选择供电电压,最大限度的减少线路损耗。变电所及电气竖井位置靠近负荷中心,缩短配电半径,减少线路损耗。同一电压供电系统配电级数不多于三级,并按热稳定要求结合经济电流密度合理选择导线截面。②选用低损耗、低噪音的节能高效设备。如变压器选用SCB10型高效节能变压器等。采用无功功率动态补偿及抑制谐波装置,提高功率因数,减少无功损耗。③按《建筑照明设计规范》GB50034—2004严格控制照明功率密度值。照明灯具以节能灯及T5型荧光灯及电子镇流器为主,光效高,功率因数高,节约能源消耗。照明以高效节能型灯具为,主格栅的反射体及表面选用难燃材料,灯具效率不低于65%。荧光灯管或灯盘均须装电子镇流器使功率因数达到0.9以上。光源灯具选择及控制如下:表10.2-3项目光源灯具的选择及控制方法区域光源灯具选择及安装控制方法办公及公共走亮度与时间、智能开关与调光控制相结合T5荧光灯或节能灯筒灯廊(拟采用DALI系统)疏散楼梯吸顶式节能灯红外线感应开关控制(应急时强制亮灯)车库吊式安装的防护式T5单管荧光灯智能控制/手动控制机电设备房挂墙式或吸顶安装的T5荧光灯就地自动控制光敏开关,时间控制器及手动控制,可在室外变配电值班室内统一控制④智能照明控制系统158 广东现代国际展览中心二期扩建工程环境影响报告书分布式智能照明控制系统主要用于对照明灯光系统的控制,通过开关模块、调光模块等可对日光灯、节能灯、石英灯等多种光源开停及调光,对各种场合的灯光进行控制,满足各种环境对照明的要求。⑤配合泛光及LED景观照明,对其实行智能照明控制。⑥配合建筑构思,在允许的情况下采用太阳能光伏发电技术,节约能源。(3)太阳能草坪灯太阳能在建筑上具有很大的节能利用的潜力,世界各国通常把太阳能的利用,作为建筑节能的有效手段。利用太阳能可以减少空调和照明所使用的常规能源。在减少二氧化碳排放量、保护环境的同时,能够满足现在生活要求,供给人类舒适生活的条件。东莞处于低纬度地区,―夏至‖昼长约13小时,“冬至”昼长约10小时,白昼长短的季节差异不大。年平均日照时数1967.2小时,日照百分率45%。年中日照最少的时间为2~4月份,月平均日照时数为97~104小时,最多的是7月份,平均达230.4小时,具有发展、利用太阳能的潜力和优势。太阳能草坪灯是新型的绿色能源产品,节能、环保、安全、美观。它采用进口高性能晶体硅太阳能电池组件,白天将太阳光能转换为电能储存于蓄电池,晚间则自动发光照明。灯管采用超高亮LED,比一般草坪灯耐用200倍,使用寿命长达10万小时。项目绿地面积为18258平方米,有较大的操作空间,建议项目采用太阳能草坪灯。2、行为节能(1)开展节能教育①对物业管理人员的培训,强化设备节能组织物业管理人员参加节能培训,未经节能教育、培训的人员,不得在耗能设备操作岗位上工作。②对办公人员、参展人员开展节能教育,养成节能的良好习惯由进驻企业组织办公人员、参展人员参加节能培训,从日常生活入手,养成节能用电的良好习惯。③加强节能宣传,提高办公人员、参展人员节能意识由物业管理公司负责此项工作。利用横幅、传单或手册等灵活多样的形式,加强节约用电的宣传,努力提高办公人员、参展人员的节能意识。(2)加强用电分析计量管理159 广东现代国际展览中心二期扩建工程环境影响报告书加强能源计量管理,建立健全能源消费统计和能源利用状况分析制度。通过节能知识和宣传与培训,办公人员、参展人员树立起牢固的节能意识。力争行为节能达10%以上。3、小结该项目将严格执行《民用建筑节能条例》法律法规及相关规范,做好技术节能工作,在做好建筑围护结构、制冷通风、供电供水系统等节能挖潜工作的基础上,做好太阳能等可再生能源的项目适应性调研工作,做到节能工程与建筑主体工程同步设计、同步施工、同步验收,达到与同类建筑(上世纪八十年代未采取节能措施时的建筑)节能50%以上的目标,并力争把该项目打造成建筑节能示范工程。10.2.2.3本环评建议的建筑节能措施为最大限度的节约能源,本环评建议增加如下建筑节能措施:1、建筑每个朝向的窗(包括透明幕墙)墙面积比不大于0.7,窗(包括透明幕墙)墙面积比小于0.4时,玻璃(或其他透明材料)的可见透射比不小于0.4。外窗(包括透明幕墙)2采用有遮阳效果的8mm+12A+8mmLow-e中空白色玻璃,玻璃传热K不大于4.0W/(m.K),玻璃的遮阳系数SC不大于0.5,玻璃的可见光透射比不小于0.4。不设有透明屋顶部分。2、外窗的可开启面积不小于窗面积的42.14%,透明幕墙具有可开启部分或设有通风换气装置。3、外窗的气密性不低于《建筑外窗气密、水密、抗风压性能分级及检测方法》(GB/T7016-2008)规定的4级;透明幕墙的气密性不低于《建筑外窗气密、水密、抗风压性能分级及检测方法》(GB/T7016-2008)规定的3级。4、外墙采用蒸压加气砼,屋面采用保温性能好的挤塑聚苯乙烯泡沫塑料板,厚度25。5、室内采用节能型照明用具、燃气用具等设施。通过采取上述节能措施,能有效的减少能源的浪费,从而产生间接的经济、社会和环境效益。10.2.3节水措施1、充分利用市政给水压力,在市政给水压力范围内的用水点采用市政压力直供,地下一层采用市政压力供水。160 广东现代国际展览中心二期扩建工程环境影响报告书2、采用节水卫生间设备,包括单/双冲水大便器,自动感应中水小便器,红外感应水嘴等,并合理配置水表等计量装置。公共场所洗手盆采用充气式感应龙头;控制卫生器具配水点压力不超过0.35Mpa;3、水池、水箱溢流水位均设报警装置,防止进水管阀门故障时,水池、水箱长时间溢流排水。4、所有的热水系统供水干管应尽量靠近出水口;对热水管进行保温处理以节约水和能量的消耗。5、安装虹吸屋面排水系统,将水引入储水池以再利用。6、景观区域绿化用水采用微喷滴灌方式浇洒,并设置单独用水计量装置。10.2.4施工过程清洁生产建设单位对清洁生产较为重视,在施工期从水、气、声、固废等四方面作出如下控制措施确保项目在施工建设期间做到清洁生产。1、水污染控制施工期施工工人生活污水不外排,经过预处理后排入市政管网,预处理工艺如下:生活污水→格栅隔渣→三级化粪池→市政管网;2、环境空气污染控制1)在项目施工场地建设简易仓库,临时贮存粉状建筑材料;2)施工场地定期洒水,以防止浮尘产生,在大风日加大洒水量及洒水次数;3)施工场地内运输道路及时清扫,以减少汽车行驶扬尘产生;4)运输车辆进入施工场地应低速行驶,减少扬尘产生量;5)如需灰渣、水泥等,运输时应采用密闭式槽车运输;6)所有往来施工场地的多尘物料应用帆布覆盖。通过以上措施,严格控制污染物的排放,减少对环境和人体健康的危害。3、声环境污染控制1)对噪声较大的施工设备,采取消声隔声措施,例如可将其置于临时工作棚内;2)对个别声级较大的设备,在靠近声敏感点一方设置声屏障;3)将施工机械的作业时间严格限制在七时至十二时,十四时至二十时。原则上禁止夜间施工,严禁高噪声设备在休息时间(中午或夜间)作业。如施工期因工艺要求必须连夜作业161 广东现代国际展览中心二期扩建工程环境影响报告书时应得到有关部门批准,并公告附近居民。否则,不得违反“施工机械的作业时间严格限制在七时至十二时,十四时至二十时”的规定。4、固体废弃物污染控制1)开挖地基时,建设挡土墙,避免所挖掘的土方因降雨径流流失;2)施工过程产生的建筑垃圾及多余的土石方及时清运出施工现场,所有建筑垃圾均运至东莞市环卫部门指定的地点安全处置,不随意倾倒及堆放;3)施工人员产生的生活垃圾,建设临时收集装置,并交由环卫部门统一清运至东莞市垃圾处理场处理,不随意乱丢弃。10.2.5结论综上所述,本项目在总体规划设计中,通过合理采用建筑及装饰材料,并采取一系列的节能措施,将会营造一个良好的生活环境,减少能源的消耗,降低污染物的产生和排放量,更好的保护了环境。在项目建设施工过程中从水、气、声、固废等四方面采取一系列控制措施确保项目在施工建设期间做到清洁生产。因此,该项目的建设符合清洁生产的要求。162 广东现代国际展览中心二期扩建工程环境影响报告书第11章环境风险分析本报告所提到的风险主要是施工期的基坑开挖以及运营期间的地下设施、化粪池、冷却塔以及火灾等事故可能造成的事故环境影响,下面分别进行分析论述。11.1施工期环境风险分析11.1.1基坑开挖安全风险根据本场地地质条件,本场地强风化岩岩层较厚,本项目设计有3层地下室,在基坑大面积开挖时(后),可能存在因地质条件原因而引起的边坡失稳问题,对施工人员安全构成威胁,同时,本项目基坑开挖也可能会影响周边建筑物的安全。11.1.2人工挖孔桩施工废气中毒事故2005年9月25日,湖南省长沙市四季美景水木轩5号楼工程,1名施工人员下到桩孔内作业时中毒晕倒,另外3名施工人员陆续下井施救也中毒晕倒,共造成4人死亡。发生施工中毒重大事故的主要原因是人工挖孔桩作业中,施工人员下污水井前没有进行毒气检测或检测方法不当,或通风措施不满足要求,盲目下井作业;此外,发生中毒事故后,由于缺乏救护知识及防毒救护用具,其他人员盲目施救可能造成伤亡人数增加。11.1.3其它市政设施安全风险本项目用地场址周边可能存在有地下电缆线、供水管、供气管等市政基础设施,如果不事先弄清它们的分布即盲目开始施工,项目基坑开挖可能会对这些市政基础设施造成破坏,从而影响城市供水、供电、供气、通讯等,破坏煤气管道还可能引发重大的火灾或爆炸事故,造成人员伤亡和财产损失。这类事故在我国各地城市建设中经常发生,需引起项目业主、设计单位和施工单位的高度重视。163 广东现代国际展览中心二期扩建工程环境影响报告书11.1.4高层建筑施工安全风险主要风险因素有:(1)脚手架、模板和支撑、起重塔吊、物料提升机、施工电梯安装与运行,人工挖孔桩、基坑施工,局部结构工程或临时建筑(工棚、围墙等)失稳,造成坍塌、倒塌意外;(2)高度大于2m的作业面,因安全防护设施不符合或无防护设施、人员未配系防护绳(带)或未设置安全网等造成人员踏空、滑倒、失稳等意外;(3)焊接、金属切割、冲击钻孔(凿岩)等施工及各种施工电器设备的安全保护不符合标准,造成人员触电、局部火灾等意外;(4)工程材料、构件及设备的堆放与搬(吊)运等发生高空坠落、堆放散落、撞击人员等意外;(5)高空意外坠落的物品可能对施工场界外公众生命或财产安全构成威胁。上述风险事故一旦发生,其后果将可能十分严重,因此,必须加强施工安全管理,确保施工人员及周边人群生命与财产的安全。11.2运营期环境风险分析本项目为超高层建筑,地处建成区,项目运营期存在很多安全隐患,如风对高层、超高层建筑影响,玻璃幕墙风险,火灾与恐怖袭击等。这些事故中,超高层建筑火灾风险防范为重中之重。11.2.1火灾风险引起的次生灾害分析火灾诱发因素分析本项目楼层均为高层或超高层,可能引起火灾的因素较多,主要包括如下方面:(1)电器设备多,维护管理和使用不当;(2)明火管理不善、吸烟、机械故障或施工操作不当;(3)地下车库管理不善或通风不善而引起火灾或爆炸。地下车库如通风不良,容易积聚油蒸气而引起、火灾爆炸,通风管道是火灾蔓延的重要途径,国内外都有这方面的严重教训。地下车库一旦发生火灾,会产生大量的烟气,而且有些烟气含有一定的毒性,如果不能迅速排出室外,极易造成人员伤亡事故,也给消防员进入地下扑救带来困难。164 广东现代国际展览中心二期扩建工程环境影响报告书(4)备用发电机储油设施不良或管理失职造成的火灾风险。本项目主要使用轻质柴油为燃料,按《石油化工企业设计防火规范》标准,轻质柴油(按新柴油标准,其十六辛烷值不小于45)属乙B类火灾危险性物质,重柴油属丙A类火灾危险性物质,轻柴油相对重柴油,闪点更低,更易燃,火灾危险性也更大。本项目涉及的油品如储存及运输不当,易发生风险事故。(5)其他天灾(如雷击起火)人祸(纵火破坏)。因此可以说本项目火灾的潜伏性和可能性是很大的。火灾的危害性分析对于超高层建筑来说,一旦火灾形成,较一般建筑具有更大的危害性,主要有以下三个方面:①火灾迅速蔓延扩大这除了超高层建筑中有较多的可燃物质(装修材料、家具、物品、电线包皮)以外,超高层建筑的垂直管道、井筒形成了若干纵向的烟筒。火灾发生时,其拔风抽力效应会助长火焰和烟气的蔓延,而高度愈高、抽力愈大,这种烟筒效应就更加强烈。在超高层建筑中烟气沿楼梯间或井筒垂直上升的速度约为每秒3~4m。一座100m的建筑,如无阻挡,只要半分钟即可将火势引至顶层。所以,对超高层建筑来说,这种“烟筒效应”是最可怕的,也是最难于防范的。尽管可以在某些管道中设防火阀,但有时控制失灵或不能严密闭合都可能有火溢出而延烧。此外,火焰自窗口喷出沿外墙延烧至上一层,或借风势将火星或火焰水平吹出,引燃附近其他建筑物的情况也时有发生,建筑物愈高,可能吹得愈远,危害愈大。②疏散困难超高层建筑内聚集了大量工作人员,如纽约世贸中心双塔内容纳的工作人员为40000人,每天还有6000名观光客。一般来说,300m以上的高楼均可容纳万人以上,在火灾发生的时候,除消防专用电梯以外,一切客货电梯均须立即降到底层,不能使用。于是大量人流需通过楼梯疏散。层数愈高、人员愈多,所需的疏散时间也愈长。成千上万人要从数百米的高楼走下、走出,少则数十分钟,多则要数小时。而且,这种疏散不能寄希望于消防云梯车,一是数量有限,而且这些云梯车还要进行灭火等高空战斗作业;二是云梯车高度有限,我国的规范中消防的高空作业高度定在24m,而上海、北京等几个大城市消防云梯车的最大高度也就只能到达33m。③扑救困难165 广东现代国际展览中心二期扩建工程环境影响报告书超高层建筑发生火情,在灭火过程中,往往遇到建筑周围场地狭小,登高高度有限的具体困难。因此,即使在规范中也列有“高层建筑由于从外部扑救困难,应立足自救”的内容。如前所述高层建筑火势蔓延极其迅速,这一点造成扑救的巨大困难。此外,还有诸多不利因素也增加了扑救的难度。例如,大面积玻璃幕墙在内部高温烘烤下,向外爆炸,玻璃碎片横飞形成的玻璃雨,有如刀剑横飞,使外部消防队伍无法靠近;高空救火,水源不足或水压不够;当无消防专用电梯时,消防员只能凭体力登高,而且还需全副武装,一般攀登到8~9层,体力的消耗即已不能维持正常灭火战斗,因此使得火灾的扑救更加困难重重。综上所述,高楼失火,楼愈高,隐患愈大,一旦形成灾害,其危险性以及人、财、物方面的损失,都难以估量。因此,超高层建筑的火灾预防应慎重考虑。火灾引起的次生灾害分析火灾一旦发生,将同时引发更多的次生灾害,比如大气污染、消防扑救污水、社会恐慌及心理变化等,其中,大气污染将在附近蔓延,导致附近居民的健康受损,大量的消防污水可能在区域内不经处理而直接蔓延进入河流,对城市景观、市容及河流水质造成影响。11.2.2其它风险分析(1)超高层建筑将改变建筑物周边风场特性,高层建筑上部的迎风面与背风面的结合部形成压力差,这个压力差在结合部产生的顶推力可以使一些外墙装饰面和户外广告牌松动、脱落,造成人员伤害,甚至影响到高层建筑物本身的结构安全。(2)风对高层、超高层建筑影响很大,东莞每年7~9月为后汛期,台风活跃。当出现台风时,本项目建筑物可能会出现不同程度的摇晃情况,如果在设计和施工中不充分考虑这一问题,可能会影响电梯正常运行;广告牌(若有安装)与幕墙玻璃跌落等情况也有可能发生,对电梯使用者和街道行人的安全构成威胁。(3)高层或超高层建筑玻璃幕墙,会使地表的电场分布发生严重的畸变,其电场强度比一般建筑物大得多,容易构成雷电发展条件,再加上这些高层或超高层建筑离放电云层近,所以易遭受雷击。广州就曾发生过雷击玻璃幕墙而引起的伤人事故,东莞地区也是雷电多发区,如果防雷措施不到位,也存在玻璃幕墙被雷击的可能性。(4)地下设施可能造成的风险项目运营期间,地下室内(含地下车库)有4000多个停车位、有大量的附属设施(如166 广东现代国际展览中心二期扩建工程环境影响报告书发电机房、加压水泵房等)、还有错综复杂的各类管线等。在运营期间可能造成的风险事故主要体现在两个方面:一是通风设施不畅可能造成地下室内缺氧而造成人员窒息伤亡;二是发生火灾事件而造成财产和生命损失。(5)化粪池可能造成的风险本项目采用化粪池处理项目的生活污水,化粪池的净化机理主要为厌氧处理工艺,厌氧产物俗称沼气主要为CH4。在正常情况下,化粪池不会造成风险事故影响,但由于污水中的部分有机物质在化粪池内厌氧分解而产生甲烷、二氧化碳、氮气、氨气和硫化氢等气体,其中甲烷属于易燃易爆气体,硫化氢属于有毒气体并产生恶臭。在发生风险意外的情况下,这些易燃、易爆和有毒有害气体可能对今后工作人员的安全和健康造成影响。甲烷在与氧、空气或其他助燃性气体形成混合物中的浓度在一定范围内,遇火源即可能产生爆炸。11.3风险防范措施11.3.1施工期风险防范措施(1)基地开挖风险防范措施①基坑边坡支护须由人员经验丰富的专业单位设计。②建设单位在招标时,应保证施工设备及安全措施费为不竟价费用、专项费用;③建立完善的项目建设安全生产管理体系,落实建设施工安全责任制。④施工前应充分了解本项目用地及周边区域的地下管线分布,施工设计图中明确标识它们的位置,严格规范施工操作程序。⑤在施工界场设立围墙,确保与非施工人员的隔离。⑥超高层建筑施工时,应严格按照施工规范,做好安全防护措施(如使用水平安全网和竖向防护网、运输车量出入线路和施工人员出入线路分开等措施),防止高空坠物,保证施工工人和周边行人的人身安全。(2)人工挖孔桩中毒事故风险防范①人工挖孔桩可能发生有害气体中毒,施工单位编制专项施工方案,经监理单位签字后方可实施。②强化施工(维护)人员防护救护知识的培训教育。地基基础及其它施工企业,要强化对从事人工挖孔桩作业的施工(维护)人员的安全生产培训教育,培训教育的重点是《城市167 广东现代国际展览中心二期扩建工程环境影响报告书污水处理厂运行、维护及其安全技术规程》、《排水管道维护安全技术规程》以及个人防护和救护的基本方法,通过培训教育,增强其自我保护意识,避免盲目施救造成施救人员伤亡。11.3.2营运期风险防范措施(1)火灾风险防范措施按照我国现行的《高层民用建筑设计防火规范》要求,设计防火分区、自动消防系统、防火避难层、疏散通道等。遇火警时人们可选择最近的一处作为临时避难所。必须要设置一层防火防烟、有独立通风设备和照明设施的应急避难场所,一旦发生火灾时,可供难以外逃的楼内人员躲避。完善设施加强保养维护。在消防设计、布局方面要防患于未然,严格按照消防法的规定,尤其是在高楼内要做到配套完善,如消防栓、消防水管、消防水源、逃生通道、喷淋设施、烟感感应装置、监控装置等不可或缺,要设置防火避难层。如果高楼采用的是钢结构应该对于防火涂料进行严格保养、维护,保证其质量和安全性能,并加强管理,做到出现火险自救,避免高层建筑的灾难发生。特别要处理好以下有关事项:①高层建筑的安全疏散设施必须可靠及长期有效才能确保平时和火灾等非常时期人员的安全疏散。防烟楼梯、疏散走道应保持通畅,疏散照明、指示标志、火灾报警、灭火设施、防烟排烟等应长期有效;装修设计、装修施工不应破坏原设计的安全格局及报警、灭火设施,必须从安全防灾出发,使用不燃、无毒(或低毒)的装修材料,严格控制可燃、有毒、发烟量大的材料。进行耐火、阻燃处理时,要选用时效长的材料;要提倡在一栋建筑物内采用机械防烟与自然防烟(如带凹廊形式的自然防烟前室)相结合的防烟楼梯,真正提高防烟楼梯的安全度(如日本东京新宿中心的一些超高层建筑,大多设置一个机械和一个自然防烟的楼梯间及前室,这种组合方式,比两个自然防烟方式或两个机械防烟楼梯的安全度高);对超高层建筑,一定要做好避难层(或避难间)和屋顶停机坪等避难救灾设施;要从严掌握玻璃幕墙的设置,必要时一定要严密防火措施,如每层外墙应设窗槛墙或相应的阻止火势蔓延的其它有效设施,幕墙安装必须牢固,预防或减少因火灾、大风、地震等引发次生灾害。②合理安排、处理建筑物所需冷源、电源、气源等相关设施的安全防灾问题。建设工程制冷(采取电制冷、燃气制冷)、燃油自备发电等,都应合理布置这些设施,即要有(或预留)符合防火安全要求的场所。除电制冷外,这些场所应尽量与主体建筑分开布168 广东现代国际展览中心二期扩建工程环境影响报告书置;必须布置在主体建筑(或地下)时,应考虑燃油、燃气场所自身安全及相应安全设施的可靠性(即要考虑这些安全设施是否长期有效),特别要避免没有自然通风、采光或没有建筑防爆泄压条件的场所安排燃气设施、暗厨房等。对盛装油品等可燃液体设施的场所,要有自动灭火和防止液体流淌扩大蔓延的措施;对燃气场所,要有建筑防爆泄压、自动报警、事故排风、电气防爆以及快速切断气源装置;在平时或事故时,重要消防用电设备要保障正常供电,做到末端自投。同时,消防用电设备的电气线路应与非消防用电线路分开布置,为火灾时及时切断非消防用电设备电源和防止扩大火灾蔓延、减少损失以及为消防扑救与安全救灾创造必要条件。③建筑周围要有通畅的消防救灾道路。消防救灾道路应成环状,消防救灾道路的路面和路下各种沟、管的盖板要有承受大型消防车等救灾车辆装备的能力,一般不应小于30吨(具体可依城市实际配备的救灾装备确定)。特别要注意高层主体或裙房建筑周围向外扩展的地下室顶板和商务区的承载能力也应适应大型救灾车辆装备通行和工作的需要,否则,必将严重影响高层建筑的灭火、救人等各种救援的需要。建筑物消防必须报请政府主管消防部门的审批,按消防要求建成后必须报有关部门进行消防验收,并按要求做好防范,确保消防安全。④禁止在柴油储存处使用明火、存放或使用氧化剂等其他高温、高热行为;同时,做好防火和消防措施,并加强防范意识,则项目柴油发生的火灾的风险性较小。(2)玻璃幕墙安全风险措施本报告建议采取以下措施来降低玻璃幕墙的安全风险。①合理选择玻璃面积,玻璃面积越大越容易炸裂,抗压性能越差,面积的确定可参照《玻璃幕墙工程技术规范》。②尽量选用增强玻璃即钢化玻璃和热汇款单强玻璃(半钢化玻璃),特别是热增强玻璃。钢化玻璃的强度是普通退火玻璃的3~5倍,可有效地抵御外来物的冲击,但钢化玻璃存在自爆的问题。热增强玻璃的强度虽然只是钢化玻璃的一半左右,但热增强玻璃不易发生自爆。玻璃安装时不要在玻璃上留下装配应力。按有关规范进行施工,尽量减少玻璃变形。(3)地下设施①合理布置各种管线;②合理设计车辆的出入;③加强地下室内的通风条件,保证通风设施的正常运转;④项目应确实做好水消防、泡沫消防、消防报警和自动检测报警系统等一系列的消防与169 广东现代国际展览中心二期扩建工程环境影响报告书安全技术设施,并应经消防等相关部门核定。(4)其它措施①加强大楼物业管理,保证用电、用水、用气等安全,做好消防保证措施。②化粪池的设计施工必须严格按照国家规范执行,在运营期间需要有人按时对其排气口进行检查,避免杂物堵塞;化粪池池盖在运营中应该处于封闭状态,避免小孩或行人掉入。设计防爆装置,定期3~6个月清淘一次,防止外溢,保证使用安全。③在设计中,应充分考虑台风对本高层建筑的影响。当建筑物楼顶要安装广告牌时,一定要充分考虑东莞最大台风时的安全需要,须委托有资质的单位按照国家规范的要求设计施工,确保安全。玻璃幕墙也要能经受住台风的袭击。④本项目建筑物的高层与底层玻璃幕墙均应安装屏蔽防雷设施。⑤按照国家规范,合理安排消防交通组织,确保消防扑救面和消防通道的畅通。11.4风险应急措施为保证突发火灾事故的应急工作能及时有序地开展,项目物业管理及主管部门必须制定环境风险应急预案。通过预案的编制,建立反应灵敏,运转有效的应对突发火灾事故的指挥系统和处置体系,力求预案贴近实际,可操作性强,一旦突发火灾事故,各部门和各工作机构能按本预案协同联动,果断处置,将损失降至最低。1、组织、工作机构及职责:突发火灾事故应急指挥部(物业管理部主任)报警及补救组疏散组引导组警戒组医疗救护组负责扑救初起火灾,向应负责组织并引负责小区外救在火灾发生部负责伤员的现急指挥部报告现场情况导火灾发生部援车辆及人员位周围进行警场救护及转往并根据指挥部命令,向公位人员疏散到的引导。戒,保护现场,医院。安消防部门报警。安全地带。防止无关人员进入。2、应急处理当发生火情时,发现者应立即向管理处报警,管理处接警后要立即赶赴现场处置,根据火情决定是否启动应急预案。170 广东现代国际展览中心二期扩建工程环境影响报告书(1)如局部发生火险,火势很小,极易扑灭时,发现人员在及时向管理处报警的同时,利用现场器具进行扑救,保卫人员到场后,可视情调集其他部位的灭火器进行扑救。(2)如火势较大,有可能蔓延时,管理处要立即向公安消防部门报警,并通知有关人员启动应急预案,有关人员接到通知后,各工作小组自动组成,迅速到位,按各自职责展开工作。A、报警及扑救组要立即调集所属成员和灭火器具扑救和控制火灾。并随时向指挥部报告火场情况。B、疏散组要迅速打开起火部位疏散门组织火场人员按疏散路线撤离至安全地带。C、引导组要派出人员车辆到小区路口迎候消防车等并引导至现场。D、在公安消防队到场后,扑救组撤出火场,转为警戒组,协助公安部门作好外围警戒。E、医疗救护组根据现场情况做好伤员救治。171 广东现代国际展览中心二期扩建工程环境影响报告书第12章环境管理与环境监控计划12.1环境管理12.1.1环境管理机构设置的目的环境管理机构的设置,目的是为了贯彻执行中华人民共和国环境保护法的有关法律、法规,全面落实国务院关于环境保护若干问题的决定的有关规定,对项目―三废‖排放实行监控,确保建设项目经济、环境和社会效益协调发展;协调地方环保部门工作,为企业的生产管理和环境管理提供保证,针对拟建项目的具体情况,为加强严格管理,企业应设置环境管理机构,并尽相应的职责。12.1.2环境管理机构的设置1、机构组成根据本工程的实际情况,在建设施工阶段,工程指挥部应设专人负责环境保护事宜。工程投入运营后,环境管理机构由物业管理部门负责,下设环境管理小组,对该项目环境管理和环境监控负责,并受项目主管单位及环保局的监督和指导。2、环保机构定员施工期在建设工程指挥部设2~4名环境管理人员。运营期应在物业管理部门下设专门的环保机构,并设专职的环保管理人员1名,垃圾处置人员2名,绿地养护人员4名。12.1.3环境管理机构的职责1、贯彻、宣传国家的环保方针、政策和法律法规。2、制定小区的环保管理制度、环保技术经济政策、环境保护发展规划和年度实施计划。3、监督检查该项目执行―三同时‖规定的情况。4、定期进行环保设备检查、维修和保养工作,确保环保设施长期、稳定、达标运转。5、负责小区环保设施的日常运行管理工作,制定事故防范措施,一旦发生事故,组织污染源调查及控制工作,并及时总结经验教训。172 广东现代国际展览中心二期扩建工程环境影响报告书6、负责对小区环保人员和居民进行环境保护教育,不断提高居民的环境意识和环保人员的业务素质。12.1.4施工期环境管理计划1、环境管理机构对施工期环境保护工作全面负责,履行施工期各阶段环境管理职责。2、对施工队伍实行职责管理,要求施工队伍按要求文明施工,并做好监督、检查和教育工作。3、按照环保主管部门的要求和本报告书中有关环境保护对策措施对施工程序和场地布置实施统一安排。4、土建工程需要土石方的挖掘与运输、管道挖沟、施工建材机械等占地,对产生的扬尘应及时洒水,及时清除弃土,避免二次扬尘。5、合理布置施工场内的机械和设备,把噪声较大的机械设备布置到远离居民的地点。6、由于项目施工量大、施工周期相对较长,建议项目在施工的时候,由施工单位和有环评资质的单位联合成立一个工程环境监理小组进行施工环境监理,对施工期采取的措施进行监管。项目施工期环境保护管理及监理的主要内容见表12.1-1。173 广东现代国际展览中心二期扩建工程环境影响报告书表12.1-1施工期环境管理及监督主要内容防治对象防治措施环境管理环境监理施工场地硬化,使用商品混凝土;建筑垃圾及多余弃土及时清运;建设行政管理部门及施工场地车辆出入口设置车辆冲洗及沉淀设环境管理部门进行定施;期检查,如违反《东莞施工扬尘对工地及进出口定期洒水抑尘、清扫,保持工市大气污染防治条地整齐干净;例》,应进行处罚并整禁止焚烧熔化沥青;改。对回填土方进行压实或喷覆盖剂处理;施工单位环保措建筑工地按有关规定进行围挡。施上墙,落实到将投标方的低噪声施工设备和技术作为中标人,做好施工场地内容;环境管理和保洁施工单位开工15日前,携带施工资料等到当环保监理部门对夜间工作。地环保部门申报《建设施工环保审批表》,经施工噪声进行监督检施工噪声批准后方可施工;查,违反《东莞市环境作业时间严格限制在七时至十二时,十四时至噪声污染防治条例》,二十时;应进行处罚并整改。因施工浇筑需要连续作业的施工前3天内,由施工单位报环保部门审批。施工人员生活污水应集中排入城市污水管网;水——避免在雨季进行基础开挖施工。建筑垃圾及多余弃土及时清运,不能长期堆建筑及生活渣土清运至指定存,做到日产日清,车辆用毡布遮盖,防止沿——垃圾地点填埋途散落。12.1.5运行期环境管理计划(1)制定各种环保设施操作规程、定期维修制度,使各项环保设施在运行过程中保持良好的状态;(2)对技术工人上岗之前进行有关的环保知识、环保法规等方面的教育,以及操作规范的培训。使各项环保设施和机械的操作规范化,保证环保设施的正常运转;(3)加强对环保设施的运营管理,严禁在非正常条件下进行排放;(4)加强环境监测工作,对污水处理出水口要进行实时监测,要有详细的记录,不得弄虚作假。对废水监测发现异常情况应该及时向有关部门通报,及时采取应急措施,防止事故排放;(5)加强与周围居民以及本项目区域内商住及办公人员的联系,接受公众的监督,增加公众参与力度。174 广东现代国际展览中心二期扩建工程环境影响报告书12.2环境监控计划项目从控制污染、保护和改善环境的角度出发,根据项目的工程特点、排污状况以及针对不利环境的因素所采取的措施,制定确保环保措施能够落实的环境监测计划并加以执行。环境监测计划的实施,使项目在建设期和运行期的各种环境问题及时被发现并加以解决,在发展经济的同时、保证环境质量不致下降。12.2.1施工期环境监测计划(1)施工污水监测点:施工场地的生活污水、高浓度SS废水和含油废水监测项目:COD、BOD5、动植物油、SS监测频率:每季度监测一次(2))施工废气监测点:施工营地监测项目:TSP、PM10监测频率:每季度监测一次(3)噪声监测点:施工场界外1米处监测项目:等效连续A声级监测频率:每季度监测2天,每天昼间、夜间各监测一次。12.2.2运营期监测计划为了掌握大气、水、固体废物等污染源的排放情况和噪声源的影响情况,控制项目所在位置与周围环境中主要污染物状况,保证周围人群的健康,该公司拟采取委托东莞市环境监测中心站监测的办法,以便及时发现营运过程中所带来的环境问题,加以监督管理。(1)环境空气监测计划在发电机尾气的排气口设立监测点,每年监测一次,监测烟气量和烟气黑度,确保达标排放。(2)环境噪声监测计划175 广东现代国际展览中心二期扩建工程环境影响报告书进行常规定期监测。主要对该项目边界噪声、附近敏感点噪声进行监测,监测因子是Leq(A),每年监测1次。(3)固体废弃物监测计划加强对生活垃圾的管理,定期清理统一处置,并要做好垃圾堆放点的消毒、杀虫工作。12.3环保措施“三同时”、生态验收汇总三同时主要指的是用于运营期防治的措施,必须在设计的时候同时设计,施工的时候同时施工,投产的时候同时投入使用。建议环保验收的主要内容有:176 广东现代国际展览中心二期扩建工程环境影响报告书表12.3-1环保措施―三同时‖验收汇总表序号类别污染物验收内容执行标准生活污水是否经三级化粪池处理后排放市政管网;项目区内是否实现了雨污营运《水污染物排放限值》(DB44/26—2001)第1生活污水分流,雨水口和排污口是否废水二时段三级标准分别与市政污水收集管网和市政雨水收集管网正确对接地下车库进、排风系统是否满足通风换气需要,排风井广东省地方标准《大气污染物排放限值》2机动车尾气口位置是否避开了人行道(DB44/27-2001)中第二时段二级标准或其它敏感点烟气黑度排放限值按林格曼黑度1级执行,对营运二氧化硫、氮氧化物、烟尘等污染物的排放应废气是否经水喷淋(添加碱液)3发电机尾气执行《大气污染物综合排放标准》处理后高空排放(GB16297-1996)新污染源大气污染物排放限值中的二级标准是否集中收集后,引入绿化4垃圾站废气达到恶臭污染物排放标准中二级标准带排放固体5生活垃圾是否由环卫部门统一处理——废物水泵、配电房、设置于专用房内,并设减震备用发电机噪达到《社会生活环境噪声排放标准》(GB123486噪声装置声-2008)2类标准冷却塔是否采取隔声降噪措施7生态/绿地率达20%/177 广东现代国际展览中心二期扩建工程环境影响报告书第13章环境影响经济损益分析13.1环境效益分析13.1.1项目对环境带来正面影响(1)项目的开发、建设,与周围城市景观相协调,充分而合理地利用东莞市宝贵的土地资源,即满足了发展的需求,又美化了环境;(2)项目绿地建设,对净化、美化环境起到了一定的有利作用;(3)项目良好的建筑,可丰富城市的人文景观。13.1.2项目对环境带来负面影响(1)项目建成后水泵房、机动车、发电机等噪声对周围声环境造成一定的影响。(2)项目施工期的扬尘、污水和施工噪声对周围大气环境造成一定影响。(3)项目的开发建设改变了原有的城市人工系统。13.2社会效益分析本项目的建设将会极大的提高城市功能,树立家具中心的主导地位,增加片区的财政税收,创造较多的就业机会。同时,由于本项目是一个集高端办公和商业为一体的综合性项目,本项目的建设也将极大的带动片区的商务价值和商务收入,吸引更多的国际企业以及外资,从而创造显著的社会效益。13.3经济效益分析本项目总投资199187万元人民币,根据项目的可行性研究,项目经济收入估算情况见表13.3-1。根据估算结果,本项目建设具有良好的经济效益。178 广东现代国际展览中心二期扩建工程环境影响报告书表13.3-1本项目经济收入估算表序号项目名称总额(万元)1项目经营收入(万元)377,546.602税前利润(万元)67,6683税后利润(万元)48,1744成本利润率(税前)33.87%5成本净利润率(税后)24.12%6投资回收期(年)513.4环境损益分析13.4.1环境损失本项目在创造一定的经济效益和社会效益的情况下,由于项目运营过程中需要消耗一定的资源与能源,同时排放污染物,对环境和社会也造成了一定的损害。主要体现为项目的运营将消耗东莞市本来就有限的水资源和电力资源,加剧人口膨胀。13.4.2环保投资估算项目环保投资1147万元,占总投资的0.7%。详见表13.4-1。179 广东现代国际展览中心二期扩建工程环境影响报告书表13.4-1环境保护投资估算时段环保措施预计投资(万元)施工场地绿化10水土流失排水沟、沉砂池等80水土保持方案编制100水污染化粪池、排污管网、隔油池等60大气污染施工扬尘控制60施工期噪声声源控制80生活垃圾处理30固体废物建筑垃圾处理200危险废物20其他施工期环境监理80水污染化粪池、应急池、地面防渗等120发电机尾气防治50大气污染垃圾站臭气排放及加强绿化615地下车库通风换气40冷却塔噪声治理70运营期噪声发电机噪声治理60设备机房隔声消声措施65垃圾箱5固体废物危险废物临时存放箱2其他绿化纳入总体工程――――合计114713.4.3环保投资收益分析环保投资收益主要体现在间接效益,即减少了废水、废气、噪声和固体废物排放对环境带来的影响。13.5结论1、项目具有较好的市场前景,可以投资开发。2、项目将会带来较好的经济效益,是一项较好的投资项目。3、项目由于规模大、投资大、工期长等,可能存在一定的投资风险,需要在工程管理和经营管理等方面进行努力,在控制成本的同时保证建筑质量,进一步降低风险。4、项目环保投资1147万元,占总投资的0.6%,环保投资基本合理。180 广东现代国际展览中心二期扩建工程环境影响报告书第14章项目建设与选址合理合法性分析14.1项目建设与选址可行性分析14.1.1与产业政策的相符性分析对照《产业结构调整指导目录(2011年本)》、《广东省产业结构调整指导目录(2007年本)》、《东莞市产业导向目录(2008年本)》,会展场馆的建设不在目录中的淘汰、限制类,项目建成后提供会展服务,属于其中的鼓励类,故项目建设符合国家、广东省及东莞市产业政策。14.1.2场址所在地与周边环境功能的相适性根据《广东省地表水功能区划》(粤环[2011]14号),东莞运河执行《地表水环境质量标准》(GB3838-2002)III类水质标准。本项目所在地执行《环境空气质量标准》(GB3095-2012)二级标准。本项目所在地执行《声环境质量标准》(GB3096-2008)2类标准。从本次环境现状调查来看,区域大气环境质量基本能满足功能区划要求:(1)区域环境空气质量现状:评价区内监测点的SO2、NO2、PM10浓度达到《环境空气质量标准》(GB3095—2012)中的二级标准要求,项目区苯、二甲苯浓度能满足《工业企业设计卫生标准》中居住区大气中有害物质的最高容许浓度。(2)评价水域环境质量现状:各监测点位均超标的项目有BOD5、氨氮、总氮,此外,厚街沙塘污水处理厂排污口处(1#)COD超标,水质相对较好;厚街沙塘污水处理厂出水纳污河流——东莞运河下游1000米处断面(2#)DO、COD、总磷、阴离子表面活性剂等项目均超出《地表水环境质量标准》的III类标准,水质较差;厚街沙塘污水处理厂排污口上游400米东莞运河与支流A交汇处断面(3#)DO、总磷超出《地表水环境质量标准》的III类标准。从超标倍数看,三个监测断面氨氮、总氮超标倍数在7.5-10.2之间,说明东莞运河在沙塘污水处理厂排污口上游400米至下游1000米范围内有机污染严重,水质较差。(3)评价范围声环境质量现状:项目地块北面、南面边界能满足《声环境质量标准》(GB3096-2008)中4a类标准,其余各监测点均超出《声环境质量标准》(GB3096-2008)中2类标准,其中地块西面边界昼间超标1.2~1.3dB(A)、夜间超标2.1~2.5dB(A),东面边181 广东现代国际展览中心二期扩建工程环境影响报告书界昼间超标8.9~9.5dB(A)、夜间超标4.7~4.8dB(A);项目地块内昼间超标2.1~4.3dB(A)、夜间超标2.9~3.4dB(A)。项目地块周边较为开阔,东面省道S256部分道路封闭进行地铁R2线及穗莞深城际轨道施工,施工噪声和道路交通噪声对周边声环境影响较大。随着施工的结束、城市道路的畅通,区域声环境将得到改善。(4)环境容量:从近几年区域环境质量调查和监测结果来看,项目区域的环境空气还有一定的环境容量,水环境已无环境容量,项目污水经预处理后排入东莞市厚街沙塘污水处理厂,不直接排入水体,生活污水经污水处理厂处理后对纳污水体功能影响不大。再通过区域削减等手段后,可大幅削减其中污染物,恢复纳污水体的水环境容量。14.1.3与《珠江三角洲环境保护规划纲要(2004-2020年)》相符性分析项目所在区域不属于《珠江三角洲环境保护规划纲要(2004-2020年)》中的“严格保护区”,项目通过实施绿化措施提高区域的绿地率,改变原来较为低下的生态系统,并采取积极有效的措施促进区域生态环境质量的改善和提高,因此,项目建设是与《珠江三角洲环境保护规划纲要(2004-2020年)》相符合的。14.1.4城乡规划的相符性分析目前,本项目所在片区尚未发布法定图则。根据《东莞市厚街镇会展片区控制性详细规划》,本项目用地属于会展用地(见附图14.1-1)。根据2012年4月颁发的《东莞市建设用地规划批准书》,属于会展用地,符合城市规划要求,准予办理有关手续。因此本项目用地性质为会展用地,项目建设符合城市规划要求。项目不涉及占用划定的基本农田保护区,该项目用地符合《广东省环境保护规划纲要(2006-2020年)》、《广东省环境保护条例》、《珠江三角洲环境保护规划纲要》(2004-2020年)》等国家供地政策。因此,项目的选址基本符合规划、国土部门的相关规定。182 广东现代国际展览中心二期扩建工程环境影响报告书14.2项目布局合理性分析(1)总体布局本项目根据规划设计,从规划上充分发掘地块潜力,综合考虑周围环境,将办公塔楼布置在用地的东北侧,这里可以与周边的办公建筑呼应,使其影响力辐射到周边,成为东莞市的一座地标。展馆布置在用地的西侧、南侧,可以加强与周边路网的联系,轨道交通与路面交通有机的结合在一起,相互协调,总体布局合理。此外,本项目布置有合理的人、车交通流线,消防车道沿建筑物环形布置,利于消防车辆的进出。(2)污染源布局合理性分析本项目内部污染源包括备用发电机、冷却塔、水泵、风机等机电设备以及厨房油烟、化粪池、地下车库等。大气污染源:本项目拟将备用发电机废气通过专用烟道于展馆楼顶排放,共设置两台发电机,排气筒分别布置在展览馆A区东、西侧,距离周边的敏感点较远,影响较小。噪声源:①本项目主要噪声源如备用发电机、水泵、冷水机组和风机等设置在地下室专用设备用房内,通过墙壁的屏蔽和距离的衰减,可以减少其不良影响。②外博大厦裙房楼顶拟设置14台低噪音冷却塔、展览馆楼顶拟各设置22台低噪音冷却塔,在采取隔声措施的情况下,该布置方案能够有效避免冷却塔运行噪声对周边敏感点的影响。综上分析,本项目建筑物总体布置和污染源布局来是比较合理的。项目各类废气排放源与周边敏感点的位置关系见附图14.2-1。14.3关于绿地率的建议核查《东莞市厚街镇会展片区控制性详细规划》和本项目经济技术指标(见表2.2-1和表2.2-2),项目各项指标均能满足《东莞市厚街镇会展片区控制性详细规划》F04-03地块的要求,仅绿地率低于20%,因此,建议建设单位根据项目实际情况规划绿地面积,尽可能达到《东莞市厚街镇会展片区控制性详细规划》的要求,并充分利用空间进行绿化,以增加用地内的绿化率。14.4小结183 广东现代国际展览中心二期扩建工程环境影响报告书分析表明,该项目符合产业政策、环保规划和环境功能区划,项目建设定位于高端住宅区,其本身产生的环境污染及环境破坏较小,且自身对环境质量要求非常高,项目总平面布置基本合理,与周边环境有较好的相容性。因此,只要建设单位加强管理,对项目进行科学规划设计,认真落实“三同时”管理规定,采取有效的环境保护措施,其开发建设不会对周围地表水环境、区域环境空气质量、声环境质量、生态环境质量等造成明显不良影响。184 广东现代国际展览中心二期扩建工程环境影响报告书第15章公众参与根据《环境影响评价公众参与暂行办法》环发【2006】28号和《广东省建设项目环保管理公众参与实施意见》粤环【2007】99号的规定,拟采取在网站上公布公示信息(两次)的形式进行公示。即在环境影响评价机构接受委托后进行第一次公示;在编制环境影响报告书的过程中,报送环境保护行政主管部门审批或者重新审核前,进行第二次公示。拟采取发放问卷调查的形式征求公众意见。调查对象应包括项目所在地周围居民点的群众,特别关注直接或间接受影响的人群。15.1公众参与目的、范围、工作程序一、众参与的目的与原则公众参与指在环境影响评价过程中,就建设项目潜在的环境影响以及与之相关的减缓措施等与公众进行交流的过程。公众参与可分为信息公开、公众意见调查(或公众咨询)、参与决策三个不同的深度。环境影响评价的公众参与工作主要侧重于信息公开和公众意见调查。(一)环境影响评价公众参与的目的1、维护公众合法的环境权益,在环境影响评价中体现以人为本的原则。2、更全面地了解环境背景信息,发现潜在环境问题,提高环境影响评价的科学性和针对性。3、通过公众参与,提出经济有效并切实可行的减缓不利社会环境影响的措施。4、平衡各方面利益,化解不良环境影响可能带来的社会矛盾。5、推动政府决策的民主化和科学化。(二)环境影响评价公众参与的一般原则1、知情原则公众参与工作中首先要进行信息公开(国家规定需要保密的信息除外),保证在公众知情的基础上开展公众意见调查。2、公开原则公开并真实地向公众披露建设项目的相关情况,并保证它们的及时有效。3、平等原则185 广东现代国际展览中心二期扩建工程环境影响报告书努力建立利害相关方之间的相互信任,不回避矛盾和冲突,平等交流和观点,充分理解各种不同观点看法,尤其不能忽视弱势群体的意见和反对意见,避免主观和片面。4、广泛原则设法使不同社会、文化背景的公众参与进来,既重点征求受建设项目直接影响公众群的意见,又保证其他公众群有发表意见的机会。5、便利原则根据建设项目的性质以及所涉及区域公众的特点,选择公众易于获取的信息公开方式和便于公众参与的调查方式。二、公众参与工作的一般程序环境影响评价中的公众参与原则上分为三个阶段,如图15.1-1所示。资料收集背景情况分析资料收集第一阶确定公众参与工作等级段制定核心公众代表制定公众参与计划信息公开第公众意见调查二阶段公众意见汇总分析编写公众参与篇章第三阶段信息反馈图15.1-1环境影响评价中公众参与工作程序186 广东现代国际展览中心二期扩建工程环境影响报告书第一阶段为准备阶段,首先根据建设项目的进展情况,收集建设项目信息、相关法律法规和政策、当地自然文化和社会等方面的资料,然后在综合分析上述信息的基础上,结合公众参与工作等级确定核心公众代表,制定有效的公众参与工作计划。第二阶段为实施阶段,即公开有关信息,对公众意见进行调查分析,编写环境影响报告书中的公众参与篇章。在实施过程中,如最初确定的核心公众代表或工作计划与实际情况不相适应,应适时进行必要的调整。第三阶段是反馈阶段,主要工作是将公众意见采纳与否的信息反馈给公众,必要时进行公众意见的补充调查。三、公众参与工作等级与公众的范围(一)公众参与工作等级根据该项目所在地的敏感性确定本环境影响评价过程中的公众参与工作等级为二级。(二)公众的范围1、受建设项目直接影响的单位和个人。长期居住在项目所在地及其附近,或在上述地区拥有土地使用权的单位和个人。2、受建设项目间接影响的单位和个人。如拟建项目潜在的就业人群、供应商和消费者;受项目施工建设和运营阶段原料和产品运输、废弃物处置等环节影响的单位和个人;拟建项目同行业的其他单位或行业协会;其它相关的社会团体或宗教团体等。3、有关专家。如环保专家;熟悉建设项目所属行业的技术和管理专家;公共卫生专家;其他特定专业的专家。4、关注建设项目的单位和个人。如相关研究机构;民间环境保护组织等。5、建设项目的投资单位或个人、建设项目的设计单位、环境影响评价单位、环境行政主管部门、其他相关行政主管部门。15.2调查原则和方法一、调查原则公众参与调查遵循针对性、真实性以及普遍性与随机性相结合的原则,力求达到科学、客观、公正、全面。二、调查方法187 广东现代国际展览中心二期扩建工程环境影响报告书根据《环境影响评价公众参与暂行办法》环发【2006】28号和《广东省建设项目环保管理公众参与实施意见》粤环【2007】99号的规定,本项目以在网站上公布公示信息和现场公告(两次)的形式进行公示。公众参与调查方法采用发放问卷的方式进行,共发放调查问卷90份,回收85份,其中个人83份,单位2份。(一)第一次公示在接到项目任务后的编写阶段,于2012年6月7日至2012年6月21日,共10个工作日对项目进行了第一次公示,将该项目信息上传到我公司网站(网址:http://www.ierec.com),并在双岗村村委会、新塘小学、周边工业区及项目所在地现场进行了现场公示。图15.2-1第一次网上公示截图188 广东现代国际展览中心二期扩建工程环境影响报告书项目公告项目公告双岗村新塘小学项目公告项目公告工业区项目现场图15.2-2第一次现场公示图公示内容如下:广东现代国际展览中心二期扩建工程环境影响评价第一次公示信息---------------------------------------广东现代国际展览中心二期扩建工程由广东现代国际展览中心有限公司投资建设。根据《中华人民共和国环境影响评价法》、《建设项目环境保护管理条例》及有关文件的规定,受建设单位的委托,重庆市环境保护工程设计研究院有限公司为本项目进行环境影响评价。按国家环保总局环发[2006]28号文《环境影响评价公众参与暂行办法》有关规定,现对项目环境影响评价信息进行第一次公示,欢迎公众积极参与并提出宝贵意见。一、建设项目名称和项目概况建设项目名称:广东现代国际展览中心二期扩建工程项目性质:新建189 广东现代国际展览中心二期扩建工程环境影响报告书开发单位:广东现代国际展览中心有限公司建设地点:东莞市厚街镇,具体位置见附图。四至情况:项目北临家具大道,南临会展南路,西临F03-02地块,东临F04-01、F04-02地块。广东现代国际展览中心二期扩建工程位于东莞市厚街镇。临近S256省道、家具大道、会展南路,交通十分便利。2项目建筑占地面积64571m,总建筑面积约为71.47万平方米,其中外博大厦塔楼高480米,属于超高层建筑。项目建成后主要用于展览、办公。不设煤气、液化气等调压站,项目使用市政管道天然气。二、建设项目的建设单位名称和联系方式建设单位名称:广东现代国际展览中心有限公司联系人:劳经理联系电话:0769-85596888三、环境影响评价程序和主要工作内容依据《中华人民共和国环境影响评价法》的规定,该项目需作环境影响评价,进行国家和地方有关环境保护的法律、法规与建设项目产业政策相容性分析,开展环境现状190 广东现代国际展览中心二期扩建工程环境影响报告书调查,并对项目实施后可能造成的环境影响进行分析、预测和评估,提出预防或者减轻不良环境影响的对策和措施,最终给出环境可行性评价结论。四、征求公众意见的主要事项公众在了解了该项目建设内容和环境影响评价工作程序后,可就下列问题提看法:1、通过信息公示,您对项目的情况了解多少?2、您认为项目建设的有益之处是什么?3、在项目建设期和投入运营后,您最关心的环境问题是什么?4、您对该项目环保方面的措施有什么好的建议?5、您是否同意该项目在拟建地址建设?6、如果您不同意该项目在拟建地址建设,请说明理由,并提出您的建议。7、其他问题。五、公众提出意见的主要方式公众可采取信函、电子邮件、电话、访谈的方式提出意见,最后建设单位和评价单位采取调查问卷方式征求公众意见。六、本公告期限:自2012年6月7日至2012年6月21日。广东现代国际展览中心有限公司重庆市环境保护工程设计研究院有限公司2012年6月6日(二)第二次公示在项目报告书编写阶段,于2012年7月2日至2012年7月15日对项目进行了第二次公示,将该项目信息上传到我公司网站(网址:http://www.ierec.com)及东莞市阳光网(http://bbs.sun0769.com/),并在双岗村村委会、新塘小学、周边工业区及项目所在地进行了第二次现场公示。191 广东现代国际展览中心二期扩建工程环境影响报告书双岗村公告图15.2-3第二次现场公示(1)192 广东现代国际展览中心二期扩建工程环境影响报告书项目公告新塘小学公告项目公告项目公告工业区项目现场图15.2-3第二次现场公示(2)193 广东现代国际展览中心二期扩建工程环境影响报告书东莞阳光网公示图15.2-4第二次网上公示(简本链接)截图194 广东现代国际展览中心二期扩建工程环境影响报告书公示内容如下:广东现代国际展览中心二期扩建工程环境影响评价第二次公示信息---------------------------------------广东现代国际展览中心二期扩建工程由广东现代国际展览中心有限公司投资建设。根据《中华人民共和国环境影响评价法》、《建设项目环境保护管理条例》及有关文件的规定,受建设单位的委托,重庆市环境保护工程设计研究院有限公司为本项目进行环境影响评价。按国家环保总局环发[2006]28号文《环境影响评价公众参与暂行办法》有关规定,现对项目环境影响评价信息进行第二次公示,欢迎公众积极参与并提出宝贵意见。一、建设项目名称和项目概况建设项目名称:广东现代国际展览中心二期扩建工程项目性质:新建开发单位:广东现代国际展览中心有限公司建设地点:东莞市厚街镇,具体位置见附图。四至情况:项目北临家具大道,南临会展南路,西临F03-02地块,东临F04-01、F04-02地块。广东现代国际展览中心二期扩建工程位于东莞市厚街镇。临近S256省道、家具大道、会展南路,交通十分便利。2项目建筑占地面积64571m,总建筑面积约为71.47万平方米,其中外博大厦塔楼高480米,属于超高层建筑。项目建成后主要用于展览、办公。不设煤气、液化气等调压站,项目使用市政管道天然气。二、建设项目的建设单位名称和联系方式建设单位名称:广东现代国际展览中心有限公司联系人:劳经理联系电话:0769-85596888三、环境影响报告书提出的建设项目对环境可能造成的影响概述项目为会展展馆、超高层办公楼建设项目,其对环境可能造成的污染主要有:1、生活污水:主要为工作人员办公过程产生的废水。2、商业部分会产生一定量的油烟、餐饮废水。195 广东现代国际展览中心二期扩建工程环境影响报告书3、机动车尾气:项目地下停车位进出机动车会排放一定量的尾气。4、生活垃圾:生活垃圾等固体废物。5、辅助设备噪声等,如备用机、水泵等,噪声级为60~85dB(A)。6、超高层建筑可能影响周边居住区的日照,带来高楼风、光污染等不良影响。7、会展期间,可能引起周边交通量增大,引起交通拥堵。四、环境影响报告书提出的主要环保措施1、区内雨水收集系统由雨水明沟、雨水管组成,室外雨污分流,室内污废合流,设专用污水管。建设项目生活污水经三级化粪池处理后排放市政管网,最终进入城镇污水处理厂达标排放。2、对于发电机组产生的燃油尾气通过水喷淋(添加碱液)处理装置里后由所在建筑内置烟井引至楼顶高空排放。3、将收集的生活垃圾统一交环卫部门清运至垃圾处理厂,统一集中处置。4、合理布局,选用低噪声设备,加强减震、隔音措施,使项目排放噪声达到《社会生活环境噪声排放标准》(GBl2348-2008)2类标准。五、环境影响报告书提出的主要结论该项目符合产业政策,该项目建成后可能会对环境造成废水污染、废气污染和噪声污染影响,其中以生活污水污染及油烟废气、备用发电机尾气为主要影响因素。建设单位只要在建设中严格执行―三同时‖规定,合理采纳和落实本环评报告中所提出的环保措施,同时确保环保处理设施正常运行,使项目建成后对环境影响减少到最低限度。根据大量的依据和采取的措施,从环境保护的角度来看,项目的建设可行。六、征求公众意见的主要事项公众在了解了该项目建设内容和环境影响评价工作程序后,可就下列问题提看法:1.通过信息公示,您对项目的情况了解多少?2.您认为项目建设的有益之处是什么?3.在项目建设期和投入运营后,您最关心的环境问题是什么?4.您对该项目环保方面的措施有什么好的建议?5.您是否同意该项目在拟建地址建设?6.如果您不同意该项目在拟建地址建设,请说明理由,并提出您的建议。7.其他问题。196 广东现代国际展览中心二期扩建工程环境影响报告书八、公众提出意见的主要方式公众可采取信函、电子邮件、电话、访谈的方式提出意见,最后建设单位和评价单位采取调查问卷方式征求公众意见。九、本公告期限:自2012年7月2日至2012年7月15日。广东现代国际展览中心有限公司重庆市环境保护工程设计研究院有限公司2012年7月2日附图项目位置图注:本项目设计方案在技术审查阶段发生了变化,与第一次公示、第二次公示及公众调查时的设计资料有所改变,主要调整的内容如下:建筑面积中增加垃圾站的建设、备用发电机和冷却塔的台数减少了、去掉了餐饮业等。197 广东现代国际展览中心二期扩建工程环境影响报告书(三)采用发放意见征询表的方式,由专人现场问卷调查,并填写。15.3公众意见征询表发放和结果统计公众参与过程中通常采用发放公众意见调查表、召开公众意见咨询会、登门拜访和利用大众传媒发布与项目有关的信息等多种形式。通过对该项目主要的环境问题及其影响的初步分析,本次评价决定采用简单、易行的发放公众意见调查表形式进行公众参与的调查工作。于2012年7月初对项目建设区域内及周围的单位、居民等进行了“广东现代国际展览中心二期扩建工程”公众意见征询工作。调查表包括“工程简介”和“调查问卷”两部分。工程简介对城市规划、拟开发区域的现状、拟建项目的投资、规模、选址及主要建设内容进行了简要的介绍,并对施工期和运营期将产生的环境影响进行了说明。15.3.1公众意见征询表在本次评价中将对项目进行公众参与调查,调查对象为:当地居民及周边单位。此次调查总发放92份表格,回收88份,其中个人83份,单位5份。然后对调查结果进行统计分析。调查表见表15.3-1。表15.3-1广东现代国际展览中心二期扩建工程公众意见征询调查表一、参与者基本情况姓名性别年龄民族职业文化地址(工作单位)联系电话198 广东现代国际展览中心二期扩建工程环境影响报告书二、项目简介广东现代国际展览中心二期扩建工程位于位于东莞市厚街镇,地块所属编号为F04-03。F04-03地块内已建成展览馆B、C、D区,现在F04-03地块剩余的用地上新规划二期扩建2工程,内容包括外博大厦和A、B区展览馆、C区停车楼。项目建筑占地面积64571m,2总建筑面积约为71.47万m,其中外博大厦塔楼高480m,属于超高层建筑。项目建成后主要用于展览、办公。项目北临家具大道,南临会展南路,西临F03-02地块,东临F04-01、F04-02地块。运营期配备有1000KVA发电机6台,水冷离心式冷水机组8台。项目不设煤气、液化气等调压站,项目使用市政管道天然气。项目建成投入使用后对周围环境可能产生影响的主要因素有居住小区居民;物管工作人员的生活污水;商业污水;备用发电机尾气、机动车尾气;水泵房、机动车等噪声;备用发电机、水泵房、机动车等噪声;生活垃圾等。一、废水处理措施:建设项目生活污水经三级化粪池处理后排放市政污水管网,最终进入城市污水处理厂达标排放。二、废气处理措施:对发电机尾气经水喷淋处理后于高处排放。三、固废处理措施:对生活垃圾进行集中收集。由物业管理部配专人清扫。将收集的生活垃圾统一交环卫部门清运至垃圾处理厂,统一集中处置。四、噪声处理措施:将水泵、风机、发电机等置于专用房内,采取隔声、消声、吸声及减三、调查内容1振等综合措施;在小区周围道路两旁植树绿化,以减少道路交通噪声对小区、您是否知道“广东现代国际展览中心二期住户干扰。□知道□不知道扩建工程”的建设2、本项目建设对当地经济、文化的影响□有利□一般□不清楚□污水排放□废气排放□噪声污染3、本项目的主要环境影响表现在□固废□无□其它4、本项目的建设对周围环境的影响□有影响□影响不大□无影响5、你是否满意本项目采取的环保措施□满意□不满意□不清楚6、您对本项目的建设持什么态度□赞成□反对□不关心7、若您反对,您反对的主要原因是:8、您对本项目在环保方面有什么建议?199 广东现代国际展览中心二期扩建工程环境影响报告书注:项目进行公调后,项目的备用发电机等设计资料有所改动,但是不影响整个项目的情况,因此,公调资料不再进行改动。15.3.2公众参与调查结果本次调查共发放问卷92份,回收88份,回收率为95.7%。公众参与调查统计结果见表15.3-2。公众参与调查对象中环境敏感点公众人数占总人数的70%以上,敏感点的单位占被调查单位的70%以上。受调查人员和参与调查对象、单位100%在项目环境影响评价范围内。公众信息表见表15.3-2,调查结果统计见表15.3-3。表15.3-2公众信息表序号姓名住址联系方法意见1李进厚街镇双岗村13612693278赞成2余静新塘15118287334赞成3方淦强厚街镇寮厦管理区二村13926811929赞成4林集永厚街镇双岗上环村13802371122赞成5谢妙群新塘13570065103赞成6李乃日厚街镇双岗村13652492658赞成7方肖霞新塘13538663663赞成8陈少欢厚街新塘上塘村13622621211赞成9伦沛良厚街新塘上塘村13713088630赞成10梁素芬厚街镇新塘村13802453731赞成11陈秀文厚街新塘上塘村六巷3号13686040222赞成12方敬傍新塘13751228843赞成13方沛基东莞厚街新塘古坑村13712018328赞成14方伟雄东莞溪头村13539082288赞成15陈笑弟厚街新塘上塘村小组13728296678赞成16林祝笑东莞厚街新塘新地村13826962288赞成17黄文雅新塘13827291881赞成18卢实稳厚街自濠村13602376033赞成19梁杰东莞市华源建筑工程有限公司88598182赞成20谭发梅新塘13580985939赞成21林正全东莞市厚街镇双岗村1362333388赞成22黄禄艺东莞华源实业有限公司13712642356赞成23刘金厚街新塘村13712061643赞成24陈匡峰厚街镇家具大道12号15989207619赞成25方俏洁东莞市厚街镇寮厦村15820899240赞成26劳壮健嘉华酒店13790698378赞成27罗林高奥天贸易13929255850赞成28方振威东莞市厚街镇寮厦村15999877480赞成200 广东现代国际展览中心二期扩建工程环境影响报告书29钟运晓家具大道13326851812赞成30林标豪家具大道18988717773赞成31刘芊牟新塘18938283152赞成32韦威珩溪头13729913388赞成33张晓敏溪头13412880008赞成34方燕雯溪头13713095127赞成35成完平溪头18928208807赞成36梁美玲厚街镇新塘村18802600712赞成37王德福厚街镇新塘村13728278432赞成38黄声达厚街镇新塘村15362442183赞成39黄志东厚街镇新塘村13925702478赞成40刘日莎厚街镇新塘村13620032463赞成41黄寿金欧陆酒店13829125586赞成42李红欧陆酒店15217781500赞成43梁水娇嘉怡旅馆85596888赞成44陈小林永昌五金13418354401赞成45陈颖湘新塘13798744927赞成46刘波东莞厚街珊美村13712913749赞成47刘北波东莞厚街新塘保纳村13712201812赞成48温松轩双岗慕思18664051517赞成49温汝珍双岗村13713241771赞成50赵培兰家具大道8号15377744670赞成51林润红厚街双岗上环村13412824592赞成52刘艺华厚街镇莞太路新塘路段13556661162赞成53李成厚街家具大道5号13825018788赞成54夏良媛华源公司13544652011赞成55李伟鹏嘉华13412789201赞成56林宝婷永昌五金13729912377赞成57清万润东莞市建设管理有限公司13549266198赞成58陈州芮厚街镇新塘村13924331873赞成59刘海波厚街镇家具大道12号18607753531赞成60林顺章厚街家具大道5号13611472195赞成61方金森厚街镇尞厦二村13592758099赞成62王映璋东莞华源企业集团有限公司13553838776赞成63刘乃珍厚街镇尞厦二村13622672682赞成64林艳婷创灵广告13729912376赞成65郭志刚韶关地质工程勘探院13924335008赞成66老业平厚街镇家具大道3号13620031009赞成67卢秩标东莞市华辉家具有限公司13826917112赞成68刘志星厚街镇双岗上环永宁东路一巷13790210920赞成69卡平稳厚街镇白濠村13712703803赞成70陈少芬厚街镇寮厦村13728113330赞成201 广东现代国际展览中心二期扩建工程环境影响报告书71王妙玲厚街新塘村委会13726988731赞成72林燕玲厚街新塘村13544801288赞成73梁勇厚街镇新塘村15016988608赞成74方近光厚街镇寮厦村13926830855赞成75罗志伟厚街新塘13712926178赞成76徐清华源建筑13211560251赞成77林凤欣厚街双岗上环村13712850372赞成78黄叶恋嘉华酒店15091078014赞成79刘华健厚街家具大道12号13712609132赞成80卢安稳厚街白濠村13929273811赞成81蒋坤厚街双岗上环村永宁东路一巷20号13712206292赞成82陈笑房南五13686223550赞成83王映章厚街镇涌口村13437472111赞成表15.3-3公众调查问卷单位基本情况汇总表序号单位名称联系人联系电话意见1东莞市厚街镇新塘社区居民委员会陈沛枝13712117799赞成2东莞市厚街镇双岗社区居民委员会方师法13602305628赞成3东莞市厚街镇河田社区居民委员会赞成4东莞市厚街镇溪头社区居民委员会方沛全85599061赞成5东莞仁康医院有限公司张文辉18680068238赞成表15.3-4问卷个人基本情况统计项目人数百分率(%)知道8197.6是否知道该项目的建设不知道22.4有利8197.6本项目建设对当地经济、文化的影响一般11.2不清楚11.2污水排放11.2废气排放00噪声污染00认为本项目的主要环境影响表现在固废00无8298.8其他00有影响00认为本项目建设对周围环境的影响影响不大1821.7无影响6578.3满意7995.2是否满意本项目采取的环保措施不满意00不清楚44.8202 广东现代国际展览中心二期扩建工程环境影响报告书赞成83100是否同意本项目的建设反对00不关心00表15.3-5问卷单位基本情况统计项目人数百分率(%)知道3100是否知道该项目的建设不知道00有利3100本项目建设对当地经济、文化的影响一般00不清楚00污水排放00废气排放00噪声污染00认为本项目的主要环境影响表现在固废00无3100其他00有影响00认为本项目建设对周围环境的影响影响不大00无影响3100满意480是否满意本项目采取的环保措施不满意120不清楚00赞成3100是否同意本项目的建设反对00不关心00根据上表统计结果可以看出,被访公众中无人反对本项目的建设,100%的被访公众赞成;有21.7%的被访公众认为项目建设对周围环境影响不大,78.3%的被访公众认为建设项目对周围环境无影响。对于项目所采取的环保措施,95.2%的被访公众满意项目所采取的环保措施,4.8%的被访公众表示不清楚。五个被调查单位均对本项目的环保措施表示满意。建设单位表示将在未来工作中加强管理,进一步加强各项环境管理,确保各项污染物达标排放,及时根据周围公众的意见进行环保改进,减轻对周边居民及单位的影响。从调查结果来看,本评价认为:公众对项目建设的支持率很高,无反对意见,对该项目建设普遍持支持和肯定态度。公众对项目施工期的影响比较关心,因此,建设单位应做好施工期的环境保护,减少对周围环境的影响,特别是项目边界的居民区。同时应做好运营期的各种污染防治措施,将对周围环境的影响降到最低限度。203 广东现代国际展览中心二期扩建工程环境影响报告书第16章结论与建议16.1项目概况广东现代国际展览中心有限公司计划投资199187万元建设广东现代国际展览中心二期2扩建工程,选址位于东莞市厚街镇家具大道新塘路段。项目建筑占地面积64571m,总建筑222面积714839m,其中地上建筑面积522056m,地下建筑面积192783m。建设内容包括外博大厦、A、B区展览馆和C区停车场。外博大厦为超高层建筑,建筑物高达480m,其中地上部分102层;含裙楼4层,面积为16434平方米,功能为外博大厦的对外办公、服务等配套用房;其余各层为不同类型的办公空间,面积为245000平方米,每层标准层面积2700平方米;地下部分3层,功能为地下停车库。A、B区展览馆共6层,楼高37.8米,总建筑面积为260550平方米。一至六层为展览馆,展览馆地下一层为五金超市、停车库,地下二层为停车库,面积约为15万平方米,展览馆南北向长约为326米,东西向宽约为180米。C区停车场位于B区南端,负二层到四层为立体停车库。此外,项目在2南侧建设垃圾收集站一座,面积约为72m。本项目扩建完成后,将对原二期已建成的展览馆A馆进行拆除,改建为休闲广场。项目A区展览馆于2012年3月动工建设,目前基坑已开挖完毕,整体工程计划于2015年2月竣工,共计36个月。16.2建设项目周围环境质量现状东莞运河总体水质劣于III类,各监测点位均超标的项目有BOD5、氨氮、总氮,此外,厚街沙塘污水处理厂排污口处(1#)COD超标,水质相对较好;厚街沙塘污水处理厂出水纳污河流——东莞运河下游1000米处断面(2#)DO、COD、总磷、阴离子表面活性剂等项目均超出《地表水环境质量标准》的III类标准,水质较差;厚街沙塘污水处理厂排污口上游400米东莞运河与支流A交汇处断面(3#)DO、总磷超出《地表水环境质量标准》的III类标准。从超标倍数看,三个监测断面氨氮、总氮超标倍数在7.5-10.2之间,说明东莞运河在沙塘污水处理厂排污口上游400米至下游1000米范围内有机污染严重,水质较差。在监测时段内,SO2、NO2、PM10浓度达到《环境空气质量标准》(GB3095—2012)中的二级标准要求,项目区苯、二甲苯浓度能满足《工业企业设计卫生标准》中居住区大气204 广东现代国际展览中心二期扩建工程环境影响报告书中有害物质的最高容许浓度,甲苯浓度能满足“前苏联(1974)居住区大气中有害物最大允许浓度”;可见,本建设项目所在地周围的环境空气质量能够达到相应的功能区要求。项目地块北面、南面边界能满足《声环境质量标准》(GB3096-2008)中4a类标准,其余各监测点均超出《声环境质量标准》(GB3096-2008)中2类标准,其中地块西面边界昼间超标1.2~1.3dB(A)、夜间超标2.1~2.5dB(A),东面边界昼间超标8.9~9.5dB(A)、夜间超标4.7~4.8dB(A)。项目地块内昼间超标2.1~4.3dB(A)、夜间超标2.9~3.4dB(A)。项目地块周边较为开阔,东面省道S256部分道路封闭进行地铁R2线及穗莞深城际轨道施工,施工噪声和道路交通噪声对周边声环境影响较大。随着施工的结束、城市道路的畅通,区域声环境将得到改善。16.3建设期间的环境影响分析及污染防治措施16.3.1施工噪声施工期噪声污染源主要来自建筑施工机械噪声。本项目基础采用天然基础,不采用桩机基础。在主要施工机械同时运行且未采取任何降噪措施的情况下白天施工,土石方阶段约在70m以上距离可以达到《建筑施工场界环境噪声排放标准》,基础和结构阶段在80m以上距离可以达标,装修阶段约在70m以上距离可以达标;基础和结构阶段在夜间300m处仍不能达标,土石方、装修阶段夜间在300m以上距离才能达标。项目周边距离最近的敏感点距离约120m,项目施工阶段排放的噪声到敏感点约为64~67dB(A),会对敏感点声环境造成不利影响。施工期间应严格遵照《东莞市控制建筑施工噪声污染管理办法》对施工噪声管理的时限规定,防止噪声影响周围环境和人们的正常生产生活。(1)合理安排施工计划和施工机械设备组合以及施工时间,施工单位夜间施工应当确定合理的作业时间,连续运输、浇灌混凝土的夜间作业,一般一次不得超过2个昼夜,装卸其他建筑材料、土石方和建筑废料不得超过当日24点。施工机械的作业时间严格限制在6时至12时,14时至22时,原则上禁止夜间施工,严禁高噪声设备在休息时间(中午或夜间)作业。如施工期因工艺要求必须连夜作业时应得到有关部门批准,并公告附近居民;否则,不得违反“任何单位和个人不得在午间(北京时间12时到14时)和夜间(北京时间22时至翌日6时)在居民区、文教区、疗养区从事打桩、洗石、搅拌等影响居民休息的强噪声建筑施工205 广东现代国际展览中心二期扩建工程环境影响报告书作业”的规定。在施工过程中,尽量减少运行动力机械设备的数量,尽可能使动力机械设备均匀地使用。(2)对本项目的施工进行合理布局,尽量使高噪声的机械设备远离敏感点。(3)应严格执行《东莞市控制建筑施工噪声污染管理办法》,进行文明施工,建立健全现场噪声管理责任制,加强对施工人员的素质培养,尽量减少人为的大声喧哗,增强全体施工人员防噪声扰民的意识。(4)施工单位应该加强与附近单位和居民的沟通,施工时,应在建筑施工工地显著处悬挂建筑施工工地环保牌,注明工地环保负责人及工地现场电话号码,以便公众监督及沟通。(5)从控制声源和噪声传播以及加强管理等几个不同角度对施工噪声进行控制:控制声源;控制噪声传播;加强管理。(6)选择适当施工工艺。16.3.2施工扬尘项目施工扬尘主要来自于以下几个方面:(1)场地平整和地基处理中,将使用挖土机和推土机进行堆填,在砌块堆砌,沙土搬运、倾倒过程中将有少量土壤从地面、施工机械、土堆中飞扬进入空气;(2)原料堆场和暴露松散土壤的工作面,工作面表面多数为细小沙土,受风吹时,表面侵蚀随风飞扬进入空气;(3)物料运输过程中车辆在裸露地表上行驶时带起的扬尘,以及车上装载的物料碎屑飞扬进入空气。一般情况下,施工场地、施工道路在自然风作用下产生的扬尘所影响的范围在100m以内。如果在施工期实施每天洒水4-5次,可有效控制车辆扬尘,将TSP影响范围缩小到20-50m。施工期应按照《防治城市扬尘污染技术规范》HJ/T393-2007要求,采取下列措施对扬尘控制:打围施工。硬化道路。设置冲洗设备专用设施。湿法作业,施工场地干燥时适当喷水加湿,建筑施工风速四级以上时,拟暂停开挖,随洒水随清运垃圾,渣土要在3天内清运完毕。206 广东现代国际展览中心二期扩建工程环境影响报告书配齐保洁人员。项目施工场地配备专职的保洁人员负责施工现场卫生管理工作,配备洒水设备。定时清扫现场,选择对周围环境影响较小的运输路线,定时对运输线路进行清扫。在室内装修过程中尽量不要使用含有汞类、醛类、卤化物溶剂或者芳香族化合物等一些对人体影响很大、会造成人体健康损害的污染物,不使用铅、铬、镉等金属及其化合物的颜料和添加剂。施工期须严格遵守各项规定的要求,对扬尘进行治理,以确保施工扬尘不对周边大气环境质量造成污染影响,达到保护环境,保障身心健康的目的。16.3.3施工废水项目在施工期产生的废水包括施工人员生活污水和施工废水。施工人员不在施工现场食宿,施工期间施工人员生活污水主要来源于如厕和清洗废水,废水若直接排放将对地表水体产生不良影响。施工废水主要来自于施工机械设备和运输车辆的定期清洗,包括开挖和钻孔产生的泥浆水、机械设备运转的冷却水和洗涤水、混凝土搅拌车及输送系统冲洗废水、车辆清洗水,以及开挖基础时为降低地下水位的抽排水和工程开挖过程中可能产生的地下涌水等,施工废水中主要污染物为石油类和SS,悬浮物浓度达到1500~2000mg/L,如直接排放,会在一定程度上增加地表水污染负荷。项目可设置简易隔油沉淀池等措施对施工废水进行处理,处理后可回用于浇洒路面、车辆冲洗等,回用后余下的排入市政污水管道,对地表水环境影响很小。本报告建议项目设置化粪池对生活污水进行预处理,将预处理后生活污水接入项目北侧家具大道、南侧会展南路地下污水管道,排入东莞市厚街沙塘污水处理厂,对项目所在区域水环境影响较小。项目施工期开挖地下室时为降低地下水位抽排地下水,开挖过程中也可能产生一定的地下涌水。项目合理安排施工时间,基础施工尽量避开地下水的丰水期,尽可能在枯水期进行抽排地下水,这样会大大的减少地下水抽排量,抽排后立即进行封堵;项目在开挖过程中及时进行基坑侧壁止水,涌水产生量较小。因此,项目基础开挖基本不会造成项目所在区域地下水位降低。16.3.4固体废弃物施工期间产生的固体废物主要包括弃土方和建筑垃圾,以及少量施工人员生活垃圾。207 广东现代国际展览中心二期扩建工程环境影响报告书固体废物主要处理措施包括:(1)建设单位或者施工单位对产生的建筑垃圾应当按照有关规定设置围挡,做到施工出入口硬化铺装并配备相应的冲洗设施,及时督促经核准的运输单位及时运输,保持工地和周边环境整洁。(2)建筑垃圾运输车应当按照有关规定设置密封式加盖装置并实施完全密闭式运输;建筑垃圾装载量不得超过车厢挡板;在驶离建筑工地前,车体应在建筑工地围护栏内冲洗干净;建筑垃圾运输车按规定的时间和路线行驶。(3)单位和个人因装饰装修房屋产生的建筑垃圾,应当按照物业管理企业或者街道办事处指定地点临时堆放,并采取措施围挡、苫盖,并在12小时内委托他人或者自行运输。运输应当采用袋装或者密闭的方式,防止途中洒落,在市城管部门指定的地点倾倒。(4)建设单位或者施工单位应当逐步实施建筑垃圾分类收集,最大限度地实现建筑垃圾资源化回收利用。对已经产生的建筑垃圾,应当争取就地处理、就地使用,尽量减少建筑垃圾的排放。对不能就地处理、就地使用的建筑垃圾,应当根据其建筑垃圾的类别运输至市主管部门指定的地点或者向综合利用企业交售。(5)建筑垃圾排放、运输、中转、回填、受纳实行联单和统计表制度。(6)对于如废油漆、废涂料及其内包装物等,属于危险废物,必须严格执行危险废物管理规定,由专人、专用容器进行收集,并定期交送有资质的专业部门处置。(7)对于施工工人的驻地,设立垃圾收集装置,并定期清运。对于施工现场施工人员活动产生的分散垃圾,除对施工人员加强环境保护教育外,也应设立一些分散的小型垃圾收集器(如废物箱),并派专人定时打扫清理,施工期少量的危险废物交有资质的部门处理。(8)施工单位必须严格执行余泥渣土排放管理的有关规定,按规定办理好余泥渣土排放的手续,获得批准后方可在指定的受纳地点弃土。(9)运输车辆必须按照指定的运输路线和时间行驶,运输过程中应装载适量,车厢上部必须覆盖篷布或采取其他有效措施,防治余泥渣土沿途洒漏、飞扬。运输余泥渣土的车辆驶离建设工地时,建设或施工单位应冲洗车体,保持车辆整洁。(10)建设过程中应加强管理,文明施工,使建设期间对周围环境的影响减少到较低限度,做到发展与保护环境相协调。208 广东现代国际展览中心二期扩建工程环境影响报告书16.4项目运营期环境影响分析及污染防治措施16.4.1水环境影响分析及污染防治措施3项目所排污水主要为生活污水,外排污水量为1447.1m/d。废水中主要污染物CODcr、BOD5、SS、NH3-N等。建设项目生活污水经三级化粪池预处理后达到《水污染物排放限值》(DB44/26-2001)第二时段三级标准后,排入城市污水管网,进入东莞市厚街沙塘污水处理厂经过二级生化处理后污染物浓度进一步降低,达到《城镇污水处理厂污染物排放标准》(GB18918-2002)一类B标准后排放,对东莞运河影响较小。化粪池、污水输送管道、污水收集池等做好充分的防渗处理,可以确保项目运营期项目各类污水及受污染的初期雨水不会下渗影响地下水质,本项目对地下水环境影响甚微。16.4.2环境空气影响分析及污染防治措施项目竣工投入使用后,其废气污染源有:机动车尾气、发电机尾气、垃圾站臭气等,对周围环境造成影响的主要污染物为SO2、NOx及臭气等。备用发电机尾气中SO2、NOx和烟尘经处理后可以达标排放;机动车进入车库时排放的尾气为无组织排放,采取通风措施后可以得到控制。项目采取措施控制废气污染源,其措施如下:(1)项目设有地下停车场,地下停车场设有抽风排气系统,保证地下车库的换气次数(6次/小时),并收集车库废气由绿地中间排出,机动车尾气不会在车库累积,不会对周围环境产生明显不良影响。另外,区内多设置树木、草坪,扩大绿地面积,增大绿地功能,改善生态,减少机动车尾气的影响。(2)项目备用发电机燃油尾气通过水喷淋(添加碱液)处理后由专用排气筒高空排放。(3)在垃圾收集站附近增加绿化设施,加强对垃圾站的管理,并对臭气采取适当的处理,如生物处理后引入绿化带排放。(4)在项目内加强绿化工作,以防治废气的污染。209 广东现代国际展览中心二期扩建工程环境影响报告书16.4.3声影响源分析及污染防治措施运营期项目主要噪声源有备用发电机组、冷水机组、水泵、风机等,除柴油发电机的工作噪声为100~105dB(A)外,其余设备的噪声级均在85dB(A)以下。机房设备噪声经过机房墙壁和地下室墙壁的阻隔以及空间距离的衰减后,到达地面时,冷水机组、水泵、风机等噪声基本可达到夜间2类标准,而备用发电机房噪声将超过夜间2类标准14.8dB(A)。冷却塔距西边界的最近距离为45米,在西边界冷却塔噪声超过《声环境质量标准》(GB3096-2008)中2类标准,另外,根据声环境现状监测结果来看,本项目用地区域声环境质量已经超标,因此,建议本项目对冷却塔进一步采取隔声措施,如设置隔声屏等措施,最大限度地降低冷却塔噪声。本项目冷却塔距西边界的最近距离为65米,在西边界冷却塔噪声超过现状值昼间约为3分贝,昼间高达9.2分贝。另外,根据声环境现状监测结果来看,本项目用地区域声环境质量已经超标,因此,建议本项目对冷却塔进一步采取隔声措施,如设置隔声屏等措施,最大限度地降低冷却塔噪声。本项目周边最近的声环境敏感点仁康医院住院部、华庭花园酒店、溪头村居民楼距本项目南面边界的距离约120米,从表7.3-4预测结果看出,本项目冷却塔噪声到达该敏感点时小于43.3分贝,影响较小,而且本项目冷却塔在采取了隔声降噪措施后,进一步降低噪声,因此,本项目冷却塔在采取了有效地隔声降噪措施后,对华庭花园酒店、仁康医院住院部、溪头村居民楼不会产生影响。为了减小机械设备噪声的影响,项目拟采取以下措施:(1)将水泵、风机、配电房等置于地下室专用设备房内,设备均应选用低噪低振机型,并采取隔声、消声、吸声及减振等综合措施。(2)柴油发电机拟采用的措施:柴油发电机房全封闭处理,采用隔声门,并在建筑上做隔音吸音处理;采用双层隔声通风采光窗,设备基础加减震措施;室内强制通风,采用低噪声风机,进、出风口安装消声器。(3)从冷却塔选型、风机排风口等进行控制,加强消声、隔声等降噪效果。根据预测结果可知,本项目展览馆A区设置的冷却塔在西边的边界处的噪声排放量较大,超过标准值,因此,本项目应对展览馆A区设置的冷却塔应设置隔声屏障,要求隔声效果达到8分贝以上,以降低项目噪声在边界处与现状噪声的叠加效果。隔声屏的位置应在冷却塔的外围距离冷却210 广东现代国际展览中心二期扩建工程环境影响报告书塔的边缘5m以内,高度应比冷却塔高出1m,建议把整个冷却塔区域围合起来进行设计,其周长大约为135m。(4)在区内周围道路两旁植树绿化,设置隔声带,以减少道路交通噪声对区内声环境干扰。16.4.4固体废弃物影响分析及污染防治措施本项目运行期间产生的固体废物主要包括:办公垃圾、商业垃圾、废旧电池(属于危险废物)等。只要采取严格有效的管理措施,本项目运营期的生活垃圾不会对周围环境造成危害。另外,办公和商业垃圾中的废干电池、充电电池、含汞灯具等属于危险废物,如果收集、运送不当会对周围环境造成一定影响,也会影响本区域建成后的生活环境质量和城市景观。项目拟采取的固体废物收集与处置措施如下:(1)对办公垃圾、商业垃圾,由物业管理部配专人清扫。(2)对生活垃圾日产日清,不隔夜堆放。将收集的生活垃圾统一交东莞市厚街镇环卫部门清运至垃圾处理厂,统一集中处置。(3)设立专门的危险废物收集点,让办公人员将危险废物主动交给危险废物管理处,收集后的危险废物应及时交给有资质的单位回收。16.4.5高楼风影响分析及防范措施外博大厦塔楼高480米,裙楼高24米,底部裙楼长约70米的,高度大,但长度和深度小,涡流区相对较小。地下车库排风口若设在涡流区内,不利于污染物扩散,周边污染物浓度有可能超标。项目外博大厦的裙楼为横长形,裙楼顶将成为风速最大区;塔楼为细高状,塔楼两侧将形成风速最大区。项目高楼风的影响主要表现:①本项目安装有玻璃幕墙,如果玻璃幕墙安装质量达不到能抗御高楼风的要求,则可能会导致玻璃幕墙中的玻璃坠落事件,也将对周边人群的人身和财产安全构成威胁。②高楼风导致地面风速过大,影响车辆和行人安全。因此,在项目设计时应重点和充分考虑高楼风对周边环境的影响,力争将影响降到最低。项目外博大厦塔楼呈细高状,风速最大区位于建筑211 广东现代国际展览中心二期扩建工程环境影响报告书物两侧,项目应进行风洞实验确定建筑物的实际风荷载,并在下一步结构设计中进行相应的抗风荷载设计。项目本身受风场的影响主要表现在台风状况下,由于楼体较高,承受的风负荷很大,并由此引起结构和流体的藕合振荡,从而危急建筑物的安全。根据有关记录,部分高楼幕墙受台风影响出现雪崩似的现象,造成了严重事故,因此,建议加强本项目幕墙的结构设计和抗风强度检验,杜绝意外事故发生。为此,项目应采取防治高楼风的措施:(1)重视项目裙楼、种植高大乔木以及围墙拱廊等遮挡物对高速气流的剥离作用。户外广告牌、玻璃幕墙和建筑物外装饰等应委托专业的有资质的单位按照国家规范施工建设,确保在台风等强风状态下的安全。(2)地下停车场排风口、备用发电机的废气排放口不要设在超高层建筑的背后涡流区内,以防大气污染物不易扩散而造成大气污染物超标。16.4.6光污染影响分析及污染防治措施(1)玻璃幕墙光污染分析及污染防治措施本项目塔楼外墙以玻璃幕墙为主,适当地辅以具装饰性及功能性的外墙构件;裙房外墙采用石材,无玻璃幕墙。本项目周边有北面的居民楼和办公楼,夏天,如玻璃幕墙强烈光反射光进入居民楼或办公楼内,这些额外的辐射热将提高室内温度,影响居民的正常生活。本项目的玻璃幕墙为低辐射镀膜夹层玻璃,不会形成聚集点,但是面对居民楼或办公楼的玻璃幕墙的强烈的反射光会一定程度地升高室内的温度,且强光照也将对楼内居民的正常生活造成一定的影响。根据《玻璃幕墙工程技术规范》(JGJ102-2003)中规定,为限制玻璃幕墙光污染,本项目外立面玻璃幕墙应采用反射比不大于0.30的玻璃,宜选用柔和中性的色彩。本项目各建筑物20m高度以下的玻璃幕墙应该用反射率小于12%的低反射玻璃。并根据各种玻璃幕墙的使用寿命,定期进行检验,及时返修或更换。不锈钢及铝合金饰面材料选购时,也应注意选择反射率低的材料。在设计时考虑反射角度尽量减少对周边住户与办公楼以及周边道路的光污染。在建筑物高度10m~30m以下位置,应根据实际情况不使用玻璃幕墙。(2)灯光污染分析及污染防治措施212 广东现代国际展览中心二期扩建工程环境影响报告书本项目如果夜间用灯光展现建筑物的景观,如果设计不当,有可能会对周边的仁康医院住院部、华庭花园酒店、溪头村居民楼造成人工白昼污染,对此本项目必须高度重视。①控制本项目环境照明和装饰性灯具光线的出射方向,使之不能直接照射到居民住宅的窗户上。②在设计本项目室外照明时,充分考虑灯具的安装位置,尽量避免将灯具安装在居民住宅一侧。③在满足照明要求的前提下,减小灯具功率。④采取照明控制手段,在不需要照明的时候将照明设备关闭。控制环境照明和景观照明的时间,尽可能的缩短夜间照明时间。⑤使用对周围动植物影响最小的光源。如对昆虫吸引力最大的是荧光高压汞灯,较小的是低压钠灯和高压钠灯。所以在有居民和游客逗留的城市休闲区的照明设计中也应尽量避免使用荧光高压汞灯,以免引来不受人欢迎的昆虫。16.4.7对区域交通影响分析及交通改善措施项目对区域交通产生的影响显著,主要表现如下:(1)对外部交通的影响较大,交通拥挤已经蔓延到博览快速等区域干道并产生显著影响;影响最为显著的莞太路—家具大道路口;(2)内部交通功能与规模不足,主要表现在交通功能散漫,对行人集散、出租车临时停靠、公交临时增线、酒店巴士临时停靠等考虑不足,需统筹布局交通集散功能区域。(3)交通组织不完善,使得出入口及内部交通冲突与交织较多,部分地下车库出入口交通压力较大,交通蔓延出项目区域进而影响到周边道路设施。同时项目步行交通较多,欠缺与周边设施的行人通道,并影响道路机动交通效率,特别是与穗莞深城际轨道交通的距离较远、关联性弱,不利于发挥轨道交通对展览中心的服务能力。《广东现代国际展览中心设计方案交通影响评价》提出了外部交通改善和内部交通改善两个层面的建议。内部交通改善措施包括项目内部交通单向组织、优化地下车库出入口、增设交通集散中心等;外部交通包括行人设施、公交设施、区域道路、周边道路等方面的改善。本报告建议对于项目建设造成的区域交通堵塞问题,需要由市规划管理部门应统筹规划,统一解决。16.5外环境污染源对本项目的影响分析及污染防治措施现状监测时,项目位于下风向,根据现状监测结果,项目区SO2、NO2、PM10浓度达到《环境空气质量标准》(GB3095—2012)中的二级标准要求,苯、二甲苯浓度能满足《工213 广东现代国际展览中心二期扩建工程环境影响报告书业企业设计卫生标准》中居住区大气中有害物质的最高容许浓度。可见,周边工业大气污染源对本项目的影响较小。在受周边道路交通噪声的影响下,外博大厦夜间超标量较大,最大超标17.42dB(A),昼间最大超标10.07dB(A);但与现状监测结果对比,昼间超出现状仅为1.27dB(A),夜间超出现状值较大,约13.22dB(A)。随着车流量的显著增加,外博大厦受周边交通噪声的影响增大。类比一般城市规划主干道汽车尾气排放情况,主干道在达到设计车流量后,汽车3行驶过程中排放的NO2一次浓度最大值为0.26mg/m,占标率为130%;CO一次浓度最大3值为2.19mg/m,占标率为21.9%,最大落地出现在距离道路中心线30米的地方,本项目与家具大道最近距离为90米,可以看出,家具大道行驶车辆排放的汽车尾气可能对项目产生一定影响。地铁R2线离项目地最近的站点为厚街展览中心站,从项目地块东侧(现状省道S256)地下通过,与外博大厦最近距离为380m。穗莞深城际轨道从项目地块南侧地下通过,并在仁康医院南侧设厚街站(地下站),与外博大厦最近距离为570m。可见,运营期受地铁R2线、穗莞深城际轨道噪声、振动影响较小。外环境污染防治措施:(1)根据项目特点确定合理的绿化方案,综合运用各种绿化方式和风景园林艺术手法,充分利用自然条件,精心组织景观序列。(2)绿化地段应避免物种单一化,选择适合当地环境的树种。建立观赏型、环境保护型、保健型的多种人工植物群落,尽量做到有疏有密、多层次化,同时充分利用有限的绿色空间,增加绿色的厚度和气氛,给人们带来明显的环境效益和社会效益。(3)充分利用有限空间。绿化形式应重点考虑立体绿化,增加绿化层次结构。16.6规划相符性及选址合理性分析对照《产业结构调整指导目录(2011年本)》、《广东省产业结构调整指导目录(2007年本)》、《东莞市产业导向目录(2008年本)》,会展场馆的建设不在目录中的淘汰、限制类,项目建成后提供会展服务,属于其中的鼓励类,故项目建设符合国家、广东省及东莞市产业政策。214 广东现代国际展览中心二期扩建工程环境影响报告书项目用地符合《东莞市厚街镇会展片区控制性详细规划》,符合《广东省环境保护规划纲要(2006-2020年)》、《广东省环境保护条例》、《珠江三角洲环境保护规划纲要》(2004-2020年)》等国家供地政策。项目所在区域大气环境为二类功能区,声环境为2类功能区,地表水为III类功能区。项目建设不会改变功能区现状,因此项目选址符合环境功能区划要求。核查《东莞市厚街镇会展片区控制性详细规划》和本项目经济技术指标,项目各项指标均能满足《东莞市厚街镇会展片区控制性详细规划》F04-03地块的要求,仅绿地率低于20%,因此,建议建设单位根据项目实际情况规划绿地面积,尽可能达到《东莞市厚街镇会展片区控制性详细规划》的要求,并充分利用空间进行绿化,以增加用地内的绿化率。16.7公众参与本次调查共发放问卷92份,回收88份(个人83份,单位5份),回收率为95.7%。受调查人员和参与调查对象、单位100%在项目环境影响评价范围内。从统计结果可知,被访公众中无人反对本项目的建设,100%的被访公众赞成;有21.7%的被访公众认为项目建设对周围环境影响不大,78.3%的被访公众认为建设项目对周围环境无影响。对于项目所采取的环保措施,95.2%的被访公众满意项目所采取的环保措施,4.8%的被访公众表示不清楚。5个被访单位均对本项目的环保措施表示满意。建设单位表示将在未来工作中加强管理,进一步加强各项环境管理,确保各项污染物达标排放,及时根据周围公众的意见进行环保改进,减轻对周边居民及单位的影响。从调查结果来看,本评价认为:公众对项目建设的支持率很高,无反对意见。公众对项目的建设施工期的影响比较关心,因此,建设单位应做好施工期的环境保护,减少对周围环境的影响,特别是项目边界的居民区。同时应做好运营期的各种污染防治措施,将对周围环境的影响降到最低限度。16.8清洁生产水平本项目在总体规划设计中,通过合理采用建筑及装饰材料,并采取一系列的节能措施,将会营造一个良好的生活环境,减少能源的消耗,降低污染物的产生和排放量,更好的保护了环境。在项目建设施工过程中从水、气、声、固废等四方面采取一系列控制措施确保项目在施工建设期间做到清洁生产。因此,该项目的建设符合清洁生产的要求。215 广东现代国际展览中心二期扩建工程环境影响报告书16.9总量控制指标根据建设单位提供的资料,通过预测计算,该项目各种污染物的排放达到国家和地方排放标准限值要求的前提下,其影响是可以接受的。为减少对周围环境的影响,建设单位应严格控制其污染物的排放,使其污染物排放控制在合理的、环境允许的污染物排放量之内。由于本项目各类废水最终均排入东莞市厚街镇沙塘污水处理厂,因此,本项目废水及CODcr、氨氮无需向环保部门申请排放总量控制指标,由于本项目NOX排放量较小,可由环保审批部门直接审批。16.10环境经济损益分析项目具有较好的市场前景,可以投资开发。项目将会带来较好的经济效益,是一项较好的投资项目。项目由于规模大、投资大、工期长等,可能存在一定的投资风险,需要在工程管理和经营管理等方面进行努力,在控制成本的同时保证建筑质量,进一步降低风险。项目环保投资1147万元,占总投资的0.6%,环保投资基本合理。16.11风险评价本项目为超高层建筑,地处建成区,项目运营期存在很多安全隐患,如风对高层、超高层建筑影响,玻璃幕墙风险,火灾与恐怖袭击等。这些事故中,超高层建筑火灾风险防范为重中之重。项目环境风险主要是人为事件,完全可以通过政府各有关职能部门加强监督指导,企业内部制定严格的管理条例和岗位责任制,加强职工的安全生产教育,提高风险意识,能够最大限度地减少可能发生的环境风险。在加强管理的前提下,使得本环境风险降至最低。16.12总结论本项目用地性质为会展用地。项目建设符合国家产业政策,符合城市规划和《东莞市厚街镇会展片区控制性详细规划》的相关规定。项目对周边环境的影响主要来自于施工期的扬尘与施工噪声,以及运营期的冷却塔噪声、厨房油烟等。根据预测结果,本项目建设对周边环境的影响范围和程度较小。本项目的环境影响在严格执行本评价提出的环境保护措施与污216 广东现代国际展览中心二期扩建工程环境影响报告书染综合防治对策的前提下是可以接受的。综上所述,本项目的选址和建设从环境保护的角度来讲是可行的。16.13建议项目绿地率低于20%,建议建设单位根据项目实际情况规划绿地面积,尽可能达到《东莞市厚街镇会展片区控制性详细规划》的要求,并充分利用空间进行绿化,以增加用地内的绿化率。217'

您可能关注的文档