• 492.50 KB
  • 16页

涉外工程苏丹某大学室外配套项目(含停车场)工程量清单(含全套图纸)

  • 16页
  • 当前文档由用户上传发布,收益归属用户
  1. 1、本文档共5页,可阅读全部内容。
  2. 2、本文档内容版权归属内容提供方,所产生的收益全部归内容提供方所有。如果您对本文有版权争议,可选择认领,认领后既往收益都归您。
  3. 3、本文档由用户上传,本站不保证质量和数量令人满意,可能有诸多瑕疵,付费之前,请仔细先通过免费阅读内容等途径辨别内容交易风险。如存在严重挂羊头卖狗肉之情形,可联系本站下载客服投诉处理。
  4. 文档侵权举报电话:19940600175。
'MEDICALFACULTIESCOMPLEXBILLSOFQUANTITIESAMARCONSULTBUILDINGNAME:MASTERPLANBILLSOFQUANTITIESFORELECTRICALWORKSATORIESCOLLEGEITEMNO.DESCRIPTIONUNITQTYRATEAMOUNT(SD)1MAINPOWERDISTRIBUTIONSYSTEMSupply,install,connect,test&commissionthefollowingelectricalworksasspecified&shownonthedrawings,&includingallfixingmaterials,supportingstructures,bolts&nuts,consumables..etcalluptothesatisfactionoftheEngineer1-1FACULTYOFDENTISTRY(DS)FEDFROMPOWERHOUSE(1)1-1-1MainSwitchboardBoard-MSB-DSSet11-1-2PowerCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx630mm2,CU,XLPE/AWA/PVCML9001cx500mm2,CU,XLPE/AWA/PVCML9001-1-3EarthingCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx630mm2,CU,PVC/PVCML1301cx500mm2,CU,PVC/PVCML1301-1-4250KvarPowerFactorCorrectionEquipmentSet11-1-5EarthingPits&mainearthingleads:-worktoincludedrivingofearthingrods,testing&constructionofearthpitsmanholesEarthingpitsNo1Earthingrods-NB:-Numberofrodsdependsonthesoilcharacteristics.No14Earthingbusbar1250ampsrated,60cmlength,oninsulatorssupportNo1Heavydutymanholecover(45x45cm)No1TOTALCARRIEDTOSUMMARY1-2LIBRARY(LI)FEDFROMPOWERHOUSE(1)1.2.1MainSwitchboardBoard-MSB-LMSSet11.2.2PowerCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx500mm2,CU,XLPE/AWA/PVCML7004cx185mm2,CU,XLPE/SWA/PVCML2001.2.3EarthingCables.Includingsupplyof(16) MEDICALFACULTIESCOMPLEXBILLSOFQUANTITIESAMARCONSULTBUILDINGNAME:MASTERPLANBILLSOFQUANTITIESFORELECTRICALWORKSATORIESCOLLEGEglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx500mm2,CU,PVC/PVCML1001cx185mm2,CU,PVC/PVCML1001.2.4150KvarPowerFactorCorrectionEquipmentSet11.2.5EarthingPits&mainearthingleads:-worktoincludedrivingofearthingrods,testing&constructionofearthpitsmanholesEarthingpitsNo1Earthingrods-NB:-Numberofrodsdependsonthesoilcharacteristics.No14Earthingbusbar800ampsrated,60cmlength,oninsulatorssupportNo1Heavydutymanholecover(45x45cm)No1TOTALCARRIEDTOSUMMARY1.3.FACULTYOFMEDICALLABORATORIES(ML)FEDFROMPOWERHOUSE(1)1.3.1MainSwitchboardBoard-MSB-MLSet11.3.2PowerCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx630mm2,CU,XLPE/AWA/PVCML16001cx500mm2,CU,XLPE/AWA/PVCML16001.3.3EarthingCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx630mm2,CU,PVC/PVCML2501cx500mm2,CU,PVC/PVCML2501.3.4250KvarPowerFactorCorrectionEquipmentSet11.3.5EarthingPits&mainearthingleads:-worktoincludedrivingofearthingrods,testing&constructionofearthpitsmanholesEarthingpitsNo1Earthingrods-NB:-Numberofrodsdependsonthesoilcharacteristics.No14Earthingbusbar1250ampsrated,60cmlength,oninsulatorssupportNo1(16) MEDICALFACULTIESCOMPLEXBILLSOFQUANTITIESAMARCONSULTBUILDINGNAME:MASTERPLANBILLSOFQUANTITIESFORELECTRICALWORKSATORIESCOLLEGEHeavydutymanholecover(45x45cm)No1TOTALCARRIEDTOSUMMARY1.4.DIAGNOSTICCENTREFEDFROMPOWERHOUSE(1)1.4.1MainSwitchboardBoard-MSB-DNSet11.4.2MainPowerDistributionBoard-MDB-EQSet11.4.3PowerCables.Includingsupplyofglands&lugs-NBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx500mm2,CU,XLPE/AWA/PVCML17004cx240mm2,CU,XLPE/SWA/PVCML10004cx120mm2,CU,XLPE/SWA/PVCML5001.4.4EarthingCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx500mm2,CU,PVC/PVCML2501cx240mm2,CU,PVC/PVCML5001cx120mm2,CU,PVC/PVCML2501.4.5250KvarPowerFactorCorrectionEquipmentSet11.4.6EarthingPits&mainearthingleads:-worktoincludedrivingofearthingrods,testing&constructionofearthpitsmanholesEarthingpitsNo1Earthingrods-NB:-Numberofrodsdependsonthesoilcharacteristics.No14Earthingbusbar1250ampsrated,60cmlength,oninsulatorssupportNo1Heavydutymanholecover(45x45cm)No1TOTALCARRIEDTOSUMMARY1.5.MOSQUE(MQ)FEDFROMLIBRARY1.5.1PowerCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite4cx70mm2,CU,XLPE/SWA/PVCML6601.5.2EarthingCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite(16) MEDICALFACULTIESCOMPLEXBILLSOFQUANTITIESAMARCONSULTBUILDINGNAME:MASTERPLANBILLSOFQUANTITIESFORELECTRICALWORKSATORIESCOLLEGE1cx70mm2,CU,PVC/PVCML2201cx35mm2,CU,PVC/PVCML2201.5.3EarthingPits&mainearthingleads:-worktoincludedrivingofearthingrods,testing&constructionofearthpitsmanholesEarthingpitsNo1Earthingrods-NB:-Numberofrodsdependsonthesoilcharacteristics.No14Earthingbusbar100ampsrated,60cmlength,oninsulatorssupportNo1Heavydutymanholecover(45x45cm)No1TOTALCARRIEDTOSUMMARY1.6.SPINEENTRANCE(SP)FEDFROMLIBRARY1.6.1PowerCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite4cx120mm2,CU,XLPE/SWA/PVCML6004cx150mm2,CU,XLPE/SWA/PVCML3001.6.2EarthingCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequired.NBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx500mm2,CU,PVC/PVCML3001cx185mm2,CU,PVC/PVCML3001.6.3EarthingPits&mainearthingleads:-worktoincludedrivingofearthingrods,testing&constructionofearthpitsmanholesEarthingpitsNo1Earthingrods-NB:-Numberofrodsdependsonthesoilcharacteristics.No14Earthingbusbar200ampsrated,60cmlength,oninsulatorssupportNo1Heavydutymanholecover(45x45cm)No1TOTALCARRIEDTOSUMMARY1.7.FACULTYOFPHARMACOLOGY(PH)FEDFROMPOWERHOUSE(2)1.7.1MainSwitchboardBoard-MSB-PHSet11.7.2PowerCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx630mm2,CU,XLPE/AWA/PVCML1400(16) MEDICALFACULTIESCOMPLEXBILLSOFQUANTITIESAMARCONSULTBUILDINGNAME:MASTERPLANBILLSOFQUANTITIESFORELECTRICALWORKSATORIESCOLLEGE1cx500mm2,CU,XLPE/AWA/PVCML14001.7.3EarthingCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx630mm2,CU,PVC/PVCML2001cx500mm2,CU,PVC/PVCML2001.7.4250KvarPowerFactorCorrectionEquipmentSet11.7.5EarthingPits&mainearthingleads:-worktoincludedrivingofearthingrods,testing&constructionofearthpitsmanholesEarthingpitsNo1Earthingrods-NB:-Numberofrodsdependsonthesoilcharacteristics.No14Earthingbusbar1250ampsrated,60cmlength,oninsulatorssupportNo1Heavydutymanholecover(45x45cm)No1TOTALCARRIEDTOSUMMARY1.8.CAFTERIA(CF)FEDFROMPOWERHOUSE(2)1.8.1MainSwitchboardBoard-MSB-CF-CNSet11.8.2PowerCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx500mm2,CU,XLPE/AWA/PVCML7004cx185mm2,CU,XLPE/AWA/PVCML2001.8.3EarthingCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx500mm2,CU,PVC/PVCML1001cx185mm2,CU,PVC/PVCML1001.8.4150KvarPowerFactorCorrectionEquipmentSet11.8.5EarthingPits&mainearthingleads:-worktoincludedrivingofearthingrods,testing&constructionofearthpitsmanholesEarthingpitsNo1Earthingrods-NB:-Numberofrodsdependsonthesoilcharacteristics.No14Earthingbusbar600ampsrated,60cm(16) MEDICALFACULTIESCOMPLEXBILLSOFQUANTITIESAMARCONSULTBUILDINGNAME:MASTERPLANBILLSOFQUANTITIESFORELECTRICALWORKSATORIESCOLLEGElength,oninsulatorssupportNo1Heavydutymanholecover(45x45cm)No1TOTALCARRIEDTOSUMMARY1.9.FACULTYOFRADIOLOGY(RD)FEDFROMPOWERHOUSE(2)1.9.1MainSwitchboardBoard-MSB-RDSet11.9.2PowerCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx630mm2,CU,XLPE/AWA/PVCML21001cx500mm2,CU,XLPE/AWA/PVCML21001.9.3EarthingCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx630mm2,CU,PVC/PVCML3001cx500mm2,CU,PVC/PVCML3001.9.4250KvarPowerFactorCorrectionEquipmentSet11.9.5EarthingPits&mainearthingleads:-worktoincludedrivingofearthingrods,testing&constructionofearthpitsmanholesEarthingpitsNo1Earthingrods-NB:-Numberofrodsdependsonthesoilcharacteristics.No14Earthingbusbar1250ampsrated,60cmlength,oninsulatorssupportNo1Heavydutymanholecover(45x45cm)No1TOTALCARRIEDTOSUMMARY2CABLETRENCHESWORKSWorktoincludeexcavation,constructionoftrenches&bendingmanholesbrickwalls,sandbackfilling,pre-casting&fixingofconcretetilesfortrenchcover&layingofappropriatenumber&sizesofpipesunderroadcrossing,allasrequired&infullcoordinationwithallotherundergroundservices&specifiedsitelevels.Thecontractorshallsubmitforapprovalexecutiondrawingsincludingalldetailsrelativetotrenchesrouting,levels,roadcrossings,sections,cablelayingarrangement…etcasrequiredbytheEngineer(16) MEDICALFACULTIESCOMPLEXBILLSOFQUANTITIESAMARCONSULTBUILDINGNAME:MASTERPLANBILLSOFQUANTITIESFORELECTRICALWORKSATORIESCOLLEGENBTrenchSectiondimensionsareinsidedimensions2.1CABLETRENCHESFROMPOWERHOUSE(1)TrenchSection-A-(W1500×D90mm)ML100TrenchSection-B-(W1200×D90mm)ML110TrenchSection-C-(W100×D90mm)ML205TrenchSection-F-(W80×D60mm)ML40TrenchSection-G-(W60×D60mm)ML70TOTALCARRIEDTOSUMMARY2.2CABLETRENCHESFROMPOWERHOUSE(2)TrenchSection-A-(W1500×D90mm)ML60TrenchSection-B-(W1200×D90mm)ML150TrenchSection-C-(W100×D90mm)ML200TOTALCARRIEDTOSUMMARY3MAINPOWERDISTRIBUTIONSYSTEMFROMPOWERHOUSE(1)3.1TOTALOFDENTISTRY3.2TOTALOFLIBRARY3.3TOTALOFMEDICALLABORATORIES3.4TOTALOFDIAGNOSTICCENTRE3.5TOTALOFMOSQUE3.6TOTALOFSPINEENTRANCE3.7TOTALOFCABLETRENCHESWORKSOFPOWERHOUSE(1)TOCOLLECTIONTOTALCARRIEDTOSUMMARY4MAINPOWERDISTRIBUTIONSYSTEMFROMPOWERHOUSE(2)4.1TOTALOFPHARMACOLOGY4.2TOTALOFCAFTERIA4.3TOTALOFRADIOLOGY4.4TOTALOFCABLETRENCHESWORKSOFPOWERHOUSE(2)TOCOLLECTIONTOTALCARRIEDTOSUMMARY5OUTDOORLIGHTINGSYSTEMWORKSSupply,install,connect,test&commissionthefollowingelectricalworksasspecified&shownonthedrawings,&includingallaccessories..etcalluptothesatisfactionoftheEngineer5.1SERVICEBUILDINGSELECTRICAL(16) MEDICALFACULTIESCOMPLEXBILLSOFQUANTITIESAMARCONSULTBUILDINGNAME:MASTERPLANBILLSOFQUANTITIESFORELECTRICALWORKSATORIESCOLLEGEWORKS5.1.1Electricalpoints-,worktoincludelayingofconduit,installationofboxes&wiringfromthedistributionboarduptothepointandwireterminationcompletewithallnecessaryaccessories:-Lightingpoint(wiringuptotheswitch)No110ExhaustfanpointNo8Socket-outletpointNo60CeilingfanpointNo12ACunitsocket-outletpointNo65.1.2LightingFixturesworktoinclude,fixingoffixturesandwireterminationcompletewithallnecessaryaccessories:-2×18wweatherproofsurfacemountedfluorescentfixturewithdiffuserNo452×36wweatherproofsurfacemountedfluorescentfixturewithdiffuserNo655.1.3ElectricalDevicesworktoinclude,fixingofdevices&wireterminationcompletewithallnecessaryaccessories:-10A,1-gang,1-waylightingswitchNo1210A,2-gang,1-waylightingswitchNo1210A,1-gang,2-waylightingswitchNo610/16A,2-pinuniversalsocketoutletNo3013A,3-pinswitchedsocketoutletwithneonindicatorNo3020A,DP,ACswitchNo65.1.4ElectricalAppliancesworktoincludefixingofappliances6insextractfanNo8CeilingfanNo125.1.5SubmainDistributionBoardsSMDB-PS(1)Set1SMDB-PS(2)Set15.1.6SubDistributionBoards63A,TPN+E,18waySet263A,TPN+E,18waySet25.1.7MotorControlCentres(MCC)forpumpsSet25.1.8PowerCablesIncludingsupplyofglands&lugs-NBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite5cx16mm2,CU,XLPE/PVC,flexibleML2504cx70mm2,CU,XLPE/SWA/PVC,ML2504cx95mm2,CU,XLPE/SWA/PVC,ML505.1.9Earthingwiresworktoincludefixing&(16) MEDICALFACULTIESCOMPLEXBILLSOFQUANTITIESAMARCONSULTBUILDINGNAME:MASTERPLANBILLSOFQUANTITIESFORELECTRICALWORKSATORIESCOLLEGEterminationofearthwirestoallmetalenclosures,cablearmourcompleteasrequiredwithallnecessaryaccessoriesNB:-Statedwirelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1c×35mm2PVCinsulated(Y/G)cu.conductorML2501c×50mm2PVCinsulated(Y/G)cu.conductorML505.2Lightingpolespoints-foroutdoorlighting,worktoincludeerectionofpolesonconcreteblockfoundation,layingofcableinsuitablysizedundergroundpvcpipes,cabletermination,earthingconnection,completewithallnecessaryaccessoriesasrequired:-5.2.12metershighroundgalvanisedsteelpole50mmdia.fittedwith200×200×10mmbaseplatewithanchorboltssuitableforfixingonaconcretefoundationblock.Thepoleshallbefittedwithaccessdoorforwireterminal&mcb.No1485.2.2Singlearm,6metershigh,octagonaltaperedgalvanisedsteelpole,3.0mmthickness,armlength750mmfittedwith400×400×10mmbaseplatewithanchorboltssuitableforfixingonaconcretefoundationblock.Thepoleshallbefittedwithaccessdoorforwireterminal&mcb.No54Dittoasabovebutdoublearm,.No115.2.3FlexibleCablesIncludingsupplyofglands&lugs-NBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite3cx6mm2,CU,XLPE/PVCML5003cx4mm2,CU,XLPE/PVCML5005.2.4LightingFixturesworktoinclude,fixingoffixturesandwireterminationcompletewithallnecessaryaccessories:1x26Wenergysavinglamp,300mmdia.clearunbreakableglassbollardballIP54,mountedon2metershighpoles.No1481x250W,sodiumvapourlantern,IP54,mountedon6metershighpoles.No655.2.5SubDistributionBoards63A,TPN+E,12waySet4(16) MEDICALFACULTIESCOMPLEXBILLSOFQUANTITIESAMARCONSULTBUILDINGNAME:MASTERPLANBILLSOFQUANTITIESFORELECTRICALWORKSATORIESCOLLEGE5.2.6ElectricalDevicesworktoincludefixingofdevices,10A,PhotocellNo232A,TP,500V,enclosedcontactorNo2TOTALCARRIEDTOSUMMARY6EMERGENCYPOWERSUPPLYSYSTEM6.1FACULTYOFDENTISTRY(DS)EMERGENCYSTANDBYSYSTEM6.1.1StandbyDieselGensets-700KVArated,1500rpm,415/240V,50Hzdiesel,water-cooledengine,soundproofgeneratingset.Worktoincludeconstructionofconcretefoundation&steelcage,placingofgenset,terminationofcables&wires,installationofearthing,supply&erectionofbulkfueltank&pipingandanyotherworksasrequiredSet16.1.2Automatictransferswitch1250A,600v,4-poleACBsSet16.1.3PowerCablesIncludingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite.1cx500mm2,XLPE/AWA/PVC,powercableforconnectionfromGeneratortoATS.ML2006.1.4EarthingCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx500mm2,CU,PVC/PVCML30TOTALCARRIEDTOSUMMARY6.2LIBRARY,MOSQUE,SPINEENTRANCE(LMS)EMERGENCYSTANDBYSYSTEM-6.2.1StandbyDieselGensets-380KVArated,1500rpm,415/240V,50Hzdiesel,water-cooledengine,soundproofgeneratingset.Worktoincludeconstructionofconcretefoundation&steelcage,placingofgenset,terminationofcables&wires,installationofearthing,supply&erectionofbulkfueltank&pipingandanyotherworksasrequiredSet1(16) MEDICALFACULTIESCOMPLEXBILLSOFQUANTITIESAMARCONSULTBUILDINGNAME:MASTERPLANBILLSOFQUANTITIESFORELECTRICALWORKSATORIESCOLLEGE6.2.2Automatictransferswitch600A,600v,4-poleContactorsSet16.2.3PowerCablesIncludingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite.4cx185mm2,XLPE/SWA/PVC,powercableforconnectionfromGeneratortoATS.ML606.2.4EarthingCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite4cx185mm2,CU,PVC/PVCML30TOTALCARRIEDTOSUMMARY6.3FACULTYOFMEDICALLABORARTORIES(ML)EMERGENCYSTANDBYSYSTEM-6.3.1StandbyDieselGensets-700KVArated,1500rpm,415/240V,50Hzdiesel,water-cooledengine,soundproofgeneratingset.Worktoincludeconstructionofconcretefoundation&steelcage,placingofgenset,terminationofcables&wires,installationofearthing,supply&erectionofbulkfueltank&pipingandanyotherworksasrequiredSet16.3.2Automatictransferswitch1250A,600v,4-poleACBsSet16.3.3PowerCablesIncludingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite.1x500mm2,XLPE/AWA/PVC,powercableforconnectionfromGeneratortoATS.ML2006.3.4EarthingCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx500mm2,CU,PVC/PVCML30TOTALCARRIEDTOSUMMARY(16) MEDICALFACULTIESCOMPLEXBILLSOFQUANTITIESAMARCONSULTBUILDINGNAME:MASTERPLANBILLSOFQUANTITIESFORELECTRICALWORKSATORIESCOLLEGE6.4FACULTYOFDIAGONTICCENTRE(DN)EMERGENCYSTANDBYSYSTEM6.4.1StandbyDieselGensets-worktoincludeconstructionofconcretefoundation&steelcage,placingofgenset,terminationofcables&wires,installationofearthing,supply&erectionofbulkfueltank&pipingandanyotherworksasrequired700KVArated,1500rpm,15/240V,50Hzdiesel,water-cooledengine,soundproofgeneratingset.Set1250KVArated,1500rpm.,415/240V,50Hzdiesel,water-cooledengine,soundproofgeneratingset.Set1Automatictransferswitch1250A,600v,4-poleACBsSet1Automatictransferswitch400A,600v,4-poleContactorsSet16.4.2PowerCablesIncludingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite.1cx500mm2,XLPE/AWA/PVC,powercableforconnectionfromGeneratortoATS.ML2004cx120mm2,XLPE/SWA/PVC,powercableforconnectionfromGeneratortoATS.ML2006.4.3EarthingCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx500mm2,CU,PVC/PVCML301cx120mm2,CU,PVC/PVCML30TOTALCARRIEDTOSUMMARY6.5FACULTYOFPHARMACOLOGY(PH)EMERGENCYSTANDBYSYSTEM–PH6.5.1StandbyDieselGensets-700KVArated,1500rpm,415/240V,50Hzdiesel,water-cooledengine,soundproofgeneratingset.Worktoincludeconstructionofconcretefoundation&steelcage,placingofgenset,terminationofcables&wires,installationofearthing,supply&erectionSet1(16) MEDICALFACULTIESCOMPLEXBILLSOFQUANTITIESAMARCONSULTBUILDINGNAME:MASTERPLANBILLSOFQUANTITIESFORELECTRICALWORKSATORIESCOLLEGEofbulkfueltank&pipingandanyotherworksasrequired6.5.2Automatictransferswitch1250A,600v,4-poleACBsSet16.5.3PowerCablesIncludingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite.1x500mm2,XLPE/AWA/PVC,powercableforconnectionfromGeneratortoATS.ML2006.5.4EarthingCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx500mm2,CU,PVC/PVCML30TOTALCARRIEDTOSUMMARY6.6FACULTYOFRADIOLOGY(RD)EMERGENCYSTANDBYSYSTEM6.6.1StandbyDieselGensets-700KVArated,1500rpm,415/240V,50Hzdiesel,water-cooledengine,soundproofgeneratingset.Worktoincludeconstructionofconcretefoundation&steelcage,placingofgenset,terminationofcables&wires,installationofearthing,supply&erectionofbulkfueltank&pipingandanyotherworksasrequiredSet16.6.2Automatictransferswitch1250A,600v,4-poleACBsSet16.6.3PowerCablesIncludingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite.1x500mm2,XLPE/AWA/PVC,powercableforconnectionfromGeneratortoATS.ML2006.6.4EarthingCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite1cx500mm2,CU,PVC/PVCML30TOTALCARRIEDTOSUMMARY(16) MEDICALFACULTIESCOMPLEXBILLSOFQUANTITIESAMARCONSULTBUILDINGNAME:MASTERPLANBILLSOFQUANTITIESFORELECTRICALWORKSATORIESCOLLEGE6.7CAFETERIA(CF)EMERGENCYSTANDBYSYSTEM6.7.1StandbyDieselGensets-200KVArated,1500rpm,415/240V,50Hzdiesel,water-cooledengine,soundproofgeneratingset.Worktoincludeconstructionofconcretefoundation&steelcage,placingofgenset,terminationofcables&wires,installationofearthing,supply&erectionofbulkfueltank&pipingandanyotherworksasrequiredSet16.7.2Automatictransferswitch250A,600v,4-poleContactorsSet16.7.3PowerCablesIncludingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite.4cx95mm2,XLPE/SWA/PVC,powercableforconnectionfromGeneratortoATS.ML606.7.4EarthingCables.Includingsupplyofglands,lugs,bolts&nuts,completeasrequiredNBStatedcablelengthsareapproximate,deliveryshallbeafterexactmeasurementoflengthonsite4cx50mm2,CU,PVC/PVCML30TOTALCARRIEDTOSUMMARY7NECMAINPOWERSUPPLYWORKSNECMAINPOWERSUPPLYWORKSNECisdesiredtosupply&installthefollowingequipment,materials,11KVswitchgear,KWHmetering,11KVearthing&allaccessoriesforthefollowingequipmentasspecified&shownonthedrawings,alluptothesatisfactionoftheEngineer.TheContractorshallquoteonlyforhisexpensescoveringthesubmittalofapplicationtoNECandincludingliaison&coordinationwithNEC7.1FACULTYOFDENTISTRY(DS)1500KVAtransformer,11/0.4KV,DY11No17.2LIBRARY,MOSQUE&SPINEENTRANCE(LMS)1000KVAtransformer,11/0.4KV,DY11No1(16) MEDICALFACULTIESCOMPLEXBILLSOFQUANTITIESAMARCONSULTBUILDINGNAME:MASTERPLANBILLSOFQUANTITIESFORELECTRICALWORKSATORIESCOLLEGE7.3FACULTYOFMEDICALLABORATORIES(ML)1500KVAtransformer,11/0.4KV,DY11No17.4DIAGNOSTICCENTRE(DN)1500KVAtransformer,11/0.4KV,DY11No17.5FACULTYOFPHARMACOLOGY(PH)1500KVAtransformer,11/0.4KV,DY11No17.6FACULTYOFRADIOLOGY(RD)1500KVAtransformer,11/0.4KV,DY11No17.7CAFTERIA(CF)&FUTURECONFERENCEHALL(CF)1500KVAtransformer,11/0.4KV,DY11No1TOTALCARRIEDTOSUMMARY(16) MEDICALFACULTIESCOMPLEXBILLSOFQUANTITIESAMARCONSULTBUILDINGNAME:MASTERPLANBILLSOFQUANTITIESFORELECTRICALWORKSATORIESCOLLEGESUMMARYITEMNO.DESCRIPTIONUNITQTYRATEAMOUNT(SD)1MAINPOWERDISTRIBUTIONSYSTEM2CABLETRENCHESWORKS3MAINPOWERDISTRIBUTIONSYSTEMFROMPOWERHOUSE(1)4MAINPOWERDISTRIBUTIONSYSTEMFROMPOWERHOUSE(2)5OUTDOORLIGHTINGSYSTEMWORKS6EMERGENCYPOWERSUPPLYSYSTEM7NECMAINPOWERSUPPLYWORKSTOTALCARRIEDTOGRANDSUMMARY(16)'