• 1.87 MB
  • 67页

西安某地中央空调毕业设计说明书

  • 67页
  • 当前文档由用户上传发布,收益归属用户
  1. 1、本文档共5页,可阅读全部内容。
  2. 2、本文档内容版权归属内容提供方,所产生的收益全部归内容提供方所有。如果您对本文有版权争议,可选择认领,认领后既往收益都归您。
  3. 3、本文档由用户上传,本站不保证质量和数量令人满意,可能有诸多瑕疵,付费之前,请仔细先通过免费阅读内容等途径辨别内容交易风险。如存在严重挂羊头卖狗肉之情形,可联系本站下载客服投诉处理。
  4. 文档侵权举报电话:19940600175。
'华北水利水电学院摘要本设计结合西安地区的自然条件和建筑物结构的实际情况,对该建筑进行冬夏两用中央空调系统设计。设计中首先进行冷负荷计算,然后确定空调系统形式,进行平面布置,水力计算后选择水管和风管。制冷、制热站设计,首先进行冷、热源选择,技术比较后确定所用机组设备方案。对站房进行平面布置,选择附属设备,作系统原理图。防排烟系统设计,根据建筑物实际,严格按照防火防排烟规范,确定防烟排烟系统形式,进行平面和系统设计。关键词:冷热负荷水力计算冷热源隔声与防震加压送风67 华北水利水电学院AbstractThisdesigncombinesthenaturalconditionofXi"an"sregionandtheactualcircumstanceofthebuildingstructures,toshouldconstructtocarryonthewintersummertwousethecentralairconditionsystemdesign.Designwincarryonthecoldhotburdencalculationfirst,thenmakesuretheairconditionsystemform,carryonflatsurface"sarrange,thewaterpowercalculationchoosesthepipelinemoderatebreezestubebehind.Makecold,makethehotstationdesign,carryonthecoldandhotsourcechoicefirst,aftertechniquecomparecertainequipmentsprojectofmachineuse.Carryonflatsurface"sarrangetothestation,choosethesubsidiaryequipments,makethesystemprinciplediagram.Defendtolineupthesmokesystemdesign,accordingtothebuildingactual,defendtolineupthesmokenormaccordingtothefirepreventionstrictly,makesuretodefendthesmokerowsmokesystemform,carryontheflatsurfaceandsystemdesigns.Keywords:Coldhotburden,waterpowerthecalculation,thecoldandhotsource,separatethevoiceandquakeproofs,airpressure67 华北水利水电学院前言中国的建筑行业正处于飞速发展的阶段,人们对生活环境的要求也越来越高,而生活环境最主要的就是居住环境,这种需求带动了中国的空调制冷业的发展,特别是在“非典”之后,人们对室内空气品质(IAQ)有了更深刻的认识,室内空气的好坏直接影响到人们的健康,原来使用的空调技术已经不能满足人们的要求,对环境的需求意识已经不是简单的冷热意识,而是趋向于健康化、卫生化的需求。因此采用更先进的空气调节方法提高空气品质满足人们的要求成了当前制冷行业发展的热点和重点之一。另外一方面,从2001年至今,电力紧缺的问题一直困扰着我们,电厂的发展又不能盲目的增加发电量,或者增建新的电厂,必须依靠宏观的发展才能不至于发生电力过剩的尴尬局面,而且电厂发电对环境的污染也会随着电厂的增加而增加,在这种情况下,空调作为用电大户,充分利用现有的自然能,如太阳能、地热能、生活垃圾等可利用的能量资源既减轻了当前电力的负担,又增加了空调的环保能力,因此,利用自然资源,保护环境也成了当前各国空调制冷行业的研究方向。还有一个问题也是我们比较关心的问题,那就是“可持续发展”的观点,根据1987年9月16日在加拿大的蒙特利尔会议上通过的联合国环境规划署组织制定的《关于消耗臭氧层物质的蒙特利尔议定书》,对CFC及哈龙两类中8种破坏臭氧层的物质进行限控,规定发达国家2000年完全停止使用这些物质,发展中国家2010年完全停止使用这些物质。我国已经确定了2010年全面淘汰的方案和行动计划,并且开展了替代品及替代技术的研究与开发。当前空调行业的已经在这些方面有了一定的进步,许多节能性空调如变频空调正越多的得到使用,而在中央空调方面,溴化锂双吸收式制冷等保护环境的制冷剂设备也发展的越来越快。热泵技术的使用既有效利用了自然能源,节省了能量,同时又保护了环境。本文,我们采用了风冷热泵、板式换热器、风机盘管系统对建筑环境进行调节。首先使用地源热泵充分利用了地热资源,节约能源;其次也从根本上消除了由于使用空调而产生的室内环境循环被污染的现象。地源热泵技术在国内尚处于发展阶段,设计不足之处在所难免,还望各位批评指正。67 华北水利水电学院目录摘要1Abstract2前言31、工程概况与设计范围61.1工程概况61.2设计气象参数61.2.1室外气象参数61.3、设计范围62.负荷计算62.1冷热负荷的计算62.1.1围护结构冷负荷的计算方法62.1.2日射得热引起的冷负荷82.1.3设备散热形成的冷负荷82.1.4照明散热形成的冷负荷92.1.5人体散热形成的冷负荷102.2新风负荷162.3湿负荷183.空调系统的论证213.1方案比较213.2方案的确定243.3风机盘管机组的结构和工作原理244.空调水系统设计254.1水系统的比较、选择254.2空调水系统的布置264.3风机盘管水系统水力计算274.3.1基本公式275.新风系统设计295.1新风进口位置:295.2新风口其他要求:295.3风道的布置和制作要求295.4百叶送风口的选择步骤295.5风口的选择295.5.1气流组织设计计算29新风系统水利计算326通风防排烟设计4967 华北水利水电学院6.1设计说明496.1.1需要进行防烟设计的建筑及部位《高层建筑防排烟设计规范》:497风冷热泵、板式换热器的布置507.1机组选型507.1.2分水器和集水器的构造和用途517.2循环水泵的选型和计算527.2.1水泵的选型和计算527.3循环水泵配管布置53致谢54外文翻译55参考文献6767 华北水利水电学院1、工程概况与设计范围1.1工程概况该建筑物是西安某星级酒店。该建筑的基本情况:(1):各层主要内容:一层为男女更衣室,男女卫生间,办公室电脑监控室,咖啡厅和大堂,二层为男女卫生间,衣帽间,更衣室,准备间,大茶厅等,三层全部为包厢,四层为包厢和会议室,五至八层全部为客房,九层为客房和会客厅,详见建筑施工图。(2):建筑物高度为:34.2米1.2设计气象参数1.2.1室外气象参数1.西安位置:北纬34°18′东经108°56′ 海拔396.9m2.室外计算干球温度:夏季空调为35.2℃冬季空调为-8℃3.夏季空调室外计算湿球温度为26.0℃4.室外风速:夏季:V=2.7m/s;冬季:V=2.5m/s1.2.2室内计算参数:夏季: T夏=26℃冬季: T冬=18℃   新风量标准:30m3/人.h1.3、设计范围西安某星级酒店中央空调设计:九层中央空调设计,楼梯间的防排烟。一至九层空调送风和空调供回水的平面图和系统图的设计。该建筑大空间采用风机盘管加新风系统设计,小空间采用全空气系统设计。楼梯间的加压送风设计;冷热机房的设计,卫生间的排风设计。2.负荷计算2.1冷热负荷的计算2.1.1围护结构冷负荷的计算方法2.1.1.1外墙和屋面瞬变传热引起的冷负荷67 华北水利水电学院在日射和室外气温综合作用下,外墙和屋面瞬变传热引起的逐时冷负荷可按下式计算:Qc=A.K(tc-tr)(2.1)式中:Qc——外墙和屋面瞬变传热引起的逐时冷负荷,W;A——外墙和屋面的面积,㎡;K——外墙和屋面的传热系数,W/(㎡·℃),可根据外墙和屋面的不同构造,表一中查取;Tc——室内计算温度,℃;Tr——外墙和屋面冷负荷计算温度的逐时值,℃,根据外墙和屋面的不同类型分别在《暖通空调》课本中查取必须指出:(2.1)式中的各围护结构的冷负荷温度值都是以西安地区气象参数为依据计算出来的,因此对不同地区和不同情况应按下式进行修正:t"ln=(tln+td)·ka·kp℃(2.2)式中:td——地区修正系数,℃;ka——不同外表面换热系数修正系数;kp——不同外表面的颜色系数修正系数];2.1.1.2内墙,楼板等室内传热围护结构形成的瞬时冷负荷当空调房间的温度与相邻非空调房间的温度大于5℃时,要考虑由内围护结构的温差传热对空调房间形成的瞬时冷负荷,可按如下传热公式计算:Q2=A.K(t1-t1o)W(2.3)式中:A——内围护结构的传热面积,m²;K——内围护结构的传热系数,W/(m²·k);T1——夏季空调房间室内设计温度,℃;T1O——相邻非空调房间的平均计算温度,℃。t"ls按下式计算t"ls=t+tls℃(2.4)式中:t——夏季空调房间室外计算日平均温度,℃;tls——67 华北水利水电学院相邻非空调房间的平均计算温度与夏季空调房间室外计算日平均温度差值,当相邻散热量很少(如走廊)时,tls取3℃,;当相邻散热量在23~116W/m2时,tls取5℃。2.1.1.3外玻璃窗瞬变传热引起的冷负荷在室内外温差的作用下,玻璃窗瞬变热形成的冷负荷可按下式计算:Q3=AK(t1-ta)(2.5)式中:A——外玻璃窗面积,m²;K——玻璃的传热系数,W/(m²·k);本设计双层钢窗K=2.68W/(m²·k);tl——玻璃窗的冷负荷温度逐时值,℃;tn——室内设计温度,℃。不同地点按下式进行修正t1’=t1+td(2.6)td——地区修正系数,℃]。2.1.2日射得热引起的冷负荷透过玻璃窗进入室内的日射得热形成的逐时冷负荷按下式计算:Qc=Cs.Aw.Cz.Djmax(2.7)式中:A——玻璃窗的净面积,是窗口面积乘以有效面积系数Ca,本设计双层钢窗Ca=0.85;CZ——玻璃窗的综合遮挡系数CZ=Cs·Cn;其中,Cs——玻璃窗的遮挡系数,6mm厚吸热玻璃Cs=0.89;Cn——窗内遮阳设施的遮阳系数,中间色活动百叶帘Cn=0.6;Dj.max——日射得热因数的最大值,W/m²;CLQ——冷负荷系数。2.1.3设备散热形成的冷负荷设备和用具显热形成的冷负荷按下式计算:Q7=Qs.CLQ(2.8)式中:Q7——设备和用具实际的显热形成的冷负荷,W;67 华北水利水电学院Qq——设备和用具的实际显热散热量,W;CLQ——设备和用具显热散热冷负荷系数;如果空调系统不连续运行,则CLQ=1.0。2.1.3.1电动设备当工艺设备及其电动机都放在室内时:Q=1000·n1·n2·n3·N/η(2.9)当只有工艺设备在室内,而电动机不在室内时:Q=1000·n1·n2·n3·N(2.10)当工艺设备不在室内,而只有电动机放在室内时:Q=1000·n1·n2·n3·N(2.11)式中:N——电动设备的安装功率,kW;η——电动机效率,可由产品样本查得;n1——利用系数,是电动机最大实效功率与安装功率之比,一般可取0.7~0.9可用以反映安装功率的利用程度;n2——电动机负荷系数,定义为电动机每小时平均实耗功率与机器设计时最大实耗功率之比;n3——同时使用系数,定义为室内电动机同时使用的安装功率与总安装功率之比,一般取0.5~0.8。2.1.3.2电热设备散热量对于无保温密闭罩的电热设备,按下式计算:Q=1000·n1·n2·n3·n4·N(2.12)式中:n4——考虑排风带走热量的系数,一般取0.5;其中其他符号意义同前。2.1.4照明散热形成的冷负荷根据照明灯具的类型和安装方式的不同,其冷负荷计算式分别为:白炽灯:Q5=1000·N·CLQW(2.13)荧光灯:Q5=1000·n1·n2·N·CLQW(2.14)式中:Q5——灯具散热形成的冷负荷,W;67 华北水利水电学院N——照明灯具所需功率,KW;n1——镇流器消耗功率系数,当明装荧光灯的镇流器装在空调房间内时,取n1=1.2;当暗装荧光灯镇流器装设在顶棚内时,可取n1=1.0;本设计取n1=1.0;n2——灯罩隔热系数,当荧光灯上部穿有小孔(下部为玻璃板),可利用自然通风散热与顶棚内时,取n2=0.5~0.8;而荧光灯罩无通风孔时,取n2=0.6~0.8;本设计取n2=0.6;CLQ——照明散热冷负荷系数。本设计照明设备为暗装荧光灯,镇流器设置在顶棚内,荧光灯罩无通风孔,功率为30w/m²。设备负荷为40w/m²。2.1.5人体散热形成的冷负荷人体散热引起的冷负荷计算式为:Qc=qs.n.n’Clq(2.15)式中:LQ6——人体散热形成的冷负荷,W;qs——不同室温和劳动性质成年男子显热散热量;n——室内全部人数;n’——群集系数,酒店群集系数为0.89;CLQ——人体显然散热冷负荷系数,人体显然散热冷负荷系数。冷负荷计算书:(以一楼咖啡厅111房间为例)111(241.2㎡)北外墙冷负荷时间11:0012:0013:0014:0015:0016:0017:0018:0019:0020:0021:0022:0023:000:00tc(τ)32.432.232.13231.931.831.831.831.831.831.93232.132.2Kα1Kρ0.94tc"(τ)32.1531.9631.931.831.6831.631.631.631.631.5831.6831.831.932tR26K1A40.08Qc246.4238.9235231227.6224224224224223.8227.623123523967 华北水利水电学院北外窗冷负荷时间11:0012:0013:0014:0015:0016:0017:0018:0019:0020:0021:0022:0023:000:00tc(τ)29.930.831.531.932.232.23231.630.829.929.128.427.827.2△td231.932.833.533.934.234.23433.632.831.931.130.429.829.2tR26△t5.96.87.57.98.28.287.66.85.95.14.43.83.2Kw3.612Aw13.92Qc296.6341.9377397412.3412402382342296.6256.4221191161东外墙冷负荷时间11:0012:0013:0014:0015:0016:0017:0018:0019:0020:0021:0022:0023:000:00tc(τ)36.636.936.236.136.136.236.336.436.636.83737.237.337.5△td0.9Kα1Kρ0.94tc"(τ)35.2535.5334.934.834.7834.93535.135.335.4435.6335.835.936.1tR26K1A16.2Qc149.9154.4144142142.2144145147150152.9155.9159161164北外窗透入日射引起的冷负荷时间11:0012:0013:0014:0015:0016:0017:0018:0019:0020:0021:0022:0023:000:00Clq0.610.640.660.660.630.590.640.640.380.350.320.30.280.26Dj144Ccs0.86*0.5=0.43Aw10.44Qc394.3413.7427427407.3381414414246226.3206.9194181168东外窗冷负荷时间11:0012:0013:0014:0015:0016:0017:0018:0019:0020:0021:0022:0023:000:00tc(τ)29.930.831.531.932.232.23231.630.829.929.128.427.827.2△td231.932.833.533.934.234.23433.632.831.931.130.429.829.2tR26△t5.96.87.57.98.28.287.66.85.95.14.43.83.2Kw3.61267 华北水利水电学院Aw59.0625Qc12591451160016851749174917071621145112591088939811683东外窗透入日射引起的冷负荷时间11:0012:0013:0014:0015:0016:0017:0018:0019:0020:0021:0022:0023:000:00Clq0.280.290.290.280.260.240.220.190.170.160.150.140.130.12Dj599Ccs0.86*0.5=0.43Aw17.5*4.5*0.75=59.0625Qc42604412441242603955365133472890258624342282213019781826照明散热引起的冷负荷时间11:0012:0013:0014:0015:0016:0017:0018:0019:0020:0021:0022:0023:000:00Clq0.740.760.790.810.830.840.860.870.890.90.920.290.260.23n11.2n21N1200(按5w/㎡计算)Qc10661094113811661195121012381253128212961325418374331人员散热引起的冷负荷时间11:0012:0013:0014:0015:0016:0017:0018:0019:0020:0021:0022:0023:000:00Clq0.530.620.690.740.770.80.830.850.870.890.420.340.280.23qs60.5n24(按0.1人㎡算)φ0.89Qc1684.9801.2892956995.110341073109811241150542.8439362297ql73.3Qc24442560265127152754279328322858288329092302219921212056各项逐时负荷汇总表时间11:0012:0013:0014:0015:0016:0017:0018:0019:0020:0021:0022:0023:000:00北外墙246.4238.9235231227.6224224224224223.8227.6231235239北外窗296.6341.9377397412.3412402382342296.6256.4221191161北窗日射394.3413.7427427407.3381414414246226.3206.9194181168东外墙149.9154.4144142142.2144145147150152.9155.9159161164东外窗125914511600168517491749170716211451125910889398116834260441244124260395536513347289025862434228221301978182667 华北水利水电学院东窗日射照明10661094113811661195121012381253128212961325418374331人员散热24442560265127152754279328322858288329092302219921212056总计101151066610982110241084310564103089789916387987843649060515627此房间最大冷负荷出现在14时,其值是11024.22冷负荷汇总表:房间最大冷负荷(w)Kw房间最大冷负荷(w)Kw106547.26620.5472662107687.26620.6872662501833.57510.833575108687.26620.6872662502833.57510.833575109643.11030.6431103503833.57510.8335751101346.7021.346702504833.57510.83357511111024.2211.02422505833.57510.833575大堂13358.6213.35862506833.57510.833575一楼总负荷28294.450928.2944509507833.57510.8335755081090.4931.0904932031203.9161.2039165091437.8991.437899204859.03120.85903125101317.2941.3172942052741.1632.7411635111317.2941.317294207479.64410.47964415121317.2941.317294208479.64410.47964415131317.2941.317294209859.03120.85903125141463.9841.463984大厅18013.2618.013265151463.9841.463984二楼总负荷31157.862231.15786225161317.2941.3172945171317.2941.317294301864.61770.86461775181317.2941.317294302833.57510.83357515191317.2941.317294303833.57510.83357515201415.0571.415057304933.56210.9335621五楼总负荷40783.8240.783823051437.8991.4378993061317.2941.3172949011098.7741.0987743071317.2941.3172949021098.7741.0987743081317.2941.3172949031098.7741.0987743091317.2941.3172949041098.7741.09877467 华北水利水电学院3101105.3581.1053589051098.7741.098774311833.57510.83357519061098.7741.0987743122022.7562.0227569071098.7741.0987743131463.9841.4639849081355.9681.3559683141317.2941.3172949091580.6061.5806063151317.2941.3172949101463.0921.4630923161317.2941.3172949111463.0921.4630923171317.2941.3172949121463.0921.4630923181415.0571.4150579131463.0921.463092三楼总负荷28396.4266628.39642679141648.0931.6480939151648.0931.648093401864.61770.86461779161463.0921.463092402833.57510.83357519171463.0921.463092403833.57510.83357519181463.0921.463092404955.26230.95526239191463.0921.4630924051105.3581.1053589201560.3021.560302406833.57510.8335751九楼总负荷40783.8240.783824072022.7562.0227564087599.3167.599316建筑总冷负荷321.42814091463.9841.4639844101463.9841.4639844111317.2941.3172944121317.2941.3172944131317.2941.3172944141317.2941.3172944151415.0571.415057四楼总负荷29660.236329.6602363热负荷计算书房间面积m2热负荷w房间热负荷w10630210010730210050134238010830210050234238010930210050334238011030210050434238011125217640505342380大堂380266005063423805474050734238067 华北水利水电学院一楼总负荷508342380203342380509342380204342380510342380205684760511342380207181260512382660208181260513422940209181260514453150大厅57640320515453150二楼总负荷53620516422940517382660301342380518342380302342380519342380303342380520342380304342380五楼总负荷50820305342380306342380901342380307342380902342380308382660903342380309422940904342380310342380905342380311342380906342380312684760907342380313453150908342380314382660909342380315382660910342380316342380911342380317342380912382660318342380913422940三楼总负荷47390914453150915453150401342380916422940402342380917382660403342380918342380404342380919342380405342380920342380406342380九楼总负荷508204076847604081501050067 华北水利水电学院409453150410453150411422940412382660413342380414342380415342380四楼总负荷48580总热负荷458430458.43kw2.2新风负荷目前,我国空调设计中对新风量的确定原则,仍采用现行规范、设计手册中规定或推荐的原则,酒店的新风量取30m³/h.p。夏季,空调新风冷负荷按下式计算:Qc=1.2·LW·(hW-hN)W(2.16)式中:Qc——夏季新风冷负荷,KW;LW——新风量,kg/s;hW——室外空气的焓值,kj/kg;hN——室内空气的焓值,kj/kg。新风负荷计算书:房间nh0hRQ(w)房间新风量(kg/h)新风量(m3/h)106380.763.43518.1106108129.6107380.763.43518.1107108129.6108380.763.43518.1108108129.6109380.763.43518.1109108129.6110380.763.43518.1110108129.6106-1102590.5106-1106481112480.763.434144.81118641036.8大堂4580.763.439771.5大堂16201944一层合计24560.8203380.763.43518.1203108129.6204380.763.43518.1204108129.6205780.763.431208.9205252302.4207280.763.43345.42077286.4208280.763.43345.42087286.467 华北水利水电学院209280.763.43345.42097286.43281.3203-209820.8大厅4680.763.437944.2大厅16561987.2二层合计21506.8301380.763.43518.1301108129.6302380.763.43518.1302108129.6303380.763.43518.1303108129.6304380.763.43518.1304108129.6305380.763.43518.1305108129.6306380.763.43518.1306108129.6307380.763.43518.1307108129.6308380.763.43518.1308108129.6309480.763.43690.8309144172.8310380.763.43518.1310108129.6311380.763.43518.1311108129.6312780.763.431208.9312252302.4313480.763.43690.8313144172.8314380.763.43518.1314108129.6315380.763.43518.1315108129.6316380.763.43518.1316108129.6317380.763.43518.1317108129.6318380.763.43518.1318108129.6三层合计18309.221602592401380.763.43518.1401108129.6402380.763.43518.1402108129.6403380.763.43518.1403108129.6404380.763.43518.1404108129.6405380.763.43518.1405108129.6406380.763.43518.1406108129.6407780.763.431208.9407252302.44081580.763.432590.5408540648409480.763.43690.8409144172.8410480.763.43690.8410144172.8411380.763.43518.1411108129.6412380.763.43518.1412108129.6413380.763.43518.1413108129.6414380.763.43518.1414108129.6415380.763.43518.1415108129.6四层合计20880.122682721.6501380.763.43518.1501108129.6502380.763.43518.1502108129.667 华北水利水电学院503380.763.43518.1503108129.6504380.763.43518.1504108129.6505380.763.43518.1505108129.6506380.763.43518.1506108129.6507380.763.43518.1507108129.6508380.763.43518.1508108129.6509380.763.43518.1509108129.6510380.763.43518.1510108129.6511380.763.43518.1511108129.6512380.763.43518.1512108129.6513380.763.43518.1513108129.6514480.763.43690.8514144172.8515480.763.43690.8515144172.8516380.763.43518.1516108129.6517380.763.43518.1517108129.6518380.763.43518.1518108129.6519380.763.43518.1519108129.6520380.763.43518.1520108129.6五层合计20707.422322678.4901380.763.43518.1901108129.6902380.763.43518.1902108129.6903380.763.43518.1903108129.6904380.763.43518.1904108129.6905380.763.43518.1905108129.6906380.763.43518.1906108129.6907380.763.43518.1907108129.6908380.763.43518.1908108129.6909380.763.43518.1909108129.6910380.763.43518.1910108129.6911380.763.43518.1911108129.6912380.763.43518.1912108129.6913380.763.43518.1913108129.6914480.763.43690.8914144172.8915480.763.43690.8915144172.8916380.763.43518.1916108129.6917380.763.43518.1917108129.6918380.763.43518.1918108129.6919380.763.43518.1919108129.6920380.763.43518.1920108129.6九层合计20707.422322678.4新风负荷合计209501.3209.501KW67 华北水利水电学院2.3湿负荷人体散湿量可按下式计算:Mw=0.278.n.n’w(2.17)式中:mw——人体散湿量,kg/h;n’——群集系数,酒店群集系数为0.93;w——成年男子的小时散热量,kg/(h·p);26℃时,极轻劳动成年男子的小时散热量为0.109kg/(h·p)。湿负荷计算书:房间nψgMw(kg/s)Mw(kg/h)10630.931840.0001427140.51377110730.931840.0001427140.51377110830.931840.0001427140.51377110930.931840.0001427140.51377111030.931840.0001427140.513771111240.931840.0011417134.110166大堂450.931840.0021407117.70656一楼合计0.00399599414.3855820330.931840.0001427140.51377120430.931840.0001427140.51377120570.931840.0003331.19879820720.931849.51427E-050.34251420820.931849.51427E-050.34251420920.931849.51427E-050.342514大厅460.931840.0021882837.877817二楼合计0.00309213811.131730130.931840.0001427140.51377130230.931840.0001427140.51377130330.931840.0001427140.51377130430.931840.0001427140.51377130530.931840.0001427140.51377130630.931840.0001427140.51377130730.931840.0001427140.51377130830.931840.0001427140.51377130940.931840.0001902850.68502867 华北水利水电学院31030.931840.0001427140.51377131130.931840.0001427140.51377131270.931840.0003331.19879831340.931840.0001902850.68502831430.931840.0001427140.51377131530.931840.0001427140.51377131630.931840.0001427140.51377131730.931840.0001427140.51377131830.931840.0001427140.513771三楼合计0.00285428210.2754140130.931840.0001427140.51377140230.931840.0001427140.51377140330.931840.0001427140.51377140430.931840.0001427140.51377140530.931840.0001427140.51377140630.931840.0001427140.51377140770.931840.0003331.198798408150.931840.000713572.56885340940.931840.0001902850.68502841040.931840.0001902850.68502841130.931840.0001427140.51377141230.931840.0001427140.51377141330.931840.0001427140.51377141430.931840.0001427140.51377141530.931840.0001427140.513771四楼合计0.00299699610.7891850130.931840.0001427140.51377150230.931840.0001427140.51377150330.931840.0001427140.51377150430.931840.0001427140.51377150530.931840.0001427140.51377150630.931840.0001427140.51377150730.931840.0001427140.51377150830.931840.0001427140.51377150930.931840.0001427140.51377151030.931840.0001427140.51377151130.931840.0001427140.51377151230.931840.0001427140.51377151330.931840.0001427140.51377151440.931840.0001902850.68502851540.931840.0001902850.68502867 华北水利水电学院51630.931840.0001427140.51377151730.931840.0001427140.51377151830.931840.0001427140.51377151930.931840.0001427140.51377152030.931840.0001427140.513771五楼合计0.00294942410.6179390130.931840.0001427140.51377190230.931840.0001427140.51377190330.931840.0001427140.51377190430.931840.0001427140.51377190530.931840.0001427140.51377190630.931840.0001427140.51377190730.931840.0001427140.51377190830.931840.0001427140.51377190930.931840.0001427140.51377191030.931840.0001427140.51377191130.931840.0001427140.51377191230.931840.0001427140.51377191330.931840.0001427140.51377191440.931840.0001902850.68502891540.931840.0001902850.68502891630.931840.0001427140.51377191730.931840.0001427140.51377191830.931840.0001427140.51377191930.931840.0001427140.51377192030.931840.0001427140.513771九楼合计0.00294942410.617933.空调系统的论证建筑特点酒店外围护结构多为钢筋混凝土的框架结构,采用自重的重型墙体材料作为外围护结构。使用特点酒店的使用性质与时间全楼基本一致,所以整幢楼可选择用同样的空调系统和设备,管理比较方便。该楼有办公室、会议室、大厅和客房等,根据具体情况对建筑进行空调系统设计。为满足使用的要求,采用风机盘管加新风系统和全空气系统67 华北水利水电学院进行空气调节。3.1方案比较表3.1全空气系统与空气-水系统方案比较比较项目全空气系统空气-水系统设备布置与机房l空调与制冷设备可以集中布置在机房l机房面积较大层高较高l有时可以布置在屋顶或吊顶安装机组l只需要新风空调机房、机房面积小l风机盘管可以设在空调机房内或单独设置l分散布置、敷设各种管线较麻烦风管系统l空调送回风管系统复杂、布置困难l支风管和风口较多时不易均衡调节风量l放室内时不接送、回风管l为从洁净和健康出发,新风直接送到室内。节能与经济性l可以根据室外气象参数的变化和室内负荷变化实现全年多工况节能运行调节,充分利用室外新风减少与避免冷热抵消,减少冷冻机运行时间l对热湿负荷变化不一致或室内参数不同的多房间不经济l部分房间停止工作不需空调时整个空调系统仍需运行不经济l灵活性大、节能效果好,可根据各室负荷情况自我调节l盘管冬夏兼用,内避容易结垢,降低传热效率l无法实现全年多工况节能运行使用寿命l使用寿命长l使用寿命较长安装l设备与风管的安装工作量大周期长l67 华北水利水电学院安装投产较快,介于集中式空调系统与单元式空调器之间维护运行l空调与制冷设备集中安设在机房便于管理和维护l布置分散维护管理不方便,水系统布置复杂、易漏水温湿度控制l可以严格地控制室内温度和室内相对湿度l对室内温度、湿度、洁净度要求严格时难于满足空气过滤与净化l可以采用中效和高效过滤器,满足室内空气清洁度的不同要求,采用喷水室时水与空气直接接触易受污染,须常换水l过滤性能差,室内清洁度要求较高时难于满足消声与隔振l可以有效地采取消防和隔振措施,采用主风管装消生器l必须采用低噪声风机才能保证室内要求风管互相串通l空调房间之间有风管连通,使各房间互相污染,当发生火灾时会通风管迅速蔓延l各空调房间之间不会污染表3.2风机盘管+新风系统的特点表[2]优点l布置灵活,可以和集中处理的新风系统联合使用,也可以单独使用l各空调房间互不干扰,可以独立地调节室温,并可随时根据需要开停机组,节省运行费用,灵活性大,节能效果好l与集中式空调相比不需回风管道,节约建筑空间l机组部件多为装配式、定型化、规格化程度高,便于用户选择和安装l只需新风空调机房,机房面积小l使用季节长l各房间之间不会互相污染67 华北水利水电学院缺点l对机组制作要求高,则维修工作量很大l机组剩余压头小室内气流分布受限制l分散布置敷设各中管线较麻烦,维修管理不方便l无法实现全年多工况节能运行调节l水系统复杂,易漏水l过滤性能差适用性l适用于旅馆、公寓、医院、办公楼等高层多层的建筑物中,l需要增设空调的小面积多房间建筑室温需要进行个别调节的场合本设计为酒店大楼的中央空调系统设计,系统的选定应注意档次和安全的要求,按负担室内空调负荷所用的介质来分类可选择两种系统——全空气系统和空气—水系统。酒店建筑大空间用全空气系统,对客房、小型会议室等采用空气—水系统,风机盘管的新风供给方式用单设新风系统,独立供给室内。3.2方案的确定该酒店客房等小房间采用风机盘管加新风系统。因为它们的使用功能都适合采用风机盘管加新风系统;每层设有新风机组,可以由同层的新风机组送入室内,和风机盘管一起满足室内的冷热负荷。  风机盘管空调方式,这种方式风管小,可以降低房间层高,但维修工作量大,如果水管漏水或冷水管保温不好而产生凝结水,对线槽内的电线或其它接近楼地面的电器设备是一个威胁,因此要求确保管道安装质量。风机盘管加新风系统占空间少,使用也较灵活,但设计中管道的水利不平衡、空调设备产生的振动和噪音问题需要采取切实措施予以解决。对于该系统所存在的缺点,可在设计当中根据具体的问题予以解决和弥补。该酒店大厅咖啡厅等大空间采用全空气系统。全空气系统有专门的过滤段,有较强的空气除湿能力和空气过滤能力;送风量大,换气充分,空气污染小;在春秋过渡季节可实现全新风运行,节约运行能耗;空调机置于机房内,运转、维修容易,能进行完全的空气过滤;产生震动、噪声传播的问题较少。67 华北水利水电学院3.3风机盘管机组的结构和工作原理风机盘管机组是空调机组的末端机组之一,就是将通风机、换热器及过滤器等组成一体的空气调节设备。机组一般分为立式和卧式两种,可以按室内安装位置选定,同时根据室内装修要求可做成明装或暗装。风机盘管通常与冷水机组(夏)或热水机组(冬)组成一个供冷或供热系统。风机盘管是分散安装在每一个需要空调的房间内(如宾馆的客房、医院的病房、写字楼的各写字间等)。风机盘管机组中风机不断循环所在房间内的空气和新风,使空气通过供冷水或供热水的换热器被冷却或加热,以保持房间内温度。在风机吸风口外设有空气过滤器,用以过滤被吸入空气中的尘埃,一方面改善房间的卫生条件,另一方面也保护了换热器不被尘埃所堵塞。换热器在夏季可以除去房间的湿气,维持房间的一定相对湿度。换热器表面的凝结水滴入接水盘内,然后不断地被排入下水道。由于本系统采用风机盘管+新风系统,有独立的新风系统供给室内新风,即把新风处理到室内参数,不承担房间负荷。这种方案既提高了该系统的调节和运转的灵活性,且进入风机盘管的供水温度可适当提高,水管结露现象可以得到改善。机组由风机、电动机、盘管、空气过滤器、室温调节装置及箱体等组成。4.空调水系统设计4.1水系统的比较、选择空调水系统包括冷冻水系统和冷却水系统两个部分,它们有不同类型可供选择。表4.1空调水系统比较表[1]类型特征优点缺点闭式管路系统不与大气相接触,仅在系统最高点设置膨胀水箱与设备的腐蚀机会少;不需克服静水压力,水泵压力、功率均低。系统简单与蓄热水池连接比较复杂开式管路系统与大气相通与蓄热水池连接比较简单易腐蚀,输送能耗大同程式水量分配,调度方便,67 华北水利水电学院供回水干管中的水流方向相同;经过每一管路的长度相等便于水力平衡需设回程管,管道长度增加,初投资稍高异程式供回水干管中的水流方向相反;经过每一管路的长度不相等不需设回程管,管道长度较短,管路简单,初投资稍低水量分配,调度较难,水力平衡较麻烦两管制供热、供冷合用同一管路系统管路系统简单,初投资省无法同时满足供热、供冷的要求三管制分别设置供冷、供热管路与换热器,但冷热回水的管路共用能同时满足供冷、供热的要求,管路系统较四管制简单有冷热混合损失,投资高于两管制,管路系统布置较简单四管制供冷、供热的供、回水管均分开设置,具有冷、热两套独立的系统能灵活实现同时供冷或供热,没有冷、热混合损失管路系统复杂,初投资高,占用建筑空间较多单式泵冷、热源侧与负荷侧合用一组循环水泵系统简单,初投资省不能调节水泵流量,难以节省输送能耗,不能适应供水分区压降较悬殊的情况复式泵冷、热源侧与负荷侧分别配备循环水泵可以实现水泵变流量,能节省输送能耗,能适应供水分区不同压降,系统总压力低。系统较复杂,初投资较高根据以上各系统的特征及优缺点,结合本酒店情况,本设计空调水系统选择闭式、异程、双管制系统,这样布置的优点是过渡季节只供给新风,不使用风机盘管的时候便于系统的调节,节约能源。67 华北水利水电学院4.2空调水系统的布置本系统设计可以采用双管制供应冷冻水,且具有结构简单,初期投资小等特点。同时考虑到节能与管道内清洁等问题,可以采用闭式系统,不与大气相接触,仅在系统最高点设置膨胀水箱,管路不易产生污垢和腐蚀,不需要克服系统静水压头,水泵耗电较小。由于设计属于多层建筑,而且长度不是很长,因此可以采用异程式水系统,此系统安装方便,节省管材,初投资少,水利平衡也较好。本设计夏季制冷采用风冷热泵机组机组,冬季供热采用板式换热器,。机组布置在楼顶。新风机组和风机盘管系统共用供、回水立管。定压补水系统采用膨胀水箱。4.3风机盘管水系统水力计算4.3.1基本公式4.3.1.1沿程阻力△Pe=ξe·v2·ρ/2gmH2O(4.1)沿程阻力系数ξe=0.025·L/d(4.2)4.3.1.2局部阻力水流动时遇弯头、三通及其他配件时,因摩擦及涡流耗能而产生的局部阻力为:△Pm=ξ·ρ·v2/2gmH2O(4.3)4.3.1.3水管总阻力△P=△Pe+△PjmH2O(4.4)4.3.1.4确定管径mm(4.5)式中:Vj——冷冻水流量,m3/s;vj——流速,m/s。在水力计算时,初选管内流速和确定最后的流速时必须满足以下要求:67 华北水利水电学院表4.2管内水的最大允许水流速表[1]公称直径:DNV(m/s)公称直径:DNV(m/s)>150.3651.15200.65801.60250.801001.80321.001252.00401.50≥1502.00-3.00501.50空调系统的水系统的管材有镀锌钢管和无缝钢管。当管径DN≤100mm时可以采用镀锌钢管,其规格用公称直径DN表示;当管径DN>100mm时采用无缝钢管,其规格用外径×壁厚表示,一般须作二次镀锌。水力计算说明书:水管水力计算(最不利环路)编号负荷kW流量m^3/h管径管长mv(m/s)R(Pa/m)Py(Pa)ζPj(Pa)Py+Pj(Pa)16.651.4040932100.56413413406901224122.594.455913210.6463233234814113739.241.589684010.784337337116950642.594.4559120100.646223223061812411512.831.907314040.75425310121728174062.592.455912030.64622366967811450715.422.65294040.56833713481489183782.592.2455912030.64622366967811450918.013.098494040.6631837321121853102.594.455912030.646223669678114501121.63.716134080.795259207211742246126.651.144093280.564234187246622534132.592.4455912520.6462234466235681149.241.589684070.784177123911691408157016.305815020.679198396112366321611516.30581504.50.6792851282.563261608.51716031.08688654.50.7952921314421215261821042.9809653.60.69253801368475321211925050.3281803.60.6982166597.6645529367 华北水利水电学院2029061.55246803.60.756161579.668259862135093.552461003.60.83475233838.8450273522410101.55251003.60.8841175630475893323470108.52461003.60.8264183658.8436654924530117.42141253.60.779246885.6696512115.新风系统设计5.1新风进口位置:本系统采用独立的新风系统,因此只须考虑风机盘管机组配置合理;布置时应尽量使排风口与进风口远离,进风口应尽量放在排风口的上风侧;为避免吸入室外地面灰尘,进风口底部应距地面不宜低于2m。5.2新风口其他要求:进风口应设防雨百叶窗,以防雨水进入,百叶窗应采用固定的百叶窗,在多雨地区,宜采用防水的百叶窗。5.3风道的布置和制作要求①风管应注意布置整齐,美观和便于维修、测试,应与其他管道统一考虑,要防止冷热源管道之间的不利影响,设计时应考虑各管道的装拆方便。②风管布置应尽量减少局部阻力,弯管中心曲率半径要不小于其风管直径或边长。一般采用1.25倍直径或边长。③风管法兰间应放置具有弹性的垫片,如海绵橡胶、橡皮等,以防止漏风,风管与风管之间不应有看得见的孔洞。④风管涂漆。本系统设计时选用镀锌薄板钢板,可以不涂漆,但咬口损坏处要涂漆,施工时已发现锈蚀时要涂漆。5.4百叶送风口的选择步骤①绘制系统轴测图,标注各段长度和风量。当气流组织及风口位置确定后,接下来就是布置风管,通过风管将各个风口连接起来,为风口提供一个输送空气的渠道。②选定最不利环路(一般是指最长或局部构件最多的分支管路)。③根据房间空调风机盘管送风量和使用场合要求的风口颈部最大风速来确定送风速度和百叶风口的尺寸。④67 华北水利水电学院将选到的其他参数的要求,例如允许噪声,进行校核。若噪声超出,则重新选择风口。按所选的风口的参数,对其进行射程的校核计算。5.5风口的选择5.5.1气流组织设计计算由于房间的使用功能,气流组织采用侧送风的形式,二层的准备间,三、四层的豪华包厢外采用顶送的气流组织形式。图例:5.5.1.1选定送风口形式拟采用双层百叶送风口,其紊流系数为ɑ=0.16,射程为3m(0.5m为射流末端宽度)。5.5.1.2选取送风温差Δt根据民航大楼风机盘管选型计算中送风温差的确定方法,得出Δt=7℃。5.5.1.3定送风口的出流速度v0m/s(5.1)式中:Fn——垂直于单股射流的空间断面面积,m2,见(5.2)d0——送风口直径或当量直径,m。(5.2)式中:H——房间高度,m;B——房间宽度,m;67 华北水利水电学院L——房间的总送风量,m3/h;先假定v0=3m/s,由公式(5.2)算出射流自由度0为12.33,代入公式(5.1)=0.36×12.33=4.44m/s。所取v0=3m/s<4.44m/s,且在2~5m/s范围之间,则满足要求。5.5.1.4确定送风口数目N(5.3)式中:a——送风口紊流系数;x——送风射流的射程,m;——受限射流无因次距离,见式(5.4)式中其他符号含义同上。取Δtx=1℃,由(Δtx/Δt0)×()=(1/10)×12.33=1.233,查得受限射流距离=0.25;由公式(5.4)N=2.8×4.2/[0.16×3/0.25]2=1.08,因此风口数目N为1个。5.5.1.5确定送风口尺寸由下式算得每个风口面积m2(5.5)式中:——送风口面积;5.5.1.6校核射流的贴附长度阿基米德数Ar按下式计算:67 华北水利水电学院(5.6)式中:——射流出口温度,K;——房间空气温度,K;——风口面积当量直径,m;——重力加速度,m/s2;式中其他符号含义同上。由Ar数的绝对值查得x/d0值,就可以得到射流贴附长度x。5.5.1.7校核房间高度公式H=h+w+0.07·x+0.3m,房间高度>=H为满足要求;(5.7)式中:h——空调区高度,一般取2m;w——送风口底边至顶棚距离,m;0.07·x——射流向下扩展的距离,m;0.3——安全系数,m。H=h+w+0.07·x+0.3=2.0+0.40+0.07×3+0.3=2.91<3.3m符和要求。(5.11)新风系统水利计算风管水力计算(假定流速法)1.计算依据67 华北水利水电学院假定流速法是以风道内空气流速作为控制指标,计算出风道的断面尺寸和压力损失,再按各环路间的压损差值进行调整,以达到平衡。2.计算公式a.计算摩擦阻力系数的公式采用的是柯列勃洛克-怀特公式。b.管段损失=沿程损失+局部损失即:Pg=ΣPl+ΣPd。c.Pdn=Pd1+Σ(Pm×L+Pz)。3.计算结果新风风管水力计算表(假定流速法)第一层新风管道编号风量(m^3/h)风速(m/s)Rm(Pa/m)宽(mm)高(mm)长(m)局部阻力系数ζ动压Pd(Pa)局部阻力P1(Pa)摩擦阻力Rm*l总阻力P(pa)管段1129.631.2712012017.10.45.42.1621.71723.877管段2129.631.271201202.60.625.43.3483.3026.65管段3259.264.561601204.04-0.0521.6-1.0818.422417.3424管段4129.631.271201202.60.625.43.3483.3026.65管段5388.863.851601604.04-0.0521.6-1.0815.55414.474管段6129.631.271201202.60.625.43.3483.3026.65管段7518.463.172501204.04-0.0521.6-1.0812.806811.7268管段8129.631.271201202.60.625.43.3483.3026.6564862.222502002.70.621.612.965.99418.95467 华北水利水电学院管段9112.9742当前最不利环路总阻力为112.9742Pa第二层新风管道编号风量(m^3/h)风速(m/s)Rm(Pa/m)宽(mm)高(mm)长(m)局部阻力系数ζ动压Pd(Pa)局部阻力P1(Pa)摩擦阻力Rm*l总阻力P(pa)管段1129.631.271201209.10.45.42.1611.55713.717管段2129.631.271201203.120.945.45.0763.96249.0384管段386.431.271201203.120.945.45.0763.96249.0384管段4345.663.171601204.8-0.054.04-1.0815.21614.136管段586.431.271201203.120.945.45.0763.96249.0384管段643263.442001200.8-0.0521.6-1.082.7521.672管段7259.230.952001206.50.945.45.0766.17511.251管段8691.262.482501600.6-0.0521.6-1.081.4880.408管段986.431.271201203.120.945.45.0763.96249.0384管段10777.662.12502001.7-0.0521.6-1.083.572.4979.8276当前最不利环路总阻力为79.8276Pa第三层新风管道编号风量(m^3/h)风速(m/s)Rm(Pa/m)宽(mm)高(mm)长(m)局部阻力系数ζ动压Pd(Pa)局部阻力P1(Pa)摩擦阻力Rm*l总阻力P(pa)管段1129.631.271201203.70.45.42.164.6996.859管段2129.631.271201203.0950.625.43.3483.930657.27865管段3259.264.561601204.04-0.0521.6-1.0818.422417.3424129.631.271201203.0950.625.43.3487.2786567 华北水利水电学院管段43.93065管段5388.863.852001204.04-0.0521.6-1.0815.55414.474管段6129.631.271201203.0950.945.45.0763.930659.00665管段7129.631.271201203.0950.945.45.0763.930659.00665管段864862.221601602.7-0.0521.6-1.085.9944.914管段9129.631.271201203.0950.945.45.0763.930659.00665管段10129.631.271201203.0950.945.45.0763.930659.00665管段11907.261.272501207-0.0521.6-1.088.897.81管段12172.831.271201203.0950.945.45.0763.930659.00665管段13129.631.271201203.0950.945.45.0763.930659.00665管段141209.631.572502001.996-0.0521.6-0.273.133722.86372管段15259261.543202506.70.621.612.9610.31823.278管段16302.430.872501206.850.45.42.165.95958.1195管段17129.631.271201203.0950.625.43.3483.930657.27865管段1843263.851601201-0.0521.6-1.083.852.77管段19129.631.271201203.0950.625.43.3483.930657.27865561.663.442001207-0.0521.6-1.0824.082367 华北水利水电学院管段20管段21129.631.271201203.0950.945.45.0763.930659.00665管段22129.631.271201203.0950.945.45.0763.930659.00665管段23820.863.171601607-0.0521.6-1.0822.1921.11管段24129.631.271201203.0950.945.45.0763.930659.00665管段25129.631.271201203.0950.945.45.0763.930659.00665管段26108063.132501207-0.0521.6-1.0821.9120.83管段27129.631.271201203.0950.625.43.3483.930657.27865管段281209.661.682002001-0.0521.6-1.081.680.6管段29172.831.271201203.0950.625.43.3483.930657.27865管段301382.461.572502006.042-0.0521.6-1.089.485948.40594288.8363当前最不利环路总阻力为288.8363Pa第四层新风管道编号风量(m^3/h)风速(m/s)Rm(Pa/m)宽(mm)高(mm)长(m)局部阻力系数ζ动压Pd(Pa)局部阻力P1(Pa)摩擦阻力Rm*l总阻力P(pa)管段1129.631.2712012010.950.45.42.1613.906516.0665管段2129.631.271201203.0950.625.43.3483.930657.27865259.263.851601201-0.0521.6-1.083.852.7767 华北水利水电学院管段3管段4129.631.271201203.0950.625.43.3483.930657.27865管段5388.863.442001207-0.0521.6-1.0824.0823管段6129.631.271201203.0950.625.43.3483.930657.27865管段7518.463.442501200.745-0.0521.6-1.082.56281.4828管段8172.831.271201203.0950.625.43.3483.930657.27865管段9691.263.132501601.24-0.0521.6-1.083.88122.8012管段10302.461.543202506.70.621.612.9610.31823.278管段11129.631.271201206.80.45.42.168.63610.796管段12129.631.271201203.0950.625.43.3483.930657.27865管段13259.263.851601601-0.0521.6-1.083.852.77管段14129.631.271201203.0950.625.43.3483.930657.27865管段15388.863.442501206.6-0.0521.6-1.0822.70421.624管段16129.631.271201203.0950.945.45.0763.930659.00665管段17129.631.271201203.0950.945.45.0763.930659.00665管段1864863.172001601-0.0521.6-1.083.172.09管段19129.631.271201203.0950.945.45.0763.930659.0066567 华北水利水电学院管段20129.631.271201203.0950.945.45.0763.930659.00665管段21907.263.132502007-0.0521.6-1.0821.9120.83管段22129.631.271201203.0950.625.43.3483.930657.27865管段231036.861.683201601-0.0521.6-1.081.680.6管段24172.831.271201203.0950.625.43.3483.930657.27865管段251209.661.573202506.013-0.0521.6-1.089.440418.36041230.7247当前最不利环路总阻力为230.7247Pa第五层新风管道编号风量(m^3/h)风速(m/s)Rm(Pa/m)宽(mm)高(mm)长(m)局部阻力系数ζ动压Pd(Pa)局部阻力P1(Pa)摩擦阻力Rm*l总阻力P(pa)管段1129.631.271201204.220.45.42.165.35947.5194管段2129.631.271201203.0950.945.45.0763.930659.00665管段3129.631.271201203.0950.945.45.0763.930659.00665管段4388.863.442001207-0.0521.6-1.0824.0823管段5129.631.271201203.0950.945.45.0763.930659.00665管段6129.631.271201203.0950.945.45.0763.930659.00665管段764863.171601601-0.0521.6-1.083.172.09管段8129.631.271201203.0950.945.45.0763.930659.00665129.631.271201203.0950.945.45.0769.0066567 华北水利水电学院管段93.93065管段10907.263.132501207-0.0521.6-1.0821.9120.83管段11129.631.271201203.0950.945.45.0763.930659.00665管段12129.631.271201203.0950.945.45.0763.930659.00665管段131166.462.772502001-0.0521.6-1.082.771.69管段14129.631.271201203.0950.625.43.3483.930657.27865管段15129662.482502001.987-0.0521.6-1.084.927763.84776管段16129.631.271201203.0950.45.42.163.930656.09065管段17129.631.271201203.0950.625.43.3483.930657.27865管段18259.263.442001201-0.0521.6-1.083.442.36管段19129.631.271201203.0950.945.45.0763.930659.00665管段20129.631.271201203.0950.945.45.0763.930659.00665管段21518.463.172001607-0.0521.6-1.0822.1921.11管段22129.631.271201203.0950.945.45.0763.930659.00665管段23129.631.271201203.0950.945.45.0763.930659.0066567 华北水利水电学院管段24777.663.132501601-0.0521.6-1.083.132.05管段25129.631.271201203.0950.945.45.0763.930659.00665管段26129.631.271201203.0950.945.45.0763.930659.00665管段271036.862.772502007-0.0521.6-1.0819.3918.31管段28129.631.271201203.0950.625.43.3483.930657.27865管段291166.462.392002001-0.0521.6-1.082.391.31管段30129.631.271201203.0950.625.43.3483.930657.27865管段31129662.12502006.027-0.0521.6-1.0812.656711.5767管段32259261.485002506.6-0.0521.6-1.089.7688.688281.8325当前最不利环路总阻力为281.8325Pa第九层新风管道编号风量(m^3/h)风速(m/s)Rm(Pa/m)宽(mm)高(mm)长(m)局部阻力系数ζ动压Pd(Pa)局部阻力P1(Pa)摩擦阻力Rm*l总阻力P(pa)管段1129.631.271201204.220.45.42.165.35947.5194管段2129.631.271201203.0950.945.45.0763.930659.00665管段3129.631.271201203.0950.945.45.0763.930659.00665管段4388.863.442001207-0.0521.6-1.0824.082367 华北水利水电学院管段5129.631.271201203.0950.945.45.0763.930659.00665管段6129.631.271201203.0950.945.45.0763.930659.00665管段764863.171601601-0.0521.6-1.083.172.09管段8129.631.271201203.0950.945.45.0763.930659.00665管段9129.631.271201203.0950.945.45.0763.930659.00665管段10907.263.132501207-0.0521.6-1.0821.9120.83管段11129.631.271201203.0950.945.45.0763.930659.00665管段12129.631.271201203.0950.945.45.0763.930659.00665管段131166.462.772001601-0.0521.6-1.082.771.69管段14129.631.271201203.0950.625.43.3483.930657.27865管段15129662.482501601.987-0.0521.6-1.084.927763.84776管段16129.631.271201203.0950.45.42.163.930656.09065管段17129.631.271201203.0950.625.43.3483.930657.27865管段18259.263.442001201-0.0521.6-1.083.442.36管段19129.631.271201203.0950.945.45.0763.930659.00665管段20129.631.271201203.0950.945.45.0763.930659.0066567 华北水利水电学院管段21518.463.171601607-0.0521.6-1.0822.1921.11管段22129.631.271201203.0950.945.45.0763.930659.00665管段23129.631.271201203.0950.945.45.0763.930659.00665管段24777.663.132501201-0.0521.6-1.083.132.05管段25129.631.271201203.0950.945.45.0763.930659.00665管段26129.631.271201203.0950.945.45.0763.930659.00665管段271036.862.772001607-0.0521.6-1.0819.3918.31管段28129.631.271201203.0950.625.43.3483.930657.27865管段291166.462.392002001-0.0521.6-1.082.391.31管段30129.631.271201203.0950.625.43.3483.930657.27865管段31129662.12502006.027-0.0521.6-1.0812.656711.5767管段32259261.485002506.6-0.0521.6-1.089.7688.688281.8325当前最不利环路总阻力为281.8325Pa全空气系统水力计算:(假定流速法)67 华北水利水电学院风管水力计算1.计算依据假定流速法是以风道内空气流速作为控制指标,计算出风道的断面尺寸和压力损失,再按各环路间的压损差值进行调整,以达到平衡。2.计算公式a.计算摩擦阻力系数的公式采用的是柯列勃洛克-怀特公式。b.管段损失=沿程损失+局部损失即:Pg=ΣPl+ΣPd。c.Pdn=Pd1+Σ(Pm×L+Pz)。3.计算结果送风管水力计算(一层左下)编号风量(m^3/h)风速(m/s)Rm(Pa/m)宽(mm)高(mm)长(m)局部阻力系数ζ动压Pd(Pa)局部阻力P1(Pa)摩擦阻力Rm*l总阻力P(pa)管段149630.58250200110.45.42.166.388.54管段299230.4332025060.925.44.9682.587.548管段3148861.684002004.5-0.0521.6-1.087.566.4867 华北水利水电学院管段499230.4332025050.925.44.9682.157.118管段549630.58250200110.45.42.166.388.54管段6248161.275002504-0.0521.6-1.085.084管段749630.582502502.50.625.43.3481.454.798管段849630.58250200110.45.42.166.388.54管段9297761.1763025040.621.612.964.6817.6473当前最不利环路总阻力为73.204Pa送风管水力计算(一层右下)编号风量(m^3/h)风速(m/s)Rm(Pa/m)宽(mm)高(mm)长(m)局部阻力系数ζ动压Pd(Pa)局部阻力P1(Pa)摩擦阻力Rm*l总阻力P(pa)管段149630.5825020080.45.42.164.646.8管段249630.582502005.50.45.42.163.195.35管段3992260.4332025040.9221.619.8721.7221.592管段499230.4332025060.45.42.162.584.74管段549630.5825020080.45.42.164.646.8198561.343202504.521.6-1.086.034.9567 华北水利水电学院管段6-0.05管段799230.4332025050.45.42.162.154.31管段849630.5825020080.45.42.164.646.8管段9297761.174002504-0.0521.6-1.084.683.6管段1049630.582502002.50.45.42.161.453.61管段11347361.015002004-0.0521.6-1.084.042.9671当前最不利环路总阻力为71.512Pa送风管水力计算(一层右上)编号风量(m^3/h)风速(m/s)Rm(Pa/m)宽(mm)高(mm)长(m)局部阻力系数ζ动压Pd(Pa)局部阻力P1(Pa)摩擦阻力Rm*l总阻力P(pa)管段158930.525025030.45.42.161.53.66管段258930.525025030.45.42.161.53.66管段3117861.853202004.5-0.0521.6-1.088.3257.245管段458930.525025030.45.42.161.53.66管段558930.525025030.45.42.161.53.662357361.275002504.5-0.0521.6-1.085.7154.63567 华北水利水电学院管段6管段758930.525025030.45.42.161.53.66管段858930.525025030.45.42.161.53.66管段9353660.8950040030.821.617.282.6719.9553当前最不利环路总阻力为53.79Pa送风管水力计算(二层左下)编号风量(m^3/h)风速(m/s)Rm(Pa/m)宽(mm)高(mm)长(m)局部阻力系数ζ动压Pd(Pa)局部阻力P1(Pa)摩擦阻力Rm*l总阻力P(pa)管段145130.5825020020.555.42.971.164.13管段245130.5825020020.555.42.971.164.13管段390362.223201607-0.0521.6-1.0815.5414.46451管段445130.5825020020.555.42.971.164.13管段545130.5825020020.555.42.971.164.13管段6180761.345002004.6-0.0521.6-1.086.1645.084管段7903.93532.223201609.50.35.41.6221.0922.71管段8451.967530.582502002.880.45.42.161.67043.830467 华北水利水电学院管段9903.93532.2232016030.45.42.166.668.82管段10451.530.582502002.880.45.42.161.67043.8304管段113615.7460.895004004.10.621.612.963.64916.60991当前最不利环路总阻力为91.8638Pa送风管水力计算(二层右下)编号风量(m^3/h)风速(m/s)Rm(Pa/m)宽(mm)高(mm)长(m)局部阻力系数ζ动压Pd(Pa)局部阻力P1(Pa)摩擦阻力Rm*l总阻力P(pa)管段1451.930.582502008.60.45.42.164.9887.148管段245130.582502004.60.625.43.3482.6686.016管段3903.9562.223201604-0.0521.6-1.088.887.8管段4451530.582502004.60.625.43.3482.6686.016管段5135561.853202004-0.0521.6-1.087.46.32管段645130.582502004.60.625.43.3482.6686.016管段7180761.545002004-0.0521.6-1.086.165.08管段8903.93532.223201602.880.45.42.166.39368.5536451.967530.5825020030.45.42.161.743.967 华北水利水电学院管段9管段10271131.174003204-0.055.4-0.274.684.41管段11903.93532.223201602.880.45.42.166.39368.5536管段12451.967530.5825020030.45.42.161.743.9管段133615.7460.895004005-0.0521.6-1.084.453.3777当前最不利环路总阻力为77.0832Pa送风管水力计算(四层左下)编号风量(m^3/h)风速(m/s)Rm(Pa/m)宽(mm)高(mm)长(m)局部阻力系数ζ动压Pd(Pa)局部阻力P1(Pa)摩擦阻力Rm*l总阻力P(pa)管段1314.87530.8725012020.625.43.3481.745.088管段2314.87530.8725012020.625.43.3481.745.088管段3629.7561.762501604-0.0521.6-1.087.045.96管段4314.87530.8725012020.625.43.3481.745.088管段5314.87530.8725012020.625.43.3481.745.088管段61259.561.194002004-0.0521.6-1.084.763.68管段7314.87530.8725012020.625.43.3481.745.088314.87530.8725012020.625.43.3481.745.08867 华北水利水电学院管段8管段91889.2560.95002004-0.0521.6-1.083.62.52管段10314.87530.8725012020.625.43.3481.745.088管段1131430.8725012020.625.43.3481.745.088管段12251960.995003204-0.0521.6-1.083.962.8855当前最不利环路总阻力为55.744Pa6通风防排烟设计6.1设计说明本建筑高度为34.2米。楼梯间采用加压送风防烟。需设置独立的送风系统。楼梯间正压为50Pa,每隔一层设一送风口,送风口采用铝合金百页风口。6.1.1需要进行防烟设计的建筑及部位《高层建筑防排烟设计规范》:①对于高层建筑(建筑物高度超过32米的二类建筑),面积超过100平方米且四周无窗时或使用面积超过500平方米的地下商场等,应设防烟、排烟设施。②防烟楼梯间及其前室、消防电梯前室和合用前室,应设独立的防烟、排烟设施。③无直接天然采光和自然通风且长度超过30m的内走道或有直接采光和自然通风,但长度超过60m的内走道也应设防烟、排烟设施。排烟设施的目的是排除火灾初期产生的烟气,利于避难活动和消防活动。该建筑不需要做防排烟,因为走廊的长度37m,且有外窗,外窗的面积大于走廊面积的2%,电梯和楼梯前室有外窗,其面积也很大,且前室的面积也很小,自然通风就可以了。6.1.2加压送风具体设计楼梯间设置加压送风系统。送风量:5400M3/h,选一台DZ13型5B型号轴流风机,风量为5500立方米每小时,全压为125pa。风速4.2m/s67 华北水利水电学院各卫生间采用排风扇进行排风,排出的卫生间气体进入风井。7风冷热泵、板式换热器的布置7.1机组选型因为制冷系统的冷负荷530KW,选用三台WTF19.2H型号的风冷热泵机组,单台制冷量为192KW.工作原理:蒸汽进入壳体中的立管内,均匀的分配至各悬臂管,放出热量成冷凝水排出,水进入壳体后,在挡板作用下分散,经多层盘管依次加热后从出水管引出。蒸汽在盘管内高速流动,其离心作用力推动盘管产生高频浮动,促使管内外被加热水产生扰动,破坏管-水间的层流,强化了对流换热,换热系数大大提高了。其技术经济特点是运行的智能化程度高;运行的可靠性高;安装使用方便、插上电源即可使用,自动除垢,阻力小;结构紧凑,外型尺寸小;传热效果好;噪声低;具有夏季供冷水和冬季供热水的双重功能,对于我国幅员辽阔的国土而言,相当大的地区属于夏季需制冷而冬季需制热的范围,这种风冷热泵就特别适用;因为供热系统的热负荷为458kw,选用一台RPKT-2型号的板式换热器。工作原理:板式换热器是由一系列具有一定波纹形状的金属片叠装而成的一种新型高效换热器。各种板片之间形成薄矩形通道,通过半片进行热量交换。它与常规的管壳式换热器相比,在相同的流动阻力和泵功率消耗情况下,其传热系数要高出很多,在适用的范围内有取代管壳式换热器的趋势。板式换热器的特点(板式换热器与管壳式换热器的比较)a.传热系数高由于不同的波纹板相互倒置,构成复杂的流道,使流体在波纹板间流道内呈旋转三维流动,能在较低的雷诺数(一般Re=50~200)下产生紊流,所以传热系数高,一般认为是管壳式的3~5倍。b.对数平均温差大,末端温差小在管壳式换热器中,两种流体分别在管程和壳程内流动,总体上是错流流动,对数平均温差修正系数小,而板式换热器多是并流或逆流流动方式,其修正系数也通常在0.95左右,此外,冷、热流体在板式换热器内的流动平行于换热面、无旁流,因此使得板式换热器的末端温差小,对水换热可低于1℃,而管壳式换热器一般为5℃.67 华北水利水电学院c.占地面积小板式换热器结构紧凑,单位体积内的换热面积为管壳式的2~5倍,也不像管壳式那样要预留抽出管束的检修场所,因此实现同样的换热量,板式换热器占地面积约为管壳式换热器的1/5~1/10。d.容易改变换热面积或流程组合,只要增加或减少几张板,即可达到增加或减少换热面积的目的;改变板片排列或更换几张板片,即可达到所要求的流程组合,适应新的换热工况,而管壳式换热器的传热面积几乎不可能增加。e.重量轻板式换热器的板片厚度仅为0.4~0.8mm,而管壳式换热器的换热管的厚度为2.0~2.5mm,管壳式的壳体比板式换热器的框架重得多,板式换热器一般只有管壳式重量的1/5左右。f.价格低采用相同材料,在相同换热面积下,板式换热器价格比管壳式约低40%~60%。g.制作方便板式换热器的传热板是采用冲压加工,标准化程度高,并可大批生产,管壳式换热器一般采用手工制作。h.容易清洗框架式板式换热器只要松动压紧螺栓,即可松开板束,卸下板片进行机械清洗,这对需要经常清洗设备的换热过程十分方便。i.热损失小板式换热器只有传热板的外壳板暴露在大气中,因此散热损失可以忽略不计,也不需要保温措施。而管壳式换热器热损失大,需要隔热层。j.容量较小是管壳式换热器的10%~20%。k.单位长度的压力损失大由于传热面之间的间隙较小,传热面上有凹凸,因此比传统的光滑管的压力损失大。l.不易结垢由于内部充分湍动,所以不易结垢,其结垢系数仅为管壳式换热器的1/3~1/10.m.工作压力不宜过大,介质温度不宜过高,有可能泄露板式换热器采用密封垫密封,工作压力一般不宜超过2.5MPa,介质温度应在低于250℃以下,否则有可能泄露。n.易堵塞由于板片间通道很窄,一般只有2~5mm,当换热介质含有较大颗粒或纤维物质时,容易堵塞板间通道7.1.1.1该系统机组的设计工况冷冻水进水温度为12℃,出水温度为7℃。热水进水温度60℃,出水温度50℃。67 华北水利水电学院7.1.2分水器和集水器的构造和用途分水器和集水器实际上是一段大管径的管子,在其上按设计要求焊接上若干不同管径的管接头,在集中供水(供冷和供热)系统中,采用集水器和分水器的目的是有利于空调分区的流量分配和调节,亦有利于系统的维修和操作。确定分水器和集水器的原则是使水量通过集管时的流速大致控制在0.5~0.8m/s范围之内。分水器和集水器一般选择标准的无缝钢管(公称直径DN200~DN500)。供水集管又称分水器(或分水缸),回水集管又称集水器(或回水缸),它们都是一段水平安装的大管径钢管。冷水机组生产的冷水送入供水集管,再经供水集管向各支系统或各分区送水,各支系统或各分区的空调回水,先回流至回水集管,然后由水泵送入冷水机组。供回水集管上的各管路均应设置调节阀和压力表,底部应设置排污阀或排污管(一般选用DN40)。供回水集管的管径按其中水的流速为0.5~1m/s范围确定。管长由所需连接的管的接头个数、管径及间距确定,两相邻管接头中心线间距为两管外径+1200mm,两边管接头中心线距集管断面宜为管外径+60mm。7.2循环水泵的选型和计算7.2.1水泵的选型和计算根据选型原则,选择三台冷冻水泵(两用一备)。7.2.1.1水泵流量的确定WTF19.2H型号单台风冷热泵机组的额定水流量为127.8m3/h根据水泵工作时,取流量储备系数=1.2。则单台水泵设计流量V=1.2*127.8153.36m3/h;v=1.2*77.6=93.12m3/h.7.2.1.2水泵扬程H的确定水泵扬程H按下式计算:H=·Hmax(7.2)式中:H——水泵扬程,m;Hmax——水泵所承担的最不利环路的水压降,mH2O;——扬程储备系数取=1.1。总压降67 华北水利水电学院为供回水管网最不利环路的水压降,可以按照以下公式估算水泵的扬程:Hmax=△P1+△P2+0.05·L·(1+K)mH20(7.3)式中:△P1——冷水机组蒸发器的水压降,mH20;△P2——最不利环路并联空调末端装置中水压损失最大者的水压降,mH20;K——最不利环路中局部助力当量长度总和与该环路管道总度的比值,本设计K=0.6[1]。根据《中央空调设计实训教程》[1]附录,选用三台IS150-125-200型水泵,其流量为Q1=200m3/h,扬程为55mH2O,电机功率为32KW,转速为2900r/min。7.3循环水泵配管布置进行水泵的配管布置时,应注意以下几点:7.3.1安装软性接管:在连接水泵的吸入管和压出管上安装软性接管,有利于降低和减弱水泵的噪声和振动的传递。7.3.2出口装止回阀:目的是为了防止突然断电时水逆流而时水泵受损。水泵的吸入管和压出管上应分别设进口阀和出口阀;目的是便于水泵不运行能不排空系统内的存水而进行检修。7.3.3水泵阀件安装:水泵的出水管上应装有温度计和压力表,以利检测。如果水泵从地位水箱吸水,吸水管上还应该安装真空表。水泵基础高出地面的高度应小于0.1m,地面应设排水沟。67 华北水利水电学院致谢在本次设计过程中,参阅并引用了大量的国内外有关科技文献和技术资料,在此向所引用的参考文献的作者致意;李老师在这次设计中给了我许多指导性的建议,让我在设计过程中少走了很多弯路,可以说我的毕业设计能够顺利完成,在很大程度上归于李老师的悉心指导,在这里特向李老师表示真诚的感谢;另外,建环教研室的其他各位老师设计过程中也给了我很大帮助,在此一并表示感谢;最后向设计过程中一同进步的各位同学致以真诚的谢意。67 华北水利水电学院外文翻译Aboutwarmlypassestheair-conditioningsystemtheenergyconservationquestionAlongwiththeeconomicalrapiddevelopment,theenergyandtheenvironmentquestionaredaybydayincisive.Inthespeciallyburninghotsummer,weallpersonalrealizedelectricpoweranxiety.Mayforesee,thiskindofconditioninalsowillbeabletoappearfromnowon,andwillbeabletobedaybydayserious.First,warmlypassestheairconditioningdomainenergyconservationtheimportanceandthefeasibilityAlongwithsociety"sdevelopment,constructionenergyconsumptiontheproportionwhichoccupiesinthetotalenergyconsumptionismoreandmorebig,hasachieved40%inthedevelopcountry,alsoachieves27.8%accordingtothestatisticsinHunanProvince.Farishigherthanthisproportioninthecity.Butintheconstructionenergyconsumption,usesinwarmlypassingairconditioningtheenergyconsumptiontooccupytheconstructionenergyconsumption30%-50%,alsoisrisingyearbyyear.Increasesunceasinglyalongwiththeaverageperpersonfloorspace,warmlypassestheair-conditioningsystemthewidespreadapplication,willuseinwarmlypassingtheair-conditioningsystemtheenergyconsumptionfurthertoincrease.Thiswillbeabletocausetheenergysupplyanddemandcontradictoryfurtherintensificationinevitably.Ontheotherhand,existingwarmlypassestheenergywhichtheair-conditioningsystemusesbasicallyisthehighgradenon-renewableenergy,electricalenergyhasaccountedfortheabsoluteproportion.Totheseenergymassiveuses,causestheearthresourcetobedaybydaydeficient,atthesametimealsobringstheseriousenvironmentquestion,likeinourcountry"ssomelocalacidrains,theflyashquestionassumesdaybydaytheseriouspotential,hasbroughttheverytremendousinfluencetotheecologicalenvironmentandthesustainabledevelopment.TaketheHunanChangshaareaastheexample,in2003summertheelectricalpowersystem67 华北水利水电学院biggestloadprobablyis1.6millionkilowatts,calculatedaccordingtothedepartmentconcerned,air-conditioningsystemloadhasaccountedforapproximately600,000kilowatts.Inhottestsummer,iftowarmlypassestheair-conditioningsystemtotaketheenergyconservationmeasure,notonlymayalleviatetheelectricpowerintenseconditiongreatly,atthesametimeregardingreducesthenon-renewableenergytheconsumption,theprotectionecologicalenvironment,maintainsthesustainabledevelopment,promotestheHunaneconomyandsoonalltohavethevitalsignificance.Accordingtowarmlypassestheairconditioningprofessiontheresearchresults,theexistingair-conditioningsystemenergyconsumptionisastonishing,ifusestheenergyconservationtechnology,theexistingair-conditioningsystemconservesenergy20%-50%iscompletelypossible.Obviously,ifusestheenergyconservationmeasuretheChangshaareaair-conditioningsystemandthebuildingsystem,thenevenifmeetsthissummersuchburninghotweather,Changshaouldnotsurpasstheexistingelectricalpowersystempeakvaluebutpowercut.Second,warmlypassesairconditioningdomainenergyconservationthewayandthemethod.Thescienceandtechnologyunceasingprogress,causeswarmlytopasstheairconditioningdomainnewtechnologyappearunceasingly,wemayrealizethroughthemanykindsofmethodswarmlypasstheair-conditioningsystemtheenergyconservation.1st,carefullydesignswarmlypassestheair-conditioningsystem,causesittomoveinunderthehighlyeffectiveeconomicalconditionWarmlypassestheair-conditioningsystemspeciallyisthecentralair-conditioningsystemishugecomplexsystem,thesystemdesignfitandunfitqualityaffectsdirectlysystemoperationalperformance.Forexamplethesystemoftenallisaccordingtothebiggestloaddesign,butactualmovesbasicallyismovesunderthepartialloads,ifsystemeachpartofdesignscannotsatisfythepartialloadsmovementtherequest,thatsystemenergyconsumptionisverybig.Alsolikethenewatmospheresystemdesign,thesystemshouldbeablechangethenewamountofwindalongwithoutdoormeteorologicalparameterchange,bymaximumlimitreducesthemainengineopenthetime.Maysaytheair-conditioningsystemthedesigntothesystemenergy67 华北水利水电学院conservationvitalrole.2nd,theimprovementconstructionmaintenancestructureheatpreservationperformance,reducesthecoldheatlosWeknewregardingwarmlypassestheair-conditioningsystemtosay,holdstheverygreatproportionthroughthemaintenancestructureairconditioningload,butmaintainsthestructureheatpreservationperformancedecisionmaintenancestructuresynthesisheattransfercoefficientsize,thatisdecisionthroughmaintenanceairconditioningloadsize.Thereforeinconstructionenergyconservationdesignstandardandstandardwhichappearsinthecountry,firstrequestsisenhancesthemaintenancestructuretheheatpreservationheatinsulationperformance.3rd,raisesthesystemscontrollevel,theadjustmentroominternalheatwetenvironmentparameter,reducestheair-conditioningsystemenergyconsumptionasfaraspossible.Theair-conditioningsystemisspeciallycomfortableair-conditioningsystemtothehumanbodyfunctionisthroughairtemperature,thehumidity,thewindspeed,theenvironmentaverageradiationtemperaturecarrieson,humanbodyenvironmentLengRefeltistheseenvironmentalfactorcombinedactionsresults.Theformerairconditioningcontrolmodeismerelyobservesandcontrolstheairthetemperature,evenonlyairtemperature.Obviouslyisnotcomprehensive,willbringmanyquestionsinevitably,likeair-conditioningsystemtohumanbodyfunctionnotdirect,whenenvironmentalvariationtotheenvironmentregulationnotrapid,thehumanbodyfeltwillnotbecomfortable,theair-conditioningsystemthisregulativewaydoesnotconserveenergy.Thehotwetenvironmentalresearchachievementapplication,usedthenewcontrolmodemethodforustoprovidetherationale.Ifusesthecomfortableappraisaltargetisthebodyfeelingtargettooktheair-conditioningsystemtheregulativeparameter,likeusesPMVortheSETtargetcarriesontheregulationtotheair-conditioningsystem,notonlymaysolvethetraditioncontrolmethodexistencedisease,moreovermayrealizethelargescaleenergyconservation,indicatedaccordingourspreliminarystudy,usescontrolmethodtobepossibletocausetheair-conditioningsystemtoconserveenergyabout30%underthehumanbody67 华北水利水电学院comfortablecondition.4th,usesthenewenergyconservationcomfortablehealththeairconditioningway.Accordingstated,affectsthehumanvolumetricheatcomfortableenvironmentparametertobemultitudinous,differentenvironmentparametercombinationmayobtainsamehotcomfortableeffect,thedifferentheatwetenvironmentparametercombinationair-conditioningsystemenergyconsumptionisnotsame.Forexampleinwinter,ifweusetraditionaltheairconditioningway,heatsuptheentireroominair,throughtheairrealizationhumanbodyandtheenvironmentheatwetexchange,needsthehighairtemperature,thistimeheatsupthenewatmospherethroughthemaintenancestructurelossofheatdisagreedeclarewarheatquitetobeallbig.Ifweaccordingtothehotwetenvironmenttheresearchresults,changetraditionairconditioningway,theincreaseradiatingheat(forexamplelowtemperaturefloorradiationheating),needstheairtemperaturedropremarkabledrop,amountto12~14generally,butthetraditionalwayin18~20,obviouslylatterhastheremarkableenergyconservationeffectgenerallycomparedtoformer.Alsohasthesimilarresultinthesummer.5th,promotedapplicationusesrenewableenergyorthelow-gradeenergyair-conditioningsystem.Alongwiththeair-conditioningsystemwidespreadapplication,theairconditioninglargescalewillrisetothenon-renewableenergyconsumption,atthesametimealsodaybydaywillbeintensifyingtotheecologicalenvironmentdestruction.Howusedtherenewableenergyandthelow-gradeenergyhasalreadybecomethisdomainimportantresearchtopic.Thesourceheatpumpair-conditioningsystemisunderthiskindofsituation,itsnaturalresourcesundergroundstratospheresoilhotremarkablyenhancestheair-conditioningsystemtheCOPvalue,causesthesamelevelsystemtobehot(orrefrigeration)underquantitysystemenergyconsumptionlargescaledrop.Moreover,heatsorrefrigerationtechnologyusingthesolarenergyalsoisstudyinginthedevelopment.6th,carriesoutcoldheatrecoveryusetheresearchutilizationwork,therealizationenergymaximumlimituseAtpresentmanyair-conditioningsystemscoldheatrecoveryalsovigorouslyis67 华北水利水电学院developingusingtheresearch,likeair-conditioningsystemrowofwindentireheatrecovery,summerusestheheatofcondensationthehygienichotwatersupplyandsoon,allistothesystemLengRerecyclinguse,remarkablyraisedtheair-conditioningsystemenergyusefactor.Third,existencequestionandcountermeasureMustrealizeair-conditioningsystemenergyconservationtofallconsumes,hasalreadymetmanymaturerequirements,butatthesametimealsohasmanyproblemstowaitforthesolution.1st,warmlypassestheair-conditioningsystemthedesignmanagementquestion.Asmentionedabove,theair-conditioningsystemdesignhastheimportantinfluencetotheair-conditioningsystemenergyconservation.Howeverinactualcenteroftencannotobtainsomedesigndepartmentsanddesignsthepersonnelenoughtotake,causethedesignconstructionthesystemnotonlyatthebeginningoftoinvestinabigway,themovementenergyconsumptionquiteisalsoastonishing,hassurpassedthenationalstandardgreatly.Accordingtoactual,somepublicbuildingsconditioningenergyconsumptionoccupyconstructtotalenergyconsumption60%.Therefore,wehavethenecessitytosuggestthegovernmentrelatedfunctiondepartmentstrengthenstowarmlypassestheairconditioningdesignprojectthemanagement,mayentrustthecorrelationtechnologydepartmentlikeacademicsocietyandsoontocarryonstrictexaminationtothedesignpaperdocument,hadnotachievedthenationalrelatedenergyconservationstandardthedesignstrictlyprohibitstheconstructionconstruction. 2nd,warmlypassestheair-conditioningsystemthemovementmanagementquestion.Besidesthedesign,wediscoveredthemovementmanagementalsoisplayingthevitalrole.Someunits"air-conditioningsystem,throughouttheyearonlythenopenstheinstitutionmachineandewintersummertransformstheoperation,obvioussystemcannotachievethecorrespondingenergyconservationeffect.Notonlymusthavetheintensesenseofresponsibilityforthisrequestmovementadministrativepersonnelfront,postsalsomusthavetocarrythesystemtrainingandtheinspection,hadnotachievedtherequest,shouldretrain,aftertheinspectionisqualifiedcanpost.Wediscoveredininvestigationthat,thesamesetofsystems,theadministrativepersonnel67 华北水利水电学院tobedifferent,systemenergyconsumptionentirelydifferent,someevendiffersabove50%.3rd,newairconditioningway,controlmethodandnewenergyconservationtechnologydevelopmentapplicationquestionAsmentionedabove,selectsthenewairconditioningmethod,thenewcontrolmethod,notonlycanremarkablyraisethehighfevercomfortablenessmoreovertobepossibletocausethesystemlargescaleenergyconservation.Inourprovincetothenewairconditioningwayandthecontrolmethodresearchmaysayinthenationallisquiteearly,andhasalreadyyieldedsomeencouragingresults,solongasthegovernmentdepartmentwillsupporttheseachievementstobeveryquickslightlycanobtainissuitable,andformtheindustrialproduction,totheseprojectsimplementations,toourprovinceenergy,theenvironmentandtheeconomyallwillplaytohugeimpetusrole.4th,publictoair-conditioningsystemfunctionunderstandingideaquestion.Regardingcomfortableair-conditioningsystem,saysfromthisspecializedangleisenablethehumanbodytohavegoodhotcomfortableness.Butwediscoversonesuchideafrequentlyinthesociety:Thoughttheairconditioningthecolderwinterthermaleffectisbetterinthesummer.Thisviolatesobviouslywithcomfortableairconditioningstartingpoint.Infact,notonlygreatlyhasincreasedtheair-conditioningsystemenergyconsumptionlikethis,atthesametimebecauseinsideandoutsideroomtemperaturedifferenceincreasing,alsocausehumanbodythedifferentenvironmentcompatibledrop,thebodilyimmunitytoreduce.Thesemaychangepeople"sideathroughthepropaganda.5th,usesrenewableenergyair-conditioningsystemthedevelopmentpromotionapplicationquestion.Usestherenewableenergywarmlypasstheair-conditioningsystem,likesourceheatpumpair-conditioningsystem,solarenergyrefrigeration,heatingsystem,notonlyhastheremarkableenvironmentandthesocialefficiency,somealsohastheremarkableeconomicefficiency(forexamplesourceheatpumpair-conditioningsystem),shoulddevelopthepromotionvigorously.Certainly,issamewithotherany67 华北水利水电学院newtechnologies,thesetechnologiesalsohavesomeproblems(forexamplesourceheatpumpsystemplacesourcehotlytowithdrawquestionandsoon),alsoneedsfurthertostudyconsummates,alsoneedsthegovernmentdepartmentthevalueandthesupport.Insummary,warmlypassestheair-conditioningsystemtooccupytheimportantpositionintheconstructionenergyconservation,isplayingthevitalrole,energyconservationtechnologyresearchdevelopmentandtheutilizationiswarmlypassestheair-conditioningsystem,buildingsystemenergyconservationfoundation,governmentfunctiondepartment"svalueandthesupport,thenrealizesthelargescaleenergyconservation,producestheremarkableenvironmentandthesocialefficiency,theimpetuseconomydevelopmentguarantee.67 华北水利水电学院关于暖通空调系统的节能问题随着经济的迅速发展,能源和环境问题日益尖锐。在特别炎热的夏天,我们都切身地体会到了电力的紧张。可以预见,这种状况在今后还会出现,并且会日趋严重。1.1.1.1一、暖通空调领域节能的重要性和可行性随着社会的发展,建筑能耗在总能耗中所占的比例越来越大,在发达国家已达到40%,据统计在湖南省也达到27.8%。在城市远高于这个比例。而在建筑能耗里,用于暖通空调的能耗又占建筑能耗的30%-50%,且在逐年上升。随着人均建筑面积的不断增大,暖通空调系统的广泛应用,用于暖通空调系统的能耗将进一步增大。这势必会使能源供求矛盾的进一步激化。另一方面,现有的暖通空调系统所使用的能源基本上是高品位的不可再生能源,其中电能占了绝对比例。对这些能源的大量使用,使得地球资源日益匮乏,同时也带来严重的环境问题,如在我国的一些地区酸雨、飘尘问题呈日益严重之势,对生态环境和可持续发展带来了很大影响。以湖南长沙地区为例,2003年夏季电力系统最大负荷大约为160万千瓦,据有关部门推算,其中空调系统的负荷就占了约60万千瓦。在最热的夏天,如果对暖通空调系统采取节能措施,不仅可以大大缓解电力紧张状况,同时对于降低不可再生能源的消耗、保护生态环境、维持可持续发展、振兴湖南经济等都有着重要的意义。根据暖通空调行业的研究成果,现有空调系统的能耗是惊人的,如果采用节能技术,现有空调系统节能20%-50%完全可能。显然,如果对长沙地区的空调系统和建筑系统采用节能措施,那么即使遇到今夏那样的炎热天气,长沙也不会超过现有电力系统峰值而停电了。67 华北水利水电学院1.1.1.1二、暖通空调领域节能的途径与方法科学技术的不断进步,使暖通空调领域新的技术不断出现,我们可以通过多种方法实现暖通空调系统的节能。1、精心设计暖通空调系统,使其在高效经济的状况下运行暖通空调系统特别是中央空调系统是一个庞大复杂的系统,系统设计的优劣直接影响到系统的使用性能。例如系统往往都是按最大负荷设计的,而实际运行基本上是在部分负荷下运行,如果系统各部分的设计不能满足部分负荷运行的要求,那系统的能耗是很大的。又如新风系统的设计,系统应该能随着室外气象参数的变化改变新风量,以最大限度地缩短主机的开启时间。可以说空调系统的设计对系统的节能起着重要的作用。2、改善建筑维护结构的保温性能,减少冷热损失我们知道对于暖通空调系统而言,通过维护结构的空调负荷占有很大比例,而维护结构的保温性能决定维护结构综合传热系数的大小,亦即决定通过维护结构的空调负荷的大小。所以在国家出台的建筑节能设计规范和标准中,首先要求的就是提高维护结构的保温隔热性能。3、提高系统控制水平,调整室内热湿环境参数,尽可能降低空调系统能耗67 华北水利水电学院空调系统特别是舒适性空调系统对人体的作用是通过空气温度、湿度、风速、环境平均辐射温度进行的,人体对环境的冷热感觉是这些环境因素综合作用的结果。以往的空调控制方式仅仅是测控空气的温度湿度,甚至仅空气温度。显然是不全面的,势必带来许多问题,如空调系统对人体的作用不直接、当环境变化时对环境的调控不迅速、人体感到不舒适、空调系统的这种调控方式不节能。热湿环境研究成果的应用,为我们采用新的控制方式方法提供了理论基础。如果采用舒适性评价指标即体感指标作为空调系统的调控参数,如采用PMV或SET*指标对空调系统进行调控,不仅可以解决传统控制方法存在的弊病,而且可以实现大幅度的节能,据我们的初步研究表明,采用这种控制方法可使空调系统在人体舒适的条件下节能30%左右。4、采用新型节能舒适健康的空调方式如上所述,影响人体热舒适性的环境参数众多,不同的环境参数组合可以得到相同的热舒适性效果,但不同的热湿环境参数组合空调系统的能耗是不相同的。例如在冬季,如果我们采用传统的空调方式,把整个室内的空气加热,通过空气实现人体与环境的热湿交换,就需要较高的空气温度,此时通过维护结构的热损失和加热新风的热损失都比较大。如果我们根据热湿环境的研究成果,改变传统的空调方式,增加辐射热(如低温地板辐射采暖),此时所需要的空气温度降显著下降,一般可达到12~14度,而传统方式一般在18~20度,显然后者比前者具有显著的节能效果。在夏季也有类似的结果。5、推广应用使用可再生能源或低品位能源的空调系统随着空调系统的广泛应用,空调对不可再生能源的消耗将大幅度上升,同时对生态环境的破坏也在日趋加剧。如何利用可再生能源及低品位能源已经成了该领域重要的研究课题。地源热泵空调系统就是在这种形势下发展起来的,它利源地下恒温层土壤热显著提高空调系统的COP值,使得同等制热(或制冷)量下的系统能耗大幅度下降。另外,利用太阳能供热或制冷技术也在开发研究着。6、开展冷热回收利用的研究运用工作,实现能源的最大限度利用目前许多空调系统冷热回收利用研究也在蓬勃开展,如空调系统排风的全热回收器,夏季利用冷凝热的卫生热水供应等,都是对系统冷热的回收利用,显著提高了空调系统能源利用率。1.1.1.1三、存在的问题与对策要实现空调系统的节能降耗,已经具备了许多成熟的条件,但同时也存在许多问题有待于解决:67 华北水利水电学院1、暖通空调系统的设计管理问题如前所述,空调系统的设计对空调系统的节能性有着重要的影响。然而在实际中往往得不到一些设计部门和设计人员的足够重视,使得设计建造的系统不仅初投资大,运行能耗也相当惊人,大大超过了国家标准。据实测,有的公共建筑的空调能耗占建筑总能耗的60%。为此,我们有必要建议政府有关职能部门加强对暖通空调设计项目的管理,可以委托相关技术部门如学会等对设计图纸文件进行严格审查,对未达到国家有关节能标准的设计严禁施工建造。2、暖通空调系统的运行管理问题除设计外,我们发现运行管理也起着重要的作用。有些单位的空调系统,一年四季只有开机关机和冬夏季转换操作,显然系统达不到相应的节能效果。为此要求运行管理人员不仅要有强烈的责任心,上岗前还必须要进行系统的培训和考核,对没有达到要求的,应重新培训,考核合格后才能上岗。在调查中我们发现,同样一套系统,管理人员不同,系统的能耗大不相同,有的甚至相差50%以上。3、新型空调方式、控制方法及新的节能技术的开发应用问题如前所述,采用新型空调方式、新的控制方法,不仅能显著提高热舒适性而且可以使系统大幅度节能。在我省对新型空调方式和控制方法的研究可以说在全国都是比较早的,并且已经取得了一些可喜的成果,只要政府部门略加扶持这些成果将很快能得到适用,并形成产业化,对这些项目的实施,将对我省的能源、环境和经济都将起到巨大的推动作用。4、公众对空调系统作用的理解观念问题对于舒适性空调系统,从本专业的角度来讲就是使人体有好的热舒适性。而在社会上我们常常发现一种这样的观念:认为空调在夏季是越冷冬季越热效果越好。这显然与舒适性空调的出发点相违背的。事实上,这样不仅大大增大了空调系统的能耗,同时由于室内外温差的增大,也使人体对不同环境的适应性下降,身体免疫力降低。这些可以通过宣传改变人们的观念。67 华北水利水电学院5、使用可再生能源空调系统的开发推广应用问题利用可再生能源的暖通空调系统,如地源热泵空调系统、太阳能制冷、供热系统,不仅有着显著的环境和社会效益,有的还有着显著的经济效益(如地源热泵空调系统),应大力开发推广。当然,和其他任何新技术一样,这些技术也存在着一些问题(如地源热泵系统的地源热提取问题等),也需要进一步研究完善,也需要政府部门的重视和支持。综上所述,暖通空调系统在建筑节能中占据重要的位置,起着重要的作用,节能技术的研究开发和运用是暖通空调系统、建筑系统节能的基础,政府职能部门的重视和支持,则是实现大幅度节能、产生显著的环境和社会效益、推动经济发展的保证。67 华北水利水电学院参考文献[1]《采暖通风与空气调节设计规范》(GBJ1—03)[2]《高层民用建筑设计防火规范》(GB50176—03)[3]《民用建筑热工设计规范》(全国民用建筑工程设计技术措施)(GB50176—03)[4]《采暖通风与空气调节制图标准》(GBJ114—03)[5]马最良等;《民用建筑空调设计》;化学工业出版社2003版[6]杨昌智等;《暖通空调工程设计方法与系统分析》;中国建筑工业出版社2001版[7]陆耀庆等;《实用供热空调设计手册》;中国建筑工业出版社1993版[8]长沙泛华中央空调研究所;《中央空调工程精选图集》;中国电力出版社2004版[9]陆亚俊、马最良、邹平华等;《暖通空调》;中国建筑工业出版社2002版[10]付祥钊、王岳人;《流体输配管网》;中国建筑工业出版社2001版[11]VentilationSystem,IndoorAirQuality,andHealthOutcomesinParisianModernOfficeWorkers.Vincent,D.;Annesi,I.;Festy,B.;Lambrozo,J.67'