• 361.50 KB
  • 14页

山东产业园剪力墙结构高层住宅楼桩基工程临电施工方案

  • 14页
  • 当前文档由用户上传发布,收益归属用户
  1. 1、本文档共5页,可阅读全部内容。
  2. 2、本文档内容版权归属内容提供方,所产生的收益全部归内容提供方所有。如果您对本文有版权争议,可选择认领,认领后既往收益都归您。
  3. 3、本文档由用户上传,本站不保证质量和数量令人满意,可能有诸多瑕疵,付费之前,请仔细先通过免费阅读内容等途径辨别内容交易风险。如存在严重挂羊头卖狗肉之情形,可联系本站下载客服投诉处理。
  4. 文档侵权举报电话:19940600175。
'WiththeShaanxiExpresswaynetworkingtoll,tollextensionbusinessisnowweighingchargesforstoragechargesdatabasesecurityandbackupofbusinessdatahasbecomemoreprominent.Aftertwoyearsofoperation,moreandmoreawarenessoftheoperatingunitstodatabasestabilityissuesisaproblemnottobeignored.Simpleexamplessuchas:failureoftheserversanddatabases,generalmaintenanceandmanagementstaff,inmanycases,cannotbeindependentandquickrecovery,hadanimpactonproduction.Soweneedaproperdatabackupsolutions.Databaseisthecoreofthewholesystem,databasesecurityshouldpaymoreattention.Therefore,theformulationofappropriatedatabasebackupstrategy,istomaintaindatabasesecuritynormsaswellastheguidelines,tobackupthedataitneedsfromthetechnical,aswellasadministrativelyregulated.Indatasecurity,datasecuritystrategyistomaintaintheintegrity,confidentialityandavailabilityofinformation.Therefore,databasesecuritypolicywillfocusonthesethreepoints,includingphysicalsecurity,accesscontrol,databackupandemergencyresponse.Here,inthetollcollectionsystemintheprovinceusestheSQLServerdatabaseasanexampletoillustratetheideaofdevelopingitssecuritypolicy.1researchbackgroundofconstructionofnetworkedExpresswaytollcollectionsystemreducedthenumberofdriversvehiclesintheroadnetworkandimproveroadcapacity,reducingenvironmentalpollutionduetoparking,enhancetheeconomicbenefitsofHighwayandsocialimage.ShaanxiProvincialExpresswaynetworkingtollbeganinMay2004,asofnowtherearemorethan200dataserver,asmoresectionsofgrid-connectedcharges,chargesdataasthecoreofthewholesystem,itisnecessarytoestablishasetofdatasecurityandreliablesolution.2purposethistimethroughtheanalysisofnetworkdatainserverhealth,ShaanxiProvincialExpresswaynetworkingtollsystembasedondata,statisticalmethodsofdatastorage,dataresearch,originalchargeaspossiblesecurity,integrityandprivacyofdata.Fortheopeningsectionafterincorporationfeesprovideareliablesetofdatasecuritypolicies.3databasesecuritysituationintheprovinceShaanxiProvincialExpresswaynetworkingtollsystemoverview3.1database-tiersystems,managementsystems,branch-levelmanagementsystem,theprovincialnetworkcentresplitandtransfersystem,four-levelsystem.Eachsystemhasitsownseparatedataserverisusedtostoretheircollectionofpremiumbusinessdata,providethebasisforstatisticalanalysis.1,stand-levelserverstoragefeescollectedfromtolllanesflowingdataandpassonthissiteblessingKaku,cartridgeinformationwithinthissite,cardboxallocation,cartridgecombinationofinformationandfrequencyinformation.2,themainstorageserverserverchargescollectedwaterfromunderthejurisdictionofthestationdataandthepassofblessingKaku,theinternalcartridgeinformation,reallocationofthecartridgeandcartridgecombination,personnelinformation,flightinformation,chargestheactualpaymentdataentrywork.3,Center-classserverstorageserverchargescollectedwaterfromunderthejurisdictionofthestationdataWaterdataintegritycanbeupandrunning.Sowhenadatabaseserverfails,youdonotneedtopassdatatorecover,simplythroughthecollectionprocedureforchargingwaterdatacollectiontocompletethefastrecoveryofserverfailures.4.4analysissummarysummaryanalysis,lanebecauseitisnotacompletestationleveldata,sothereisnoneedfordedicatedbackup.Stand-levelserverdatabecauseitisatthefrontofthechargeasawhole,itsfaultdirectlyaffectstheexercisenormally,youneedacompleteoffsitebackupsolution.Management,anddatacenterserver,duetoitsoperationswithoutmanualdataentry,sojustusecommonartificialscheduledbackupscanbe.5solutionsinordertoensurethatwhentheserverafterahardwarefailover,backupdatawithoutchangesoronlyminorchangescanbequickandeasytroubleshootingofserverdatarecovery,you青岛游艇产业园区C-1-8地块工程临电施工方案(桩基)中国建筑第二工程局有限公司2013年12月15日needtoselectthereal-timesynchronizationmethodoftheprogramme.Typicallybackupsystemcomeswithbackupsolutionsshouldbepreferred.Ifthesystemcomeswithabackupplanifitcannotmeettherequirements,softwaredevelopmentmethodsisneeded.Orthird-partysoftwaresystemsareselectedforbackup.Becausethird-partybackupsoftwareisusuallypricedveryhigh,chargingunitsrequirehighprice,soforonlythefirsttwomethodsarestudiedbelow.5.1useMSSQL2000synchronizedbackupsofSQL2000databaseinthreeways,namelysnapshotreplication,transactionalreplicationandmergereplication.Bycomparison,excludingthefirsttwoprogrammes,selectsynchronizationtransactionalreplicationanddatabaseNothwinddatabase,forexample,fortesting.Thethreepartsofthemainconsiderationsinthesynchronizationofthedata,canbethoughtofasthreehosts.ThePublisher,Distributor,andSubscriber;canbeunderstoodfromtheliteralmeaning,functionisactuallyimplementedtokeepsubscribersthroughtheDistributordatatimelyandconsistentdataatthePublisher.1,aboutsnapshotreplicationtocopydatachangesinfrequently,orarenotrequiredtokeepthedatacurrentvalues(lowlatency),snapshotdataisoneofthebestmethodsofdatareplication.Whensynchronizationoccurs,completesnapshotisgeneratedandsenttotheSubscriber.Becausesnapshotreplicationbulkcopiesreleased(itemscollection)acompletecopy,itwillpublishallwritesmadetothesnapshotfolder.Projectistospecifythatyouwanttocopytables,datapartitioning,ordatabaseobjects.Projectscanbeafulltableandcertaincolumns(usingaverticalfilter),certainrows(usingahorizontalfilter),astoredprocedureorviewdefinition,thestoredprocedureexecution,view,indexed,view,oruser-definedfunction.Snapshotreplicationdoesnotmaintaindatathefastestreal-timeupdates,andthebulkcopyreleased(itemscollection)afullcopyofthemechanismwillgeneratealotofnetworktraffic.Onlysmallvolumesofreplicationused,dataisstaticanddoesnotneedtobeupdatedinrealtimedatabase.SodonotusesnapshotreplicationthesynchronizationmodeDatatable,addanewdatafieldMSrepl_tran_version,publishingsoftwaredependingonwhetherthecontentsofthisfieldchangestodeterminewhetheryouneedtopublishthedata.AndSQL2000dataismodifiedjudgingismanagedbythekernel,notforexternalprogramming.Suchasmodifythestructureoftheoriginaldatatable,adirectresultofrunninglanesandmanagementsoftwarethatdoesn"twork.DuetotheabovetestresultstoprovethatthisscenarioisnotsuitableasabackupmethodfornetworkingtollsysteminShaanxiProvince.5.2usingspeciallydevelopedbackupsoftwareaftertheabovetests,throughthesystem"ssubscriptions,publishmethodinShanxiprovinceunderthenetworkingsoftwaresyncbackup,demandcannotbemet,backupsoftwaresoIdecidedtouseforthedevelopmentofsynchronization,synchronizebackups.Asaresultofindependentdevelopment,ithasahighdegreeofflexibilityinbackup.Easierforseamlessintegrationwithexistingsystems.Backupsoftwaredevelopedforthesynchronization,youmustmeetthefollowingrequirements:inordertoensuresynchronousbackupsoftwarecanstartonWindowsstartup,andarenoteasilyshutdownbytheoperation,itshouldbedevelopedusingaWindowsservice.Synchronizebackupsoftwareisthesoftwarethatruns24hours,mustbeabletosteadyoperation.Inordertoreducenetworkbandwidthtothegreatestdegreeinthebackup,andonlyneedtobackupthetollingsystemgeneratesthenewdatatable.Thebackupsoftwareshouldbeabletoautomaticallyfiltertheaddnewdatainadatabasetable,andsynchronizedbackupsofdatathatmeetstheconditionsofform.FlagsfieldofthecurrentchargingsystemusingadedicatedTransferMark,anykindoftollsystemsoftwareafterchangingtherecord,bothonthefieldiszero,thisrecordhasbeenchangedtonotifyothersoftware.Usethisfieldasaflagtoidentifywhetherdatahaschanged.Inadditiontothisfield, WiththeShaanxiExpresswaynetworkingtoll,tollextensionbusinessisnowweighingchargesforstoragechargesdatabasesecurityandbackupofbusinessdatahasbecomemoreprominent.Aftertwoyearsofoperation,moreandmoreawarenessoftheoperatingunitstodatabasestabilityissuesisaproblemnottobeignored.Simpleexamplessuchas:failureoftheserversanddatabases,generalmaintenanceandmanagementstaff,inmanycases,cannotbeindependentandquickrecovery,hadanimpactonproduction.Soweneedaproperdatabackupsolutions.Databaseisthecoreofthewholesystem,databasesecurityshouldpaymoreattention.Therefore,theformulationofappropriatedatabasebackupstrategy,istomaintaindatabasesecuritynormsaswellastheguidelines,tobackupthedataitneedsfromthetechnical,aswellasadministrativelyregulated.Indatasecurity,datasecuritystrategyistomaintaintheintegrity,confidentialityandavailabilityofinformation.Therefore,databasesecuritypolicywillfocusonthesethreepoints,includingphysicalsecurity,accesscontrol,databackupandemergencyresponse.Here,inthetollcollectionsystemintheprovinceusestheSQLServerdatabaseasanexampletoillustratetheideaofdevelopingitssecuritypolicy.1researchbackgroundofconstructionofnetworkedExpresswaytollcollectionsystemreducedthenumberofdriversvehiclesintheroadnetworkandimproveroadcapacity,reducingenvironmentalpollutionduetoparking,enhancetheeconomicbenefitsofHighwayandsocialimage.ShaanxiProvincialExpresswaynetworkingtollbeganinMay2004,asofnowtherearemorethan200dataserver,asmoresectionsofgrid-connectedcharges,chargesdataasthecoreofthewholesystem,itisnecessarytoestablishasetofdatasecurityandreliablesolution.2purposethistimethroughtheanalysisofnetworkdatainserverhealth,ShaanxiProvincialExpresswaynetworkingtollsystembasedondata,statisticalmethodsofdatastorage,dataresearch,originalchargeaspossiblesecurity,integrityandprivacyofdata.Fortheopeningsectionafterincorporationfeesprovideareliablesetofdatasecuritypolicies.3databasesecuritysituationintheprovinceShaanxiProvincialExpresswaynetworkingtollsystemoverview3.1database-tiersystems,managementsystems,branch-levelmanagementsystem,theprovincialnetworkcentresplitandtransfersystem,four-levelsystem.Eachsystemhasitsownseparatedataserverisusedtostoretheircollectionofpremiumbusinessdata,providethebasisforstatisticalanalysis.1,stand-levelserverstoragefeescollectedfromtolllanesflowingdataandpassonthissiteblessingKaku,cartridgeinformationwithinthissite,cardboxallocation,cartridgecombinationofinformationandfrequencyinformation.2,themainstorageserverserverchargescollectedwaterfromunderthejurisdictionofthestationdataandthepassofblessingKaku,theinternalcartridgeinformation,reallocationofthecartridgeandcartridgecombination,personnelinformation,flightinformation,chargestheactualpaymentdataentrywork.3,Center-classserverstorageserverchargescollectedwaterfromunderthejurisdictionofthestationdataWaterdataintegritycanbeupandrunning.Sowhenadatabaseserverfails,youdonotneedtopassdatatorecover,simplythroughthecollectionprocedureforchargingwaterdatacollectiontocompletethefastrecoveryofserverfailures.4.4analysissummarysummaryanalysis,lanebecauseitisnotacompletestationleveldata,sothereisnoneedfordedicatedbackup.Stand-levelserverdatabecauseitisatthefrontofthechargeasawhole,itsfaultdirectlyaffectstheexercisenormally,youneedacompleteoffsitebackupsolution.Management,anddatacenterserver,duetoitsoperationswithoutmanualdataentry,sojustusecommonartificialscheduledbackupscanbe.5solutionsinordertoensurethatwhentheserverafterahardwarefailover,backupdatawithoutchangesoronlyminorchangescanbequickandeasytroubleshootingofserverdatarecovery,you目录1编制说明12编制依据13工程概况14现场临电平面布置14.1布置原则14.2线路布置方案25施工用电设置25.1线路设施的设置25.2配电箱设置35.3电器灯具设置35.4重复接地的设置36施工用电管理46.1施工现场用电管理46.2生活区临时用电管理46.3施工用电应急措施57安全用电措施57.1安全用电组织措施57.2安全用电技术措施67.3用电防火措施88施工用电计算108.1施工机械配置(初版,根据正试图调整)108.2总用电量计算108.3配电导线截面计算119附图:现场临电平面布置图(桩基)13中国建筑第二工程局有限公司 青岛游艇产业园区C-1-8地块临电施工方案临电施工方案1编制说明为青岛游艇产业园C-1-8地块项目桩基工程的施工临时用电提供较完整的技术指导文件,便于建筑施工临时用电的施工流程和施工质量控制,能优质、快速、高效的完成建筑施工临时用电的施工任务,并为业主、监理对工程的施工方法、质量、工程进度等各方面的详细了解提供依据。2编制依据1、业主提供游艇产业园C-1-8地块2013-12-11版CAD版结构电子版图2、《建筑工程施工现场供电安全规范》GB50194-933、《供配电系统设计规范》GB50052-20094、《施工现场临时用电安全技术规范》JGJ46-20055、《建筑施工安全检查标准》JGJ59-20113工程概况青岛游艇产业园C-1-8地块位于青岛市黄岛区前湾港附近,齐长城路北。C-1-8地块建筑面积约26万㎡,地下为一层整体地库,建筑面积约41500㎡;地上为6栋高层住宅,建筑面积约㎡,其中1#楼32层,建筑高度93.5m,2#楼32层,建筑高度93.5m,3#楼33层,建筑高度96.4m,4#楼33层,建筑高度96.4m,5#楼33层,建筑高度96.4m,6#楼34层,建筑高度99.3m。基础结构为桩基+筏板,主体为剪力墙结构。4现场临电平面布置4.1布置原则现场临时用电配线严格按三相五线制覆盖整个施工现场,工作零线(N线)和保护零线(PE线)必须严格分开。工作零线(N线)仅用于负载(即220V照明及220V用电设备使用)。施工现场所有用电设备除作保护接零(PE线)外,必须在设备负荷线的首端处设置漏电保护装置。配电线路采用熔断器作短路保护时,熔体额定电流应不大于绝缘导线允许截流量的1.5倍。配电线路采用自动开关作短路保护时,其过电流脱扣器,脱扣电流整定值,应不小于线路末端单相短路电流,并应能承受短路时过负荷电流。中国建筑第二工程局有限公司第11页 青岛游艇产业园区C-1-8地块临电施工方案临电总电源由业主现场地块安装的8个容量为630KVA的箱变提供,临时供电系统采用树状辐射埋地分布,至各临时用电机械设备及二级配电箱再至各开关箱。考虑用电紧张通过计算合理分配各用电设备的作业时间,以确保作业的正常进行。1.1线路布置方案施工临时用电主要考虑现场机械使用、照明用电及办公生活区用电。总电源位于地块施工区的东西面,为8台630KVa厢式变压器,整个现场用电设配电箱,引入各施工用电区。各楼层用电由电缆线加套管沿建筑物墙面垂直敷设而上,在各楼层设置三级箱及开关箱,供楼层使用。现场采用三级配电,两级防护系统及三相五线制配线原则。用电分桩基及结构施工两个阶段设置。1、桩基施工桩基施工阶段机械设备数量级用电量较大,现场设28个配电总柜(一级箱1~6#配630A总开,7~28#配315A总开),630A总开一级箱每台设计负责4台桩机用电,315A一级箱每台设计负责2台桩机用电,同时315A一级箱负责现场加工棚及照明等用电。630A总开一级箱采用YJV-4×240+1×120主电缆同箱变连接;315A总开一级箱采用YJV-4×120+1×70主电缆同箱变连接。(该配置充分考虑公司内部调配及新电缆采购相结合的方案,最大的节约电缆使用)2、结构施工待正式施工图下发,结构开始施工前7天内编制并上报。2施工用电设置2.1线路设施的设置根据现场施工条件,电缆的采取埋地配管暗设,严禁沿地面明设,电缆穿越道路,易受机械损伤的场所及引出地面从2m高度至地下0.2m处,必须加设保护套管。埋地敷设电缆的接头应设在地面上的接线盒内,接线盒应能防水、防尘、防机械损伤并应远离易燃、易爆、易腐蚀场所。电缆在直接埋地敷设的深度应不小于0.8m,并在电缆上下各均匀铺设不小于50mm厚的细纱,然后铺盖砖等硬质保护层。中国建筑第二工程局有限公司第11页 青岛游艇产业园区C-1-8地块临电施工方案现场电缆采取沿基坑上口绕地块一圈设置,办公、生活区沿围墙埋地至办公区生活区。1.1配电箱设置1、本工程所设置的配电箱、开关箱为厚度1.5mm铁板制作的标准配电箱。配电箱、开关箱应装设端正、牢固,移动式配电箱、开关箱应装设在坚固的支架上。2、配电系统设置室内总配电屏(配电室)和室外分配电箱,实行分级配电。3、开关箱为末级分配电箱配电,分配电箱与开关箱的距离不得超过30m。开关箱与其控制的固定式用电设备的水平距离不宜超过3m。4、配电箱、开关箱的开关电器(含插座)应按其规定的位置紧固在电器安装板上,不得歪斜和松动,配电箱、开关箱内的工作零线应通过接线端子板连接,并应与保护零线(地线)接线端子板,配电箱、开关箱内的连接线应采用绝缘导线,接头不得松动,不得有外露带电部分,配电箱和开关箱的金属箱体、金属电器以及箱内电器的不应带电金属底座、外壳等必须保护接地,接地线应通过接线端子板连接。配电箱、开关箱必须防雨、防尘。5、总配电室、总配电箱,室外分配电箱均设置总开关和分路开关及漏电保护器。6、每台用电设备均设置各自专用的开关箱,实行“一机一箱一闸一漏”制。7、开关箱内设置漏电保护器,其额定漏电动作电流应不大于30mA,额定漏电动作时间应不小0.1S。8、配电箱、开关箱中导线的进线口和出线口均设在箱体的下底面,进出线加保护套成束并做防水弯。移动式配电箱和开关箱的进出线采用橡皮绝缘电缆。9、固定式配电箱、开关箱的下底与地面的垂直距离应大于1.3米,小于1.5米,移动式配电箱、开关箱的下底与地面垂直距离应大于0.6米,小于1.5米,进出口一律设在箱体的下底,并有防绝缘损坏措施(可采用加缠二层塑料绝缘带)。1.2电器灯具设置电器、灯具的相线必须经开关控制,不得将相线直接引入灯具。施工现场办公室、加工房内配线必须采用绝缘导线,严禁采用护导线直接配线,且全部配线穿PVC管。施工机械和移动碘钨灯应加防雨罩配电缆线。中国建筑第二工程局有限公司第11页 青岛游艇产业园区C-1-8地块临电施工方案1.1重复接地的设置1、现场临时供电系统采用TN-S接零保护系统,在施工现场临时分配电箱处设专用保护接地线(PE线)直接接地,接地体Φ48钢管,Φ12圆钢连接,接地电阻实测值不大于3Ω。专用保护零线(PE线)由中性点直接引入,工作零线(N线)与保护零线(PE线)分开,不得连接;所有电气的金属外壳必须与专用保护零线(PE线)连接。2、施工现场的电力系统严禁利用大地作相线和零线,保护零线(PE线)不得装设开关或熔断器,保护零线(PE线)的截面,应不小于工作零线(N线)的截面,同时必须满足机械强度要求,与电气设备相连接保护零线(PE线)应为相线截面的1/2或不小于2.5㎜2的绝缘多股铜线。保护零线(PE线)的统一标志为绿/黄双色线,在任何情况下不准使用绿/黄双色线作负荷线。3、施工现场内所有防雷装置的接地电阻值实测值不大于3Ω,各种机械设备的防雷引线可利用该设备的金属结构体,但应保证电气连接可靠。4、总配电箱进线处和变压器低压母线上应装设低压避雷器,施工现场和临时生活区,高压在20m以上的脚手架、正在施工的建筑物以及塔式起重机、机具、建筑用大钢模板等都要用防雷接地保护,避雷针长度1~2米,可用φ16圆钢端部磨尖。避雷针保护范围按60°遮护角防护。2施工用电管理2.1施工现场用电管理1、现场用电管理设专职电工两名,各用电设备实行专人专机,并经培训教育后方可操作,按规定配备劳保用品。2、建立电工岗位责任制,现场要严格执行。3、用电管理人员应经常检查电气装置,保证设施完好,并做好记录。4、专职电工,必须对配电箱、开关箱作好管理,不得转让他人管理。5、专职电工及管理人员要及时做好技术交底,做好电设备的验收,接地电阻测试,技术资料的收集整理工作。2.2生活区临时用电管理1、配电室必须配备足够的绝缘灭火器材,灭火器材应放在方便易取的地方。灭火器材应定期检查,过期失效应立即更换。中国建筑第二工程局有限公司第11页 青岛游艇产业园区C-1-8地块临电施工方案2、值班人员不得离开工作岗位,发现超负荷或其他隐患时应予以消除。严禁配电过负荷或带病运行。3、不得在电线上挂杂物及衣物等物品。4、一旦发生电气火灾,首先必须切断电源,防止在灭火过程中发生触电事故;其次要用绝缘性能好的灭火剂灭火。现场设备相应灭火器(二氧化碳、干粉等灭火器及足够的黄砂)。1.1施工用电应急措施考虑施工现场实际突发现状,现场配备一台500KW柴油发电机,供紧急使用。发电机房搭设防噪声棚,在发电机房单独设一组重复接地装置,接地电阻实测值不大于3Ω。1.2现场箱变及高压电缆防护1、现场箱变防护(1)对现场的箱变均进行防护,箱变基础四周外扩1.8m范围进行100mm厚C15砼硬化,防护临时采用48x2.8mm钢管及密目安全网,钢管立柱L=1800mm@2000mm,设上中下三道横杆。(2)正式开工后,所有箱变换装工具式成品防护,防护为方钢立柱+密目钢丝网(网眼小于3cm),顶棚为双层50mm厚木跳板硬防护,并在侧面安装单开门及上锁专人管理。每天专职电工进行检查维护,并做检查记录,电工必须有入网操作证。2、箱变高压电缆防护现场箱变专用高压电缆已由供电局埋地敷设完毕,埋深约1m。现场施工时,采用高压电缆标识牌及砼桩进行标识,施工中严禁触碰,基坑土方开挖施工时严禁触碰电缆,开挖土方距离电缆一侧2m范围内采用人工开挖探沟后再进行人工开挖。2安全用电措施2.1安全用电组织措施1、建立临时用电施工组织设计和安全用电技术措施的编制、审批制度,并建立相应的技术档案。2、建立技术交底制度中国建筑第二工程局有限公司第11页 青岛游艇产业园区C-1-8地块临电施工方案向专业电工、各类用电人员介绍临时用电施工组织设计和安全用电技术措施的总体意图、技术内容和注意事项,并应在技术交底文字资料上履行交底人和被交底人的签字手续,注明交底日期。3、建立安全检测制度从临时用电工程竣工开始,定期对临时用电工程进行检测,主要内容是:接地电阻值,电气设备绝缘电阻值,漏电保护器动作参数等,以监视临时用电工程是否安全可靠,并做好检测记录。4、建立电气维修制度加强日常和定期维修工作,及时发现和消除隐患,并建立维修工作记录,记载维修时间、地点、设备、内容、技术措施、处理结果、维修人员、验收人员等。5、建立工程拆除制度建筑工程竣工后,临时用电工程的拆除应有统一的组织和指挥,并须规定拆除时间、人员、程序、方法、注意事项和防护措施等。6、建立安全检查和评估制度施工管理部门和企业要按照JGJ59-2011《建筑施工安全检查标准》定期对现场用电安全情况进行检查评估。7、建立安全用电责任制对临时用电工程各部位的操作、监护、维修分片、分块、分机落实到人,并辅以必要的奖惩。8、建立安全教育和培训制度定期对专业电工和各类用电人员进行用电安全教育和培训,凡上岗人员必须持有劳动部门核发的上岗证书,严禁无证上岗。1.1安全用电技术措施1、建立健全的用电管理制度,各处设立专职的值班电工,配合安全员对临时用电进行管理。值班电工必须持证上岗,经常对现场的电气线路和设备进行安全检查,定期测试电气绝缘、接地接零电阻、漏电保护器等开关是否完好。并做好业内资料,台讯季节要强化检查,对查出的问题限期整改。2、建立对总配电室、各路配电箱、供电线路及电气设备检查、维修、保养等安全管理制度,严禁电气设备带病运行。3、在总配,分配和(移动)开关箱分别设置漏电断路器,实行“三级配电,二级保护”及“一机一闸一漏一箱一锁”中国建筑第二工程局有限公司第11页 青岛游艇产业园区C-1-8地块临电施工方案,末级配电箱漏电动作电流小于等于30MA(手动工具、潜水泵等小型设备漏电动作电流为15MA)脱扣时间小于等于0.1秒。所有漏电断路器均采用具有三级保护(或二级保护)功能是DZ15L型漏电开关。4、采用TN-C-S(TN-S)系统供电,总配供电,总配电盘、Ⅱ级配电箱及系统末端配电箱均设置重复接地,其接地电阻不应大于4Ω。重复接地可利用建筑物基础,或采用Φ50*4钢管,长度2500MM,垂直打入地下,要求接地极埋入地下距地面600MM,接地极距离建筑物、人行道、操作棚大于3M,以降低跨步电压。5、电源进出线电缆应遵循下进下出的原则,在箱内经固定后分别接配电箱的L、N、PE各端。视负载额定容量,正确选择熔体,使熔断器可靠的、有效的起到短路保护和断开点的作用。熔体应采用合格的铅合金熔丝,严禁用铁丝、铝丝等非专用熔丝替代,严禁用多股熔丝代替一根较大熔丝。6、电源接入配电箱后,必须先检测再使用:不接负荷,分别合闸,依次检测每一漏电断路器,试验按钮应迅速自动分闸,断开电源,操纵手柄退回到“分”或“0”位置为合格。配电箱周围必须无杂物,有操作位置。7、配电箱投入正常使用后,应由专业人员每月测试一次,并作书面记录。各级配电箱明确专人负责,做好检查维修和清洁工作。箱内应保持整洁,不准存放任何东西,箱周围应保持通道的畅通。施工现场的固定露天电箱、分配电箱必须架空设置,其底边距地高度不小于0.6米。8、所有配电箱必须符合郑州市有关规定,具有合格证,配好门锁,做好跨接,总配电箱、分配电箱下口应三面封闭,做好油漆,露天配电箱应搭好双层防坠棚。9、遵守送电、停电的操作程序:用电——总开关——分路开关——电源末端用的漏电开关;停电,反之操作。10、凡断路器合不上闸,自动跳闸,禁止强行合闸,应查出原因、排除故障后才能合闸送电。选用配电箱应计算匹配、负载的额定电流应小于控制箱额定电流,机械限位必须接入箱内标注“限位接线”处。11、主干电缆必须用五芯橡皮电缆,保护零线严禁通过任何开关和熔断器,与工作零线不可混用。重复接地必须加在PE线上。12、现场总配、分配都应做好重复接地,塔吊、人货电梯均应做好重复接地和防雷接地,其接地电阻值不得大于规定值。中国建筑第二工程局有限公司第11页 青岛游艇产业园区C-1-8地块临电施工方案13、所有电气设备的保护零线应以并联方式与零干线连接。零线的断面不应小于相线载流量的一半,零线上不准装设开关和熔断器,单相电气设备必须设置单独的保护零线,不得利用设备自身的工作零线兼做接零保护。14、移动式碘钨灯的金属灯架应有可靠的接地(接零)保护和漏电开关保护,灯具距地不低于2.4m。15、电缆直埋后应每隔10M设电缆标志桩,所有电源电缆均应在配电箱内设有标牌标明电缆去向、规格型号及敷设长度等。手持电动工具必须选用П类工具,必须有额定漏电电流不大于30mA,动作时间不大于0.1s的漏电开关保护。16、室内垂直干线应采用护套电缆,其固定点间距不大于3m,不准直接绑扎在金属支架上。职工宿舍、办公室线路必须按规范要求架设,严禁将插座与扳把开关靠近装设,严禁在床沿装设床头灯和插座。17、现场应在电气设备处悬挂醒目的警告标志。电气设备的维护和安装均由持证上岗的专业电工完成,而且在操作或维修时必须设有专人监护作业。并对检修回路挂牌警示。18、外电防护措施(1)建筑物(脚手架)的外侧边缘与外电架空线路的边线之间的安全操作距离必须符合规范要求,否则必须采取可靠的防护措施(编制外电防护专项方案)增设屏障、遮拦、围栏、保护网等,并悬挂醒目的标志牌。架设防护设施时,应有电气工程技术人员和专职安全员监护并应保证与线路的安全距离,以保证安全使用。(2)外电线在塔吊回转半径内,必须对塔吊回转或行走小车进行限位,防止触电事故的发生。1.1用电防火措施1、施工现场发生火灾的主要原因(1)、电气线路过负荷引起火灾线路上的电气设备长时间超负荷使用,使用电流超过了导线的安全载流量。这时如果保护装置选择不合理,时间长了,线芯过热使绝缘层损坏燃烧,造成火灾。(2)、线路短路引起火灾中国建筑第二工程局有限公司第11页 青岛游艇产业园区C-1-8地块临电施工方案因导线安全部距不够,绝缘等级不够,所久老化、破损等或人为操作不慎等原因造成线路短路,强大的短路电流很快转换成热能,使导线严重发热,温度急剧升高,造成导线熔化,绝缘层燃烧,引起火灾。(3)、接触电阻过大引起火灾导线接头连接不好,接线柱压接不实,开关触点接触不牢等造成接触电阻增大,随着时间增长引起局部氧化,氧化后增大了接触电阻。电流流过电阻时,会消耗电能产生热量,导致过热引起火灾。(4)、变压器、电动机等设备运行故障引起火灾变压器长期过负荷运行或制造质量不良,造成线圈绝缘损坏,匝间短路,铁芯涡流加大引起过热,变压器绝缘油老化、击穿、发热等引起火灾或爆炸。(5)、电热设备、照灯具使用不当引起火灾电炉等电热设备表面温度很高,如使用不当会引起火灾;大功率照明灯具等与易燃物距离过近引起火灾。(6)、电弧、电火花引起火灾电焊机、点焊机使用时电气弧光、火花等会引燃周围物体,引起火灾。施工现场由于电气引发的火灾原因决不止以上几点,还有许多,这就要求用电人员和现场管理人员认真执行操作规程,加强检查,可以说是可以预防的。2、预防电气火灾的措施针对电气火灾发生的原因,施工组织设计中要制定出有效的预防措施(1)施工组织设计时要根据电气设备的用电量正确选择导线截面,从理论上杜绝线路过负荷使用,保护装置要认真选择,当线路上出现长期过负荷时,能在规定时间内动作保护线路。(2)、导线架空敷设时其安全间距必须满足规范要求,当配电线路采用熔断器作短路保护时,熔体额定电流一定要小于电缆或穿管绝缘导线允许载流量的2.5倍,或明敷绝缘导线允许载流量的1.5倍。经常教育用电人员正确执行安全操作规程,避免作业不当造成火灾。(3)、电气操作人员要认真执行规范,正确连接导线,接线柱要压牢、压实。各种开关触头要压接牢固。铜铝连接时要有过渡端子,多股导线要用端子或涮锡后再与设备安装,以防加大电阻引起火灾。中国建筑第二工程局有限公司第11页 青岛游艇产业园区C-1-8地块临电施工方案(4)、配电室的耐火等级要大于三级,室内配置砂箱和绝缘灭火器。严格执行变压器的运行检修制度,按季度每年进行四次停电清扫和检查。现场中的电动机严禁超载使用,电机周围无易燃物,发现问题及时解决,保证设备正常运转。(5)、施工现场内严禁使用电炉子。使用碘钨灯时,灯与易燃物间距要大于30cm,室内不准使用功率超过100W的灯泡,严禁使用床头灯。(6)、使用焊机时要执行用火证制度,并有人监护,施焊周围不能存在易燃物体,并备齐防火设备。电焊机要放在通风良好的地方。(7)、施工现场的高大设备和有可能产生静电的电气设备要做好防雷接地和防静电接地,以免雷电及静电火花引起火灾。(8)、存放易燃气体、易燃物仓库内的照明装置一定要采用防爆型设备,导线敷设、灯具安装、导线与设备连接均应满足有关规范要求。(9)、配电箱、开关箱内严禁存放杂物及易燃物体,并派专人负责定期清扫。(10)、设有消防设施的施工现场,消防泵的电源要由总箱中引出专用回路供电,而且此回路不得设置漏电保护器,当电源发生接地故障时可以设单相接地报警装置。有条件的施工现场,此回路供电应由两个电源供电,供电线路应在末端可切换。(11)、施工现场应建立防火检查制度,强化电气防火领导体制,建立电气防火队伍。(12)、施工现场一旦发生电气火灾时,扑灭电气火灾应注意以下事项:(13)、迅速切断电源,以免事态扩大。切断电源时应戴绝缘手套,使用有绝缘柄的工具。当火场离开关较远需剪断电线时,火线和零线应分开错位剪断,以免在钳口处造成短路,并防止电源线掉在地上造成短路使人员触电。(14)、当电源线因其它原因不能及时切断时,一方面派人去供电端拉闸,另一方面灭火时,人体的各部位与带电体应保持一定充分距离,必须穿戴绝缘用品。(15)、扑灭电气火灾时要用绝缘性能好的灭火剂如干粉灭火机,二氧化碳灭火器或干燥砂子。严禁使用导电灭火剂进行扑救。1施工用电计算1.1施工机械配置(初版,根据正试图调整)桩基施工机械设备配置一览表机械或型号规格数量总功率用途中国建筑第二工程局有限公司第11页 青岛游艇产业园区C-1-8地块临电施工方案序号设备名称额定功率(KW)(KW)1冲孔桩机CZ-2060704200工程桩施工2排浆泵N8651575泥浆池3电焊机BX-3002524600钢筋加工4挖掘机PC2002/现场按需配置5装载机2/现场按需配置6汽车吊25T4/现场按需配置7履带吊50T6/现场按需配置8振动锤90T660360现场按需配置9钢筋弯曲机GW-40-1326钢筋弯曲10钢筋调直机GT4-1431854钢筋调直11钢筋切割机KS-D6533.510.5钢筋切割12镝灯42080现场照明13潜水泵扬程100m107.575抽排水14发电机500KW1紧急备用1.1总用电量计算P总=1.05~1.10[K机×(∑P机)/COSΦ+K焊×∑P焊+K照×∑P照]式中:P总—供电设备总需要容量(KVA)P机—电动机額定功率(KW)P焊—电焊机額定功率(KVA)P照—施工照明用电总功率(KW)COSΦ—功率因数K——需要系数其中:P机、P焊、P照详见施工现场主要机械设备表查表:K机=0.6,K焊=0.6,K照=1.0,COSΦ=0.75ΣP机=4420.5KW(振动锤考虑和桩机交错使用),ΣP焊=600KW,ΣP照=80KW。P总=1.05×(0.6×4420.5/0.75+600×0.6+80×1)=4175.22KVA本工程现场总提供用电容量为8x630=4800KVA,基本满足桩基施工使用。1.2配电导线截面计算(1)按照现场用电高峰最大负荷计算现场一级箱用电负荷(630A一级箱):中国建筑第二工程局有限公司第11页 青岛游艇产业园区C-1-8地块临电施工方案P=P总=4x70=280KwI=1000P/1.732×380×0.75=567.24A(控制机械时的电流)其中:∑P:各段线路负荷计算功率280kwI:线路工作电流值UI:UI=380vcosφ:用电设备功率因数,一般建筑工地取0.75。查表:导线采用YJV-4*240+1*120铜芯电缆(最大允许载电流630A)。(2)按照现场用电高峰最大负荷计算现场一级箱用电负荷(315A一级箱):P=P总=2x70=140KWI=1000P/1.732×380×0.75=283.62A(控制机械时的电流)其中:∑P:各段线路负荷计算功率140kwI:线路工作电流值UI:UI=380vcosφ:用电设备功率因数,一般建筑工地取0.75。查表:导线采用YJV-4*120+1*70铜芯电缆(最大允许载电流315A)。1附图:现场临电平面布置图(桩基)中国建筑第二工程局有限公司第11页'