- 838.00 KB
- 126页
- 1、本文档共5页,可阅读全部内容。
- 2、本文档内容版权归属内容提供方,所产生的收益全部归内容提供方所有。如果您对本文有版权争议,可选择认领,认领后既往收益都归您。
- 3、本文档由用户上传,本站不保证质量和数量令人满意,可能有诸多瑕疵,付费之前,请仔细先通过免费阅读内容等途径辨别内容交易风险。如存在严重挂羊头卖狗肉之情形,可联系本站下载客服投诉处理。
- 文档侵权举报电话:19940600175。
'摘要果汁废水主要来自冲洗水果、粉碎、榨汁等工序,罐装工段的洗瓶、灭菌、破瓶损耗和地面冲洗等环节。废水中含有较高浓度的糖类、果胶、果渣及水溶物和纤维素、果酸、单宁、矿物盐等。果汁废水中含有的糖类主要为果糖、葡萄糖、蔗糖,三者所占的比例为2:1:1.废水中含有大量的有机酸,不同的生产工艺阶段,所产生的废水具有不同的特点,即使在同一阶段,废水水质也因产品不同而差异较大本文介绍了有关UASB+SBR的处理流程和设计的计算、调节池、UASB池、SBR池、污泥浓缩池等进行了精细的设计和计算。并对主要构筑物UASB池、SBR池做了详细的说明。UASB+SBR处理高浓度有机废水,其关键是培养出沉降性能良好的厌氧颗粒污泥。采用此工艺,不但使处理流程简洁,也节省了运行费用,在降低废水浓度的同时,还可以回收在处理过程中所产沼气作为能源的利用。以便我为进一步探讨效益资源型处理技术提供借鉴。关键字:高浓度废水废水处理UASBSBR沼气回收81
Juicewastewatercomesfromtheprocessesofwashing,smashing,squeezingthefruitsandwashingbottles,sterilization,bottlebreakingloss,cleaningthegroundinthesectionoffillingupandsoon.Wastewatercontainshighconcentrationofsugars,pectin,marc,81
water-solublematerialandcellulose,acid,tannin,mineralsalts,etc.Themaincarbohydrateinjuicewastewaterarefructose,glucose,sucrose,theproportionofthethreeis2:1:1therearelotsoforganicacidsinwastewaterandthewaterwaterhastheircharacteristicsindifferentsectionofproducing.evenifinthesamesection,waterqualitywouldhavesignificantdifferencesbecauseofdifferentproducts.thisarticleintroducesthecourseanddesignplanningofusingUASB,collaboratingwithSBR.anditgivesadetaileddescriptionofthemainstructures,theUASBpoolandSBRpool.Usingthismethodtoprocessorganicwastewaterwithahighconcentration,thecriticalistobringupanaerobicgranularsludgewithgoodsettlementperformance.adoptingthismethod,notonlycanwemakethecoursemoresimple,butalsosavecosts.whileruducingtheconcentration,wecanrecyclethegastobeenergeinthecourse.soitcanofferreferencesformetomakefutherdisscussionontheeffectivenessofresource-basedprocessingtechnology81
第一章概述一.果汁废水特点1、果汁废水构成企业废水组成较为复杂,一般都有十多种废水需要处理,他们是:洗果排放水、设备清洗废水、消毒清洗废水、果汁冷凝水、设备冷却水、空调冷却水、设备外部清洗水、地面清洗水及其他排放废水。2、主要废水水质描述⑴81
、生产废水总排放池出口水质浓度,随企业的设备、工艺、管理的差异排水水质有较大波动。(2)、生产设备清洗废水:清洗废水周期性集中排水,对污水处理设施有较大冲击,一般需将清洗设备的高浓度酸碱水、消毒水等先做预处理(中和),然后再排入污水处理系统。⑶、超滤反冲产生的浓废水(锅底水):其中固形物占5-8%,每天排放约25-35t,COD浓度60000-80000mg/L,个别情况达到10万mg/L以上。需单独预处理后出水再可引入污水站系统,进行集中处理。⑷、消毒废水:设备清洗后需要消毒,消毒废水若直接排入污水处理系统,因其含有杀菌剂,将抑制生化过程的进行,导致微生物不能存活,所以这部分废水在直接排入生化系统前,需要在调节池中进行专门的处理,以保证系统正常运行。⑸、果汁冷凝水:该水为稀果汁浓缩单元产生的废水,水量较大,清澈透明,一般认为无污染,但分析证实该水COD为2000-2500mg/L,感官虽好,但污染较重。处理工艺只能用厌氧、好氧两级工艺。⑹、洗果排放水:该部分废水排放量及排放水质各企业差别较大,就目前各企业的排放情况来看,此部分废水悬浮物很大、含泥量很高,必须经过预处理方能保证后续水处理设施的正常运行。81
有机物浓度有机物浓度高,一般情况下COD>6000mg/L,BOD>4000mg/LSS(悬浮物)含有大量的果渣、果肉、果屑等物质,一般情况下SS>4000mg/L黏性含有果胶等胶体,废水黏性大水质、水量变化由于加工品种及产量经常变化,导致排放不均匀、水质水量变化大,COD变化值高时可达2000-3000mg/L,SS变化值可达1000-2000mg/L。PH果汁废水中含有大量果酸,因此PH较低,最低时可达4.0左右营养元素营养成分单一,C:N较高,缺乏氮、磷元素水温20-25摄氏度二.研究背景与意义水是生命之源,是人类赖以生存和发展的物质基础,是不可替代的宝贵资源。我国却是一个水资源十分短缺的国家,人均水资源占有量仅为世界平均水平的四分之一81
,严重制约着我国社会主义经济的发展。经济的腾飞是以环境的代价为前提的。随着近代我国社会主义经济的腾飞,社会主义工业呈现飞速发展,水资源污染尤其是工业废水污染也严重恶化。工业废水的污染以其污染大、污染物浓度高、废水排放量大、废水中含有多种有毒有害物质、废水成分复杂以及水量变化大等特点而成为目前我们所面临的主要问题。果汁废水主要来自冲洗水果、粉碎、榨汁等工序,罐装工段的洗瓶、灭菌、破瓶损耗和地面冲洗等环节。废水中含有较高浓度的糖类、果胶、果渣及水溶物和纤维素、果酸、单宁、矿物盐等果汁废水的水质和水量在不同季节有一定差别,处于高峰流量时的果汁废水,有机物含量也处于高峰。鉴于果汁废水自身的特性,果汁废水不能直接排入水体,因此果汁废水的处理是工业废水处理中重要的一个方面。三.本设计工程概况表1.1废水水质及排放标准项目CODCr(mg/L)BOD5(mg/L)SS(mg/L)pH原水12000800080005~12排放标准≤100≤30≤706~981
第二章工艺路线的确定及选择依据2.1处理方法比较果汁废水中大量的污染物是溶解性的糖类、果酸,这些物质具有良好的生物可降解性,处理方法主要是生物氧化法。有以下几种常用方法处理。(一)好氧处理工艺高浓度有机废水处理主要采用好氧处理工艺,主要由普通活性污泥法、生物滤池法、接触氧化法和SBR法。传统的活性污泥法由于产泥量大,脱氮除磷能力差,操作技术要求严,目前已被其他工艺代替。近年来,SBR和氧化沟工艺得到了很大程度的发展和应用。SBR工艺具有以下优点:运行方式灵活,脱氮除磷效果好,工艺简单,自动化程度高,节省费用,反应推动力大,能有效防止丝状菌的膨胀。81
CASS工艺(循环式活性污泥法)是对SBR方法的改进。该工艺简单,占地面积小,投资较低;有机物去除率高,出水水质好,具有脱氮除磷的功能,运行可靠,不易发生污泥膨胀,运行费用省。(二)水解—好氧处理工艺水解酸化可以使废水中的大分子难降解有机物转变成为小分子易降解的有机物,出水的可生化性能得到改善,这使得好氧处理单元的停留时间小于传统的工艺。与此同时,悬浮物质被水解为可溶性物质,使污泥得到处理。水解反应工艺式一种预处理工艺,其后面可以采用各种好氧工艺,如活性污泥法、接触氧化法、氧化沟和SBR等。废水经水解酸化后进行接触氧化处理,具有显著的节能效果,COD/BOD值增大,废水的可生化性增加,可充分发挥后续好氧生物处理的作用,提高生物处理废水的效率。因此,比完全好氧处理经济一些。(三)厌氧—好氧联合处理技术厌氧处理技术是一种有效去除有机污染物并使其碳化的技术,它将有机化合物转变为甲烷和二氧化碳。对处理中高浓度的废水,厌氧比好氧处理不仅运转费用低,而且可回收沼气;所需反应器体积更小;能耗低,约为好氧处理工艺的10%~15%;产泥量少,约为好氧处理的10%~15%;对营养物需求低;既可应用于小规模,也可应用大规模。厌氧法的缺点式不能去除氮、磷,出水往往不达标,因此常常需对厌氧处理后的废水进一步用好氧的方法进行处理,使出水达标。常用的厌氧反应器有UASB、AF、FASB等,UASB反应器与其他反应器相比有以下优点:81
①沉降性能良好,不设沉淀池,无需污泥回流②不填载体,构造简单节省造价③由于消化产气作用,污泥上浮造成一定的搅拌,因而不设搅拌设备④污泥浓度和有机负荷高,停留时间短同时,由于大幅度减少了进入好氧处理阶段的有机物量,因此降低了好氧处理阶段的曝气能耗和剩余污泥产量,从而使整个废水处理过程的费用大幅度减少。(四)不同处理系统的技术经济分析不同处理方法的技术、经济特点比较,见表1-1。表1-1不同处理方法的技术、经济特点比较处理方法主要技术、经济特点好氧工艺生物接触氧化法采用两级接触氧化工艺,可防止高糖含量废水引起污泥膨胀现象;但需要填料过大,不便于运输和装填,且污泥排放量大氧化沟工艺简单,运行管理方便,出水水质好,但污泥浓度高,污水停留时间长,基建投资大,曝气效率低,对环境温度要求高SBR法占地面积小,机械设备少,运行费用低,操作简单,自动化程度高;但还需曝气能耗,污泥产量大。81
厌氧好氧工艺水解—好氧技术节能效果显著,且BOD/COD值增大,废水的可生化性能增加,可缩短总水力停留时间,提高处理效率,剩余污泥量少UASB—好氧技术技术上先进可行,投资小,运行成本低,效果好,可回收能源,产出颗粒污泥产品,由一定收益;操作要求严从表中可以看出厌氧—好氧联合处理在啤酒废水处理方面有较大优点,故果汁废水厌氧—好氧处理技术是最好的选择。81
果汁废水先经过中格栅去除大杂质后进入集水池,用污水泵将废水提升至调节池,在调节池进行水质水量的调节。进入调节池前,根据在线PH计的PH值用计量泵将碱性水送入调节池,调节池的PH值在6.5~7.5之间。调节池中出来的水用泵连续送入混凝沉淀池,在混凝沉淀池中进行混凝,然后用水泵将水送入UASB反应器进行厌氧消化,降低有机物浓度。厌氧处理过程中产生的沼气被收集到沼气柜。UASB反应器内的污水流入SBR池中进行好氧处理,而后达标出水。来自,调节池,混凝沉淀池,UASB反应器、SBR反应池的剩余污泥先收集到集泥井,在由污泥提升泵提升到污泥浓缩池内被浓缩,浓缩后进入污泥脱水机房,进一步降低污泥的含水率,实现污泥的减量化。污泥脱水后形成泥饼,装车外运处置。第三章设计原则及设计规范一、设计原则1、执行国家环境保护的政策,符合国家和地方有关的法规、规范及标准,污水经处理后达标排放。2、根据企业规划和实际情况,力求做到系统布局合理,节省投资,又便于运行管理,充分发挥工程投资效益.3、采用高效、节能、先进、可靠的污水处理新工艺、新技术,实现污水处理站的低耗高效。4、在已建成相同类型处理站的基础上进行优化,尽可能降低投资和运行费用。81
6、操作管理方便,操作人员的劳动强度低。7、污水处理系统适合生产性变化。二、设计规范和标准1、《室外排水设计规范》GB50101-20052、《污水综合排放标准》GB8978-19963、《给水排水工程结构设计规范》GB500069-20024、国家现行的建设项目环境保护法规、条例;5、其他有关设计规范81
设计计算书一、预计处理效果表1.1废水水质及排放标准项目CODCr(mg/L)BOD5(mg/L)SS(mg/L)pH原水12000800080005~12排放标准≤100≤30≤706~9二、工艺流程图81
第一节格栅的设计计算一、设计说明格栅由一组平行的金属栅条或筛网制成,安装在废水渠道的进口处,用于截留较大的悬浮物或漂浮物,主要对水泵起保护作用,另外可减轻后续构筑物的处理负荷。二、设计参数取中格栅;栅条间隙d=10mm;栅前水深h=0.4m;过栅流速v=0.6m/s;安装倾角α=45°;设计流量Q=2500m3/d=0.029m3/s三、设计计算81
(一)栅条间隙数(n)式中:Q-------------设计流量,m3/sα-------------格栅倾角,度b-------------栅条间隙,mh-------------栅前水深,mv-------------过栅流速,m/sn=10.16取n=11条(二)栅槽有效宽度(B)设计采用φ20圆钢为栅条,即s=0.02mB=S(n-1)+en式中:S--------------格条宽度,mn--------------格栅间隙数b--------------栅条间隙,mB=0.02×(11-1)+0.01×11=0.31m(三)进水渠道渐宽部分长度(l1)81
设进水渠道内流速为0.5m/s,则进水渠道宽B1=0.175m,渐宽部分展开角取为20°则l1=式中:B--------------栅槽宽度,mB1--------------进水渠道宽度,m--------------进水渠展开角,度l1==0.27m(四)栅槽与出水渠道连接处的渐窄部分长度(l2)l2=l1/2=0.27/2=0.135m(五)过栅水头损失(h1)取k=3,β=1.79(栅条断面为圆形),v=0.6m/sh1=式中:k--------系数,水头损失增大倍数β--------系数,与断面形状有关S--------格条宽度,m81
d--------栅条净隙,mmv--------过栅流速,m/sα--------格栅倾角,度h1=0.176m(六)栅槽总高度(H)取栅前渠道超高h2=0.3m栅前槽高H1=h+h2=0.7m则总高度H=h+h1+h2=0.4+0.176+0.3=0.876m(七)栅槽总长度(L)L=l1+l2+0.5+1.0+=0.27+0.135+0.5+1.0+=2.605m(八)每日栅渣量(W)取W1=0.05m3/103m3K2=1.5则W=式中:Q-----------设计流量,m3/s81
W1----------栅渣量(m3/103m3污水),取0.1~0.01,粗格栅用小值,细格栅用大值,中格栅用中值W=0.08m3/d(可采用人工清渣)(九)集水池的设计计算在调节沉淀池之前和格栅之后设一集水池,其大小主要取决于提升水泵的能力,目的是防止水泵频繁启动。以延长水泵的使用寿命。设计参数水力停留时间HRT=1h,有效水深h1=4.0m,超高h2=0.5m;设计计算(1)集水池容积V=Q/T=(2500/24)×1=104.1m3(2)集水池的总高H=h1+h2=4.0+0.5=4.5m,(3)集水池的面积A=V/H=104.1/4.5=23.1m2取A=24m2集水池的横截面为:L×B=6×4(m²)则集水池的尺寸为:L×B×H=6×4×4.5(m3)(4)一次提升泵选取:提升流量Q=150m3/d,扬程10m81
第二节调节沉淀池的设计计算一、设计参数水力停留时间T=6h;设计流量Q=2500m3/d=104m3/h=0.029m3/s。表2.1调节沉淀池进出水水质指标水质指标CODBODSS进水水质(mg/l)1200080008000去除率(%)101010出水水质(mg/l)1080070007200二、设计计算(一)池子尺寸池子有效容积为:V=QT=104×6=624m3取池子总高度H=4.5m,其中超高0.5m,有效水深h=4m则池面积A=V/h=624/4=156m3池长取L=20m,池宽取B=8m则池子总尺寸为L×B×H=20×8×4.581
(二)理论上每日的污泥量W=式中:Q------------设计流量,m3/sC0------------进水悬浮物浓度,kg/m3C1------------出水悬浮物浓度,kg/m3P0------------污泥含水率,%W=66m3/d(三)污泥斗尺寸取斗底尺寸为400×400,污泥斗倾角取50°则污泥斗的高度为:h2=(4-0.2)×tg50°=4.529m(四)进水布置进水起端两侧设进水堰,堰长为池长2/3(五)PH调节在调节池中设置PH指示器,控制阀门的开启,调节强碱废水的排入,从而控制调节池中废水的PH.第三节沉淀池设计81
2.1设计参数(1)设计流量Q=3400m3/d=141.67m3/h=0.039m3/s(2)设计水质参数表8竖流式沉淀池进出水水质指标水质指标COD(㎎∕L)BOD(㎎∕L)SS(㎎∕L)进水水质1080070007200设计去除率102080%设计出水水质9720560014402.2设计计算设置两座沉淀池(1)中心管的面积(f)与直径(d0)取中心管流速v0=25mm/s则f=q/v0q--每个池子的设计流量(m3/s)f=0.029/2/0.025=0.58m2则d0=1.0m81
(2)中心管喇叭口与反射板之间的缝隙高度h3h3=q/(v13.14d1)q--每个池子的设计流量,m3/sv1--污水由中心管喇叭口与反射板之间的缝隙出流速度(m/s)d1--喇叭口直径(m)设v1=0.02m/sd1=1.35d0=1.35m则h3=0.029/2/(0.023.141.35)=0.17m(3)沉淀部分有效断面面积FF=q/vv--污水在沉淀池中的流速(m/s)设表面负荷q0=2.88m3/m2.h则v=q0/3600=0.0008m/sF=0.029/0.0008=36.25m2(4)沉淀池的直径DD=6.8m取D=7.0m(5)沉淀部分有效水深h2h2=vt3600t--沉淀时间(h)取t=1.2h则h2=0.00081.23600=3.46mD/h2<3符合要求(6)校核集水槽的出水堰负荷81
出水堰负荷:q/(D)=0.029/3.14/7=1.31L/s<2.9L/s符合要求(7)沉淀部分所需容积VV=c1—进水悬浮物的浓度(t/m3)c2—出水悬浮物的浓度(t/m3)—污泥容重,其值为1Kz—工业废水水量变化系数,本设计为1.3—污泥含水率,初沉池污泥一般为95%~97%,本设计采用95%T—排泥间隔时间(d)取T=1d所以V=123.4m3(8)圆截锥部分容积设圆锥下底的直径为0.4m,取锥角为55°则h5=(R-r)tan55°=4.7mV=63.9m3(9)沉淀池的总高H设超高h1和缓冲层高h4都为0.3m。H=h1+h2+h3+h4+h5=0.3+3.46+0.23+0.3+4.7=8.99m沉淀池排泥量计算:W=(Css0-Css1)*Q*50%=4000kg/d81
第四节UASB反应器的设计计算一、设计说明UASB,即上流式厌氧污泥床,集生物反应与沉淀于一体,是一种结构紧凑,效率高的厌氧反应器。它的污泥床内生物量多,容积负荷率高,废水在反应器内的水力停留时间较短,因此所需池容大大缩小。设备简单,运行方便,勿需设沉淀池和污泥回流装置,不需充填填料,也不需在反应区内设机械搅拌装置,造价相对较低,便于管理,且不存在堵塞问题。二、设计参数(一)参数选取设计参数选取如下:容积负荷(Nv)=10.2kgCOD/(m3·d);污泥产率0.1kgMLSS/kgCOD;产气率0.5m3/kgCOD(二)设计水质表2.2UASB反应器进出水水质指标81
水质指标CODBODSS进水水质(mg/l)972056001440去除率(%)909085出水水质(mg/l)972560200(三)设计水量 Q=2500m3/d=104m3/h=0.029m3/s三、设计计算(一)反应器容积计算UASB有效容积:V有效=式中:Q-------------设计流量,m3/sS0-------------进水COD含量,mg/lNv-------------容积负荷,kgCOD/(m3·d)V有效=2500m3将UASB设计成圆形池子,布水均匀,处理效果好取H=9m采用4座相同的UASB反应器 则 A1=69.4m2D=9.4m取D=10m81
则实际横截面积为=πD2=×3.14×102=78.5m2实际表面水力负荷为q1=0.6<1.0故符合设计要求(二)配水系统设计 本系统设计为圆形布水器,每个UASB反应器设36个布水点(1)参数 每个池子流量:Q=104/4=26m3/h(2)设计计算布水系统设计计算草图见下图2.3:81
圆环直径计算:每个孔口服务面积为:a==2.2m2a在1~3m2之间,符合设计要求可设3个圆环,最里面的圆环设6个孔口,中间设12个,最外围设18个孔口1)内圈6个孔口设计服务面积:=6×2.2=13.2m2折合为服务圆的直径为:=4.10m81
用此直径作一个虚圆,在该圆内等分虚圆面积处设一实圆环,其上布6个孔口,则圆的直径计算如下: 则d1==2.9m2)中圈12个孔口设计服务面积:S2=12×2.2=26.4m2折合成服务圆直径为: =7.1m中间圆环直径计算如下: π(5.672-d22)=S2则d2=3.92m3)外圈18个孔口设计 服务面积:S3=18×2.2=39.6m2折合成服务圈直径为:=10.04m外圆环的直径d3计算如下:π(8.012-d32)=S381
则d3=6.24m(三)三相分离器设计三相分离器设计计算草图见下图2.4:(1)设计说明三相分离器要具有气、液、固三相分离的功能。三相分离器的设计主要包括沉淀区、回流缝、气液分离器的设计。(2)沉淀区的设计81
三相分离器的沉淀区的设计同二次沉淀池的设计相同,主要是考虑沉淀区的面积和水深,面积根据废水量和表面负荷率决定。由于沉淀区的厌氧污泥及有机物还可以发生一定的生化反应产生少量气体,这对固液分离不利,故设计时应满足以下要求:1)沉淀区水力表面负荷<1.0m/h2)沉淀器斜壁角度设为50°,使污泥不致积聚,尽快落入反应区内。3)进入沉淀区前,沉淀槽底逢隙的流速≦2m/h4)总沉淀水深应大于1.5m5)水力停留时间介于1.5~2h如果以上条件均能满足,则可达到良好的分离效果沉淀器(集气罩)斜壁倾角θ=50°沉淀区面积为:A=1/4πD2=1/4×3.14×82=50.24m2表面水力负荷为:q=Q/A==0.51<1.0符合设计要求。(3)回流缝设计取h1=0.3m,h2=0.5m,h3=1.5m如图2.4所示:b1=h3/tgθ式中:b1----------下三角集气罩底水平宽度,m;81
θ----------下三角集气罩斜面的水平夹角;h3----------下三角集气罩的垂直高度,m;b1==1.26mb2=8-2×1.26=5.48m下三角集气罩之间的污泥回流逢中混合液的上升流速V1可用下式计算:V1=Q1/S1式中:Q1----------反应器中废水流量,m3/h;S1----------下三角形集气罩回流逢面积,m2;V1=0.9m/hV1<2m/s,符合设计要求上下三角形集气罩之间回流逢中流速(V2)可用下式计算:V2=Q1/S2,式中:Q1----------反应器中废水流量,m3/h;S2----------上三角形集气罩回流逢之间面积,m2;取回流逢宽CD=1.2m,上集气罩下底宽CF=6.0m则DH=CD×sin50°81
=0.92mDE=2DH+CF=2×0.92+6.0=7.84m=π(CF+DE)CD/2=26.07m2则V2=Q1/S2=0.8m/h净水的μ,故取μ=0.02g/cm·s由斯托克斯工式可得气体上升速度为:Vb===0.266cm/s=9.58m/hVa=V2=1.60m/h则:==5.9,==4.56>,故满足设计要求。(四)出水系统设计采用锯齿形出水槽,槽宽0.2m,槽高0.2m(五)排泥系统设计81
产泥量为:9720×0.9×0.1×2500×10-3=2100kgMLSS/d每日产泥量2430kgMLSS/d,则每个USAB日产泥量607.5kgMLSS/d,可用150mm排泥管,每天排泥一次。(六)产气量计算1.每日产气量:9720×0.90×0.5×2500×10-3=10000m3/d每个UASB反应器的产气量2沼气主管每池集气管通到一根主管,然后再汇入两池沼气主管。采用钢管,单池沼气主管管道坡度为0.5%.单池沼气主管内最大气流量取D=150㎜,充满度为0.8,则流速为3两池沼气最大气流量为取DN=250㎜,充满度为0.6;流速为2.水封灌设计水封灌主要是用来控制三相分离气的集气室中气液两相界面高度的,因为当液面太高或波动时,浮渣或浮沫可能会引起出气管的堵塞或使气体部分进入沉降室,同时兼有有排泥和排除冷凝水作用。81
①水封高度式中:H0————反应器至贮气罐的压头损失和贮气罐内的压头为保证安全取贮气罐内压头,集气罩中出气气压最大H1取2mH2O,贮气罐内压强H0为400㎜H2O。②水封灌水封高度取1.5m,水封灌面积一般为进气管面积的4倍,则水封灌直径取0.5m。3.沼气柜容积确定由上述计算可知该处理站日产沼气10000,则沼气柜容积应为3h产气量的体积确定,即。设计选用300钢板水槽内导轨湿式储气柜,尺寸为φ6000㎜×H10000㎜。第五节SBR反应器的设计计算一、设计说明81
经UASB处理后的废水,COD含量仍然很高,要达到排放标准,必须进一步处理,即采用好氧处理。SBR结构简单,运行控制灵活,本设计采用4个SBR反应池,每个池子的运行周期为6h二、设计参数(一)参数选取(1)污泥负荷率Ns取值为0.13kgBOD5/(kgMLSS·d)(2)污泥浓度和SVI污泥浓度采用4000mgMLSS/L,SVI取100(3)反应周期SBR周期采用T=6h,反应器一天内周期数n=24/6=4(4)周期内时间分配反应池数N=4进水时间:T/N=6/4=1.5h反应时间:3.0h静沉时间:1.0h排水时间:0.5h(5)周期进水量Q0==156.25m3/s(二)设计水量水质设计水量为:Q=2500m3/d=104m3/h=0.029m3/s81
设计水质见下表2.3:表2.3SBR反应器进出水水质指水质指标CODBODSS进水水质(mg/l)972560200去除率(%)919580出水水质(mg/l)882840三、设计计算(一)反应池有效容积V1=式中:n------------反应器一天内周期数Q0------------周期进水量,m3/sS0------------进水BOD含量,mg/lX-------------污泥浓度,mgMLSS/LNs-------------污泥负荷率V1=280.45m3(二)反应池最小水量Vmin=V1-Q0=280.45-156.25=124.2m381
(三)反应池中污泥体积Vx=SVI·MLSS·V1/106=100×4000×280.45/106=112.18m3Vmin>Vx,合格(四)校核周期进水量周期进水量应满足下式:Q0<(1-SVI·MLSS/106)·V=(1-100×4000/106)×280.45=176.46m3而Q0=156.25m3<176.46m3故符合设计要求(五)确定单座反应池的尺寸SBR有效水深取5.0m,超高0.5m,则SBR总高为5.5m,SBR的面积为280.45/5=56.09m2设SBR的长:宽=2:1则SBR的池宽为:5.5m;池长为:11.0m.SBR反应池的最低水位为:1.97mSBR反应池污泥高度为:1.24m1.97-1.24=0.73m可见,SBR最低水位与污泥位之间的距离为0.8m,大于0.5m的缓冲层高度符合设计要求。(六)鼓风曝气系统81
(1)确定需氧量O2由公式:O2=a′Q(S0-Se)+bˊXvV式中:aˊ-----------微生物对有机污染物氧化分解过程的需氧率,kgQ-----------污水设计流量,m3/dS0------------进水BOD含量,mg/lS0------------出水BOD含量,mg/lbˊ------------微生物通过内源代谢的自身氧化过程的需氧率,kgXv------------单位曝气池容积内的挥发性悬浮固体(MLVSS)量,kg/m3取aˊ=0.5,bˊ=0.15;出水Se=111mg/L;Xv=f×X=0.75×3000=2250mg/L=2.25kg/m3;V=4=4×298.08=1192.32m3代入数据可得:O2=0.5×2500×(700-28)/1000+0.15×2.25×1192.08=1242.3kgO2/d供氧速率为:R=O2/24=1242.3/24=51.8kgO2/h81
(2)供气量的计算采用SX-1型曝气器,曝气口安装在距池底0.3m高处,淹没深度为4.7m,计算温度取25℃。该曝气器的性能参数为:Ea=8%,Ep=2kgO2/kWh;服务面积1-3m2;供氧能力20-25m3/h·个;查表知氧在水中饱和容解度为:Cs(20)=9.17mg/L,Cs(25)=8.38mg/L扩散器出口处绝对压力为:=+9.8×103×H=1.013×105+9.8×103×4.7=1.47×105pa空气离开反应池时氧的百分比为:==19.65%反应池中容解氧的饱和度为:Csb(25)=Cs(25)=8.38=10.0mg/LCsb(20)=Cs(20)81
=9.17=10.9mg/L取α=0.85,β=0.95,C=2,ρ=1,20℃时,脱氧清水的充氧量为:R0===43.8kgO2/h供气量为:Gs=R0/0.3Ea==1826m3/h=30.43m3/min(3)布气系统的计算反应池的平面面积为:5.5×11.0×4=242m2每个扩散器的服务面积取1.4m2,则需242/1.4=170个。取170个扩散器,每个池子需50个。布气系统设计如下图2.5:81
(4)空气管路系统计算按SBR的平面图,布置空气管道,在相邻的两个SBR池的隔墙上设一根干管,共两根干管,在每根干管上设5对配气竖管,共10条配气竖管。则每根配气竖管的供气量为:本设计每个SBR池内有50个空气扩散器则每个空气扩散器的配气量为:选择一条从鼓风机房开始的最远最长管路作为计算管路,在空气流量变化处设计算节点。空气管道内的空气流速的选定为:81
干支管为10~15m/s;通向空气扩散器的竖管、小支管为4~5m/s;空气干管和支管以及配气竖管的管径,根据通过的空气量和相应的流速按《排水工程》下册附录2加以确定。空气管路的局部阻力损失,根据配件类型按下式式中:----------管道的当量长度,mD----------管径,mK----------长度换算系数,按管件类型不同确定折算成当量长度损失,并计算出管道的计算长度(m),空气管路的沿程阻力损失,根据空气管的管径D(mm),空气量m3/min,计算温度℃和曝气池水深,查《排水工程》下册附录三求得,得空气管道系统的总压力损失为:=96.21×9.8=0.943kpa空气扩散器的压力损失为5.0kpa,则总压力损失为:0.943+5.0=5.943kpa为安全起,设计取值为9.8kpa81
则空压机所需压力p=(5-0.3)×9.8×103+9.8×103=56kpa又Gs=37.64m3/min由此条件可选择罗茨RME-20型鼓风机转速1170r/min,配套电机功率为75kw(七)污泥产量计算选取a=0.6,b=0.075,则污泥产量为:△x=aQSr-bVXv=0.6×2500×(200-40)/1000-0.075×1192.08×2.25=38.84kgMLVSS/d第二章污泥部分各处理构筑物设计与计算第一节重力浓缩池的设计计算一、设计说明为方便污泥的后续处理机械脱水,减小机械脱水中污泥的混凝剂用量以及机械脱水设备的容量,需对污泥进行浓缩处理,以降低污泥的含水率。本设计采用间歇式重力浓缩池,运行时,应先排除浓缩池中的上清液,腾出池容,再投入待浓缩的污泥,为此应在浓缩池深度方向的不同高度上设上清液排除管。81
二、设计参数(一)设计泥量果汁废水处理过程产生的污泥来自以下几部分:(1)调节沉淀池,Q1=66m3/d,含水率97%;(2沉淀池,Q3==82m3/d含水率98%(3)UASB反应器,Q3=22m3/d,含水率98%;(4)SBR反应器,Q4=10m3/d,含水率99%;总污泥量为:Q=Q1+Q2+Q3+Q4=180m3/d平均含水率为:97.6%(二)参数选取固体负荷(固体通量)M一般为10~35kg/m3d取M=30kg/m3d=1.25kg/m3d;浓缩时间取T=24h;设计污泥量Q=180m3/d;浓缩后污泥含水率为96%;浓缩后污泥体积:108m3/d三、设计计算(一)池子边长根据要求,浓缩池的设计横断面面积应满足:A≧Qc/M81
式中:Q----------------入流污泥量,m3/d;M----------------固体通量,kg/m3·d;C----------------入流固体浓度kg/m3。入流固体浓度(C)的计算如下:=×1000×(1-97%)=1980kg/d=×1000×(1-98%)=1640kg/d=×1000×(1-98%)=400kg/d=×1000×(1-99%)=100kg/d那么,Qc=+++=4120kg/d=172kg/hC=4120/180=22.8kg/m3浓缩后污泥浓度为:=4120/108=38.1kg/m3浓缩池的横断面积为:A=Qc/M=137m2设计三座圆形浓缩池,则每座D=6.6m则实际面积A=140m2(二)池子高度停留时间,取HRT=24h81
则有效高度=1.3m,取=1.5m超高,取=0.5m缓冲区高,取=0.5m池壁高=++=2.5m(三)污泥斗污泥斗下锥体边长取1.0m,污泥斗倾角取50°则污泥斗的高度为:H4=(6.6/2–1.0/2)×tg50°=3.3m(四)总高度H=2.5+3.3=5.8m第二节集泥井一、设计说明污水处理系统各构筑物所产生的污泥每日排泥一次,集中到集泥井,然后在由污泥泵打到污泥浓缩池。污泥浓缩池为间歇运行,运行周期为24h,其中各构筑物排泥、污泥泵抽送污泥时间为1.0~1.5h,污泥浓缩时间为20.0h,浓缩池排水时间为2.0h,闲置时间为0.5h~1.0h。二、设计参数81
设计泥量总污泥量为:Q=180m3/d三、设计计算考虑各构筑物为间歇排泥,每日总排泥量为180m3/d,需在1.5h内抽送完毕,集泥井容积确定为污泥泵提升流量的10min的体积,即20m3。此外,为保证SBR排泥能按其运行方式进行,集泥井容积应外加37.23m3。则集泥井总容积为20+37.23=57m3。集泥井有效深度为3.0m,则其平面面积为设集泥井平面尺寸为5.0×5.0m。集泥井为地下式,池顶加盖,由污泥泵抽送污泥。集泥井最高泥位为-0.5m,最低泥位为-4m池底标高为-4.08m。浓缩池最高泥位为2.5m。则排泥泵抽升的所需净扬程为6.5m,排泥泵富余水头2.0m,管道水头损失为0.5m,则污泥泵所需扬程为6.5+2+0.5=9m。第三节机械脱水间的设计计算一、设计说明污泥经浓缩后,尚有96%的含水率,体积仍很大,为了综合利用和最终处置,需对污泥作脱水处理。81
拟采用带式压滤机使污泥脱水,它有如下脱水特点:(1)滤带能够回转,脱水效率高(2)噪声小,能源节省(3)附属设备少,维修方便,但必须正确使用有机高分子混凝剂,形成大而强度高的絮凝。污泥经浓缩后,尚有96%的含水率,体积仍很大,为了综合利用和最终处置,需对污泥作脱水处理。拟采用带式压滤机使污泥脱水二、设计参数设计泥量Q=180m3/d;含水率为96%。三、设计计算据设计泥量带式压滤机采用PFM-1000型,带宽1m,主机功率1.5kw,处理后的污泥含水率为75~80%,处理能力为7~8m3/h,按每天工作8小时设计。外形尺寸:长×宽×高=4500×1890×1860第四节污水提升泵房的设计与计算一、设计说明81
污水泵房用于提升污水厂的污水,以保证污水能在后续处理构筑物内畅通的流动,它由机器间、集水池、格栅、辅助间等组成,机器间内设置水泵机组和有关的附属设备,格栅和吸水管安装在集水池内,集水池还可以在一定程度上调节来水的不均匀性,以便水泵较均匀工作,格栅的作用是阻拦水中粗大的固体杂质,以防止杂物阻塞和损坏水泵,辅助间一般包括贮藏室,修理间,休息室和厕所等。二、设计计算(一)设计流量Q=2500m3/d=104m3/h=29.9l/s(二)选泵前总扬程估算经过格栅的水头损失为0.18m,进水管渠内水面标高为-2.335m则格栅后的水面标高为:-2.335-0.18=-2.515m设集水池的有效水深为2m则集水池的最低工作水位为:-2.515-2=-4.515m所需提升的最高水位为6.778m故集水池最低工作水位与所提升最高水位之间高差为:6.78-(-4.52)=11.30m出水管管线水头损失计算如下:出水管Q=34.7l/s,选用管径为200mm的铸铁管查《给水排水设计手册》第1册得:V=1.33m/s,1000i=19.1出水管线长度估为37m,局部系数为8则出水管管线水头损失为:81
==1.50m泵站内的管线水头损失假设为2.0m,考虑自由水头为1m,则水泵总扬程为:H=11.30+1.50+2.0+1.0=15.8m(三)选泵根据流量Q=104m3/h,扬程H=8m拟选用150WLI170-16.5型立式污水泵,每台水泵的流量为Q=170m3/h,扬程为H=16.5m。选择集水池与机器间合建的圆形水泵站,考虑选用2台水泵,其中一台备用。选用150WLI170-16.5型污水泵是合适的器间进行自然通风,在屋顶设置风帽。(5)起重设备选用电动葫芦。81
第三章高程布置(一)高程设计任务及原则其主要任务是:确定各处理构筑物和泵房的标高,确定处理构筑物之间连接管渠的尺寸及其标高,通过计算确定各部位的水面标高,从而能够使污水沿处理流程在处理构筑物之间通畅地流动,保证污水处理厂的正常运行。高程布置原则如下:(1)选择一条距离最长,水头损失最大的流程进行水力计算。并应适当留有余地,以保证在任何情况下,处理系统都能够运行正常。(2)计算水头损失时,一般应以近期最大流量作为构筑物和管渠的设计流量;计算涉及远期流量的管渠和设备时,应以远期最大流量为设计流量,并酌加扩建时的备用水头。(3)设置终点泵站的污水处理厂,水力计算常以接纳处理后污水水体的最高水位作为起点,逆污水处理流程向上倒退计算,以使处理后污水在洪水季节也能自流排出,而水泵需要的扬程则较小,运行费用也较低。但同时应考虑到构筑物的挖土深度不宜过大,以免土建投资过大和增加施工上的困难。还应考虑到因维修等原因需将池水放空而在高程上提出的要求。(481
)在作高程布置时还应注意污水流程与污逆流程的配合,尽量减少需抽升的污泥量。在决定污泥干化场,污泥浓缩池,消化池等构筑物的高程时,应注意它们的污泥水能自动排入污水入流干管或其它构筑物的可能。3.1污水高程计算污水高程计算表管道及构筑物名称Q管渠设计参数水头损失L/sDh/DivL沿程局部构筑物合计 mmm‰mmmmmm格栅29.10.280.28集水井至调节沉淀池29.13000.5510.3920.00190.00950.011429.1 0.50.581
调节沉淀池调节池至沉淀池14.53000.550.30.9150.00420.164 0.1682沉淀池29.10.50.5沉淀池至UASB7.2753000.550.10.9120.0010.20440.2054UASB7.2750.50.5UASB池至SBR7.2752500.50.20.8300.150.08490.2349SBR29.10.50.5SBR至出水口29.13000.550.31.02300.1710.1194 0.2904高程确定81
各构筑物间水位高程的确定,根据各构筑物及各构筑物之间的水头损失确定水位标高。构筑物水面标高(m)顶标高(m)低标高(m)有效水深m出水管000SBR4.795.29-0.215.0UASB5.525.82-3.188.7.沉淀池6.226.52-2.473.46调节池6.897.392.894.0集水间-0.500-4.504.0格栅-0.30-0.880.53.2污泥高程计算3.2.1污泥管道水头损失管道沿程损失管道局部损失式中:————污泥浓度系数————局部阻力系数D ————污泥管管径L————管道长度81
v————管内流速查表知污泥含水率98%时,污泥浓度系数=80,污泥含水率为96%时,污泥浓度系数=62。连接管道水头损失:污泥管道水头损失计算表管渠及构筑物名称流量(L/s)管渠设计参数水头损失(m)D(㎜)V(m/s)L(m)SBR—集泥井0.5172001.0360.170.20.37UASB—集泥井0.2842001.0650.250.310.56集泥井—浓缩池0.8012001.030.030.220.34池浓缩池—脱水机房0.4052001.040.030.20.233.2.2污泥处理构筑物的水头损失当污泥以重力流排出池体时,污泥处理构筑物的水头损失以各构筑物的出流水头计算,浓缩池一般取1.5m,SBR与UASB取0.5m。3.2.3污泥高程布置81
从SBR——集泥井推得,集泥井水位-0.21-0.37-0.5=-1.08m从UASB——集泥井推得,集泥井水位-3.18-0.56-0.5=-4.24m从集泥井——浓缩池推得,浓缩池水位-1.08-0.34-1.5=-2.92m集泥井液位确定为-1.08m,浓缩池液位确定为-2.92m,中间加污泥提升泵房提升污泥。集泥井设在污泥提升泵房下部。污泥提升泵的扬程为6m。表3-5污泥处理各构筑物标高构筑物名称水面标高池底标高集泥井-1.08-4.08浓缩池2.52-2.88第四章投资估算与效益分析1.构筑物与设备构筑物与设备一览表见表4.1表4.1构筑物与设备一览表序号名称规格数量设计参数主要设备1格栅L×2座81
B=2.605m×0.31m设计流量Q=2500m3/d,栅条间隙d=10㎜,栅前水深h=0.4m,过栅流速v=0.6m/s2集水池L×B×H=6m×4m×4.5m1座设计流量Q=2500m3/d,水力停留时间T=60s,有效水深h=4.0m,3调节池L×B×H=20m×8m×4.5m1座流量Q=104/h;时间T=2.0h;4泵房1座2台泵(1台备用),KWPF200-400型无堵塞离心泵2台5UASBD=10m4座设计流量Q=2500m3/d81
H=9m水力停留时间T=2.0h6SBRL×B×H=11m×5.5m×5.5m4座设计流量Q=2500/d反应时间t=3.0h周期T=6h7竖流式沉淀池D×H=7.0m×8.99m2座中心管流速0.03m/s表面负荷q1=2.52沉淀时间T=1.5h8污泥浓缩池D×H=6.6m×5.8m3座污泥量Q=180m3/d浓缩后含水率:p2=96%;浓缩后污泥体积:81
108m3/d;9集泥井L×B×H=5m×5m×3m1座10污泥提升泵房L×B=14m×5m1座污泥泵2台11脱水车间L×B=14m×5m1座进泥量为108m3/d贮泥时间为T=12hLW350×1550NY型带式压滤机,2台,15KW/台12鼓风机房L×B=14m×5m1座罗茨鼓风机4.2主要工程造价及运行费用表4.2 工程造价估算表81
分类序号名称价格(万元)备注土建部分 1集水井1.0108m32调节池5.0720m33UASB28.32826m34SBR14.11331m35竖流式沉淀池8.5691m36污泥浓缩池5.1595m37脱水车间4.3280m38鼓风机房4.0240m3设备部分 1格栅2.2台3Wm-180型网状膜型中微孔空气扩散器1.2*16十六台4罗茨鼓风机7*4四台9污泥泵4.0一台11LW350×1550NY型带式压滤机5.0*22台81
12加药系统1.5一套13管道、管件及材料2.0流量计、阀门、管道14电所控制、保温1.0 15化验仪器0.5 技术服务 1设计费10.0 2调试及培训4.50 3综合取费5.50 总计158万元(计吨水投资634元)表4.3运行分析表序号项目费用(元/m3)备 注81
人工费0.106人,1500元/(月.人)。2电 费0.612546.2kWh/d,1.2元/kWh。3药 费0.50加药0.1‰,5元/kg。合 计运行成本:1.21元/m34.3效益分析果汁废水处理厂效益包括经济效益、社会效益和环境效益。该废水厂进水经过以及处理后,悬浮物的去除率为96%,BOD5的去除率为93%左右,CODcr的去除率为90%左右。建设该污水厂的主要三大效益分析如下。5.3.1环境效益该水处理厂为城市污水处理站,对改善城市的环境有重要的作用,环境治理的好坏直接影响着一个城市的良性发展。该市中有50%的污水排入当地的主干河流,使得水体的有机污染物严重超标,各项指标均超出了《地面水环境标准》中Ⅲ类水体的水质标准。因此要保护该河流的水质,使其满足和达到渔业、生活饮用水质标准的良好状态,有利于生活饮用、工业和渔业用水,以及该河流的生态系统稳定性。该污水处理厂处理的污水是工业废水,其中大部分都是可生化的有机废水。经该污水处理厂处理后的污水可达到国家以及排放标准,这样在降低了当地的河流的水体污染的同时又满足了下游地区饮用水和景观用水的质量。81
5.3.2社会效益工程的实施对该市的河流段的水质有明显的改善,同时也对该市的社会生产产生巨大的影响。水质的改善将促进该市的旅游业的发展,有利于该市在经济全方位的发展,在国内及国际的声誉将会进一步提高。同时也会给下游地区带来巨大的经济效益,保障当地及下游地区人民的身体健康,保障当地的与其他地区的经济的和谐可持续发展。5.3.3经济效益污水处理厂作为一项环境治理项目,其本身并不产生直接的经济效益。该污水厂建成后将提高该市以及主干河流的环境质量,减轻污水排放所造成的污染危害。保护该市的饮用水源,降低自来水的处理成本,保护市民的健康。而产生的间接经济效益目前尚无法定量,定性的讲,其产生的间接经济效益是巨大的。同时该工程的实施有利于当地的渔业发展,在提高饮用水水质的同时有利于当地人民的健康。文献翻译环境风险评价是当前环境保护工作中一个新兴领域,它的诞生一方面是环境保护的迫切需要,另一方面也是环境科学发展的必然结果。标志着环境保护的一次重要战略转折,由原先污染后的治理转变为污染前的预测和实行有效管理。因此愈来愈受到许多国家环保机构和有关国际性组织的重视。81
风险评价兴起于七十年代几个工业发达国家,尤以美国在这方面的研究独领风骚。在短短20多年中,就环境风险评价技术而言,大体上经历了三个时期:七十年代至八十年代初,风险评价处于萌芽阶段,风险评价内涵不甚明确,仅仅采取毒性鉴定的方法;八十年代中,风险评价得到很大的发展,为风险评价体系建立的技术准备阶段。美国国家科学院(NAS,1983)[1]提出风险评价由四个部分组成,称为风险评价“四步法”即危害鉴别,剂量一效应关系评价,暴露评价和风险表征。并对各部分都作了明确的定义。由此,风险评价的基本框架已经形成。在此基础上,美国EPA制定和颁布了有关风险评价的一系列技术性文件、准则或指南。但大多是人体健康风险评价方面的。例如,1986年发布了致癌风险评价、[2]致畸风险评价、[3]化学混合物健康风险评价、[4]发育毒物健康风险评价、[5]暴露评价、[6]超级基金场地(Superfundsites)危害评价和风险评价[7]等指南。1988年又发布了内吸毒物(sytemictoxicants)[8]和男女繁殖性能毒物[9,10]等评价指南。1989年,美国EPA还对1986年指南进行了修改。因此,从1989年起,风险评价的科学体系基本形成,并处于不断发展和完善的阶段。81
由此可见,原先的风险评价主要限于人体健康风险评价,许多有害废物管理也是着眼于人体健康风险进行的。近几年来,生态风险评价业已被人们所重视,已处在同人体健康风险评价的同等地位。但是到目前为止,生态风险评价还没有一套方法指南。尽管有人将NAS模式加以改变后用于讨论生态风险问题,生态风险评价原则上也可按其四个方面进行,但由于生态风险评价不完全等同于人体健康风险评价,用于人体健康风险评价的一系列方法指南并不完全适用于生态风险评价。因此美国EPA从1989年以来一直致力于生态风险评价指南的制订工作,1992年确定了一个生态风险评价指南制订工作大纲[11],原则上给出了生态风险评价的框架。从研究内容上看,大致上与NAS提出的“四步法”相同,但每一方面的重点和方法又有不同的内容。该大纲将生态风险评价过程分为三步:第一步为问题阐述(Problemformulation),描述目标污染物特性和有风险生态系统,进行终点选择和有关评价中假设的提出。问题阐述是确定评价范围和制定计划的过程;第二步为分析阶段(analysisphase),主要从暴露表征和生态效应表征两个方面进行;第三步为风险表征。81
显然,目前国外环境风险评价主要包括人体健康风险评价和生态风险评价两方面,风险评价的科学体系已基本形成。相对来说,人体健康风险评价的方法基本定型,生态风险评价正处在总结、完善阶段。总的来说,目前国外环境风险评价具有如下的特点和趋势:·研究热点已由人体健康风险评价转移到生态风险评价;·从污染物数量来说,已由单一污染物作用进一步考虑到多种污染物的复合作用;·从环境风险类型来说,不仅考虑化学污染物,特别是有毒有害化学物,而且还要考虑到非化学因子对环境的不利影响;·从评价范围方面来说,由局部环境风险发展到区域性环境风险,乃至全球环境风险;·生态风险不仅仅只考虑到生物个体和群体,而且考虑到群落、甚至整个生态系统;·技术处理上由定性向半定量、定量方向发展。环境风险评价技术,特别是生态风险评价,还有许多问题有待研究,其中主要的有以下几方面:81
1.评价终点的选择人体健康风险评价的终点,只有一个物种(受体为人),而生态风险评价的终点却不止一个,终点选择就成了生态风险评价过程的关键。对任何不同组织等级都有终点选择问题,终点选择原则上根据所关注的生态系统和污染物特性来进行,对生态系统和污染物特性了解得愈深刻,终点选择就愈准确。由于生态系统复杂性,不同评价人员可以选择不同的终点,因此目前迫切需要有一个统一的方法来确定生态风险评价的终点。2.模型优化模型在风险评价中的重要性是显而易见的,因为风险评价是研究人为活动引起环境不利影响的可能性,是根据有限的已知资料预测未知后果的过程,这就需要应用大量的数学模型才能完成。模型的优劣直接关系到整个风险评价结果的准确性。风险评价涉及的模型很多,主要有污染物环境转归模型、污染物时空分布模型、暴露模型、生物体分布模型、外推模型、风险计算模型等。风险评价就是由这些模型的组合,借助于计算机来连串在一体的。随着风险评价越来越复杂,准确性要求越来越高,发展和完善各种数学模型始终是风险评价研究的重要方面。3.生态暴露评价81
在人体健康风险评价中,暴露评价是测定人体暴露值大小、频率、途径和暴露时间,表征受暴露的人群。在生态风险评价中、暴露评价相对人体健康暴露评价来说是特别困难的,尤其对暴露群体的表征,针对不同物种,它们栖息地环境差异很大,如水生环境、陆生环境和其他特定环境等。目前对生态暴露评价的定义还没有完全统一,一般认为生态暴露评价是测定污染物的空间和时间分布、存在形态、生物有效性以及与所关注的生态组分的接触状况。生态暴露评价是生态风险评价过程中最基本的组成部分,由于暴露系统的复杂性,目前还没有一个暴露的描述能适用所有的生态风险评价。由于对存在风险的种群认识不完全、污染物有效性的因子了解不够、单一、特别是多种混合物暴露的剂量一响应规律认识不深入,以及将实验室结果外推到野外的不同时空范围的困难等,暴露评价中的许多因子都存在不确定性。显然,生态暴露评价远比人体暴露评价复杂,关键必须考虑污染物与生物体以及生态系统、污染物与环境间的相互作用、相互影响。因此,必须加强这方面评价方法和技术的研究。4.不确定性处理不确定性处理一直是风险评价中的主要问题。不确定性来源于各种外推过程,例如:物种间外推、不同等级生物组织间外推、由实验室向野外情况外推,由高剂量向低剂量外推等。因此对不确定性的定量化处理是风险评价必须解决的关键技术问题。要发展各种外推理论,建立合适的外推模型。81
总之,随着环境保护进入一个新的时代,可以预见,环境风险评价研究必将对人类生存及自然环境的保护和改善作出新的贡献,并将对环境科学理论研究有新的推进。Environmentalriskassessmentisanemergingenvironmentalprotectionworkinthefield;ontheotherhand,itisthebirthoftheurgentneedforenvironmentalprotection,environmentalscience,andtheinevitableresultofthedevelopment.Itisatransitionwhichmarksanimportantenvironmentalprotectionstrategy,sothatfromthemanagementofpollutiontothepre-pollutionforecastandtheimplementationofeffectivemanagement.Manycountries’environmentalprotectionagenciesandrelevantinternationalorganizationsstarttofocusonthisproblem.Theriskassessmentemergedinseveralindustrializedcountriesin1970’s;particularlytheUnitedStatesistheleadingresearchinthisarea.Inashortspanof20years,generally,theenvironmentalriskassessmenttechnologyhasgonethroughthreeperiods:in1970’sto1980’s,riskassessmentwasinfancy,81
theconnotationofriskassessmentisun-clear,justusingthetoxicityidentifiedmethod;in1980’s,theriskassessmenthasbeendevelopmentalot,itwasthetechnicalpreparationphaseoftheriskassessmentsystem.UnitedStatesNationalAcademyofSciences(NAS,1983)[1]proposedriskassessmentconsistsoffourparts,knownastheRiskAssessmentofthe"fourstep"thatis,againsttheidentification,evaluationofdose-effectrelationship,exposureassessmentandriskcharacterization.Italsonamedproperlydefinitionforallparts.Thus,thebasicframeworkofriskassessmenthasbeenformed.Basedonthis,theU.S.EPAformulaandpromulgatetheseriesoftechnicalpapers,guidelines,orguidelinesofriskassessment.However,mostruleswerehumanhealthriskevaluation.Forexample,in1986,issuedacarcinogenicriskassessment,[2]teratogenicriskassessment,[3]thechemicalmixturehealthriskassessment,[4]Developmentoftoxichealthriskassessment,[5]exposureassessment,[6]Superfundsite(Superfundsites)hazardevaluationandrisk81
assessment[7]andotherguidelines.Alsoin1988,itreleasedwiththeobjectdrug(sytemictoxicants)[8]andtheperformanceofmaleandfemalereproductivetoxicology[9,10]andotherevaluationguide.In1989,theU.S.EPAwasrevisedtheguidancefrom1986.Therefore,since1989,riskassessmentofthescientificsystemhasbasicallyshaping,andconstantdevelopmentandimprovementphase.Itcanbeseenthattheoriginalriskassessmentismainlylimitedtohumanhealthriskassessment;hazardouswastemanagementisalsofocusonthehumanhealthrisks.Inrecentyears,theecologicalriskassessmenthasbeenattention,andbecomesthesamestatuswiththehumanhealthriskassessment.Sofar,ecologicalriskassessmentmethodologydoesnothaveaguide,althoughsomepeoplewillchangeNASmodelsfordiscussionthequestionofecologicalrisk,ecologicalriskassessmentmayalsofollowsthefouraspects,neverthelessecologicalriskassessmentisnotexactlythesameashumanhealthriskassessment,theguide81
forhumanhealthriskassessmentarenotentirelyapplicabletoecologicalriskassessment.Since1989,U.S.EPAhasbeenworkingonthesyllabusofecologicalriskassessmentguidelines;in1992,thesyllabusofecologicalriskassessmentguidelineshasbeencomingup[11],inprinciple,giventheframeworkofecologicalriskassessment.Fromtheresearchpointofview,itissameastheNAS"s"four-step",buteverythefocusandmethodsofaspectshavedifferentcontent.Theoutlineprocesstheecologicalriskassessmentintothreesteps:thefirststepofaproblem(Problemformulation),todescribecharacteristicsofthetargetpollutantsandtheriskoftheecologicalsystemfortheendoftheselectionandevaluationoftheassumptionsmade.Theproblemistheprocesstodeterminethescopeoftheevaluationandplanning;thesecondstepfortheanalysisphase(analysisphase),mainlyfromtheexposureandecologicaleffectscharacterizationoftwoaspects;thethirdstepisriskcharacterization.81
Admittedly,environmentalriskassessmentincludeshumanhealthandecologicalriskassessmentinabroad,andriskassessmentofthescientificsystemhasbeenbasicallyformed.Relativelyspeaking,themethodsofhumanhealthriskassessmenthavebeenshape;ecologicalriskassessmentisconcludingandbecomessatisfactory.Ingeneral,thecurrentenvironmentalriskassessmentfollowsseveralcharacteristicsandtrendsinabroad:Researchfocusfromhumanhealthriskassessmenttransferredtotheecologicalriskassessment;Fromtheamountofpollutants,fromthinkingtheroleofasinglepollutanttakingintoaccountthecomplexroleofavarietyofpollutants;Environmentalriskfromthetypeofexample,notonlytakeintoaccountchemicalpollutants,especiallytoxicandhazardouschemicals,butalsonon-chemicalfactorstakeintoaccounttheadverseeffectsonthe81
environment;Fromthescopeoftheevaluation,fromlocalenvironmentalrisksdevelopmenttoregionalenvironmentalrisks,aswellasglobalenvironmentalrisks;Ecologicalrisk,notonlytakingintoaccountsbiologicalindividualsandgroups,butalsotakingintoaccountthecommunity,evenstheentireecosystem;Processingtechnicalisfromsemi-quantitativetoquantitativedirection.Environmentalriskassessmenttechniques,especiallytheecologicalriskassessmentstillhavemanyissuescanbeexamined,suchas:1.EvaluationtheendchoiceTheonlyendishuman(humanreceptor)forhumanhealthriskassessment,andecologicalriskassessmentismorethanoneend,thechoiceofendisthekeyof81
ecologicalriskassessmentprocess.Thechoiceofdestinationistheproblemfordifferentlevelsanyorganization,theendofselectionbasedontheprincipleofecosystemcharacteristicsandpollutants,andthemoredeepunderstandingaboutpollutantsandecosystemcharacteristics,themoreaccuratetheendofchoicewillbe.Duetothecomplexityofecologicalsystems,differentevaluatorscanchoosedifferentendpoints,sothereisanurgentneedthataunifiedprescribesecologicalriskassessmenttodeterminetheend.2.ModeloptimizationItisobvioustoseetheimportantofmodelofriskassessment,becausetheriskassessmentistostudytheenvironmentcausedbyhumanactivitiesadverselyaffectthepossibilityisbasedonlimitedinformationtopredicttheunknownconsequencesofknownprocess,whichrequirestheapplicationofalargenumberofmathematicalmodelstocomplete.Theaccurateresultsdependonthequalityofmodelofriskassessment.Riskassessmentmodelinvolvedalotof81
things,suchaspollutantsintheenvironmenttransferredtothemodel,modelofspatialandtemporaldistributionofpollutants,exposuretomodeldistributionmodelorganisms,theextrapolationmodel,theriskcalculationmodelandsoon.RiskAssessmentisacombinationbythesemodels,throughtheuseofcomputerstostringasaseriesinone.Withmorecomplexriskassessment,theaccuracyneedtobeincreasinglyhigh,itisimportanttodevelopandimprovethemathematicalmodelforavarietyofriskassessmentaspectofthestudy.3.EcologicalexposureassessmentExposureassessmentisthedeterminationofhumanexposuretothevalueofthesize,frequency,channels,andexposuretimeinhumanhealthriskassessment,characterizedbytheexposedpopulation.Intheecologicalriskassessment,exposureassessmentisrelativeharderthanhumanhealthexposureassessment,especiallyforthecharacterizationofexposuregroups,fordifferentspecies,theirhabitatverydifferent81
environment,suchasenvironment,terrestrialenvironmentandotherspecificenvironmentalandsoon.Atpresent,thedefinitionofecologicalexposureevaluationhasnotbeenfullyunified;generallyexposureassessmentisthedeterminationofecologicalpollutantsdistributionofspaceandtime,theexistenceofmorphological,bio-effectivenessandecologicalcomponentsofconcerntothecontactsituation.Ecologicalexposureassessmentisthemostbasiccomponentofthesystemoftheprocessofecologicalriskassessmentasaresultofexposuretothecomplexnatureofexposureisnotadescriptioncouldapplytoalloftheecologicalriskassessment.Exposureassessmentofmanyfactorsthereareuncertainties.Thereasonsarethatthereisariskthattheincompleteunderstandingofthepopulation,theeffectivenessfactorofpollutantsnotunderstandasingle,especiallythemulti-doseexposuretoamixtureofresponsedonothaveaprofoundunderstandingofthelaw,aswellaslaboratoryresultstothefieldofthedifferentspatialand81
temporalscalesdifficultiesandsoon.Itisclearthatecologicalexposureassessmentiscomplexthanhumanexposureassessment,thekeypointsarepollutantsandorganismsmustbeconsidered,aswellasecosystems,pollutionandenvironmentinteraction,mutualinfluence.Therefore,wemuststrengthentheevaluationofresearchmethodsandtechniques.4.DealofuncertaintyItisalwaysthemajorproblemthatDealwithuncertaintyinriskassessment.Uncertaintiesinextrapolatingfromthevarietyprocesses,suchas:inter-speciesextrapolation,betweendifferentlevelsofbiologicalorganizationextrapolationfromlaboratorytofieldextrapolationcases,fromhigh-dosetolow-doseextrapolationandothers.Therefore,itisthekeytechnicalproblemstoaddressthattheuncertaintydealingwithquantitativeriskassessment.Weneedtodevelopextrapolationtheory,andbuiltuptheappropriateextrapolationmodel.Inshort,withtheEnvironmentalProtectionhasenteredanewera,itcan81
bepredictedthatenvironmentalriskassessmentstudieswillwritefreshhistoryaboutthesurvivalofmankind,environmentprotectandimprovethenaturalenvironmenttomakenewcontributionstothetheoreticaladvancingofenvironmentalsciencestudy.81
原文已完。下文为附加文档,如不需要,下载后可以编辑删除,谢谢!施工组织设计本施工组织设计是本着“一流的质量、一流的工期、科学管理”来进行编制的。编制时,我公司技术发展部、质检科以及项目部经过精心研究、合理组织、充分利用先进工艺,特制定本施工组织设计。一、工程概况:西夏建材城生活区27#、30#住宅楼位于银川市新市区,橡胶厂对面。本工程由宁夏燕宝房地产开发有限公司开发,银川市规划建筑设计院设计。本工程耐火等级二级,屋面防水等级三级,地震防烈度为8度,设计使用年限50年。本工程建筑面积:27#楼3824.75m2;30#楼3824.75m2。室内地坪±0.00以绝对标高1110.5m为准,总长27#楼47.28m;30#楼47.28m。总宽27#楼14.26m;30#楼14.26m。设计室外地坪至檐口高度18.600m,呈长方形布置,东西向,三个单元。本工程设计屋面为坡屋面防水采用防水涂料。外墙水泥砂浆抹面,外刷浅灰色墙漆。内墙面除卫生间200×45
300瓷砖,高到顶外,其余均水泥砂桨罩面,刮二遍腻子;楼梯间内墙采用50厚胶粉聚苯颗粒保温。地面除卫生间200×200防滑地砖,楼梯间50厚细石砼1:1水泥砂浆压光外,其余均采用50厚豆石砼毛地面。楼梯间单元门采用楼宇对讲门,卧室门、卫生间门采用木门,进户门采用保温防盗门。本工程窗均采用塑钢单框双玻窗,开启窗均加纱扇。本工程设计为节能型住宅,外墙均贴保温板。本工程设计为砖混结构,共六层。基础采用C30钢筋砼条形基础,上砌MU30毛石基础,砂浆采用M10水泥砂浆。一、二、三、四层墙体采用M10混合砂浆砌筑MU15多孔砖;五层以上采用M7.5混合砂浆砌筑MU15多孔砖。本工程结构中使用主要材料:钢材:I级钢,II级钢;砼:基础垫层C10,基础底板、地圈梁、基础构造柱均采用C30,其余均C20。本工程设计给水管采用PPR塑料管,热熔连接;排水管采用UPVC硬聚氯乙烯管,粘接;给水管道安装除立管及安装IC卡水表的管段明设计外,其余均暗设。本工程设计采暖为钢制高频焊翅片管散热器。本工程设计照明电源采用BV-2.5铜芯线,插座电源等采用BV-4铜芯线;除客厅为吸顶灯外,其余均采用座灯。一、施工部署及进度计划1、工期安排45
本工程合同计划开工日期:2004年8月21日,竣工日期:2005年7月10日,合同工期315天。计划2004年9月15日前完成基础工程,2004年12月30日完成主体结构工程,2005年6月20日完成装修工种,安装工程穿插进行,于2005年7月1日前完成。具体进度计划详见附图-1(施工进度计划)。2、施工顺序⑴基础工程工程定位线(验线)→挖坑→钎探(验坑)→砂砾垫层的施工→基础砼垫层→刷环保沥青→基础放线(预检)→砼条形基础→刷环保沥青→毛石基础的砌筑→构造柱砼→地圈梁→地沟→回填工。⑵结构工程结构定位放线(预检)→构造柱钢筋绑扎、定位(隐检)→砖墙砌筑(+50cm线找平、预检)→柱梁、顶板支模(预检)→梁板钢筋绑扎(隐检、开盘申请)→砼浇筑→下一层结构定位放线→重复上述施工工序直至顶。⑶内装修工程门窗框安装→室内墙面抹灰→楼地面→门窗安装、油漆→五金安装、内部清理→通水通电、竣工。⑷外装修工程外装修工程遵循先上后下原则,屋面工程(包括烟道、透气孔、压顶、找平层)结束后,进行大面积装饰,塑钢门窗在装修中逐步插入。一、施工准备45
1、现场道路本工程北靠北京西路,南临规划道路,交通较为方便。场内道路采用级配砂石铺垫,压路机压。2、机械准备⑴设2台搅拌机,2台水泵。⑵现场设钢筋切断机1台,调直机1台,电焊机2台,1台对焊机。⑶现场设木工锯,木工刨各1台。⑷回填期间设打夯机2台。⑸现场设塔吊2台。3、施工用电施工用电已由建设单位引入现场;根据工程特点,设总配电箱1个,塔吊、搅抖站、搅拌机、切断机、调直机、对焊机、木工棚、楼层用电、生活区各配置配电箱1个;电源均采用三相五线制;各分支均采用钢管埋地;各种机械均设置接零、接地保护。具体配电箱位置详见总施工平面图。3、施工用水施工用水采用深井水自来水,并砌筑一蓄水池进行蓄水。楼层用水采用钢管焊接给水管,每层留一出水口;给水管不置蓄水池内,由潜水泵进行送水。4、生活用水生活用水采用自来水。45
1、劳动力安排⑴结构期间:瓦工40人;钢筋工15人;木工15人;放线工2人;材料1人;机工4人;电工2人;水暖工2人;架子工8人;电焊工2人;壮工20人。⑵装修期间抹灰工60人;木工4人;油工8人;电工6人;水暖工10人。四、主要施工方法1、施工测量放线⑴施工测量基本要求A、西夏建材城生活区17#、30#住宅楼定位依据:西夏建材城生活区工程总体规划图,北京路、规划道路永久性定位B、根据工程特点及<建筑工程施工测量规程>DBI01-21-95,4、3、2条,此工程设置精度等级为二级,测角中误差±12,边长相对误差1/15000。C、根据施工组织设计中进度控制测量工作进度,明确对工程服务,对工程进度负责的工作目的。⑵工程定位A、根据工程特点,平面布置和定位原则,设置一横一纵两条主控线即27#楼:(A)轴线和(1)轴线;30#楼:(A)轴线和(1)轴线。根据主轴线设置两条次轴线即27#45
楼:(H)轴线和(27)轴线;30#楼:(H)轴线和(27)轴线。B、主、次控轴线定位时均布置引桩,引桩采用木桩,后砌一水泥砂浆砖墩;并将轴线标注在四周永久性建筑物或构造物上,施测完成后报建设单位、监理单位确认后另以妥善保护。C、控轴线沿结构逐层弹在墙上,用以控制楼层定位。D、水准点:建设单位给定准点,建筑物±0.00相当于绝对标高1110.500m。⑶基础测量A、在开挖前,基坑根据平面布置,轴线控制桩为基准定出基坑长、宽度,作为拉小线的依据;根据结构要求,条基外侧1100mm为砂砾垫层边,考虑放坡,撒上白灰线,进行开挖。B、在垫层上进行基础定位放线前,以建筑物平面控制线为准,校测建筑物轴线控制桩无误后,再用经纬仪以正倒镜挑直法直接投测各轴线。C、标高由水准点引测至坑底。⑷结构施工测量A、首层放线验收后,主控轴一引至外墙立面上,作为以上务层主轴线竖身高以测的基准。B、施工层放线时,应在结构平面上校投测轴线,闭合后再测设细部尺寸和边线。45
C、标高竖向传递设置3个标高点,以其平均点引测水平线折平时,尽量将水准仪安置在测点范围内中心位置,进行测设。2、基坑开挖本工种设计地基换工,夯填砂砾垫层1100mm;根据此特点,采用机械大开挖,留200mm厚进行挖工、铲平。开挖时,根据现场实际土质,按规范要求1:0.33放坡,反铲挖掘机挖土。开挖出的土,根据现场实际情况,尽量留足需用的好土,多余土方挖出,避免二次搬运。人工开挖时,由技术员抄平好水平控制小木桩,用方铲铲平。挖掘机挖土应该从上而下施工,禁止采用挖空底脚的操作方法。机械挖土,先发出信号,挖土的时候,挖掘机操作范围内,不许进行其他工作,装土的时候,任何人都不能停留在装土车上。3、砌筑工程⑴材料砖:MU15多孔砖,毛石基础采用MU30毛石。砂浆:±0.00以下采用M10水泥砂浆,一、二、三、四层采用M10混合砂浆,五层以上采用M7.5混合砂浆。⑵砌筑要求A、开工前由工长对所管辖班组下发技术交底。B、砌筑前应提前浇水湿润砖块,水率保持在10%-15%。C、砌筑采用满铺满挤“三一砌筑法“45
,要求灰浆饱满,灰缝8-12mm。D、外墙转角处应同时砌筑,内外墙交接处必须留斜槎,槎子长度不小于墙体高度的2/3,槎子必须平直、通顺。E、隔墙与墙不同时砌筑又不留成斜槎时可于墙中引出阳槎或在墙的灰缝中预埋拉结筋,每道不少于2根。F、接槎时必须将表面清理干净,浇水湿润,填实砂浆,保持灰缝平直。G、砖墙按图纸要求每50mm设置2φ6钢筋与构造柱拉结,具体要求见结构总说明。H、施工时需留置临时洞口,其侧边离交接处的墙面不少于500mm,顶部设边梁。4、钢筋工程⑴凡进场钢筋须具备材质证明,原材料须取样试验,经复试合格后方可使用。⑵钢筋绑扎前应仔细对照图纸进行翻样,根据翻样配料,施工前由工长对所管辖班组下发技术交底,准备施工工具,做好施工的准备工作。⑶板中受力钢筋搭接,I级钢30d,II级钢40d,搭接位置:上部钢筋在跨中1/3范围内,下部钢筋在支座1/3范围内。⑷钢筋保护层:基础40mm,柱、梁30mm,板20mm。保护层采用50mm×50mm的水泥砂浆块。板上部钢筋用马凳按梅花状支起。45
⑸所有钢筋绑扎,须填写隐检记录,质评资料及目检记录,验收合格后方可进行下道工序。5、砼工程⑴水泥进场后须做复试,经复试合格后由试验室下达配合比。施工中严格掌握各种材料的用量,并在搅拌机前进行标识,注明每立方米、每盘用量。同时搅拌时,须车车进磅,做好记录。⑵浇筑前,对模板内杂物及油污、泥土清理干净。⑶投料顺序:石子→水泥→砂子。⑷本工程均采用插入式振捣器,一次浇筑厚度不宜超过振捣器作用部分长度的1.25倍,捣实砼的移动间距不宜大于振捣器作用半径的1.5倍。⑸砼浇筑后1昼夜浇水养护,养护期不少于7d,砼强度未达到1.2MPa之前不得上人作业。6、模板工程⑴本工程模板采用钢木混合模板。模板支搭的标高、截面尺寸、平整度、垂直度应达到质量验收标准,以满足其钢度,稳定性要求。⑵模板支撑应牢固可靠,安装进程中须有防倾覆的临时固定措施。⑶本工程选用851脱模剂,每拆除一次模板经清理后涂刷脱模剂,再重新组装,以保证砼的外观质量。45
1、架子工程⑴本工程采用双排架子防护,外设立杆距墙2m,里皮距墙50cm,立杆间距1.5m,顺水间距1.2m,间距不大于1m。⑵架子底部夯实,垫木板,绑扫地杆。⑶为加强架子的稳定性,每七根立杆间设十字盖,斜杆与地面夹角60o。⑷为防止脚平架外倾,与结构采用钢性拉接,拉接点间距附和“垂四平六“的原则。⑸外防护架用闭目式安全网进行封闭,两平网塔接和网下口必须绑孔紧密。⑹结构架子高出作业层1m,每步架子满铺脚手板,要求严密牢固并严禁探头板。2、装饰工程装饰工程施工前,要组织质监部门、建设、设计、施工单位四方参加的主体结构工程核验收,对已完全体分部工程进行全面检查、发现问题及时处理,清除隐患,并做好装饰前材料、机具及技术准备工作。1、根据预算所需材料数量,提出材料进场日期,在不影响施工用料的原则下,尽量减少施工用地,按照供料计划分期分批组织材料进场。45
2、将墙面找方垂直线,清理基层,然后冲筋,按照图纸要求,分层找平垂直,阴阳角度方正,然后拉线作灰饼。底子灰应粘结牢固,并用刮杠刮平,木抹子抹平。3、罩面应均匀一致,并应在终凝前刮平压光,上三遍灰抹子。4、油漆、涂料施工:油漆工程施工时,施工环境应清洁干净,待抹灰、楼地面工程全部完工后方可施工,油漆涂刷前被涂物的表面必须干燥、清洁,刷漆时要多刷多理不流坠,达到薄厚均匀,色调一致,表面光亮。墙面涂料基层要求现整,对缝隙微小孔洞,要用腻子找平,并用砂纸磨平。为了使颜色一致,应使用同一配合比的涂料,使用时涂料搅匀,方可涂刷,接槎外留在阴阳角外必须保证涂层均匀一致表面不显刷纹。1、楼地面工程楼地面工程只作50厚豆石砼垫层。做垫层必须先冲筋后做垫层,其平整度要控制在4mm以内,加强养护4-5天后,才能进行上层施工。10、层面工程1、屋面保温层及找平层必须符合设计要求,防水采用防水卷材。2、做水泥砂浆找平层表面应平整压光,屋面与女儿墙交接处抹成R≥150mm圆角。45
3、本工程屋面材料防水,专业性强,为保证质量,我们请专业人员作防水层。4、原材料在使用前经化验合格后才能使用,不合格材料严禁使用。11、水、暖、电安装工程⑴管道安装应选用合格的产品,并按设计放线,坡度值及坡向应符合图纸和规范要求。⑵水、暖安装前做单项试压,完毕后做通、闭水后试验和打压试验,卫生间闭水试验不少于24小时。⑶电预埋管路宜沿最近线路敷设,应尽量减少弯曲,用线管的弯曲丝接套丝,折扁裂缝焊接,管口应套丝用堵头堵塞。油漆防腐等均符合图纸各施工规范及质量评定标准。⑷灯具、插座、开关等器具安装,其标高位置应符合设计要求,表面应平直洁净方正。⑸灯具、插座、开关等器具必须选用合格产品,不合格产品严禁使用。⑹做好各种绝缘接地电阻的测试和系统调整记录,检查配线的组序一定要符合设计要求。五、预防质量通病之措施本工程按优质工程进行管理与控制,其优质工程的目标体系与创优质工程的保证措施在本工程施工组织设计中做了详述。本措施不再述。45
创优质工程除对各分部、分项、工序工程施工中,精心操作,一丝不苟、高标准严要求作业外,关键是防止质量通病。为此,提出防止通病的作业措施如下:1、砖墙砌体组砌方法:⑴、组砌方法:一顺一丁组砌,由于这种方法有较多的丁砖,加强了在墙体厚度方向的连结,砌体的抗压强度要高一些。⑵、重视砖砌体水平灰缝的厚度不均与砂浆饱满度:①、水平灰缝不匀:规范规定砖砌体水平灰缝厚度与竖向灰缝宽度一般为10mm,但不应小于8mm,也不应小于12mm。砂浆的作用:一是铺平砖的砌筑表面,二是将块体砖粘接成一个整体。规范中之所以有厚度和宽度要求,是由于灰缝过薄,使砌体产生不均匀受力,影响砌体随载能力。如果灰缝过厚,由于砂浆抗压强度低于压的抗压可度。在荷载作用下,会增大砂浆的横向变形,降低砌体的强度。试验研究表明,当水平灰缝为12mm时,砖砌体的抗压强度极限,仅为10mm厚时的70-75%,所以要保证水平灰缝厚度在8-12mm之间。怎样确保水平灰缝的厚度呢?A、皮数杆上,一定将缝厚度标明、标准。B、砌砖时,一定要按皮数杆的分层挂线,将小线接紧,跟线铺灰,跟线砌筑。C、砌浆所用之中砂,一定要过筛,将大于5mm的砂子筛掉。45
D、要选砖,将过厚的砖剔掉。E、均匀铺灰,务使铺灰之厚度均匀一致。坚持“一块砖、一铲灰、一揉挤“的“三一“砌砖法“。②砂浆必须满铺,确保砂浆饱满度。规范规定:多孔砖砌体,水平灰缝的砂浆饱满度不得低于80%,这是因为,灰缝的饱满度,对砌体的强度影响很大。比如:根据试验研究,当水平灰缝满足80%以上,竖缝饱满度满足60%以上时,砌体强度较不饱满时,要提高2-3倍,怎样保证灰缝饱满度呢?A、支持使用所述的“三一“砌砖法,即“一块砖、一铲灰、一揉挤“。B、水平缝用铺浆法(铺浆长度≤50cm)砌筑,竖缝用挤浆法砌筑,竖缝还要畏助以加浆法,以使竖向饱满,绝不可用水冲灌浆法。C、砂浆使用时,如有淅水,须作二次拌合后再用。绝不可加水二次拌合。拌好的砂浆,须于3小时之内使用完毕。D、不可以干砖砌筑。淋砖时,一般以15%含水率为宜。(约砖块四周浸水15mm左右)。③注意砌砖时的拉结筋的留置方法:砖砌体的拉结筋留置方法,按设计要求招待。如设计没有具体规定时,按规范执行。规范规定“拉结筋的数量每12cm厚墙放1根Ф6钢筋,沿墙高每50cm45
留一组。埋入长度从墙的留槎处算起,每边均<100cm,末端应有弯钩”见图。规范还规定:“构造柱与墙连拉处,宜砌成马牙槎,并沿墙高每50cm设2Ф6拉结钢筋,每边伸入墙内>100cm。2、预防楼梯砼踏步掉角:楼梯踏步浇筑砼后,往往因达不到砼强度要求,就因施工需要提前使用,既便有了足够强度,使用不慎,都会掉楞掉角。而且有了掉角,修补十分困难,且不定期牢固。为此宜采用两种方式予以防治:⑴踏步楞角上,在浇筑砼时增设防护钢筋。⑵踏步拆模时,立即以砂袋将踏步覆盖。(水泥袋或用针织袋装砂)既有利于砼养护,又可保护踏步楞角。3、楼梯弊端的预防:防止踏步不等高:踏步不等高,既不美观,又影响使用。踏步不等高现象,一般发生在最上或最下一步踏步中。产生的原则,一是建筑标高与结构标高不吻合。二是将结构标高误为建筑标高。三是施工粗心,支模有误。为此,浇筑楼梯之间:⑴仔细核查楼梯结构图与建筑图中的标高是否吻合。经查核与细致计算无误后,再制作安装模板。⑵45
浇筑砼中,往往由于操作与模板细微变形,也会使踏步有稍话误差。这一个误差,要在水泥砂浆罩面时予以调整。为使罩面有标准。在罩面之前,根据平台标高在楼梯侧面墙上弹出一道踏步踏级的标准斜线。罩面抹灰时,便踏步的外阳角恰恰落在这一条斜线上。这样做,罩面完成后,踏步的级高级宽就一致了。⑶如果,施工出现踏步尺寸有较大误差,一定要先行剔凿,并用细石砼或高强度水泥砂浆调整生,再做罩面。4、堵好脚手眼:堵脚手眼做得好坏,直接影响装修质量。一是影响墙面抹灰之脱落、开裂也空鼓;二是洒水可沿已开裂的脚手眼进入室内。因此,堵脚手眼的工作万不可忽视、大意:⑴将脚手眼孔内的砂浆、灰尘凿掉,清除洁净,洒水湿透眼内孔壁。⑵将砖浸水湿透。脚手眼内外同时堵砌,绝不准用干砖堵塞。⑶用“一砖、一铲灰、一挤塞“三一砌砖法堵塞,绝不准用碎块碴堵塞。⑷砂浆必须饱满(最后的一块砖堵完后,用竹片或扁平钢筋将砂浆塞实,刮平,灰缝要均匀、实心实意,不准不刮浆干塞砖块)。5、散水砼变形缝的做法:45
砼散水的变形缝,常规做法是镶嵌木条,砼浇筑有足够强度后将此木条取出,再灌以沥青砂浆。其缺点是L散水板块相邻高差平整不易保证,木嵌条不可取净,取木条将板块楞角碰坏,不灌沥青砂浆而灌热沥青等。好的做法是:⑴、事先按变形的长短、高度(板块砼厚)的制作厚为20mm的沥青砂浆板条;⑵砼板块浇筑前,第一块板的断缝处支设模块,砼有足够强度(1.2Mpa)后,拆除侧模板,将预制沥青砂浆板条贴粘在砼板块侧缝表面,接着浇筑第二块板块砼。集资或跳浇散水板块。(靠墙身处不支模板,直接将沥青砂浆板条粘贴)。⑶当板块砼都有了足够强度后,再用加热后的铁铬子,将缝处沥青砂浆板条予以慰汤,使其缝隙深浅一致,交角平顺。6、卫生间地面漏水的预防:⑴现浇砼楼板:沿房间四周墙上翻150mm。⑵找平层:施工前,清理面层须洁净,并湿润砼楼板表面,之后刷一层TG胶素水泥浆。⑶找坡层用细石砼,并找出排队水坡度,坡向地漏,要平整光洁。上刷冷底油一道。⑷防水层:用一布四涂。但沿四周墙上150mm,遇向口时,伸向口外300mm。⑸粘结层:用1:20水泥砂浆厚≥20mm,沿墙四周上翻150mm并粉光。注意排水坡度与坡向或做C20细石砼。7、管道根部的渗漏预防:⑴45
、浇筑钢筋砼楼板,用时准确地将位置、尺寸预留楼板管道孔。或埋设预留套管。⑵、如为预留孔洞时,要预留万不可事后凿孔或扩孔。如为预留套管进,位置一定要准确。套管要焊上止水钢环。⑶、预留孔洞的模盒或套管一棕要与楼板的模板固定防止错位。浇筑砼时派专人看护,以利及时修正。⑷、地面的做法按设计要求进行或建议甲方按上述“地面漏水防预“中所提做法处理,但防水层必须沿套管或给排水管上翻150mm并与管子贴粘牢固。⑸、如为预留孔洞,等管道安装就位并校正固定后,对预留洞要用与楼板同标号的砂浆(或1:2-1:2.5的水泥砂浆等)填实、捣固,使其与砼结合密实,决不许以碎砖、碎石、杂物随意堵塞。⑹、做地面时,切切注意地面排水坡度与坡向。8、门窗固定用木砖的改进:木门传统的固定方法是:用钉子将木门框固定在预先埋设在砖内的木砖上。每边固定点不少于2处,间距≯1.2m。这种传统做法的弊端是:木砖容易松动,木砖漏留,木砖大小倒放等,致使门窗的安装质量受到影响。改进方法是以用C20砼制成120mm及240mm的预制块,内预埋木砖。⑴、木砖埋入预制块模具前,须以防腐处理。⑵、120预制块用于370墙及120墙中。240预制块用于240墙中。45
9、塑钢窗之固定:⑴、塑钢窗与墙体的固定用连接点的设置:距框角≯180mm;间距≯600mm。眼下存在的问题是:设置连接点不足,甚或漏设,这不仅影响门窗板动不稳,更有甚者会影响日后擦窗人的生命安全。为此,日后一定要按图示之要求设置固定杠用连接点。⑵、连接点的钉固方法:墙体砌筑时,将C20砼预制块,不论砖墙、砼墙、加气块墙、都用射钉将铁板连接条钉在墙上,更有将普通铁钉钉在墙上者,都是极不安全,极不妥的操作方法。⑶、固定门窗框用的连接铁板与钉接:①、连接铁板条:其规格为:(长×宽×厚)≥140mm×20mm×1.5mm射钉规格为:(直径×长)≥3.7mm×42mm或金属胀锚螺栓:(直径×长)≥8mm×65mm施工中,常常见到连接铁板条规格过小(厚不到1mm),甚至有的用0.5mm的镀锌铁皮剪成条状做连接铁板条用,用直径4mm的螺钉固定连接铁板条,都不是妥的,或直接用铁钉钉更为不妥。②、连接铁板条与塑钢之连接,用塑钢抽芯铆钉,其直径≥5mm,不用5mm螺钉或4mm的自攻螺丝。45
⑷、预防塑钢与铁制连接铁板条之间的电偶腐蚀L:为了防止塑钢和连接铁板条之间的电偶腐蚀,采取下列措施:①、采用镀锌钢板制作连接铁板条。②、或将连接用铁板条与塑钢之间用塑料膜隔开。③、或用密封漆将塑钢与铁板条之间,窗框与墙之间予以封闭以免雨水浸入。10、给水管道施工给水管道安装施工比较简单。便是它是承压管,将受较高水压力,如粗心施工,也会带来管道渗漏,为此:⑴、管子接口:①、丝口连接:加工丝扣时要做到:丝扣光滑、端正、不抖丝、不乱扣、有椎度。这五点都要达到。有一点不符合要求,剔出重新加工或切去此端重做。②、焊接接口:设计要要求坡口焊时,坡口加工的形式须符合设计要求。不需坡口焊时,在焊前用砂布将管口打磨干净,两管对口间要均匀,不可一侧大,一侧小。焊接时,焊缝高度要符合规范要求。⑵、安装①、安装前弄清图纸,查清管子位置,走向、标高。并做现场查验当实际尺寸与图纸不符合时,提出修正,以免与土建产生矛盾。45
②、安装时,管子必须找正后再拧紧,不得倒拧,以免损坏丝扣。⑶、下料:管道不料时,尺寸一定要准确,给水管误差≤5mm。为确保下料时尺寸准确,对实际安装位置与尺寸进行实测实量,不要按图纸尺寸下料。同时,必须逐根管道都要实测实量。⑷、水压试验:①、把好水压试验关,是控制管道安装质量的关键。②、压力表必须精确,使用前要进行校验。③、试验时,第一要查看压力表的压力降,第二要逐房间察看管道的渗漏情况。④、渗水的接头、管子必须返工。大面积漏水的管段必须换掉或修理,并至不再出现“跑、冒、漏、渗“为止。11、注意配电箱的产品质量验收:市场采购的配电箱,不少是不符合国家标准的新产品。除新产品的外观质量外,突出的质量缺点是:⑴、不设零线;⑵、没有设置零线与保护接地汇流排。这种缺陷的存在,在接线时,往往将箱上的所有插座的零线串接,保护接地串接。这样,当前面的插座坏了,接在后面的几个插座就会发生零线断线或地线断线,造成搞插座没有电,或在发生漏电事故时,漏电开关不动作,严重者造成人员伤亡。45
为此,在采购配电箱时和安装配电箱之前,对其质量进行检查。查看是否分别设置了零线和保护地线汇流排。不合格者,不得使用。12、插座接线:⑴、单相二线插座:原则是“开关永远控制相线“。⑵、单相三线插座:面对插座的右孔接相线,左孔接零线。13、电器的接地电器安装中,首先考虑的就是用电安全。低压系统地接地保护最优形式就是“三相五线制供电形式“,它非常适用于分散的民用建筑,也适用于施工现场的临时供电。从电源时入配电箱之后,从接地板的引上线和电源中性点的焦点处,向室内分出保护线PE和进入电路的零线N,在建筑物地也不得混淆,困为,一旦线进入电路,就有电源通过,混淆后,就会引起漏保护器跳闸,影响正常使用。所以在用户配电线路中,插座中的线和线应该统一有颜色的区别。六、工程进度计划工期控制:要工程计划自2004年8月15日开工,2005年7月10日竣工,总工期330天。为保证工期目标的实现,将施工过程划分为五个阶段。1、基础施工阶段:45
自2004年8月15日至9月30日为基础工程施工阶段,本阶段需要完成定位放线、挖工、砂砾垫层、条形基础砼、毛石基础、地圈梁等项目。同时,安排人员按图纸设计要求预制门、窗梁主体结构钢筋制作,模板配制,主体施工做好准备工作。2、主体施工阶段:自2004年10月1日至2004年12月30日是主体施工阶段,本阶段要完成墙体砌筑,预制过梁安装,现浇钢筋砼,梁、板的支模、砼等项目。主体施工阶段组织流水施工,每层主体施工15天。施工期间,水、暖、电施工人员密切配合,作好预留、预埋工作,避免事后在墙体上打洞。3、装修施工阶段:自2005年3月1日至2005年6月20日为装修工程施工阶段。4、安装工程施工阶段:自基础工程至装修工程,安装工程施工贯穿始终,从时间上虽然与土建同步进行,但本工程设计有给排水、采暖、一般电照处还有电话、有线电视,所以说,是一个水暖、电等较齐全的工程。为此,在劳动力安排上专门有水暖工、电工施工班组与土建施工密切配合,相对独立地完成水暖、电安装工程施工任务。5、工程收尾交工阶段:45
本阶段主要做好成品保护及清理等工作。七、施工平面布置(见附图)施工平面布置原则是:1、尽最大可能少占施工用地,对划定的施工用地,作合理安排;2、塔吊固定后,主要材料及搅拌机械的布置,以其服务业范围为准,紧凑布置。3、根据工程进度,动态管理施工总平面,该高速时及时调整;4、交通道路、供水、供电、消防一次到位进行布置,确保道路通畅,供水供电空耗小,供应充足,并确保工地消防安全。5、建立文明施工现场:材料、配件、工棚、厕所、大宗材料按施工平面图严格要求就位管理,周转材料堆放有序。八、施工组织措施本工程采取项目管理法,按目标进行管理与控制,以目标计划来指导管理与控制行动,变以往以行动来实现目标的被动管理方式为以目标指导行动的主动的主动管理方式。将主动管理与被动管理相结合、前馈控制与反馈控制相结合,事先控制与事中、事后控制相结合。㈠、确保工程进度、实现合同工期的措施:1、工期目标:(平面流水、主体交叉施工)45
控制工期目标330天;其中:±0.00以下工期目标45天;主体结构工期目标:90天;内、外装饰工期目标:80天;水暖电安装工期目标:90天;收尾工期目标:10天。2、确保工期目标的措施:⑴、组建职能完善、人员配套、分工明确的施工项目管理组:项目经理:统筹工期目标,制定工期目标施工措施,决策生产要素供应与优化配置,检查平衡工期目标的实施;技术负责人:制定工期目标计划实施的技术措施,监督按工艺程序施工,解决施工技术措施实施中工期目标计划之失衡;解决施工技术措施实施中工期目标计划之实施,协调工种之穿插,布置与平衡生产要素,做好施工计划之安排与统计;料具供应员:组织材料、构配件、机具之供应,根据生产进度编制料具供应计划;财务管理员:根据工期安排与施工进度计划落实资金之供应,提出月奖金之收支计划,按期收取工程进度款;⑵、按分部分项工程进度制定施工技术措施,制定合理施工流水程序,严格要求操作程序与操作要点之管理,保证工期目标计划之顺利实施;45
⑶、以日调度日平衡为手段,项目经理及有关人员跟踪检查工期目标计划之实施,对工期目标计划做动态管理与监控;⑷、采取激励措施,对工期、工程质量、安全生产、文明施工的管理者与操作者有上好成绩者予以奖励。㈡、确保工程质量,实现人同质量目标措施:1、质量目标:工程质量总目标:合格,按合格目标进行控制与管理。其中:基础分部工程质量目标:合格;主体工程质量目标:合格;装饰工程质量目标:合格;屋面工程质量目标:合格;门窗工程质量目标:合格;地面楼地面工程质量目标:合格;给排水及供暖工程质量目标:合格;电气、照明工程质量目标:合格;2、确保工程质量目标计划实现的措施:⑴、项目经理部职能组织人员分工明确、职责分明项目经理:施工项目的本权负责人,是质量第一负责人。主管质量之制定,监控质量目标计划之实施评价与激励;45
技术负责人:主持质量目标实施的技术措施之制定,确保质量目标与技术措施对有关工长、作业班长之技术交底、监督技术措施之执行、作好跟踪检查与操作生产调查、建议项目经理与总工长调整作业布置与调换不良作业人员;总工长:监督施工技术措施之履行、调整不良作业人员之岗位、作好材料构配件事先检查、监控配合比的严格执行;有关工长:跟踪检查操作要点之执行、纠正不良作业事件。作好自检、与检、交接质量检查。作好工序、分项工程、分部工程质量进行检查、验收。建议对不良作业人员进行岗位调整;有关班组长与班组质量检查员:对本班人员进行班前操作交底,进行班后作业自检与奖评,监督本班组人员严格操作要点进行作业,参与互检与交接检查,调换不良作业人员岗位;⑵、针对本工程特点与本公司的质量通病,由技术负责人设置质量控制点,并制定操作要点与防治措施,实行重点监控;⑶、工程质量是企业生命,工程质量人人有责,工层层确保工程质量的技术交流;⑷、对工程质量施行“开路“、“一票否决“、“挂牌作业“。工程质量与进度发生矛盾,以质量为主;工程质量与人员安排发生矛盾,以质量为主调换人员;工程质量与材料发生矛盾,以质量为主调换材料;工程质量与机具发生矛盾,以质量为主调换机具;工程质量与工资挂钩,施行优质优奖;⑸、作好材料、构配件的事先检验与控制,把好三关:把好材料、构配件进场验收关:不合格者不准进场;把好材料复试关:对主材料(钢材、水泥、骨料、砖、装饰材料)作好复验,不合格材料不准使用;45
把好材料使用关:正确执行配合比,做好材料计量、正确按规格、品种、数量、强度使用材料,劣材不充好材用,好材不做劣材用,物尽其用;⑹、作好反馈工作:事先了解可能出现质量的部位与质量事件以及可能出现质量风险,并制定防范措施,予以事先控制;⑺、完善项目经理部的质量保证体系与质量管理的法规体系。㈢、确保安全目标实现,保证安全施工的措施:1、安全目标计划:本项目施工全过程中⑴、消灭重伤事故⑵、消灭伤亡事故⑶、消灭多人事故⑷、轻伤事故率:2‰2、确保安全生产的措施⑴、项目经理部有关要员与职能机构,对确保安全生产分工明确,职责分明;项目经理:是企业法人代表在本项目施工管理听全权委托代理人,是安全生产的第一负责人,主持安全措施之制定,组织安全教育与培训,组织安全设施之搭设,组织现场安全宣传与监控,组织项目安全交底,审核五种人员安全作业资格(电气、起重、焊接、机动驾驶、商空作业),组织劳动保护用品之购置与保证,监督安全措施之实施。45
技术负责人:负安全生产的技术责任,制定安全措施,主持安全教育的培训,监督安全措施之实施,对有关工长、专业工种、班组长作好安全交底,建议调换不重视安全生产的管理人员与作业人员。总工长:对有关工长、班组长作安全交底,监督安全措施之实施,调换不重视安全作业人员,监督设施搭设,组织施工平面之布置,监督违章作业,组织与监督有关工长与班组长安全程序施工。有关工长:对本工种作业班组及人员作安全作业交底,监督本工种有关作业规程施工操作,调换不重视安全的作业人员并作专项安全检查交底与检查。专职安全检查员:监督有关工种按作业规程作业,跟踪检查安全作业与安全设施之搭设防,建议调换违章工作人员,时时事事宣传安全作业的重要性,检查劳动保护用品之发放与使用。班组长与班组安全检查员:作好班前安全作业交底班后安全作业奖评,随时检查本班组作业人员按安全检查规定作业,建议奖励安全生产有功人员,随时纠正违章作业,调换不重视安全生产作业人员之岗位。⑵、按工种特点制定工种安全作业交底与作业规程,并进行两级安全交底(技术人对总工长、工长交底;总工长、工长对班组长及作业人员交底)。45
⑶、编制现场安全措施,并贯彻在施工全过程。⑷、作好安全教育及现场安全宣传。安全教育分为新工人入场教育(项目经理及技术负责人负责)分部分项工程开工前教育(总工长、有关工长负责)工序施工的班前教育与班后奖评(有关工长、班组长负责)。现场安全宣传内容为安全标志、现场安全规则、“三宝”、“四口”利用,标志等,安全检查员负责监督实施。⑸、每个月,项目经理组织一次现场安全大检查。由有关工长、总工长、专职安全员参加,随检查随整改随奖评。⑹、五大专业工种持证上岗⑺、本工程开工前,对施工机械、施工用电等重点编制安全技术措施。㈣、现场文明施工措施:1、现场文明施工指标:⑴、按施工平面图布置材料、机械、电路及管路铺设、临时设修建、道路修建、防火消防设施安设、交通要道防护;⑵、工完场清、随时清、时时清、班后清、使现场整洁有序。食堂、宿舍清洁卫生;⑶、现场文明标志,安全标志,施工责任标志等设齐全完整。2、确保现场文明责任制:⑴、明确现场文明施工责任制;45
项目经理:负布置;有关工长:负清场责任、督促、奖评责任;有关班组长:负责场清、时时清、班后清责任;总工长:负机械按平面图就位责任、监督施工平面图严格执行责任。⑵合理利用现场,科学布置施工总平面图,务使平面图规划合理,物资设备有序。⑶、与每个月安全检查之同时,项目经理组织有关人员对文明施工进行检查,随检查、随纠偏、随整改、随奖评。㈤、综合考评按区建议厅96年4月22日颁发的“工程现场综合考评办法”,每月末对本工地现场进行一次综合考评检查,并认真打分,由项目经理组织公司派人参加。九、工程质量控制标准㈠、质量标准1、分项工程(1)、合格:①、保证项目,必须符合相应评定标准的规定②、检验批项目,抽查点应符合相应质量评定标准的合格规定;③45
、实测项目,抽查点数中,建筑工程有80%以上,建安工程有80%以上的实测值应基本在到相应质量检验评定标准的规定。(2)、注意:当分项工程质量不符合相应质量检验评定标准合格的规定时,必须及时处理,并以按以下规定确定其质量等级。①、返工重作的,可重新评定质量等级;②、经加固补强或经法定检测单位鉴定能够达到设计要求时,其质量仅能评为合格;③、经法定检测单位鉴定达不到原设计要求,但经设计单位签认,可满足结构安全和使用功能要求,可不加固补强的,或经加固有补强改变外形尺寸或造成永久性缺陷的,其质量可定为合格。2、分部工程⑴、合格:所含分项工程的质量全部合格;3、单位工程:⑴、合格:①所含分部工程的质量全部合格;②质量保证资料应符合本标准的规定;③观感质量评定得分率达到90%以上。②质量保证资料应符合本标准的规定;③观感质量评定得分率达到90%及其以上。㈡、工程分解体系:(见附图)㈢、目标体系:1、目标保证体系:45
工序作业质量目标(保证)保证分项目标(保证)分部质量目标(保证)单位工程质量目标。2、目标体系:由工序作业质量目标完成,首先制定工序作业质量目标,其次制定分项质量目标,再其次制定分部工程质量目标,最后制定单位工程质量目标,这样就形成了一个单位工程的完整的目标体系。本住宅楼,其目标体系制定如下:⑴、这一单位工程,由下列分部工程组成:地基与基础工程、主体结构工程、装饰工程、层面工程、上下水与采暖、电气六个分部工程。⑵、地基与基础分部工程由下列分项组成:挖坑、砂砾垫层、C10砼垫层、条形基础、毛石基础、C30钢筋砼地梁、防潮层、回填土七道分项工程组成。⑶、主体结构分部工程,由下列分项组成:砌体、梁、板、C20构造柱,C20圈梁等分项工程。⑷、装饰分部工程由下列分项组成:一般室内抹灰、外墙抹灰墙面、刷涂料、楼地面、门窗五道分项工程。⑹、屋面分部工程由下列分项组成:屋面找水平、保温层、卷材防水层、瓦屋面四道分项工程组成。⑺、上下水与采暖分部工程由下列分项组成:上水管道安装`上水管道附件与卫生器具安装、采暖管道安装、采暖器附件安装四个分项工程。45
⑻电气分部工程由下列分项组成:配管及管内穿线、护套配线、电气照明灯具及配电箱安装、接地装置四道分项工程。3、质量目标制定:⑴、首先确定单位工程的质量目标;工程质量目标,就是单位工程的质量评定等级,这个目标,在工程承包合同中已做了明确界定(是合格);其次,规划六个分部工程的质量目标;要明确哪几个分部工程质量必须达到合格标准,才能确保单位工程达到合格。⑵、质量目标制定依据:①、两个承包合同:工程承包合同中规定的本单位工程的目标;项目经理经营承包合同中明确的质量责任目标;②、有关法规、标准、定额;③、有关图纸、招标文件、施工组织设计、资料;④、生产要素的实际状况与动态;⑤、设计要求与有关说明。⑶、以地其基础分部工程为例,其质量目标如下:①、基础分部工程的分项工程质量目标如下图:②、其他分部工程的分项工程的质量目标,中标后由项目经理部制定。㈣、目标控制与管理:45
1、目标控制:项目中在实现所定目标过程中,按预定目标计划实施(也就是将所定目标做为管理活动的中心),在实施管理的过程中,由于各因素会对之产生干扰,项目经理部就要通过检查,获取目标实施中信息,将之与原目标计划进行比较,发现偏差,采取相应措施纠正偏差,确保目标计划的正常实施,最终获得预定目标计划之实施。这是一种将经济活动和管理活动的任务,转换为具体目标加以实施和控制的主动管理法,它的精华就是以目标来指导行动。2、实行目标管理或控制,要有两个条件其一:有一个明确的目标计划体系,如上所述,首先,将施工项目进行分解,形成一个工程分解体系,其次根据工程项目的分解体系,从单位到有关工序制定目标计划,使这形成一个目标计划体系。这样就便于实行目标控制与管理了。其二:有一个合格的控制与管理体系。我们的控制与管理主体就是项目经理与其相应在的有关作业层(工程队),直到作业班组,这就形成了一个控制与管理的工作体系。⑴、工程施工体系(生产体系):⑵、质量控制与管理体系(组织体系):⑶、质量控制与管理法规体系:3、施工阶段质量控制的全过程:4、施工阶段质量控制原则:⑴、以预防为主,重点做好事前控制,防患于未然,将质量问题消除在萌芽状态;⑵、坚持质量标准,严格检查,热情帮助;45
⑶、结合工程特点,结合实际确定控制范围深度与采取的控制方法;⑷、尊重事实,尊重科学,以理服人处理质量问题。5、施工阶段质量控制依据:⑴、有关原材料技术标准;⑵、有关构配件取样试验标准;⑶、有关技术鉴定书;⑷、有关操作规程;⑸、有关规范及验收标准。㈤、施工阶段工程质量管理与控制方法:1、有关技术文件的编制与审核:这是对施工阶段工程质量进行全面管理与控制的重要手段。⑴、审核进入施工现场各分包单位的技术资质证明;⑵、编写开工报告并审核上报;⑶、编写施工方案或施工组织设计,对确保工程质量有可靠技术措施,审核后上报;⑷、编写分部分项工程及重点部位的技术与安全操作要点,并做了全面交底;⑸、原材料、构配件取样送验,并审查试验报告;⑹、进行图纸会审送签署会审记录;⑺45
、对生产五要素(材料、机械、人员、资金、施工方法与环境)进行事先审查。2、质量监督与检查:⑴、检查内容:①、开工之前检查:目标是检查是否具备开工条件,开工后能否保证工程质量,能否确保工程连续正常施工。②、工序作业检查:检查是否按规范、规程与施工方案,交底文件进行作业;③、工序交接检查:在自检、交接检、专职检的基础上,对主要工序和对工程质量有重大影响的工序,由有关工长、专职检查员、甲方代表、监理工程师做工序交接验收检查;④、隐蔽工程检查:凡属隐蔽工程,必须由专职检查员,甲方代表或监理工程师会同一起隐蔽检查验收,并经监理工程师或甲方代表签证后,方能掩盖;⑤、停工后再复工前的检查:需经监理工程师或甲方代表检查认可后,方能下复工令复工;⑥、分项、分部工程,均应经监理工程师或甲方代表检查认可后,方能下复工令复工;⑦、随班跟踪检查:对主要工序容易产生质量事故或通病的工序,专职检查员及有关工长,随班跟踪检查。⑵、检查方法:①、目测法:看、摸、敲、照看:根据质量标准,进行外观目测;45
摸:手感检查;敲:以工具敲击,进行音感检查;照:对暗阴部位以镜子反光检查;②、实测法:吊、量、套、靠吊:以托线板、线锤检查垂直度;量:以测量工具、计量仪表对断在尺寸、轴线、标高、湿度、湿度检查;套:以方尺套方,辅以塞尺检查;靠:以直尺辅以塞尺进行检查;③、试验检查:必须通过试验,才能对质量进行判断,此时使用此方法。3、工序的质量控制:工程项目的施工过程:由一系列相互关联,相互制约的工序所构成。工序的质量是工程项目整体质量的基础。为把工程项目的产品质量管理好,以预防为主,首先就是将工序质量管理好。工序质量包括两个内容:其一是工序活动条件的质量(即每道工序之投入的五要素:人、材、机、资金、技术)要符合要求;其二是工序活动效果的质量(即每道工序施工完成的工程产品要达到有关质量标准)要符合标准要求。⑴、工序质量控制的内容:①、确定工序质量控制流程:45
每道工序完成后(工序产品)→施工自检、互检→会同工长检查验收→通知监理工程师或甲方代表进行工序检查,并办理工序质量验收签证→下道工序施工。②、如上所述,工序活动条件,是指影响工程质量的诸要素(五要素)。找出影响工程质量的重要因素,并加以控制,才可达到工序质量控制之目的。③、及时检查工序质量,并进行分析判断。④、设置工序质量控制点:质量控制点是指:为了保证工序质量而需要控制的重点或部位,或者是薄弱环节,对设之质量控制点可以首先析其可能赞成质量隐患的原因,再针对隐患原因,制定出对策予以预先控制。⑵、工序质量控制点的设置:设置工序质量控制点,并对之进行控制,是对工序质量进行预检的有效措施,要根据工程特点、重要性、复杂程度、准确性、质量标准与要求,全面合理的选定质量控制点,它可能是结构复杂的某一工程项目,也可能是技术要求高,施工难度最大的某一结构构件,也可能是某一分部工程,也可能是影响工序质量的某一个环节。技术操作、材料、机械、施工顺序、技术参数、自然条件、工程环节都可以作为质量控制点来设置,主要视其对质量性之影响的大小及危害程度而定。举例如下:45
⑴、人的行为:避免人的行为失误赞成质量事故。对高空、高温、水下、危险作业,易燃易爆作业,吊装作业,动作复杂而快速运转的机械作业,精密度及技术要求高的作业,都应从人的生理缺陷、心理活动、技术能力、思维方法、思想素质等方面进行考核,反复交底,以免由于行为的错误,导致违章作业,产生质量事故;⑵、物的状态:有的工序质量控制中,以物的状态为控制重点如施工精密与施工机具有关;如计量不准与计量仪表或计量设备有关,又如主体义叉或多工种密集作业与作业有关等。⑶、材料质量与性能:材料性能与质量直接影响到工程质量。⑷、施工顺序:有的工序作业,必须严格控制相互之间的操作施工顺序,如有违背,将出现对质量不利影响。⑸、技术间歇:有的工序作业,工序之间的技术间歇,其时间性很强,如不严格控制,就会影响工程质量。如砖墙砌筑完成后,一定要有-10D的技术间歇,以便让墙体充分沉陷、稳定、干燥,然后才能抹灰,如违反,立即抹灰,会形成灰面脱落、空鼓。⑹、技术参数:有些技术对数与质量有密切关系,必须严格控制。如:砼配合比,外加剂掺量,夯实土的最佳含水量等。45
⑺、常见之质量通病:如“渗、漏、泛、堵、壳、裂、砂、锈“等通病的部位,要事先研究消除对策,采取预防措施。⑻、新工艺、新材料、新技术之应用:都必须事先鉴定试验,或虽有鉴定与试验,但本施工单位首次采用,缺乏经验,也应设为质量控制点,严加控制。⑼、质量不够,不合格率较高的产品:这些产品,根据数据统计,表明质量波动较大,不稳定,不合格率较高,应设为质量控制台点,予以控制。㈥、施工阶段质量影响因素(五要素)的控制:(本节只涉及人、材、机、方法、环境五要素,它属于事前控制控制之范畴)1、人的控制:指直接参与工程实践的组织者、指挥者、操作者。对人进行控制之目的,是避免人的失误,并调动其积极性。其要点如下:⑴、人的技术水平:人的技术水平高低,直接影响到工程质量之水平,为此,对技术复杂,难道大,精密要求高的工序操作,要由技术熟练、经验丰富的人来完成。必要时,对其技术水平予以考核。⑵、人的生理缺陷:根据工程特点和作业环境,对人的生理缺陷严加控制。如反应迟钝,应变能力差的人,不能操作快速运行,动作复杂的机械设备等。45
⑶、人的心理行为:人的心理行为受社会、经济、环境、人际关系之影响,并要接受组织与管理的约束。因为,其劳动态度、注意力、情绪、责任心有不同地点、不同时间有不同变化,为保证质量万无一失,在关键工序和操作上,要控制思想活动,稳定其情绪。⑷、对材料的质量控制:材料质量工程质量的基础,材料质量不符合要求,不可能干出符合质量标准的工程。所以,对材料质量进行控制,是提高工程质量的重要保证,材料控制要点如下:①、订货:对主要装饰材料及配件,订货前,需查清生产厂家情况,看样,向甲方提供样品,同意后,才可正式订货。②、主要设备:订货前,和甲方和监理工程师提出申请,核实是否符合要求;③、主要材料进场时,须具备出厂合格证或化验单,或乙方复检单。所有材料必须具备检验单并经监理工程师验证后方可正式使用;④、所有构配件,皆必须具备厂家批号及出厂合格证;⑤、凡标志不清或有质量怀疑的材料,一定进行复试;⑥、现场配制的材料,先提出试配要求,一定进行复试;⑦45
、对材料性能、质量标准、适用范围、对施工要求等必须充分了解,慎重选用。如红色大理石或带色纹(红、暗红、金黄色纹)的大理石,因其易风人剥落,不宜用于外装饰。早强三乙醇不能用作抗冻剂等。3、施工机械的控制:施工机械对项目的施工进度及质量有着直接影响,从保证施工质量出发,必须从其选型、主要参数、使用操作三方面进行控制;⑴、机械的选型:选择之原则是:因地制宜,因工程制宜,技术上先进,经济上合理,生产上适用,性能上可靠,使用上安全,操作上方便,维修便利。⑵、主要参数:其性能参数,要能满足施工要求,保证质量要求。如选用超重机械时,必须使其参数能满足超重、超重高度、超重半径的要求。⑶、使用与操作:合理使用,正确操作,是保证施工质量的主要环节。如超重机械要确保四限位装置齐全(行程、高度、高幅、超荷)。4、施工方案正确与否,直接影响到项目的进度、质量、成本控制施工方案考虑不妥,会拖延工期、影响质量、增加成本。为此,选定施工方案时,必须结合工程实际,从技术、组织、管理、经济等方面进行全面分析,综合考虑。45
5、环境因素控制:项目施工的环境因素有:技术环境(地质、水文、气象等),管理环境(质量保证体系、质量制度等),劳动环境(劳动组合、劳动工具、工作面等)。环境因素对质量之影响具有复杂而多变之特点,因之,对主要采取有效措施加以控制,对环境之控制,又与方案及技术措施有关。㈦、施工阶段的工程预检:预检是指,工程未施工前所进行的预先检查。审保证质量,防患于未然的有力措施。⑴、建筑物位置、座标、标高:预检座标标准桩、水平桩。⑵、基础工程:预检轴线、标高、预留孔及洞、预埋件位置与数量;⑶、砌体工程:预检墙身轴线、楼层标高、砂浆配合比划预留孔洞位置及尺寸;⑷、钢筋砼工程:预检模板尺寸、轴线、标高、支撑、预埋件、预留孔等;钢筋型号、规格、数量、锚固长度、焊接、绑扎、保护层等;砼配合比、计量手段、外加剂、养护条件等;⑸、主要管线工程:预检标高、位置、坡度、管线等;⑹、构配件工程:预检安装位置、型号、标高、支承长度等;45
⑺、电气工程:预检变电配位置、高低压进出口方向、电缆沟位置、标高、送电方向。㈧、成品保护:对完成品,进行妥善保护,确保质量、顺利竣工。㈡质量与安全组织保证体系㈢质量与安全法规体系㈣工程质量控制体系㈤进度控制系统45'